• 제목/요약/키워드: Safety operation standards

검색결과 353건 처리시간 0.032초

가정용연료전지 전기적 안전성 평가 기법 개발 (Development of Electrical Safety Evaluation Method about PEMFC 1kW)

  • 한운기;박찬엄;정진수;고원식
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.99-99
    • /
    • 2011
  • Fuel cell systems are a completely different form of electricity source that has been used so far and is an aggregation of multiple technologies with multidisciplinary features that can be operated safely only when gas and electrical safety are being considered. Since fuel cells generate through electrochemical reactions there are difficulties in ensuring electricity safety, power quality assessment, effective control and reliability standards for system faults using conventional inspection techniques and even though they are necessary as a primary means for reduction of CO2 owing to the Climate Convention, electrical safety assessment and measures are required for the prevention of faults in residential facilities. Although small-scaled distributed power supplies can be utilized as important means of peak control and energy management measures, research is required for observing the effects on the system and the development of inspection technology to ensure stable operation, and the electrical safety of residential fuel cell systems need to be assessed and the problems derived for establishing electrical safety standards. From the year 2002, Japan has established laws on technical safety standards and development and rules on the product specifications and standards for the industrialization of hydrogen fuel cells. Also, a lot of effort have been made for the commercialization of fuel cells by building one-stop certification services. Internationally, the IEC TC 105 has established international standards based on fuel cells. In order to protect the national interest, the country should be able to respond accordingly meet global standards. In fact, in Korea, to comply with the international trend, Korea Energy Management Corporation is establishing a certified agenda for fuel cells and Korean Agency for Technology and Standards is enacting technical standards for fuel cells. The current terms of fuel cells are that research has been focused more on the quality and performance of manufactured products rather than stable power operation and maintenance over time. In this paper, by considering the household fuel cell as a power device, the safety standards of the fuel cell system for a reliable operation with the existing power system is being proposed.

  • PDF

국내 제조업 화재감시자 운영의 문제 확인 및 개선방안 (Identification of Problems and Improvement Measures of Fire Observer Operation in Domestic Manufacturing Industry)

  • 김경민;서용윤;이종빈;장성록
    • 한국안전학회지
    • /
    • 제38권6호
    • /
    • pp.26-35
    • /
    • 2023
  • Sparks cause most fire and explosion accidents in the manufacturing industry during hot work, which ignites surrounding combustible materials. Such incidents lead to high casualties due to suffocation from toxic gases and lack of evacuation. Therefore, the government recently enacted and revised 'The Occupational Safety and Health Act' to prevent fires and explosions at work sites, incorporating legal standards for fire observers, which are important in preventing accidents and the spread of fire during hot work. However, there are notable shortcomings in conducting professional cause analysis of these accidents and in aligning them with advanced foreign legal standards. Additionally, there is a lack of literature review reflecting the manufacturing industry characteristics. Despite the recent enactment and revision of legal standards, gathering sufficient opinions and professional reviews remains insufficient. To address these gaps, interviews were conducted with safety and health workers, analyzing recent fire and explosion causes in domestic manufacturing industries, and reviewing both domestic and international legal standards. Conclusively, proposed improvement measures were centered on the professionalization of fire observer education, enhancing their roles and authority realistically, and improving fire observer placement and operation standards. Consequently, additional 'Occupational Safety and Health Act' standards are necessary for fire observer education and defining the government's role. Second, precise legal standards outlining the role and authority of fire observers are required. Third tailored fire observer arrangements and management standards appropriate for varying work characteristics and company sizes are required. This study emphasizes the importance of supplementing relevant legal standards to prevent fire accidents in the manufacturing industry.

시민안전보험 운영관리체계의 개선방안 연구 (A Legal Study on Improvement Plans for Citizen Safety Insurance Operation and Management System)

  • 이정임
    • 대한안전경영과학회지
    • /
    • 제24권2호
    • /
    • pp.77-85
    • /
    • 2022
  • This study tried to suggest a systematic improvement plan to prepare a civil safety insurance operation and management system by reviewing the operation and management status of civil safety insurance, which is operated and managed by each local government autonomously. In this study, the problems of the current civil safety insurance were analyzed by dividing them into the lack of systematic management of insurance items, overlapping coverage between insurance items, and deviations in compensation limits. As a systematic improvement plan, it was suggested to secure the systemic management of guarantee items, standardize compensation standards, prepare an integrated operation and management system, and provide financial support for local governments with poor financial independence. Since the problems and improvement plans for the civil safety insurance analyzed as described above are formed by exchanging and receiving a complex mutual influence, the institutional improvement plan for the operation and management system of the civil safety insurance is not only a specific part of the study, but also comprehensively current citizens. Based on the results derived from the analysis of safety insurance, it is concluded that alternatives must be found.

