통계 처리 기법을 활용한 염해 오손도 예측 (A Prediction on the Salt Contamination Degree with Statistical Analysis)

  • 최남호;한상옥;박강식;구경완;김종석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1903-1905
    • /
    • 2002
  • The degree of contamination on outdoor insulator is one of the most important factors for the determination of insulation level. And the salt, NaCl, is known as the most dangerous contaminants in the most region of the world. As shown through the preceding study, we could find the close relationship between the generation and deposition of salt contaminants and the meteorological conditions. To analyze the relationship, we monthly measured the ESDD for some sites with brush wiping method, and daily measured the density for one site with the automatic measuring apparatus. And, with the measured data and the meteorological data from KMA(Korea Meteorological Administration), we analyzed the relationship between the two factors with regression method. Through the results of this investigation, we could quantify the comparative contribution of the climatic factors for the pollution level of outdoor insulator, and the results could be used as a useful reference for the maintenance of overhead lines and substations.

  • PDF

LDPE에서 부시형 전기트리의 성장에 수반되는 부분방전 펄스의 특성 (Properties of PD Pulses accompanying with propagation of Bush-type tree in LDPE)

  • 박영국;강성화;정수현;박철현;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1998년도 춘계학술대회 논문집
    • /
    • pp.293-296
    • /
    • 1998
  • Surface electrical conduction in insulator is most important factor to assess the insulation performances of outdoor insulating materials. In this paper, contamination performance of the widely used materials for outdoor insulator - porcelain, EPDM, Silicone rubber - were discussed by measuring properties of average leakage current and scintillation discharge pulses under artificial contamination conditions. The artificial contaminations used were deionized distilled water fog, 0.5wt% NaCl salt fog of light pollution and 2wt% NaCl salt fog of medium pollution. The average leakage current was appeared linearly with applied voltage at dry and clean surface condition. The magnitude of leakage current was almost same at different kinds of samples. In case of deionized distilled water fog, the characteristics of leakage current and applied voltage was most different to that in case of dry and clean condition. In case of salt fog pollution condition, The leakage current was increased above critical voltage. The scintillation discharges were also activated at the level. the leakage current and scintillation discharges were increased with increasing pollution degree. The resistance to pollution properties of silicone rubber appeared excellent among them.

  • PDF

Salt-fog 분무에 따른 실리콘 고무 애자의 표면열화 (Surface Degradation of Silicone Rubber Insulator by Salt-fog Test)

  • 장동욱;박영국;강성화;이용희;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 추계학술대회 논문집
    • /
    • pp.509-512
    • /
    • 1999
  • The main problem in porcelain as a high voltage insulator is that the water film is felled on the insulator surface due to rain, flog, and dew. In the presence of contamination. leakage current increases which may lead to flashover that could be followed by an outage of the power system. These days, high voltage polymer outdoer insulators have been studied and widely used, because they have excellent electrical and mechanical properties, superior performance of flashover for contamination. light weight, easy installation or handling. no maintenance during service, competitive price, and so on. First of a1l the excellent performance of the silicone rubber in polluted and wet conditions is attributed to the ability of the material to maintain the hydrophobicity of the surface in the presence of severe contaminants and wet conditions. This is due to a low surface energy of the silicone rubber. But the leakage current and some surface discharge occurs on the surface of insulator when the insulator is used for a long time. So the leakage current and the surface discharge current are important lo estimate the condition of the silicone rubber surface. In this paper, the average leakage current the surface discharge current the surface rubber surface with the salt fog condition for the first stage.

  • PDF

Salt Repellent Behavior of Superhydrophobic Filtration Membrane

  • 신봉수;김호영;이광렬;문명운
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제43회 하계 정기 학술대회 초록집
    • /
    • pp.236-236
    • /
    • 2012
  • In this study, we present the salt repellent behavior of superhydrophobic filtration membrane. Bio-fouling or mineral-fouling is the main factor of decreasing the performance of filtration membrane. The superhydrophobic modification of filtration membrane using PECVD (Plasma enhanced chemical vapor deposition) is introduced. The oxygen plasma was introduced for developing nano hairy structures and subsequent HMDSO (Hexamethyldisiloxane) coating was used for enhancing low surface energy. Saline water evaporation test was carried out to evaluate the difference of contamination of salt on superhydrophobic and moderately hydrophobic filtration membrane. EDS and EPMA were used for visualizing the residue of salt crystal.

  • PDF

통계적 처리방법을 이용한 동해안 염해 오손물의 분포특성 (The Distribution Characteristics of Salt Contaminants with Statistical Method in East Coast)

  • 최남호;박강식;한상옥
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권3호
    • /
    • pp.130-135
    • /
    • 2001
  • In this paper, the distribution characteristics of salt contaminants with the distance from sea in East coast, from Sokcho to Pusan of Korea peninsula were investigated to evaluate the design standard of KEPCO. To get the equivalent salt deposit density(ESDD), conventional brush wiping method was used. As the measuring period is comparatively short, and the measuring interval is long to check the maximum value, acquired ESDD data is very lower than the recommended value in the standard. The measured data didn't follow normal distribution, so it should take the statistical treatment. Through normalizing method, we could get a reliable probability data. In the past investigation, the accumulation characteristics of Japan is consulted to set the criterion, but the climatic condition of Korea is different to Japan. With the comparison of precipitation data and some measured data for long tern accumulation, we could set appropriate accumulation factor.

