• Title/Summary/Keyword: Safety measure

Search Result 1,839, Processing Time 0.031 seconds

A Performance Evaluation of Diagnostic X-ray Unit Depends on the Hospitals Size (병원 규모별 진단용 X선 발생장치의 성능 평가)

  • Park, Ju-Hun;Im, In-Chul;Dong, Kyung-Rae;Kang, Se-Sik
    • Journal of Radiation Protection and Research
    • /
    • v.34 no.1
    • /
    • pp.31-36
    • /
    • 2009
  • The purpose of this study is to measure the tube voltage, the tube current/volume, exposure time and exposure dose of diagnostic X-ray unit in each doctor offices, hospitals and general hospitals for evaluating the performance of such device, to learn the method and technology of its measurement and to suggest its importance. Research subjects were total 30 X-ray units and divided into groups of 10 X-ray units each. The tube voltage, the tube current/volume, exposure time and exposure dose were measured using percentage average error, and then reproducibility of exposure dose was measured through calculating coefficient of variation. The results are like followings; The tube voltage correctness examination showed that incongruent devices among total 30 X-ray units were 5 devices (16.7%). The tube current correctness examination showed that incongruent X-ray units were 3 devices (10.0%). The tube current volume correctness examination showed that incongruent X-ray units were 4 devices (13.3%). Finally, according to exposure time correctness examination, incongruent X-ray units were 5 devices (16.7%) and according to reproducibility examination of exposure dose, incongruent X-ray units were 7 devices (23.3%). Above results showed serious problem in performance management based on management regulation of diagnostic X-ray unit; it means that regular checkout and safety management are required, and as doing so, patients will be able to receive good quality of medical service by the reduction of radiation exposure time, image quality administration, unnecessary retake and etc. Therefore, this study suggests that the performance of diagnostic X-ray units should be checked regularly.

A Comparative Study on the Commitment of Health Manager Between Industrial Health Nurse and Industrial Hygienist (보건관리자의 직능별 직업 및 조직 헌신도에 대한 비교 연구)

  • Rhee, Kyung Yong;Lee, Ki Beom;Allen, Natalie J.;Cho, Young Sook
    • Korean Journal of Occupational Health Nursing
    • /
    • v.7 no.1
    • /
    • pp.65-82
    • /
    • 1998
  • This study was carried out in order to confirm the reliability and validity of the commitment inventory developed by Meyer and Allen, and to investigate commitment level of health manager, to compare two different professionals of health manager such as industrial health nurse and industrial hygienist to find out some characteristics that have effect on commitment. This survey was done by self-administered questionnaire to 227 respondents as the trainees of Industrial Safety Training Center, KISCO from June to December 1996. Authors classified commitment into two categories ; professional commitment and organizational commitment, and these two types of commitments have three different aspects ; affective, continuance, and normative commitment based on Meyer's inventory. The results were as follows; 1. Items of whole scales of the both type of commitments have three factors that represent three aspects of commitment ; affective, continuance, and normative commitment. This means that each type of commitment was reliable to use as measurement tool of three different aspects of commitment. Classification of items by factor analysis was more consistent in professional commitment than organizational commitment. Among 16 items of organizational commitment, four items were classified into different aspects of commitment with similar factor loading. 2. Commitment level of industrial health nurse was higher than that of industrial hygienist in affective, continuance professional commitment controlled by other characteristics. These differences can be due to other characteristics of specific task and background of health managers that were not used in this study. 3. The level of affective professional commitment was statistically different in age, sex, educational level, and that of organizational commitment was statistically different in only two variables such as age, and job tenure. The level of continuance professional and organizational commitments were different in sex group, but past history of employment have effect on continuance organizational commitment. The level of normative organizational commitment was affected by only age. As the above results, the tools of measurement of commitment developed by Meyer and Allen can be useful to measure the level of commitment of health manager. Three aspects of two types of commitments were influenced by different characteristics of health manager. Authors suggested future study on the affecting variables to the commitment such as background, task of health manager and organizational characteristics.