공연종사자 피난을 위한 안전시설의 운영전략 연구 (A Study of the Safety Facilities Operation Strategies for Performing Arts Workers Evacuation)

  • 정성학;박용규
    • 대한안전경영과학회지
    • /
    • 제26권1호
    • /
    • pp.63-74
    • /
    • 2024
  • The objectives of this study is to classify evacuation types, derive the characteristics of 4 types, develop and discover evacuation routes within the performance hall space, and present the statistical classification results of the evacuation classification model by classification type. To achieve this purpose, the characteristics of each evacuation type's four types are applied through a network reliability analysis method and utilized for institutional improvement and policy. This study applies for the building law, evacuation and relief safety standards when establishing a performance hall safety management plan, and reflects it in safety-related laws, safety standards, and policy systems. Statistical data by evacuation type were analyzed, and measurement characteristics were compared and analyzed by evacuation types. Evaluate the morphological similarity and reliability of evacuation types according to door width and passage length and propose the install position of evacuation guidance sign boards. The results of this study are expected to be used as basic data to provide operation strategies for safety facility evacuation information sign boards according to evacuation route classification types when taking a safety management plan. The operation strategy for the evacuation sign boards installation that integrates employee guidance and safety training is applied to the performance hall safety management plan. It will contribute to establishing an operational strategy for performance space safety when constructing performance facilities in the future.

수소연료전지자동차에 대한 안전기준 고찰 (Study of KMVSS for Hydrogen Fuel Cell Vehicle)

  • 용기중;이광범;권해붕
    • 자동차안전학회지
    • /
    • 제6권2호
    • /
    • pp.72-77
    • /
    • 2014
  • In the ongoing debates over the need to identify new sources of energy and to reduce the emissions of greenhouse gases. Hydrogen has emerged as one of the most promising alternatives due to its emissions from the vehicle being virtually zero. The governments have identified the development of regulations and standards as one of the key requirements for commercialization of hydrogen-fueled vehicles. Regulations and standards will helpful in overcoming technological barriers to commercialization. Developments of a technique for safety assessment of Hydrogen Fuel Cell Vehicle(HFCV) includes four tasks, research for regulation system and policy, hydrogen safety, vehicle operation safety and protection against high-voltage. The objective is to establish a technique for safety assessment and amend safety standards for HFCV and consequently reflect research results to vehicle management policy. We devised safety standards and evaluation techniques with regard to high-pressure gas and high voltage of hydrogen fuel cell vehicle. Korean Motor Vehicle Safety Standards(KMVSS) for HFCV was amended to June 10, 2014. including the results of the safety assessment technology for high-voltage and hydrogen characteristics.

선박직원법상 소형선박조종사의 승무기준 개선에 관한 연구 (A Study on the Improvement of Manning Standards of Small Vessel Operator in the Ship Officer's Act)

  • 김동근;전영우
    • 해양환경안전학회지
    • /
    • 제12권4호
    • /
    • pp.307-312
    • /
    • 2006
  • 최근 들어 선박직원법상 승무기준의 개정의 필요성에 대한 강력한 주장이 수산업계에서 제기되었다. 수산업계에서는 승무기준완화 입장을 유지하는 반면 노동계와 해기사협회 및 통신사협회는 현행유지 내지 기준의 강화를 주장하였다. 본 연구는 선박안전운항을 확보하기 위하여 선박직원법상 소형선박조종사 승무기준의 타당성과 그 개선 방안을 연구 제시하고자 한다.

  • PDF

산업현장의 천장크레인 조작장치 사용 현황과 인간공학적 문제점 (Overhead Crane Controllers and Ergonomic Problems in Industrial Field)

  • 박재희;김승희
    • 한국안전학회지
    • /
    • 제32권1호
    • /
    • pp.90-97
    • /
    • 2017
  • Overhead cranes are the most widely used and have been identified as one of the main causes of fatal accidents. Although structural, mechanical and electrical safety standards for overhead cranes have been established to some extent, ergonomic standards related to crane controllers are rarely established. As a result, many crane accidents are reported to be caused by operator's error. To investigate the actual use of crane controllers in the industrial field, we surveyed 82 overhead cranes in 15 workplace and interviewed workers operating them. This study has presented the ergonomic problems related to the crane controllers in the field. As a result of investigation, it was found that the direction control signs, the sign language, and the button layout on the pendant switches and remote controllers are not standardized, which can cause a human error. To reduce human errors in overhead crane operation, ergonomic standards for controllers should be reflected on the government legislation or standards.