  • PDF

기후인자와 ESDD간의 상관관계 분석통한 오손도 예측 (The prediction of contamination degree through the relationship analysis between the climatic factor and ESDD)

  • 이원영;김도영;박흥석;한상옥;박강식
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.1
    • /
    • pp.440-443
    • /
    • 2003
  • Recently, with the rapid growth of industry, environmental condition became worse. With the mix of the various contaminants, such as, salts, dust and industrial pollutants, synergy effect could be happened. So, many researches have been focused on the issue. The cause of natural accident could be classified as, lightning, rainstorm and contamination. However, the accident by contamination influences on the larger area than that by lightning, and, in the case of rapid contamination, it takes a shorter time than rainstorm. The salt contaminant is one of the most representative pollutants, and known as the main source of the accident by contamination. So, in this investigation we make a research on the prediction of contamination degree through the relationship analysis between the climatic factor and ESDD.

  • PDF

옥외용 절연체 표면에서의 ESDD 측정과 내오손특성에 관한 연구 (A Study on Measurement of ESDD and Contamination Performance of Polymeric Outdoor Insulators)

  • 연복희;유형철;이현진;송정용;이태호;허창수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집
    • /
    • pp.427-430
    • /
    • 2002
  • This paper presents on contamination performance of polymeric outdoor insulator with different contaminant accumulation. The ESDD (equivalent salt deposit density), tracking resistance and clean-fog test were performed to investigate the characteristics of contamination performance on polymeric outdoor insulator. Furthermore, we evaluated together with the porcelain samples for its comparison. It is found that ESDD of polymeric and porcelain insulator depends on the installation position. This surface accumulation of contaminant lead to the loss of surface hydrophobicity, expecially upper shed part of polymeric insulator. In addition, the effect of an artificial contaminant on the tracking resistance by inclined-plane method and leakage suppression ability under clean fog was surveyed. The time of tracking failure did not appear to change significantly with a much contaminant accumulation, while leakage current under clean-fog increased.

  • PDF

전국 해안지역의 오손분포도 산정에 관한 연구 (A Study on the Contamination Criterion Map of Seashore Areas in Korea)

  • 김준일;김동명
    • 조명전기설비학회논문지
    • /
    • 제22권10호
    • /
    • pp.89-96
    • /
    • 2008
  • 삼면이 바다로 둘러 싸여 있는 우리나라는 계절풍, 해풍에 의한 염분이 포함된 수분과 중화학공업에 따른 매연, 분진이 배전설비의 표면에 부착되어, 설비의 열화로 인한 정전이 발생할 가능성이 크므로, 염분에 의한 오손등급을 평가하여 설비운영에 활용함으로써, 정전을 예방하고 정전 관련 민원을 최소화할 필요가 있다. 또한, 최근에는 이상 기상 현상으로 인해 과거에 예기치 못한 자연재해가 발생하고 있으므로, 이에 대한 기후조건과 지형자료 등을 바탕으로 새로운 오손분포 산정 알고리즘을 개발하고, 오손분포 도면을 제작하여, 이를 해안지역의 배전설비 설계에 적용하는데 본 연구의 목적이 있다.

죽염의 제조과정에 따른 성분함량의 변화 및 타 염류와의 비교 (Elements in a Bamboo Salt and Comparision of Its Elemental Contents with Those in Other Salts)

  • 김영희;류효익
    • 약학회지
    • /
    • 제47권3호
    • /
    • pp.135-141
    • /
    • 2003
  • The majority of table salts are bay salts and chemical salts. However, chemical salts are known to have a different composition in biological electrolytes and quality of bay salts are getting worse due to the increasing seawater contamination. These facts may have led to the increasing usage of various health-promoting salts. Bamboo salt was introduced in 1986 as a solution to replace table salts to eliminate those detrimental effects, to promote general health and to treat diseases. Although all bamboo salts from different manufacturers have been used for the same health and medical purposes, each manufacturer utilizes different manufacturing process. The ICP analysis was used to study the changes of elemental contents in a bamboo salt during the manufacturing steps as well as these contents in various bamboo salts and other salts. After the first step, contents of Li and Sr in the bamboo salt were increased in comparison with those in the raw material, bay salt. As the next steps continued, contents of K, Ca and Ba were continuously increased. At the completion of the final step, contents of Mg and P were decreased and those of Cu, Mn and Mo were gradually increased. Bamboo salts contained lower contents of Mg, Al, B, and P, but higher contents of K, Ca, Fe, Cu, Mn, Zn, Li, Ba, Sr and Mo than bay salt.