• Title/Summary/Keyword: Safety pressure

Search Result 2,951, Processing Time 0.031 seconds

Trabeculectomy Using Mitomycin C in Aphakic and Pseudophakic Eyes (무수정체안과 인공수정체안에 대한 Mitomycin C를 이용한 일차 섬유주절제술의 효과)

  • Son, Jun-Hyuk;Cha, Soon-Cheol
    • Journal of Yeungnam Medical Science
    • /
    • v.24 no.2
    • /
    • pp.232-242
    • /
    • 2007
  • Background : The safety and efficacy of trabeculectomy with Mitomycin C (MMC) for surgical treatment in aphakic and pseudophaic eyes were retrospectively evaluated. Materials and Methods : The authors reviewed 51 eyes of 45 patients who had been followed up for at least 6 months after trabeculectomy using MMC for aphakic and pseudophakic eyes. The success rate and complications were analyzed. The success criteria included intraocular pressures of 21 mmHg or less with or without glaucoma medications and no loss of light perception. Surgical failure was defined as a postoperative loss of light perception in patients with preoperative vision better than light perception, additional glaucoma surgery, or phthisis bulbi in patients with preoperative vision of no light perception. Results : The average follow up period was 27.7 months and the intraocular pressure was controlled under 21 mmHg in 36 eyes of 51 (70.6%) after the procedure with or without medication for glaucoma. Using the Kaplan-Meier survival analysis, the cumulative success rate at the 3-, 6-, 12-, 24- and 36-month intervals were 98.0%, 94.1%, 91.9%, 83.4% and 75.5%, respectively. The complications observed were hyphema (4 eyes), serous choroidal detachment (4 eyes), hypotony (3 eyes), and endophthalmitis (1 eye). Conclusion : Trabeculectomy using Mitomycin C for the treatment of aphakic and pseudophaic eyes was safe and effective.

  • PDF

Characteristics of Dental Emergency Patients at Busan Paik Hospital (부산백병원 응급실로 내원한 치과 응급환자에 대한 임상적 연구)

  • Kim, So-Hyun;Kim, Do-Young;Baek, Joon-Seok;Jung, Tae-Young;Park, Sang-Jun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.34 no.1
    • /
    • pp.58-64
    • /
    • 2012
  • Purpose: Dental emergencies vary from toothaches to oral and maxillofacial traumas. Because the number of dental emergency cases has increased recently, we analyzed characteristics of patients seen during the last 2 years, in an effort to find a trend. Methods: This study was carried out with emergency room patients visiting the Department of Oral and Maxillofacial Surgery from 2009 to 2010. Results: The total number of patients studied was 1,162; the ratio of males to females was 1.73:1. The most frequent age group was 0 to 9 years, followed by 20 to 29 years. Trauma (58.7%) was the most frequent cause followed by acute toothache, oral hemorrhage, infection, and temporomandibular (TMJ) disorder. In the trauma group, injuries of soft tissue and alveolus were prevalent. The most common causes of soft tissue injury were falls, safety violations and assault. The highest incidence of emergencies was seen in patients 0 to 9 years old (41.8%). The most common causes of jaw fracture were falls, assaults, and traffic accidents in that order. In the acute toothache group, most patients had pulpitis (41.2%). In the infection group, most had buccal space abscesses (40.0%). In the hemorrhage group, post-operative bleeding cases (80.5%) were the majority, and hemostasis was obtained mostly by pressure dressings. For the TMJ disorder group, masticatory muscle disorder (65.4%) was more common than TMJ dislocation. Conclusion: In this study, trauma was the most frequent reason for patients who visited the emergency room. However, acute toothache, hemorrhage, infection and TMJ disorders were also seen frequently. Dental emergency patients could be better treated by understanding patterns of dental emergencies and performing proper diagnoses.

Analysis of Air Discharge and Disused Air Filters in Radioisotope Production Facility

