• Title/Summary/Keyword: Salt water immersion

Search Result 48, Processing Time 0.021 seconds

FACTORS INVOLVED IN THAWING OF FROZEN ALASKA POLLACK AND REFREEZING OF THE FILLET (명태 FILLET 제조를 위한 냉동원료의 해동방법과 가공품의 재동결방법에 관한 연구)

  • CHOE Wi-Kyung;PARK Yung-Ho;LEE Kang-Ho;CHANG Dong-Suck;KIM Mu-Nam
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.8 no.2
    • /
    • pp.107-117
    • /
    • 1975
  • Alaska pollack caught in the Northern Pacific Ocean and frozen aboard vessel are skipped to the plant and processed into frozen fillets. In the present paper quality changes during thwaing, refreezing and storage at $-20^{\circ}C$ are discussed. Natural, running-water, vacuum and steam thawing were employed as thawing methods. And contact plate, air blast, immersion in dry ice-alcohol solution freezing and storage at $-5^{\circ}C$ were applied to refreeze the thawed fillets. As quality factors content of drip released, salt-extractable protein, VBN, DNA in the drip and pH were determined. In addition, bacteriological tests were also carried out along with the whole process. In thawing of round material, the vacuum thawing was more effective than any other method, resulting in drip, salt-extractable protein $(N\%)$, VBN and DNA as $4.4\%,\;1.82\%,\;16.21mg\%$ and $13.70\;{\mu}g/ml$, respectively. Storage at $-5^{\circ}C$ as refreezing method yielded lower in drip and DNA content but similar to or slightly higher in both salt-extractable protein and VBN, which might postulate that the quality of the frozen fillet depends not largely on the secondary freezing but on the conditions of thawing and primary freezing. It seemed that most of the bacterial flora in thawed fillet came from skin and viscera of fish, worker's hands, utensils and other processing facilities, since sanitary indicative bacteria were not detected in the frozen flesh of round Alaska pollack. Bacterial quality of fillet varied with thawing methods, vacuum thawing appeared more sanitative compared with other methods as natural, running-water, and steam thawing. Bacterial colonies isolated from the thawed fillet were composed of $73.8\%$ Gram negative rod shape, $4.9\%$ Gram positive rod shape, $18.0\%$ cocci, and $3.3\%$ yeast. Decreasing rate of coliform group of the fillet during the storage at $-20^{\circ}C$ for 30 days was more than $70\%$ and that of plate count was less than of coliform group.

  • PDF

Preparation of highly hydrophobic PVDF hollow fiber composite membrane with lotus leaf-like surface and its desalination properties

  • Li, Hongbin;Zi, Xingchen;Shi, Wenying;Qin, Longwei;Zhang, Haixia;Qin, Xiaohong
    • Membrane and Water Treatment
    • /
    • v.10 no.4
    • /
    • pp.287-298
    • /
    • 2019
  • Lotus leaf has a special dual micro and nano surface structure which gives its highly hydrophobic surface characteristics and so-called self cleaning effect. In order to endow PVDF hollow fiber membrane with this special structure and improve the hydrophobicity of membrane surface, PVDF hollow fiber composite membranes was obtained through the immersion coating of poly(vinylidene fluoride-co-hexafluoropropylene) (PVDF-HFP) dilute solution on the outside surface of PVDF support membrane. The prepared PVDF composite membranes were used in the vacuum membrane distillation (VMD) for the desalination. The effects of PVDF-HFP dilute solution concentration in the dope solution and coating time on VMD separation performance was studied. Membranes were characterized by SEM, WCA measurement, porosity, and liquid entry pressure of water. VMD test was carried out using $35g{\cdot}L^{-1}$ NaCl aqueous solution as the feed solution at feed temperature of $30^{\circ}C$ and the permeate pressure of 31.3 kPa. The vapour flux reached a maximum when PVDF-HFP concentration in the dilute solution was 5 wt% and the coating time was kept in the range of 10-60 s. This was attributed to the well configuration of micro-nano rods which was similar with the dual micro-nano structure on the lotus leaf. Compared with the original PVDF membrane, the salt rejection can be well maintained which was greater than 99.99 % meanwhile permeation water conductivity was kept at a low value of $7-9{\mu}S{\cdot}cm^{-1}$ during the continuous testing for 360 h.

