• 제목/요약/키워드: Sample array

검색결과 206건 처리시간 0.026초

The Ground Checkout Test of OSMI on KOMPSAT-1

  • Yong, Sang-Soon;Shim, Hyung-Sik;Heo, Haeng-Pal;Cho, Young-Min;Oh, Kyoung-Hwan;Woo, Sun-Hee;Paik, Hong-Yul
    • 대한원격탐사학회지
    • /
    • 제15권4호
    • /
    • pp.297-305
    • /
    • 1999
  • Ocean Scanning Multispectral Imager (OSMI) is a payload on the KOMPSAT satellite to perform global ocean color monitoring for the study of biological oceanography. The instrument images the ocean surface using a wisk-broom motion with a swath width of 800km and a ground sample distance (GSD) of < 1km over the entire field of view (FOV). The instrument is designed to have an on-orbit operation duty cycle of 20% over the mission lifetime of 3 years with the functions of programmable gain/offset and on-board image data compression/storage. The instrument also performs sun and dark calibration for on-board instrument calibration. The OSMI instrument is a multi-spectral imager covering the spectral range from 400nm to 900nm using CCD Focal Plane Array (FPA). The ocean colors are monitored using 6 spectral channels that can be selected via ground commands. KOMPSAT satellite with OSMI was integrated and the satellite level environment tests including instrument aliveness/functional test, such as launch environment, on-orbit environment (Thermal/Vacuum) and EMI/EMC test were performed at KARl. Test results met the requirements and the OSMI data were collected and analyzed during each test phase. The instrument is launched on the KOMPSAT satellite on December 21,1999 and is scheduled to start collecting ocean color data in the early 2000 upon completion of on-orbit instrument checkout.

Quantification of the Bioactive Components of the Rhizomes of Curcuma wenyujin and Assessment of Its Anti-inflammatory Effect in Benign Prostatic Hyperplasia-1 Cells

  • Seo, Chang-Seob;Park, Eunsook;Lee, Mee-Young;Shin, Hyeun-Kyoo
    • Natural Product Sciences
    • /
    • 제25권3호
    • /
    • pp.238-243
    • /
    • 2019
  • In this study, the marker compounds of Curcumae Rhizoma (CR) were simultaneously quantified by high-performance liquid chromatography equipped with a photodiode array detector and the anti-inflammatory effects of CR extract and marker compounds in human benign prostatic hyperplasia epithelial-1 (BPH-1) cell lines were investigated. The marker components (4S,5S)-(+)-germacrone-4,5-epoxide, furanodienone, and germacrone, were separated on Gemini $C_{18}$ columns ($250mm{\times}4.6mm$, $5{\mu}m$) at $40^{\circ}C$ by using a gradient of two mobile phases eluting at 1.0 mL/min. Prostaglandin $E_2$ ($PGE_2$) levels in Human BPH-1 cells were determined with an ELISA kit. The coefficients of determination in a calibration curve of each analyte were all 0.9997. The limits of detection and quantification of the three compounds were $0.10-0.32{\mu}g/mL$ and $0.30-0.98{\mu}g/mL$, respectively. The content of three compounds, (4S,5S)-(+)-germacrone-4,5-epoxide, furanodienone, and germacrone, in the CR sample were found to be 5.79 - 5.92 mg/g, 4.72 - 4.86 mg/g, and 1.06 - 1.09 mg/g, respectively. Regarding pharmacological activity against benign prostatic hyperplasia, CR and its components significantly suppressed $PGE_2$ levels of BPH-1 cells. The established analysis method will help to improve quality assessment of CR samples and related products. In addition, CR and its components exhibit antiinflammatory activity in BPH-1 cells, suggesting the inhibitory efficacy of these compounds against the pathogenesis of BPH.

몬테카를로 시뮬레이션을 이용한 복숭아의 방사선 조사 (Monte Carlo Simulation of Irradiation Treatment of Peaches (Prunus persica L. Batsch))