  • Kim, Sung Ho;Lee, Bu Hyung;Kwon, Soo Il;Kim, Jae Seok;Kim, Gi-sub;Park, Min Seok;Jung, Haijo
    • Progress in Medical Physics
    • /
    • v.27 no.3
    • /
    • pp.156-161
    • /
    • 2016
  • When air discharged from a radioisotope production facility is contaminated with radiation, the public may be exposed to radiation. The objective of this study is to manage such radiation exposure. We measured the airborne radioactivity concentration at a 30 MeV cyclotron radioisotope production facility to assess whether the exhaust gas was contaminated. Additionally, we investigted the radioactive contamination of the air filter for efficient air purification and radiation safety control. To measure the airborne radiation concentration, specimens were collected weekly for 4 h after the beginning of the radioisotope production. Regarding the air purifier, five specimens were collected at different positions of each filter-pre-filter, high-efficiency particulate air filter, and charcoal filter-installed in the cyclotron production room. The concentrations of F-18, I-123, I-131, and Tl-201 generated in the radioiodine production room were $13.5Bq/m^3$, $27.0Bq/m^3$, $0.10Bq/m^3$, and $11.5Bq/m^3$, respectively; the concentrations of F-18, I-123, and I-131 produced in the radioisotope production room were $0.05Bq/m^3$, $16.1Bq/m^3$, and $0.45Bq/m^3$, correspondingly; and those of F-18, I-123, I-131, and Tl-201 generated in the accelerator room were $2.07Bq/m^3$, $53.0Bq/m^3$, $0.37Bq/m^3$, and $0.15Bq/m^3$, respectively. The maximum radiation concentration of I-123 generated in the radioiodine production room was 1,820 Bq/g, which can be disposed after 2 days. The maximum radiation concentration of Tl-202 generated in the radioisotope production room was 205 Bq/g, and this isotope must be stored for 53 days. The I-123 generated in the radioiodine production room had a maximum concentration of 1,530 Bq/g and must be stored for 2 days. The maximum radiation concentration of Na-22 generated in the radioisotope production room was 0.18 Bq/g and this isotope must be disposed after 827 days. To manage the exhaust, the efficiency of air purification must be enhanced by selecting an air purifier with a long life and determining the appropriate replacement time by examining the differential pressure through systematic measurements of the airborne radiation contamination level.

Test methodology of acceleration life test on feeder cable assembly (Feeder Cable Assembly의 가속수명시험법 개발)

  • Han, Hyun Kak
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.8
    • /
    • pp.62-68
    • /
    • 2016
  • The feeder cable assembly is an automotive part used for telecommunication. If it malfunctions, the control and safety of the automobile can be put at risk. ALT (Accelerated Life Testing) is a testing process for products in which they are subjected to conditions (stress, strain, temperatures, etc.) in excess of their normal service parameters in an attempt to uncover faults and potential modes of failure in a short amount of time. Failure is caused by defects in the design, process, quality, or application of the part, and these defects are the underlying causes of failure or which initiate a process leading to failure. Thermal shock occurs when a thermal gradient causes different parts of an object to expand by different amounts. Thermal shock testing is performed to determine the ability of parts and components to withstand sudden changes in temperature. In this research, the main causes of failure of the feeder cable assembly were snapping, shorting and electro-pressure resistance failure. Using the Coffin-Manson model for ALT, the normal conditions were from Tmax = $80^{\circ}C$ to Tmin = $-40^{\circ}C$, the accelerated testing conditions were from Tmax = $120^{\circ}C$ to Tmin = $-60^{\circ}C$, the AF (Acceleration Factor) was 2.25 and the testing time was reduced from 1,000 cycles to 444 cycles. Using the Bxlife test, the number of samples was 5, the required life was B0.04%.10years, in the acceleration condition, 747 cycles were obtained. After the thermal shock test under different conditions, the feeder cable assembly was examined by a network analyzer and compared with the Weibull distribution modulus parameter. The results obtained showed good results in acceleration life test mode. For the same reliability rate, the testing time was decreased by a quarter using ALT.

Measurement of the Size Distribution of Smoke Particles with Plastic Types Under Various Fire Conditions (다양한 화재조건에서 플라스틱 종류에 따른 연기입자의 크기분포 변화 측정)

  • Goo, Jaehark;Hwang, Cheol-Hong
    • Fire Science and Engineering
    • /
    • v.31 no.6
    • /
    • pp.8-15
    • /
    • 2017
  • Most fire victims succumb to smoke inhalation, and fire smoke toxicity from interior materials is increasing with increased use of plastics. Large amounts of hazardous effects of smoke are related to deposition of smoke particles in respiratory tracts, and deposition characteristics are influenced by size distribution of particles. Thus, it is essential to know the size distribution of smoke particles from plastics for hazard analysis of fire smoke. In a recent study, it has been shown that size distributions of smoke particles from PP are different from wood in many aspects. In order to know whether other plastics show the same characteristics as PP, size distributions of smoke particles from four plastic materials (LDPE, PA66, PMMA, and PVC) were measured in real time under each fire type with various temperature and oxygen supply. In this study, smoke particles from different plastics were generated uniformly by using steady-state tube furnace method provided in ISO/TS 19700. Their size distributions were measured by using an electrical low pressure impactor (ELPI). Results of measurements showed that size distributions of smoke particles from these four plastic materials were similar to those from PP in many aspects. However, they were distinctively different from those of wood.