  • PDF

Effect of Postharvest Treatments on Storage Quality of Buckwheat Sprouts (메밀 새싹채소의 저장품질에 대한 수확 후 처리공정 효과)

  • Lee, Hyun-Hee;Hong, Seok-In;Kim, Dong-Man
    • Korean Journal of Food Science and Technology
    • /
    • v.43 no.1
    • /
    • pp.98-104
    • /
    • 2011
  • The storage quality of fresh buckwheat sprouts, as influenced by pretreatment and packaging within processing steps, was investigated to establish appropriate postharvest handling treatment for the commodity. After harvest, the sprouts were dipped in chlorine water (100 ppm), rinsed twice with clean water, pre-cooled with iced water, de-watered, and packed in plastic trays. Sprout samples taken from each processing step were stored at $5^{\circ}C$ for 6 days to measure quality attributes. Viable cell counts of mesophilic aerobes and coliform bacteria were lower by about 1 log scale in the postharvest treated samples compared to an untreated control, although the initial microbial reduction due to the postharvest treatments was offset by cell growth during storage. All sprout samples showed a decrease of fresh weight by approximately 4% after 6 days of storage. However, moisture and soluble solid contents were maintained at the initial levels of the sprouts. No significant difference in surface color was observed among sample treatments. For sensory properties including discoloration, wilting, decay, and visual quality, there were no significant differences among sample treatments. The present results suggest that proper postharvest processing treatments can exert positive effects on extending the shelf-life of fresh buckwheat sprout.

3D Measurement Method Based on Point Cloud and Solid Model for Urban SingleTrees (Point cloud와 solid model을 기반으로 한 단일수목 입체적 정량화기법 연구)

  • Park, Haekyung
    • Korean Journal of Remote Sensing
    • /
    • v.33 no.6_2
    • /
    • pp.1139-1149
    • /
    • 2017
  • Measuring tree's volume is very important input data of various environmental analysis modeling However, It's difficult to use economical and equipment to measure a fragmented small green space in the city. In addition, Trees are sensitive to seasons, so we need new and easier equipment and quantification methods for measuring trees than lidar for high frequency monitoring. In particular, the tree's size in a city affect management costs, ecosystem services, safety, and so need to be managed and informed on the individual tree-based. In this study, we aim to acquire image data with UAV(Unmanned Aerial Vehicle), which can be operated at low cost and frequently, and quickly and easily quantify a single tree using SfM-MVS(Structure from Motion-Multi View Stereo), and we evaluate the impact of reducing number of images on the point density of point clouds generated from SfM-MVS and the quantification of single trees. Also, We used the Watertight model to estimate the volume of a single tree and to shape it into a 3D structure and compare it with the quantification results of 3 different type of 3D models. The results of the analysis show that UAV, SfM-MVS and solid model can quantify and shape a single tree with low cost and high time resolution easily. This study is only for a single tree, Therefore, in order to apply it to a larger scale, it is necessary to follow up research to develop it, such as convergence with various spatial information data, improvement of quantification technique and flight plan for enlarging green space.

A Study on the Analysis of Market Efficiency of Agricultural Products in E-Commerce B2C Platform -Based on the Consumers' Price Fairness Perceptions- (전자상거래 B2C 플랫폼 농산물 시장효율성 분석에 관한 연구 -소비자의 가격공정성 관점 기준으로-)

