Hue-assisted automatic registration of color point clouds

  • Men, Hao;Pochiraju, Kishore
    • Journal of Computational Design and Engineering
    • /
    • v.1 no.4
    • /
    • pp.223-232
    • /
    • 2014
  • This paper describes a variant of the extended Gaussian image based registration algorithm for point clouds with surface color information. The method correlates the distributions of surface normals for rotational alignment and grid occupancy for translational alignment with hue filters applied during the construction of surface normal histograms and occupancy grids. In this method, the size of the point cloud is reduced with a hue-based down sampling that is independent of the point sample density or local geometry. Experimental results show that use of the hue filters increases the registration speed and improves the registration accuracy. Coarse rigid transformations determined in this step enable fine alignment with dense, unfiltered point clouds or using Iterative Common Point (ICP) alignment techniques.

Point Cloud Slicing Based on 2D Delaunay Triangulation (2D Delaunay Triangulation을 이용한 점군 절단)

  • Park, Hyeong-Tae;Chang, Min-Ho;Park, Sang-Chul
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.5
    • /
    • pp.127-134
    • /
    • 2007
  • Presented in the paper is an algorithm to generate a section curve by slicing a point cloud including tens of thousands of points. Although, there have been previous research results on the slicing problem, they are quite sensitive on the density variations of the point cloud, as well as on the local noise in the point cloud. To relive the difficulties, three technological requirements are identified; 1) dominant point sampling, 2) avoiding local vibration, and 3) robustness on the density changes. To satisfy these requirements, we propose a new slicing algorithm which is based on a node-sphere diagram. The algorithm has been implemented and tested with various examples.

Effect of Relative Humidity on the Breakthrough of Charcoal Tubes during Mixed Organic Vapor Sampling (혼합 유기용제 포집시 습도가 활성탄관의 파과에 미치는 영향)

  • Yang, Hyeok Syng;Kim, Hyunwook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.6 no.1
    • /
    • pp.125-137
    • /
    • 1996
  • This study was designed to investigate effects of relative humidity on the breakthrough of charcoal tubes at a fixed vapor concentration and sampling time during mixed organic vapor sampling. A vapor generator was used to generate three different concentrations of mixed organic vapor and a stainless steel chamber was fabricated and utilized to maintain three different percentages of relative humidity while maintaining a constant temperature. The results were as follows; 1. At high relative humidity, breakthrough of mixed organic vapor occurred quickly at low vapor concentration than at high vapor concentration because of the reduced adsorption volume of charcoal tube due to humidity. 2. Breakthrough by competitive adsorption of vapors onto charcoal tube was observed at first from n-hexane having the lowest boiling point and highest vapor pressure among the three organic vapors investigated, followed by TCE. No breakthrough was observed from toluene under all experimental conditions. 3. For n-hexane, breakthrough was observed after 2 hours of sampling and breakthrough rates were increased as relative humidity increased. For TCE, breakthrough was found after 3 hours of sampling and breakthrough rates by sampling time were increased as vapor concentration increased. 4. The adsorbed amount of mixed organic vapor at breakthrough was shown to have statistically significant correlations with sampling time, relative humidity, and vapor concentration in descending order of correlation. Relative humidity and sampling time for n-hexane and sampling time and concentration for TCE were both statistically significantly correlated. 5. Relative humidity was found to affect the amount of breakthrough of mixed organic vapor and n-hexane. Among three percentages of relative humidity investigated, the amount of breakthrough at 85 % relative humidity was significantly larger than those of at lower percentages of relative humidity. No statistically significant difference was found between 25 % and 55 % relative humidity. 6. The results of multiple regression analysis between breakthrough and relative humidity, vapor concentrations showed that the coefficient of determination of mixed organic vapor was 0.263 and those of n-hexane and TCE were 0.275 and 0.189, respectively. 7. Flow rates of sampling pumps used were found to be affected by relative humidity present. At 25 %, 55 %, and 85 % relative humidity, the relative errors of sampling pump were 1.4 %, 13.4 %, and 18.6 %, respectively. In conclusion, the results of this study showed that high relative humidity could reduce the adsorption volume of charcoal tubes and subsequently increase breakthrough rates. Therefore, to prevent breakthrough when sampling mixed organic vapors, it is suggested that either sampling volume be reduced on the flow rate be lowered so as to minimize breakthrough of the most volatile organic vapor in the mixture. In addition, since the flow rates of a sampling pump can be adversely affected by high relative humidity, it is recommended to use a constant flow mode pump when sampling in the highly humid environment.