Radiation Grafting of Hydrophilic Monomers onto Polyester

  • Park, Jae-Ho;Lee, Chong-Kwang;Lee, Kwang-Jin
    • Nuclear Engineering and Technology
    • /
    • v.5 no.2
    • /
    • pp.103-114
    • /
    • 1973
  • Radiation grafting of acrylic acid and 4-vinylpyridine at room temperature has been studied by an impregnation method to improve the hygroscopic properties, the antistatic behavior and the dyeability of polyester fabric. Polyester fabric was impregnated with acrylic acid or aqueous emulsion of acrylic acid-4-vinylpyridine by immersion at 25$^{\circ}$or 7$0^{\circ}C$. The impregnated fabric was irradiated under nitrogen gas with ${\gamma}$-rays from Co-60. When acrylic acid grafted polyester fabric was treated with sodium carbonate, calcium acetate and potassium persulfate, tne rate of water absorption was increased and most parts of polyacrylic acid formed were extracted off from the fabric with 0.1% solution of sodium hydroxide at 10$0^{\circ}C$. In the case of the impregnation of a mixture of acrylic acid and 4-vinylpyridine the petcent of grafting has been shown to be proportional to the ratio of 4-VP/AA and radiation dost. Estimating by contact angle measurements of water on the various polymer surfaces, the antistatic behavior was decreased with the increase of grafting percent. The investigation of electron micrograph disclosed the existence of certain type of discontinuities in the acrylic acid grafted polyester fiber which was treated with various salts.

  • PDF

Effect of manufacturing process using superheated steam on the quality improvement of pickled radish product (과열증기를 이용한 무우절임 제품의 제조공정 설정 및 품질 개선효과)

  • Kim, Eunmi;Lim, Jeong-Ho;Choi, Yun-Sang;Jeon, Ki-Hong
    • Food Science and Preservation
    • /
    • v.24 no.5
    • /
    • pp.600-607
    • /
    • 2017
  • This study was conducted to develop radish as a food product for home meal replacement using superheated steam (SHS). Also, the change of quality characteristics was studied during their storage. The radish cuts were treated with SHS for 0, 3, 5, and 7 min, respectively, followed by complete drying at $80^{\circ}C$ for 6 hours. The results showed that radishes restored with mixed solution (drinking water:sugar:vinegar:salt=2:1:0.8:0.1) were harder than those restored with drinking water. All radishes were stored at 5, 10 and $15^{\circ}C$ for 56 days to investigate the changes of quality characteristics during the storage. Radishes in the control group, restored with drinking water and stored at $15^{\circ}C$, were spoiled after 7 days of storage. The radish in the experimental group did not show any change in the water content; except an increase on the first day of storage. The hardness of radish decreased with an increase in the storage period. It was found that microbial growth was inhibited due to low pH of the mixed solution, in which radishes of the experimental group were immerse.

A Study on Mitigation of Rail Corrosion using Sacrificial Anode Cathodic Protection Method (희생양극법을 이용한 레일부식 저감 방안에 관한 연구)

  • Choi, Jung-Youl;Kim, Jun-Hyung;Lee, Kyu-Yong;Kim, Young-Ki;Park, Jong-Yoon;Song, Bong-Hwan;Seol, Jin-Woong
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.6
    • /
    • pp.54-60
    • /
    • 2017
  • A railway rail will be corroded by the repetitive sea wind and fog in the splash and tidal zone such as Youngjong grand bridge. And these rusts of rail could be increased by increasing service period, and it frequently occurred the safety accidents or disorders in electrical problem. In this study, the sacrificial anode cathodic protection method was proposed as a measures for reducing the corrosion of the railway rails in the oceanic climate conditions. As the results of immersion test using the salt water during four months, the sacrificial anode cathodic protection method using the aluminum anode(Al-anode) was evaluated that a distinct effect on corrosion reduction in the rails. Therefore the sacrificial anode cathodic protection method was experimentally proven that a disorders in aspects electric and signal of railway operation condition such as direct fixation track system in Youngjong grand bridge could be prevented by reducing rust falling from the rail. In addition, the installation conditions of the anodes directly affect the transmission range of corrosion potential, the sectional loss of anode, and the corrosion reduction effect. Therefore, to expect the corrosion reduction effect of rails under the oceanic climate conditions for railway track, it was important to adopted the appropriate spacing of anode installation by considering the actual field conditions.

Deposition and Corrosion Resistance of Electrophoretic Paint Coated on AZ61 and TZ61 Magnesium Alloys

