• Title/Summary/Keyword: Sample preparations

Search Result 74, Processing Time 0.028 seconds

Studies on the Spectrophotometric Determination of Gentamicin Sulfate and its Preparations (분광광도법에 의한 제제중 Gentamicin Sulfate의 정량에 관한 연구)

  • 이진호;양호석;이윤중
    • YAKHAK HOEJI
    • /
    • v.27 no.1
    • /
    • pp.45-52
    • /
    • 1983
  • The ability of gentamicin to form a stable coloured complex with copper (II) in a sodium carbonate buffer solution, which had a maximum absorption at 694nm, was used for the spectrophotometric quantitative determination of gentamicin sulfate. The calibration curve obtained was linear over the range of 200~2,000mcg per ml of the sample and the analysis was very well agreed with the microbiological method.

  • PDF

Optimization of the Reduced-Calorie Yellow Layer Cake Preparations (저열량 레이어 케익 제조 공정의 최적화)

  • Kim, Yang-Hwa;L.Kim, Hye-Young
    • Journal of the Korean Society of Food Culture
    • /
    • v.18 no.1
    • /
    • pp.37-44
    • /
    • 2003
  • Fat and sugar reduced yellow layer cake system was developed with varied replacement level of 30%, 60%, and 90% for AD(amylodextrin) and 10%, 30%, and 50% for PD(polydextrose). Physicochemical and sensory characteristics were investigated and optimum replacement level was also decided using response surface methodology. Sample groups of PD10AD30 had significantly the lowest specific gravity and viscosity, indicating the stable batter system with high air incorporation. Sample groups with PD10AD90 showed the highest volume index and were not significantly different from those of the PD10AD30. Sensory results indicated that PD30AD30 were significantly the most springy and moist, and the least hard of all sample groups. Sample groups with PD10AD90 had the least adhesiveness value. To establish the optimum substitution level using RSM, the restriction level was set up as moistness over five point, hardness under five points, and adhesiveness under four points. The optimum substitution level was 20% for PD and 88% for AD.

Direct Analysis of Organic Additives in Cured Rubber by Pyrolysis-Gas Chromatography/Mass Spectrometry (열분해-가스크로마토그래피/질량분석법에 의한 가황고무중의 유기첨가제의 직접분석)

  • Kim, Seung Wook;Heo, Gwi Suk;Lee, Gae Ho
    • Journal of the Korean Chemical Society
    • /
    • v.41 no.10
    • /
    • pp.524-534
    • /
    • 1997
  • Analysis of additives in cured rubber is often a difficult task for analytical chemists because of a wide variety of complex components. Conventional analyses of additives and rubbers have been done in multistep, off-line processes with large sample size and extensive sample preparations. The coumarone-indene resin, resorcinol-formaldehyde resin, and prevulcanization inhibitor have been characterized by their pyrolysis pathways and mass spectra of characteristic pyrolyzates. Pyrolysis Gas Chromatography/Mass Spectrometry (Py-GC/MS) was used in the identification of additives without any sample pretreatment. This result shows that several organic additives in cured rubber can be directly analyzed.

  • PDF

Measurement of Alcohol Contents in Alcoholic Beverages Using a Surface Plasmon Resonance Sensor (표면 플라즈몬 공명 센서를 이용한 주류의 알코올 함량 측정)

  • 조용진;안병학;김철진;김종태
    • Journal of Biosystems Engineering
    • /
    • v.29 no.4
    • /
    • pp.323-328
    • /
    • 2004
  • A surface plasmon resonance (SPR) sensing system, which belonged to a family of thin film refractometry-based sensors, was fabricated to measure the alcohol contents in alcoholic beverages. In this study, a SPR owe was obtained by a photodiode array with 128 pixels and transformed into a refractive index which was calculated by means of the first moment of values below a baseline of 0.85. When the sensing system was applied to Soju, Cheonju, Igwaduju and Tacju highly linear relationships between the refractive index by SPR and the contents of alcohol were obtained. That is, the coefficients of determination in their linear models were 0.992, 0.933, 0.918 and 0.954, respectively. Meanwhile, the effect of sample preparations on the accuracy of measurement was analyzed. As for Soju and Tacju, the best calibration equations were obtained when no sample preparation was applied. The best calibration models for measurement of Cheonju and Igwaduju were obtained through the samples filtered by $C_{18}$ disks.