  • PDF

High precision Gating Algorithm for Predictive Current Control of Phase Controlled Rectifier (위상제어 정류기의 예측전류제어를 위한 새로운 고정밀 게이팅 알고리즘)

  • 정세종;송승호
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.3
    • /
    • pp.206-211
    • /
    • 2004
  • In phase controlled rectifier, it's been known that a fast response is achieved by predictive current control without any overshoot. The frequent sampling period is essential to improve the firing accuracy in conventional predict current control. However, improving the firing accuracy if difficult to reduce the period of sampling efficiently because current sampling and predictive current control is carried out in every period and the ON-OFF current control is performed by comparing two different one. To improve the firing accuracy at the predictive current control, the calculated firing angle is loaded into the high-accuracy hardware timer. So the calculation of exact crossing point between the predictive and actual current is the most important. In this paper, the flow chart for proposed firing angle calculation algorithm is obtained for the fastest current control performance in transient state. The performance of proposed algorithm is verified through simulations and experiments.

Generalized Ratio-Cum-Product Type Estimator of Finite Population Mean in Double Sampling for Stratification

  • Tailor, Rajesh;Lone, Hilal A.;Pandey, Rajiv
    • Communications for Statistical Applications and Methods
    • /
    • v.22 no.3
    • /
    • pp.255-264
    • /
    • 2015
  • This paper addressed the problem of estimation of finite population mean in double sampling for stratification. This paper proposed a generalized ratio-cum-product type estimator of population mean. The bias and mean square error of the proposed estimator has been obtained upto the first degree of approximation. A particular member of the proposed generalized estimator was identified and studied from a comparison point of view. It is observed that the identified particular estimator is more efficient than usual unbiased estimator and Ige and Tripathi (1987) estimators. An empirical study was conducted in support of the theoretical findings.

Stability Margin of Finite Wordlength(FWL) Effects in Digital Implementation of Controllers (디지털 제어기 구현시 FWL 영향에 대한 안정도 여유)

  • Kim, Jin-Ho;Choi, Sun-Wook;Kim, Young-Chol
    • Proceedings of the KIEE Conference
    • /
    • 1999.11c
    • /
    • pp.533-536
    • /
    • 1999
  • We consider digital implementation problems of continuous-time controllers. In general, digital controllers use fixed point representation of number and of finite word length(FWL). Under these conditions, this paper investigates the closed-loop stability caused by three design constraints; (i) finite precision representation of the controller parameters, (ii) realization forms such as direct form, cascade form, and parallel form, and (iii) sampling time. We calculate the coefficient stability margins of both predesigned controllers and controller to be implemented. This method can be applied to determine the word length, realization structure, and sampling time so that remains the stability.

  • PDF

지하수 함양량 추정시 공간상에서의 자료 sampling 방법에 따른 Minimum Entropy Deconvolution의 적용성에 관한 검토

  • Kim Tae-Hui;Kim Yong-Je;Lee Gang-Geun
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2005.04a
    • /
    • pp.139-142
    • /
    • 2005
  • Kim and Lee(2005) suggested Minimum Entropy Deconvolution(MED) to estimate the temporal sequence of the relative recharge. However this study by Kim and Lee(2005) was just related to the verification of the conceptual approach with MED. In this study, we try to characterize the applicability of MED in the case of spatially heterogeneous recharge (distance from recharge area). Simulated results were recorded with some specific sampling points. Estimated results from this study show higher than 0.8 in cross-correlation with the original recharge sequence.