  • 김종순;김동현;박종민;최원식;권순홍
    • 한국산업융합학회 논문집
    • /
    • 제21권6호
    • /
    • pp.337-344
    • /
    • 2018
  • Food irradiation is important not only in ensuring safety but also improving antioxidant activity of peaches. Our objective was to establish the best irradiation treatment for peaches by calculating dose distribution using Monte Carlo simulation. 3-D geometry and component densities of peaches, extracted from CT scan, were entered into MCNP to obtain simulated dose distribution. Radiation energies for electron beam were 1.35 MeV (low energy) and 10 MeV (high energy). Co (1.25 MeV) and the Husman irradiator, containing three sealed Cs source rods in an annular array, were used for gamma irradiation. At 1.35 MeV electron beam simulation, electrons penetrated well beyond the peach skin, enough for surface treatment for microorganisms and allergens. At 10 MeV electron beam simulation, for top-beam only treatment, doses at the core were the highest and for double beam treatment, the electron energy was absorbed by the entire sample. At Co source, the radiation doses were presented on the whole area. At Cs source, the dose uniformity ratios were 2.78 for one source and 1.48 for three ones at 120 degrees interval. Proper control of irradiation treatment is critical to establish confidence in the irradiation process.

A Latent Factor (PLS-SEM) Approach: Assessing the Determinants of Effective Knowledge Transfer

  • ANJUM, Reham;KHAN, Hadi Hassan;BANO, Safia;NAZIR, Sidra;GULRAIZ, Hira;AHMED, Wahab
    • The Journal of Asian Finance, Economics and Business
    • /
    • 제8권2호
    • /
    • pp.851-860
    • /
    • 2021
  • The Knowledge Transfer (KT) for higher education institutions (HEIs) is boundless. Still and all, the members of the staff affiliated with these institutions do recognize an array of hitches in relation to KT practices. The study in question underscores social interactions, training, and Information and Communication Technology (ICT) as the primary barriers and treats them as the independent variables of the study. The study posits that inadequate management of the above-mentioned barriers would impact effective KT unfavorably. Besides, putting forth some striking solutions needed to fix the obstructions that hamper the adequate management of the KT exercises is another aim of the study. For data collection purposes, the study picks out higher education institutions (public) of the Quetta district. The reckoned sample size is 317 subjects. The research type that has been used is cross-sectional research and, in this context, the cross-sectional explanatory sequential design has been used. Concerning the findings of the paper, the results of PLS-SEM show positive and significant relationships of social interaction and training with knowledge transfer, while ICT shows an insignificant positive relationship with the knowledge transfer. The most influencing factor for the knowledge transfer is social interaction as suggested by social interaction theory.

Discrimination of biological and artificial nicotine in e-liquid

  • Hyoung-Joon Park;Heesung Moon;Min Kyoung Lee;Min Soo Kim;Seok Heo;Chang-Yong Yoon;Sunyoung Baek
    • 분석과학
    • /
    • 제36권1호
    • /
    • pp.22-31
    • /
    • 2023
  • As the use of e-liquid cigarettes is rapidly increasing worldwide, it multiplies the potential risk undisclosed to the health of non- and smokers. To reduce the hazard, each country has its own set of regulations for controlling e-liquids. In Korea, the narrow definition of tobacco makes it difficult and have been steadily occurring tax evasion exploiting the difference in natural and artificial nicotine. Therefore, it is very important to distinguish source of nicotine for their regulation. To find biochemical discriminant markers, this study established analysis methods based on high-performance liquid chromatography coupled with diode array detector (HPLC-DAD) and high-performance liquid chromatography coupled with triple Quadrupole mass spectrometry (HPLC-MS/MS) for nicotine enantiomers and tobacco alkaloids targeted using the difference in pathways of nicotine biosynthesis and chemical synthesis. The method was validated by experimenting linearity (R2 > 0.999), recovery (80.99-108.41 %), accuracy (94.11-109.73 %) and precision (0.04-8.27 %). Then, the results for discrimination of the nicotine obtained from analysis of 65 commercial e-liquid products available in Korean market was evaluated. The method successfully applied to the e-liquids and one sample labelled 'synthetic nicotine' for tax exemption was found to contain a natural nicotine product. This method can be used to determine whether an e-liquid product uses natural or artificial nicotine and monitor non-taxable e-liquid products. The method is more scientific than the existing one, which relies only on field evidence.