안전요원 배치 여부에 따른 무인운전 경전철의 운행중단 시간예측 연구 (A Study on Prediction of Suspension Time of Unmanned Light Rail according to Safety Personal Deployment)

  • 곽상록
    • 한국안전학회지
    • /
    • 제38권1호
    • /
    • pp.87-92
    • /
    • 2023
  • The number of unmanned light rail train operators is continuously increasing in Korea. In a failure event during an operation due to the nature of the unmanned operation, recovery is performed based on the remote control. However, if remote recovery is not feasible, safety personnel arrive at the train to resume the train operation. There are regulations on safety personnel and the suspension time of the train operation. However, there is currently no rule for safety personnel deployment. Currently, railway operating organizations operate in three scenarios: safety personnel on board trains, stationed at stations, and deployed at major stations. Four major factors influence the downtime for each emergency response scenario. However, these four influencing factors vary too much to predict results with simple calculations. In this study, four influencing factors were considered as random variables with high uncertainty. In addition, the Monte Carlo method was applied to each scenario for the safety personnel deployment to predict train service downtime. This study found a 17% difference in train service suspension by safety personnel deployment scenario. The results of this study can be used in setting service goals, such as standards for future safety personnel placement and frequency of service interruptions.

수소연료전지 자동차 안전성 평가기술 개발 (Development of Safety Assessment for Hydrogen Fuel Cell Vehicle)

  • 용기중;이광범
    • 한국수소및신에너지학회논문집
    • /
    • 제25권5호
    • /
    • pp.500-508
    • /
    • 2014
  • In the ongoing debates over the need to identify new sources of energy and to reduce the emissions of greenhouse gases. Hydrogen has emerged as one of the most promising alternatives due to its emissions from the vehicle being virtually zero. The governments have identified the development of regulations and standards as one of the key requirements for commercialization of HFCV. Regulations and standards will help overcome technological barriers to commercialization. The development of Global Technical Regulation (GTR) for HFCV occurred under the World Forum for Harmonization of Vehicle Regulations. Development of a technique for safety assessment of HFCV include four tasks, research for regulation system and policy, hydrogen safety, vehicle operation safety and protection against high-voltage. The objective is to establish a technique for safety assessment and amend safety standards for HFCV and consequently reflect research results to vehicle management policy. We devised safety standards and evaluation techniques with regard to high-pressure gas and high voltage of hydrogen fuel cell vehicle. KMVSS for HFCV was amended to June 10, 2014. including the results of the safety assessment technology for high-voltage and hydrogen characteristics.

The application study of preventive maintenance during normal operation for APR1400 nuclear power plants considering risk

  • Jung-Wun Kim;YoungJu Lee;Weon Gyu Shin
    • Nuclear Engineering and Technology
    • /
    • 제56권10호
    • /
    • pp.4327-4334
    • /
    • 2024
  • Preventive Maintenance(PM) for safety component during power operation at nuclear power plants, On-Line Maintenance(OLM) refers to intentionally entering the Limited Condition of Operation(LCO) specified in the Technical Specification(TS) for safety-related systems and components in order to perform preventive maintenance within the Allowed Outage Time (AOT). This study assessed the feasibility of conducting OLM at the domestic APR1400 nuclear power plant. It focused on preventive maintenance duration and risk perspectives. A total of 78 FEGs were developed for 4450 facilities, considering system functions and preventive maintenance scope during output operation for eight safety-related systems. Additionally, maintenance items included in FEGs were selected, designated as targets for OLM, and their maintenance durations were evaluated and compared with AOT for each maintenance item. As a result, the Auxiliary Feedwater and Essential Chilled Water systems were identified as systems allowing OLM. Furthermore, utilizing the Risk Monitoring System (RIMS), the increased risk value due to the unavailability of target equipment during preventive maintenance was analyzed to determine whether it falls within the acceptable range. Regarding the temporary risk increase caused by OLM, it was observed that in all systems, it falls within Zone III according to NUMARC93-01 standards, allowing for normal equipment arrangement for OLM. However, according to the risk increase standards rate in domestic nuclear power plants, when maintaining the A-train in four systems including Component Cooling Water, they are all evaluated as 'Orange,' indicating that measures for risk mitigation are necessary for OLM to be feasible. When considering extending AOT up to 1.6 times the maintenance time, the risk increase falls within Zone III according to permissible change in risk standards, indicating that AOT extension might be feasible based solely on risk changes. To apply OLM within the permissible risk management scope in domestic nuclear power plants, regulatory policies need to allow voluntary LCO entry for preventive maintenance, necessitating clear determination by regulatory agencies using risk-informed policies. While OLM seems viable concerning maintenance duration and quantitative risk aspects, for inducing regulatory policy changes, comprehensive OLM guidelines are necessary, including risk management strategies.