  • PDF

An Improved Group Sampling Plan Based on Time-Truncated Life Tests

  • Aslam, Muhammad;Pervaiz, Muhammad Khalid;Jun, Chi-Hyuck
    • Communications for Statistical Applications and Methods
    • /
    • v.17 no.3
    • /
    • pp.319-326
    • /
    • 2010
  • In this paper, a new group sampling plan for the lot acceptance is proposed for the time truncated life test, which can be utilized when multi-item testers are implemented. The design parameters are found using the two-point approach such that the producer's and consumer's risks are satisfied simultaneously at the acceptable reliability level and the lot tolerance reliability level, respectively. The case of Weibull distribution is described to illustrate the procedure that can be used when the quality level is expressed by a multiple of the specified life. The advantage of the proposed plan is demonstrated by comparing with the existing plan in terms of the sample size required. The tables are constructed and some examples are given to illustrate the procedure developed here.

Real-time Volume Rendering using Point-Primitive (포인트 프리미티브를 이용한 실시간 볼륨 렌더링 기법)

  • Kang, Dong-Soo;Shin, Byeong-Seok
    • Journal of Korea Multimedia Society
    • /
    • v.14 no.10
    • /
    • pp.1229-1237
    • /
    • 2011
  • The volume ray-casting method is one of the direct volume rendering methods that produces high-quality images as well as manipulates semi-transparent object. Although the volume ray-casting method produces high-quality image by sampling in the region of interest, its rendering speed is slow since the color acquisition process is complicated for repetitive memory reference and accumulation of sample values. Recently, the GPU-based acceleration techniques are introduced. However, they require pre-processing or additional memory. In this paper, we propose efficient point-primitive based method to overcome complicated computation of GPU ray-casting. It presents semi-transparent objects, however it does not require preprocessing and additional memory. Our method is fast since it generates point-primitives from volume dataset during sampling process and it projects the primitives onto the image plane. Also, our method can easily cope with OTF change because we can add or delete point-primitive in real-time.

Evaluation of Sample Testing Scheme for Designated Aquatic Animals (수산동물 지정검역물에 대한 표본검사 계획 검토)

  • Pak, Son-Il
    • Journal of Veterinary Clinics
    • /
    • v.29 no.1
    • /
    • pp.58-62
    • /
    • 2012
  • To protect aquatic animal health of importing countries from the potential risks associated with exotic diseases introduced through international trade of live aquatic animals, inspection of designated commodities at ports of entry is a critical component of the safeguarding system. The only way to be 100% confident that no fishes in a shipment are infected with a specific agent is to test every fish in the commodity imported with a perfect diagnostic test. For the majority of cases, this is unrealistic since the group of interest may very large particularly for aquatic animals, or imperfect tests are often available. It is, therefore, more common to test a fixed proportion of a group by preplanned sampling schemes. However, decision making based on results of testing the sample can provide quite a chance that infected groups may be misclassified as uninfected, depending on sampling strategy employed. The objective of this study was to determine the possibility that one or more fishes in the group imported being infected but tests negative after inspecting samples. This question is critical to government authorities to examine whether sampling plan is sufficient to achieve the purpose intended for. At fixed population size, the maximum number of infected fishes when all tests negative was decreased as the sampling fraction increased. The probability of including at least one undetected but infected fish in a group for negative tests increased with the number of fish tested or true prevalence. The risk was much lesser where high sensitivity test was assumed; when increasing test sensitivity from 0.9 to 0.99, this risk was dramatically reduced to about a tenth or a fourth for prevalence ranges from 2 to 10%, given sample size ranges from 10 to 200. Based on the preliminary analysis, the author concluded that current sampling plan testing 4-8% of the import proposal for human consumption still can yield high false negative results. Therefore, from the quarantine inspection point of view, an enforced commodity-specific sampling design that accounts for the cost of testing with an imperfect test at the specified design prevalence is urgent.