Genetic structure analysis of domestic companion dogs using high-density SNP chip

  • Gwang Hyeon Lee;Jae Don Oh;Hong Sik Kong
    • 한국동물생명공학회지
    • /
    • 제39권2호
    • /
    • pp.138-144
    • /
    • 2024
  • Background: As the number of households raising companion dogs increases, the pet genetic analysis market also continues to grow. However, most studies have focused on specific purposes or native breeds. This study aimed to collect genomic data through single nucleotide polymorphism (SNP) chip analysis of companion dogs in South Korea and perform genetic diversity analysis and SNP annotation. Methods: We collected samples from 95 dogs belonging to 26 breeds, including mixed breeds, in South Korea. The SNP genotypes were obtained for each sample using an AxiomTM Canine HD Array. Quality control (QC) was performed to enhance the accuracy of the analysis. A genetic diversity analysis was performed for each SNP. Results: QC initially selected SNPs, and after excluding non-diverse ones, 621,672 SNPs were identified. Genetic diversity analysis revealed minor allele frequencies, polymorphism information content, expected heterozygosity, and observed heterozygosity values of 0.220, 0.244, 0.301, and 0.261, respectively. The SNP annotation indicated that most variations had an uncertain or minimal impact on gene function. However, approximately 16,000 non-synonymous SNPs (nsSNPs) have been found to significantly alter gene function or affect exons by changing translated amino acids. Conclusions: This study obtained data on SNP genetic diversity and functional SNPs in companion dogs raised in South Korea. The results suggest that establishing an SNP set for individual identification could enable a gene-based registration system. Furthermore, identifying and researching nsSNPs related to behavior and diseases could improve dog care and prevent abandonment.

The importance of NIR spectroscopy in the estimation of nutritional quality of grains for ruminants

  • Flinn, Peter C.
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1612-1612
    • /
    • 2001
  • The production of grain for export and domestic use is one of Australia's most important agricultural industries, and the NIR technique has been used extensively over many years for the routine monitoring of grain quality, particularly moisture and protein content. Because most Australian grain is intended for human food production, the determinants of grain quality for livestock feed, apart from protein, have been largely ignored. However the increasing use of grain for feeding to pigs, poultry, beef cattle and dairy cows has led to an important national research project entitled “Premium Grains for Livestock”. Two of the objectives of this project are to determine the compositional and functional characteristics of grains which influence their nutritional quality for the various classes of livestock, and to adopt rapid and objective analytical tests for these quality criteria. NIR has been used in this project firstly to identify a set of grain samples from a large population of breeders' lines which showed a wide spectral variation, and hence a potentially wide variation in nutritional value. The selected samples were not only subjected to an extensive array of chemical, physical and in vitro analyses, but also were grown out to produce sufficient quantities of grain to feed to animals in vivo studies. Additional grains were also strategically selected from farms in order to include the effect of weather damage, such as rain, drought and frost. In this study to date, NIR calibrations have been derived or attempted, on both ground and whole grains, for in vivo dry matter digestibility (DMD), pepsin-cellulase dry matter disappearance, protein, fat, acid detergent fibre, neutral detergent fibre, starch, in sacco DMD and in vitro assays to simulate starch digestion in the lumen and small intestine. Results so far indicate high calibration accuracy for chemical components (SECV 0.3 to 2.6%) and very promising statistics for in vivo DMD (SECV 1.8, $R^2$ 0.93, SD 7.0, range 61.9 to 92.3, n=60). There appears to be some potential for NIR to estimate some in vitro properties, depending upon the accuracy of reference methods and appropriate sample populations. Current work is in progress to extend the range of grains with in vivo DMD values (a very laborious and expensive process) and to increase the robustness of the various NIR calibrations, with the aim of implementing uniform testing procedures for nutritional value of grains throughout Australia.

  • PDF

Effects of variety, region and season on near infrared reflectance spectroscopic analysis of quality parameters in red wine grapes

  • Esler, Michael B.;Gishen, Mark;Francis, I.Leigh;Dambergs, Robert G.;Kambouris, Ambrosias;Cynkar, Wies U.;Boehm, David R.
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1523-1523
    • /
    • 2001
  • The wine industry requires practical methods for objectively measuring the composition of both red wine grapes on the vine to determine optimal harvest time; and of freshly harvested grapes for efficient allocation to vinery process streams for particular red wine products, and to determine payment of contract grapegrowers. To be practical for industry application these methods must be rapid, inexpensive and accurate. In most cases this restricts the analyses available to measurement of TSS (total soluble solids, predominantly sugars) by refractometry and pH by electropotentiometry. These two parameters, however, do not provide a comprehensive compositional characterization for the purpose of winemaking. The concentration of anthocyanin pigment in red wine grapes is an accepted indicator of potential wine quality and price. However, routine analysis for total anthocyanins is not considered as a practical option by the wider wine industry because of the high cost and slow turnaround time of this multi-step wet chemical laboratory analysis. Recent work by this ${group}^{l,2}$ has established the capability of near infrared (NIR) spectroscopy to provide rapid, accurate and simultaneous measurement of total anthocyanins, TSS and pH in red wine grapes. The analyses may be carried out equally well using either research grade scanning spectrometers or much simpler reduced spectral range portable diode-array based instrumentation. We have recently expanded on this work by collecting thousands of red wine grape samples in Australia. The sample set spans two vintages (1999 and 2000), five distinct geographical winegrowing regions and three main red wine grape varieties used in Australia (Cabernet Sauvignon, Shiraz and Merlot). Homogenized grape samples were scanned in diffuse reflectance mode on a FOSE NIR Systems6500 spectrometer and subject to laboratory analysis by the traditional methods for total anthocyanins, TSS and pH. We report here an analysis of the correlations between the NIR spectra and the laboratory data using standard chemometric algorithms within The Unscrambler software package. In particular, various subsets of the total data set are considered in turn to elucidate the effects of vintage, geographical area and grape variety on the measurement of grape composition by NIR spectroscopy. The relative ability of discrete calibrations to predict within and across these differences is considered. The results are then used to propose an optimal calibration strategy for red wine grape analysis.