  • Bai, Xiu-Na;Chung, Gi-Young;Kim, Hyung-Ho
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.6
    • /
    • pp.237-248
    • /
    • 2020
  • The purpose of this study is to measure the agricultural product market efficiency of the three e-commerce platforms from the perspective of consumer price fairness perception, analyze the quality and price gap of invalid brands, and help agricultural products enterprises to formulate reasonable price strategies. The characteristics of farm products sold in e-commerce platforms(quality, origin, taste, safety level) were selected as output indicators and the prices of products were selected as input indicators to evaluate the efficiency of the market through DEA analysis. According to the analysis, JD mall has the largest proportion of effective brands, while YHD.com has the highest average market efficiency, and northeast rice has the largest difference in average efficiency among the three platforms. The results show that price inefficiencies still exist in the electronic market. The development of online market for agricultural products should pay attention to consumer price fairness and pay attention to the coordination between price and quality. The limitation of this paper is that it does not focus on the influence of words of mouth marketing in internet market and consumer experience, which can be the future research direction.

Analysis on the Safety of Structure and Economics of Replacement Method Using Rock Debris in the Soft Ground - Case Study of Miho Stream Crossing Road in Cheongju City (연약지반 암버럭 치환공법의 구조물 안정성과 경제성 분석 - 청주시 미호천 횡단도로를 대상으로)

  • Heo, Kang Kug;Park, Hyung Keun;Ahn, Byung Chul;Min, Byeong Uk
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.36 no.4
    • /
    • pp.705-713
    • /
    • 2016
  • For the soft ground construction, the factors not considered in the design stage occurs in the construction stage so that they cause the increase of the construction cost due to the structural stability and the design change. The subject of the study is the construction section of the industrial complex access road made in the Ochang region of Chungcheongbuk-do. The study is concerned with selecting the soft ground handling method such as the replacement method using rock debris and the surcharge reflecting the service load as the soft ground handling measure and analyzing the effect of reducing the construction cost with the stability of structures and the reduction of the construction period. The soft ground in the study section consists of sandy and cohesive soil and is 2.4m to 5.5m deep. It is distributed unevenly between the 1.5m to 5.9m stratums under the ground surface. Settlement is not serious, but the future uneven settlement and difference are expected so that the future settlement behavior is estimated by analyzing the site measurement results after the soft ground treatment. Moreover, in consideration of the regional characteristics and economic efficiency, soil with good quality is replaced with rock debris as the replacement material so that 29% of the construction cost is reduced due to the increase of stability and the reduction of duration. If the estimation of the dispersion of the pore water pressure within the dam body and the change of the underground water level and the relation of the actually measured soft ground with consolidation is studied further on the basis of the study, it is expected that the behavior of the soft ground will be correctly estimated in various site conditions.

A Study on the Development of Solid Reference Electrode and Remote Protection Potential Measuring System (고체기준전극 및 원격전위측정 시스템 개발에 관한 연구)

  • Ryou, Young-don;Kim, Jin-Jun;Kim, Dong-Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.3
    • /
    • pp.38-43
    • /
    • 2015
  • For buried gas pipelines, cathodic protection system shall be installed to protect against corrosion. The surveys of pipe-to-soil potentials for the gas pipelines should be carried out at the test box more than once a year. In urban, the test box is usually located on the driveway, therefore, it is difficult to measure the potentials. That is, traffic control is needed when carrying out the measurements of the potentials on daytime, or measurements of pipe-to-soil potentials at the test box located on the driveway have to be carried out in the late night when the traffic is light. We have developed remote potential monitoring system using the solid reference electrode and the wireless communication technology for the purpose of removing above problems. We have installed the developed solid reference electrodes at a site and monitored the potentials by wireless communication. Measured potential values were transferred to the server in office and analyzed. We have found the pipe-to-soil potentials transferred to the web server make no difference to the potentials measured directly on the site.