The Effect of Psychological Factors of Speeding Behavior Using a Driving Simulator (Focused on Speeding Intention) (차량시뮬레이터를 이용한 과속운전의 심리적 요인 연구 (과속의도를 중심으로))

  • Ryu, Jun-Beom;Sin, Yong-Gyun;Park, Je-Jin
    • Journal of Korean Society of Transportation
    • /
    • v.29 no.1
    • /
    • pp.39-46
    • /
    • 2011
  • Speeding is a major cause of traffic accidents that affects the safety of pedestrians and harms drivers and their families, property and mental health. However, most researches on speeding behavior have been conducted by survey method, so the relationship between cause and effect is not clear. The reliability of the research cannot be carefully examined because most researches involve retrospective methods. It is clear that conducting experimental research is important for overcoming these limitations, but it is impossible to perform tests with real cars in real traffic situations due to the inability to control situational factors (e.g., other vehicles, traffic signal) which affect participants' behavior. A car simulator experiment was designed and the theory of planned behavior was applied to the experiment. Each participant was grouped and assigned to either high speeding intention group or low speeding intention group according to their levels of speeding intention and analyzed the difference of driving behavior indexes between two groups. The results revealed statistically significant differences between two groups on driving speed, speeding frequency, and accelerator pressure deviation. Finally, the limitations and the implications of this study were discussed.

Assessment of Cerebral Collateral Circulation Using $^{99m}Tc$-Hexamethyleneamine Oxime (HMPAO) SPECT During Internal Carotid Artery Balloon Test Occlusion (내경동맥 풍선 시험 결찰술(BTO)시 $^{99m}Tc$-HMPAO 뇌 SPECT를 이용한 대뇌 측부 순환의 평가)

  • Ryu, Young-Hoon;Yun, Mi-Jin;Chung, Tae-Sub;Lee, Jong-Doo;Park, Chang-Yun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.1
    • /
    • pp.22-30
    • /
    • 1995
  • To predict preoperatively the safety of permanent occlusion of an internal carotid artery with $^{99m}Tc$-HMPAO brain single photon emission computed tomography(SPECT) from an objective point of view, Twenty-four patients underwent balloon test occlusion (BTO) of the internal carotid arteries because of neck and skull base tumors. The authors assessed the uptake of both middle cerebral artery territories before and during BTO with $^{99m}Tc$-HMPAO brain SPECT using semiquantitative analysis method and compared the results with other factors(neurologic examination, arterial stump pressure and electroenceph-alogram). Nineteen patients had not experienced neurological deteriorating or any problem during BTO. Their comparative uptakes of the middle cerebral artery territories were 95 to 101% of the pre-BTO state. The remaining five patients showed severe neurologic symptoms such as transient hemiplegia and unconsciousness. Their comparative uptake of the middle cerebral artery territories were 77 to 85% of the pre-BTO state, and were well matched with other factors. $^{99m}Tc$-HMPAO brain SPECT before and during BTO seems to be a simple and objective method for prediction of permanent neurologic deficits when the comparative uptake of middle cerebral artery territories during BTO is lower than 85% of that before BTO.

  • PDF

Performance Evaluation of Balance Ability Equipment Using VR (VR을 이용한 균형능력 측정장비의 성능평가)

  • Yoon, Sangcheol;An, Howon;Ahn, Taekwon;Choi, Haesung;Lee, Byoungkwon;Seo, Dongkwon;Lee, Kyuhwan;Jung, Sangwoo;Yi, Jaehoon
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.8 no.3
    • /
    • pp.33-41
    • /
    • 2020
  • Purpose : Conventional Balance Measurement can only measure the center of gravity and the shaking movement of the body. As a result, it has the disadvantages of not responding to visual changes and blocking functions of variables. This study was carried out to evaluate the performance of new equipment that measures the balance of the body using changes in body segment and pressure using the acceleration sensor to compensate for the disadvantages of the existing equipment. Methods : To this end, balance ability was measured in 43 healthy male/female adults without orthopedic injuries and nervous system damage in the last 6 months. in a situation where the visual information was restricted by Virtual Reality (VR) gear, all subjects measured and evaluated the balance ability utilizing the new equipment. Balance measurement (Prime Medilab, Korea) and Wii fit (Nintendo, Japan) were used to measure the balance ability of the subjects, and the balance ability test was performed in 4 postures using each device for data acquisition. The test duration for each posture was 30 seconds. For data acquisition, the average value of three experiments measured using each equipment was analyzed, and the statistical test was performed using the independent sample and the corresponding sample t-test, and the significance level was set to α=.05. Results : As a result of measuring the balance ability using individual equipment, blocking visual information using VR gear, the average speed, maximum speed, and moving area of the COP increased equally. It was found that the obtained absolute size of the result in Wii was somewhat larger than that of BM. Conclusion : It is considered that in the future research, it is necessary to measure changes in the body's center of gravity through image analysis, etc., to make clear comparison and evaluation of the usability.