  • PDF

식품중 불법함유된 발기부전치료제 성분 검출을 위한 동시분석법 연구 (Simultaneous Identification/Determination System for Sildenafil, Homosildenafil, Vardenafil and Tadalafil as Adulterants in Foods)

  • 장재희;박건상;박혜경;구용의;최윤주;황인경;김대병
    • 한국식품위생안전성학회지
    • /
    • 제18권4호
    • /
    • pp.195-201
    • /
    • 2003
  • 본 연구에서는 국내 ${\cdot}$ 외에서 유통되는 건강관련식품 중 성기능 개선 및 효과에 대하여 광고 ${\cdot}$ 판매하고 있는 제품들에 대하여 최근 의약품으로 허가된 발기부전치료제인 sildenafil, vardenafil, tadalafil 및 sildenafil의 유사물질인 homosildenafil을 대상으로 정성과 정량을 위한 동시분석법을 개발하고 유통 제품 중의 함량을 분석하여 함유 실태를 파악하고자 하였다. 네 가지 성분을 확인할 수 있는 TLS와 LC/MS 분석방법을 개발하였으며, LC/PDA를 사용한 동시 정량분석법을 개발하고, 건강보조식품 등 건강관련 식품중 sildenafil 등 4종 물질에 대해 총 35개의 시료를 분석한 결과 sildenafil이 7종에서 0.4 mg/g~360.9 mg/g, homosildenafil이 7종에서 2.2 mg/g~336.0 mg/g, tadalafid이 2종에서 각각 19.2mg/g, 429.3mg/g로 검출되었으며, 본 여구에서 개발한 동시분석법을 유통식품에 적용 가능하였다.

한국 후천적 시각장애인의 우울과 영향요인에 관한 연구 (Examining depressive symptoms of visually impaired adults in Korea)

  • 김혜미
    • 한국산학기술학회논문지
    • /
    • 제17권7호
    • /
    • pp.666-676
    • /
    • 2016
  • 본 연구의 목적은 후천적 시각장애인에 대한 우울 실태와 이들의 우울에 영향을 미치는 요인을 규명하는 것으로 이를 위해 본 연구에서는 장애인실태조사 2014 자료를 활용하여 분석을 실시하였다. 연구대상자는 출생 1년 이후부터 시각장애를 가지게 된 20~60세 사이의 성인이며 최종 분석에 포함된 대상자 수는 235명이다. 다중로지스틱회귀분석 실시 결과, 후천적 시각장애인의 약 20%가 우울증상을 경험한 것으로 나타났으며, 우울증상 경험을 예측하는 요인으로는 인구사회학적 요인 중에서는 연령, 성별, 결혼여부가 유의한 요인으로 나타났으며 건강 관련 요인으로는 흡연여부, 일상생활 스트레스 수준, 주관적 건강상태가 유의한 요인으로 파악되었다. 장애관련 요인으로는 장애기간 및 일상생활 수행능력 수준이 유의한 예측요인으로 밝혀졌다. 종합적으로 본 결과는 국내 거주하는 후천적 성인 시각장애인의 많은 수가 우울과 같은 심리적 어려움에 노출되어 있으며, 이를 위한 예방 및 개입 방안 마련이 시급함을 알려준다. 아직까지 장애인 복지 및 장애인 대상 서비스 분야에서 이들에 대한 관심 및 서비스 마련이 미흡한만큼 추후 중도에 실명 혹은 시각손실을 경험하게 된 장애인에 대한 제도적인 고려가 요구된다.