Study on Optimization of Detection System of Prompt Gamma Distribution for Proton Dose Verification (양성자 선량 분포 검증을 위한 즉발감마선 분포측정 장치 최적화 연구)

  • Lee, Han Rim;Min, Chul Hee;Park, Jong Hoon;Kim, Seong Hoon;Kim, Chan Hyeong
    • Progress in Medical Physics
    • /
    • v.23 no.3
    • /
    • pp.162-168
    • /
    • 2012
  • In proton therapy, in vivo dose verification is one of the most important parts to fully utilize characteristics of proton dose distribution concentrating high dose with steep gradient and guarantee the patient safety. Currently, in order to image the proton dose distribution, a prompt gamma distribution detection system, which consists of an array of multiple CsI(Tl) scintillation detectors in the vertical direction, a collimator, and a multi-channel DAQ system is under development. In the present study, the optimal design of prompt gamma distribution detection system was studied by Monte Carlo simulations using the MCNPX code. For effective measurement of high-energy prompt gammas with enough imaging resolution, the dimensions of the CsI(Tl) scintillator was determined to be $6{\times}6{\times}50mm^3$. In order to maximize the detection efficiency for prompt gammas while minimizing the contribution of background gammas generated by neutron captures, the hole size and the length of the collimator were optimized as $6{\times}6mm^2$ and 150 mm, respectively. Finally, the performance of the detection system optimized in the present study was predicted by Monte Carlo simulations for a 150 MeV proton beam. Our result shows that the detection system in the optimal dimensions can effectively measure the 2D prompt gamma distribution and determine the beam range within 1 mm errors for 150 MeV proton beam.

Experimental Study of Characteristics of Three-Ring Impedance Meter and Dependence of Characteristics on Electric Conductivity of Fluids (3-ring 임피던스미터의 유체 전기 전도도 독립성에 대한 실험적 연구)

  • Kim, Jong-Rok;Ahn, Yeh-Chan;Kim, Moo-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.11
    • /
    • pp.1027-1033
    • /
    • 2010
  • A two-phase (gas-liquid) flow is a common phenomenon in fluidic systems, e.g., fluidic systems in the electro-magnetic or nuclear power generation industry and in the steel industry. The measurement of a two-phase flow is important for guaranteeing the safety of the system and for achieving the desired performance. The measurement of the void fraction, which is one of the parameters of the two-phase flow that determines the pressure drop and heat transfer coefficient, is very important. The time resolution achieved by employing the impedance method that can be used to calculate the void fraction from the impedance of the fluid is high because the electric characteristics are taken into account. Therefore, this method can be employed to accurately measure the void fraction without distortion of flow in real time by placing electrodes on the walls of the tubes. Coney analytically studied a ring-type impedance meter, which can be employed in a circular tube. The aim of this study is to experimentally verify the robustness of a three-ring impedance meter to variations in the electric conductivity of the fluid; this robustness was suggested by Coney but was not experimentally verified.

A Study of Structural Stress Technique for Fracture Prediction of an Auto-Mobile Clutch Snap-Ring (클러치 스냅링부 파괴 예측을 위한 구조응력기법 연구)

  • Kim, Ju Hee;Myeong, Man Sik;Oh, Chang Sik;Kim, Yun Jae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.2
    • /
    • pp.175-183
    • /
    • 2016
  • The endurance reliability assessment of a highly complex mechanism is generally predicted by the fatigue life based on simple stress analysis. This study discusses various fatigue life assessment techniques for an automobile clutch snap ring. Finite element analyses were conducted to determine the structural stress on the snap ring. Structural stress that is insensitive in regards to the mesh size and type definition is presented in this study. The structural stress definition is consistent with elementary structural mechanics theory and provides an effective measure of a stress state that pertains to fatigue behavior of welded joints in the form of both membrane and bending components. Numerical procedures for both solid models and shell or plate element models are presented to demonstrate the mesh-size insensitivity when extracting the structural stress parameters. Conventional finite element models can be used with the structural stress calculations as a post-processing procedure. The two major implications from this research were: (a) structural stresses pertaining to fatigue behavior can be consistently calculated in a mesh-insensitive manner regardless of the types of finite element models; and (b) by comparing with the clutch snap-ring fatigue test data, we should predict the fatigue fractures of an automobile clutch snap ring using this method.