Landslide Analysis of River Bank Affected by Water Level Fluctuation I (저수위 변동에 영향을 받는 강기슭의 산사태 해석 I)

  • Kim, You-Seong;Wang, Yu-Mei
    • Journal of the Korean Geosynthetics Society
    • /
    • v.9 no.3
    • /
    • pp.77-85
    • /
    • 2010
  • The change of water level in reservoirs is an important factor causing failure of bank slopes, i.e. landslide. The water level of Three Gorges reservoir in China fluctuate between 145 m and 175 m, as a matter of flood control. During its normal operational state, the rate of water level fluctuation is supposed to range from 0.67 m/d to 3.0 m/d. Majiagou slope is located on the left bank of Zhaxi River, 2.1 km up from the outlet. Zhaxi River is a tributary of the Yangtze River within the Three Gorges area, of which the water level changes with the reservoir. At the back of Majiagou slope, a 20 m long and 3~10 cm wide fissure developed just after the reservoir water level rose from 95 m to 135 m in 2003. This big fissure was a full suggestion of potential failure of this slope. In this study, unsaturated-saturated seepage analyses were carried out to simulate the change of pore-water pressures in the bank slope subjected to the reservoir water level change. The obtained pore-water pressures were then used to evaluate the change in factor of safety (FS) with reservoir water level. It was found that the phreatic line showed a delayed response with respect to the change of the reservoir water level, because the seepage through soil layer was generally slower than water flows itself. During the rising and drawdown process, the phreatic lines take the shapes of concave and convex, respectively. And the fluctuation of reservoir water level just affected the front part of the bank slope, but had little influence on the back of the slope.

  • PDF

Efficacy and Adverse Events of Bangpungtongseong-san(Bofutsusho-san) and Bangkihwangki-tang(Boiogiot-tang) by Oriental Obesity Pattern Identification on Obese Subjects : Randomized, Double Blind, Placebo-controlled Trial (비만 환자에서 한방 비만 변증에 따른 방풍통성산과 방기황기탕의 치료효과 및 부작용 비교 : 무작위 배정, 이중 맹검, 위약-대조군 임상시험)

  • Park, Jung-Hyun;Lee, Myeong-Jong;Kim, Ho-Jun;Hong, Sun-woo;Lee, Dong-Ki;Yoo, Jae-Wook;Choi, Sun-Mi;Moon, Jin-Seok;Lim, Chi-Yeon;Lee, Jung-bok
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.21 no.2
    • /
    • pp.265-278
    • /
    • 2011
  • Objectives : This trial were conducted to evaluate the efficacy and adverse events of Bofutsusho-san(BTS) and Boiogiot-tang(BOT) by oriental obesity pattern identification on obese subjects, as compared to placebo. Methods : 166 subjects(body mass index ${\geq}25kg/m^2$) were recruited and randomized to receive BT(n=55), FH(n=55) or placebo(n=56) for 8 weeks. Anthropometric factors, serum lipid, glucose, blood pressure(BP), pulse rate, resting metabolic rate and oriental obesity pattern identification questionnaire were measured at baseline and 8 weeks. Adverse events and safety outcome variables were also checked during trials. Results : The frequency of top-scored oriental obesity pattern was ordered by indigestion(食積) > stagnation of the liver qi(肝鬱) > yang deficiency(陽虛) > spleen deficiency(脾虛) > phlegm(痰飮) > blood stasis(瘀血) in subjects. BTS group significantly decreased body weight, body mass index(BMI), waist circumference(WC), body fat mass, total cholesterol and HDL-cholesterol in stagnation of the liver qi(肝鬱) and WC in indigestion(食積). BOT group showed significant decrease of body weight, BMI, WC, and body fat mass in indigestion(食積) not in deficiency(虛症). Adverse events were reported most frequently in yang deficiency(陽虛) by BT group and stagnation of the liver qi(肝鬱) by BOT group. Conclusions : Bofu-tsusho-san was effective in treating obesity with stagnation of the liver qi(肝鬱). Obesity pattern identification could be a useful diagnostic tool predicting treatment effects and adverse events.