  • Van Phuong, Nguyen;Moon, Sungmo
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2015.05a
    • /
    • pp.32-32
    • /
    • 2015
  • Electrophoretic paint (E-paint) was investigated on four different magnesium substrates: as-extruded AZ61 (AZ61), heat-treated AZ61 (AZ61-H), as-extruded TZ61 (TZ61) and heat-treated TZ61 (TZ61-H), to elucidate the effect of heat treatment and alloying elements on the deposition and corrosion resistance of E-paint. It was found that, a rapid increase of voltage, indicating that the deposition of E-paint had started, was observed after an induction time of 0.39 min for AZ61-H, 0.43 min for AZ61, 0.51 min for TZ61-H and 0.58 min for TZ61. The amount of E-paint deposited on the four samples was approximately similar, but the electrical charge used for the deposition process on the heat-treated samples was smaller than that on the as-extruded samples. The current efficiencies of E-paint on AZ samples (AZ61 and AZ61-H) were higher than those of TZ samples (TZ61 and TZ61-H), and on the heat-treated samples were higher than on as-extruded samples. All E-paintings on the four magnesium substrates had an excellent adhesion without any paint detached by tape peel-test. However, many large blisters were formed on the surface of AZ samples, and none, or very small blisters were observed on TZ samples after immersion test in DI-water for 500 h at $40^{\circ}C$. Under salt spray test (SST) conditions, E-paint on AZ samples showed blistering adjacent to scribes, while blistering of E-paint occurred on intact areas of TZ samples. The E-paint on heat-treated samples showed much better corrosion resistance than that on as-extruded samples. The ranking of greater to lesser corrosion resistance of the E-paint on these four different magnesium substrates is indicated by the order: AZ61-H > AZ61 > TZ61-H > TZ61.

  • PDF

The Effect of Activated Ion Calcium for Production of Panax ginseng Seedlings in Paddy Field (논 인삼 우량묘 생산을 위한 활성이온칼슘 처리효과)

  • Kim, Dong-Won;Kim, Jong-Yeob;You, Dong-Hyun;Kim, Chang-Su;Kim, Hee-Jun;Park, Jong-Suk;Kim, Jeong-Man;Lee, Kang-Soo
    • Korean Journal of Medicinal Crop Science
    • /
    • v.20 no.2
    • /
    • pp.124-128
    • /
    • 2012
  • When ginseng seedlings are cultured in paddy fields, quality degradation and yield reduction are induced by severe plant loss with chlorosis on leaves occurred physiological disorder by excessive salt and poor drainage, rusty-root occurrence, and root rot etc. Accordingly, in order to solve these problems, this study was performed to investigate the treatment method, concentrations and time of activated ion calcium as environment-friendly agricultural materials. Activated ion calcium is an enriched and purified water-soluble mineral calcium component for absorbing quickly into plant as a highly functional calcium and it is an alkaline calcium of 37% (370 $m{\ell}$/1 ${\ell}$) concentration with pH 13. Treatment method was that ginseng seeds were sown after removing water in the shade after seed immersion for 1 minute with active ion calcium of 20-fold diluted solution, and then irrigated $4{\ell}$ per 3.3 $m^2$ with 200-fold, 400-fold, and 600-fold diluted solution before emergence on late March, and supplied 1 time on leaves with 500-fold diluted solution in June and July respectively. The disease rate by treatment of activated ion calcium was that on the treatment of soil irrigated with 200-fold diluted solution compared to non-treated soil, damping-off was 33%, anthracnose was 100% reduced and the occurrence rate of rusty-root was 30% reduced. In addition, when active ion calcium of 200-fold diluted solution were soil irrigated, first and second grade ginseng were respectively 26% and 22% produced more, compared with control.

Influence of Temperature on Chloride Ion Diffusion of Concrete (콘크리트의 염화물이온 확산성상에 미치는 온도의 영향)

  • So, Hyoung-Seok;Choi, Seung-Hoon;Seo, Chung-Seok;Seo, Ki-Seog;So, Seung-Young
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.1
    • /
    • pp.71-78
    • /
    • 2014
  • The long term integrity of concrete cask is very important for spent nuclear fuel dry storage system. However, there are serious concerns about early deterioration of concrete cask from creaking and corrosion of reinforcing steel by chloride ion because the cask is usually located in seaside, expecially by combined deterioration such as chloride ion and heat, carbonation. This study is to investigate the relation between temperature and chloride ion diffusion of concrete. Immersion tests using 3.5% NaCl solution that were controlled in four level of temperature, i.e. 20, 40, 65, and $90^{\circ}C$, were conducted for four months. The chloride ion diffusion coefficient of concrete was predicted based on the results of profiles of Cl- ion concentration with the depth direction of concrete specimens using the method of potentiometric titration by $AgNO_3$. Test results indicate that the diffusion coefficient of chloride ion increases remarkably with increasing temperature, and there was a linear relation between the natural logarithm values of the diffusion coefficients and the reciprocal of the temperature from the Arrhenius plots. Activation energy of concrete in this study was about 46.6 (W/C = 40%), 41.7 (W/C = 50%), 30.7 (W/C = 60%) kJ/mol under a temperature of up to $90^{\circ}C$, and concrete with lower water-cement ratio has a tendency towards having higher temperature dependency.