Studies on Pharmaceutical Quality of Oriental Medicinal Preparations (I) - Studies on Decoction of Nokyong-Sagunja-Tang - (한방방제의 제제학적 연구(1) - 추출방법에 따른 녹용사군자탕의 비교 -)

  • Choi, Hyuck-Jae;Kim, Eun-Jin;Kim, Sung-Soo;Kim, Nam-Jae
    • Korean Journal of Pharmacognosy
    • /
    • v.37 no.3
    • /
    • pp.143-150
    • /
    • 2006
  • Decoction of oriental medicinal preparation is prepared in various manners, and changes of chemical constituents might be occurred depending on the processing techniques. The present study was undertaken to investigate the phγsio-chemical and pharmacological equivalence between two extraction methods of Nokyong-sagunja-Tang. Samples were Prepared as follows ; Sample-I was prepared by simultaneously extracting Sagunja-Tang and velvet antler in one vessel. Sample-lI was prepared by adding velvet antler exact to the water extract of Sagunja-Tang. Both sanples showed similar results of physiochemical parameters such as pH, yield, TLC and HPLC chromatogram, and contents of ginsenoside $Rb_1$ and glycyrrhizin. Also, there were little different between two samples in pharmacological effects such as DPPH free radical scavenging effect, and inhibitory effects on xanthine oxidase, hyaluronidase, trypsin, TBA-Rs formation and hemolysis in vitro. And both samples showed no significant difference in antifatigue activities in mice. These results suggest that there might be little difference between two extraction process when velvet antler added to Sagunia-Tang.

Characterizations of Two-step Matrix Application Procedures for Imaging Mass Spectrometry

  • Shimma, Shuichi
    • Mass Spectrometry Letters
    • /
    • v.6 no.1
    • /
    • pp.21-25
    • /
    • 2015
  • In this paper, I describe the importance of matrix spraying conditions in imaging mass spectrometry (IMS) to obtain successful imaging results. My developed matrix application methodology, which is a "two-step matrix application" sequentially combined with matrix sublimation and spraying matrix solution can provide high reproducibility and high ion yield compared with a conventional direct spraying method. However, insufficient IMS results were obtained occasionally despite the two-step method. Therefore, I wanted to characterize the methodology to continuously provide high quality data. According to my results, the sublimation time was not a strict parameter, and the most important step was the first spraying condition. This means that the extraction conditions from the tissue section and co-crystallization of the matrix were the most important factors.

Preparations of ASC Refractory Materials from Kaolin using Thermit Reaction (카오린으로부터 테르밋 반응을 통한 $Al_2O_3-SiC-C(ASC)$계 내화재료 합성)

  • 이온영;이용구;전병세
    • Journal of the Korean Ceramic Society
    • /
    • v.32 no.4
    • /
    • pp.429-435
    • /
    • 1995
  • Al2O3-SiC-C(ASC) refractory materials were prepared from kaolin using thermit reaction. The mixed powder (A-K) for the thermit reaction was composed of Hadong kaolin, C(graphite) and Al. A-S(SiO2+C+Al) composition was also employed to compare with A-K in respect to reactability. As a result of XRD patterns of A-K sample after thermit reaction, and firing at 140$0^{\circ}C$ for 3hrs in Ar atmosphere, it was possible to use as a ASC refractory materials.

  • PDF

Nerve Agents and Their Detection

  • Kim, Young Jun;Huh, Jae Doo
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.4
    • /
    • pp.217-223
    • /
    • 2014
  • Nerve agents are major chemical warfare agents with the "G series" and "V series" being the most widely known because of their lethal effect. Although not conspicuously used in major wars, the potential detrimental impact on modern society had been revealed from the sarin terror attack on Tokyo subway, which affected thousands of people. In this mini-review, major nerve agents of the "G series" and "V series" have been described along with various types of their detection methods. The physical properties and hydrolysis mechanisms of the major nerve agents are discussed since these are important factors to be considered in choosing detection methods, and specifying the procedures for sample preparations in order to enhance detection precision. Various types of extraction methods, including liquid-phase, solid-phase, gas-phase and solid-phase microextraction (SPME), are described. Recent development in the use of gas sensors for detecting nerve agents is also summarized.

NMR methods for structural analysis of RNA: a Review

  • Kim, Nak-Kyoon;Nam, Yun-Sik;Lee, Kang-Bong
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.18 no.1
    • /
    • pp.5-9
    • /
    • 2014
  • In last three decades, RNA molecules have been revealed to play the central roles in many cellular processes. Structural understanding of RNA molecules is essential to interpret their functions, and many biophysical techniques have been adopted for this purpose. NMR spectroscopy is a powerful tool to study structures and dynamics of RNA molecules, and it has been further applied to study tertiary interactions between RNA molecules, RNA-protein, and RNA-small molecules. This short article accounts for the general methods for NMR sample preparations, and also partially covers the resonance assignments of structured RNA molecules.

Invasive and non-invasive methods for estimating the optical properties of tissue at laser wavelengths (레이저 파장에서의 생체 침습적 및 비침습적 광학계수 측정 방법)

  • Yoon, Gil-Won
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1994 no.12
    • /
    • pp.147-150
    • /
    • 1994
  • To predict light propagation in biological tissues irradiated by laser, the optical properties such as absorption and scattering coefficients are required. There have been various techniques for measuring these coefficients. One method requires tissue samples, often a slab of thin tissue, is invasive. On the other hand, non-invasive method usually measures back-scattered light from a subject with no physical intervent ions. Advantages and disvantages of using different methods are investigated. A careful attention should be made in order to select the best method for a given experimental condition since, even either for invasive or non-invasive method, accuracy is subject to governing models and sample preparations.

  • PDF