• 제목/요약/키워드: Safety measure

Search Result 1,839, Processing Time 0.024 seconds

Application of 630-nm and 850-nm Light-emitting Diodes and Microcurrent to Accelerate Collagen and Elastin Deposition in Porcine Skin

  • Kwon, Tae-Rin;Moon, Dong Wook;Kim, Jungwook;Kim, Hyoung Jun;Lee, Seong Jae;Han, Yunhee;Dan, Hee Won;Chi, Sang Hoon;Seong, Hwan Mo;Kim, Hee Jung;Lim, Guei-Sam;Lee, Jungkwan
    • Medical Lasers
    • /
    • v.10 no.2
    • /
    • pp.96-105
    • /
    • 2021
  • Background and Objectives Skin aging is reportedly associated with regulation in collagen and elastin synthesis. This study investigated the potential of combining light-emitting diode (LED) treatments using a 630-nm and 850-nm LED with simultaneous microcurrent application. Materials and Methods The dorsal skin of female pigs was treated with a home-use device. We examined the treatment effects using photography, thermocamera, microscopic pathology, and histological examination to determine the mechanism of action, efficacy, and safety of the procedure. A histological observation was performed using hematoxylin and eosin, Masson's trichrome, Victoria blue, and immunohistochemical staining. We also used the Sircol soluble collagen and elastin assay kit to measure the amounts of collagen and elastin in the porcine back skin tissue after 2 and 6 weeks. Results Evaluation by visual inspection and devices showed no skin damage or heat-induced injury at the treatment site. Histological staining revealed that accurate treatment of the targeted dermis layer effectively enhanced collagen and elastin deposition. Collagen type I, a protein defined by immunohistochemical staining, was overexpressed in the early stages of weeks 2 and 6. Combined therapy findings showed the superior capability of the 630-nm and 850-nm LED procedures to induce collagen; in contrast, elastin induction was more pronounced after microcurrent treatments. Conclusion The home-use LED device, comprising a combination of 630-nm and 850-nm LEDs and microcurrent, is safe and can be used as an adjunctive treatment for self-administered facial rejuvenation.

Technology to reduce water ingress for TBM cutterhead intervention

  • Ham, Soo-Kwon;kim, Beom-Ju;Lee, Seok-Won
    • Geomechanics and Engineering
    • /
    • v.29 no.3
    • /
    • pp.321-329
    • /
    • 2022
  • Tunnel site where high water pressure is applied, such as subsea tunnel, generally selects the shield TBM (Tunnel Boring Machine) to maintain the tunnel excavation face. The shield TBM has cutters installed, and the cutters wear out during the process of excavation, so it should be checked and replaced regularly. This is called CHI (Cutterhead Intervention). The conventional CHI under high water pressure is very disadvantageous in terms of safety and economics because humans perform work in response to high water pressure and huge water inflow in the chamber. To overcome this disadvantage, this study proposes a new method to dramatically reduce water pressure and water ingress by injecting an appropriate grout solution into the front of the tunnel face through the shield TBM chamber, called New Face Grouting Method (NFGM). The tunnel model tests were performed to determine the characteristics, injection volume, and curing time of grout solution to be applied to the NFGM. Model test apparatus was composed of a pressure soil tank, a model shield TBM, a grout tank, and an air compressor to measure the amount of water inflow into the chamber. The model tests were conducted by changing the injection amount of the grout solution, the curing time after the grout injection, and the water/cement ratio of grout solution. From an economic point of view, the results showed that the injection volume of 1.0 L, curing time of 6 hours, and water/cement ratio of the grout solution between 1.5 and 2.0 are the most economical. It can be concluded that this study has presented a method to economically perform the CHI under the high water pressure.

Low-level Laser Therapy with Novel Array of Light Source and Individualized Program for Treatment of Androgenetic Alopecia: A 16-week, Randomized, Double-blind, Sham Device-controlled Study

  • Kim, Jee-Woo;Kwon, Yeo-Seon;Chang, Yoon-Young;Hong, Sung-Ho;Shin, Jung-Won;Na, Jung-Im;Huh, Chang-Hun
    • Medical Lasers
    • /
    • v.9 no.2
    • /
    • pp.150-158
    • /
    • 2020
  • Background and Objectives Low-level laser therapy (LLLT) is used widely to promote hair growth in androgenetic alopecia (AGA). This study examined the clinical efficacy and safety of a home-use LLLT device with a newly designed array of light sources and software optimized for individual types of AGA. Materials and Methods The study was a randomized, double-blind, sham device-controlled trial. Forty-eight subjects (39 men and nine women) were assigned randomly in a 2:1 ratio to use either the test device (LG Pra'L HGN1, LG electronics, Korea) or sham device. The subjects used the LLLT device three times a week for 16 weeks. Phototrichogram was used to measure the hair density and hair thickness at 0, 8, and 16-weeks. Adverse events were closely monitored. Results After 16 weeks of using the device, the test group showed a significant increase in hair density and hair thickness compared to the control. In the test group, the hair density increased 6.96 counts/cm2 at eight weeks and 13.67 counts/cm2 at 16 weeks from the baseline. The hair thickness increased 7.21 ㎛ at eight weeks and 11.80 ㎛ at 16 weeks compared to the baseline. Conclusion The home-use LLLT device with a novel array of light sources and an individualized program according to the types of hair loss appears to be an effective and safe treatment modality for both male and female AGA patients.

Development of a Customized Beacon Equipped with a Strain Gauge Sensor to Detect Deformation of Structure Displacement (구조물의 변위 변형 감지를 위한 변형률 센서를 장착한 커스터마이징 비콘 개발)

  • Kim, Junkyeong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.5
    • /
    • pp.1-7
    • /
    • 2021
  • This study attempted to detect possible collapse and fire accidents in facilities for disaster monitoring of large facilities, and to develop a customized beacon to recognize the internal situation of an IoT-based facility when a disaster occurs. In the case of data measurement using the existing strain gauge sensor, the strain gauge sensor was connected by wire to measure it, but this study changed it to wireless so that the presence and absence of structural deformation can be monitored in real time. In this process, in order to use the Wheatstone bridge, a strain sensor module that can be connected to a customized beacon was manufactured, and a system configuration was conducted to remotely check the measurement data. To verify measurement data, 10 customized beacons and 2 gateways were installed on the 15th floor of the Advanced Institue of Convergence Technology, and as a result of analysis of measurement data, it was confirmed that the strain data values were distributed between 7 and 8.

Measuring rescuer's fatigue by evaluating varying sized groups of rescuers performing chest compressions on a manikin study for suspected COVID-19 patients (COVID-19 대응 심정지에서 가슴압박 교대 인원에 따른 구조자의 피로도 -마네킹 연구-)

  • Ahn, Hee-Jeong;Shim, Gyu-Sik;Bang, Sung-Hwan;Song, Hyo-Suk;Han, Seung-Eun
    • The Korean Journal of Emergency Medical Services
    • /
    • v.25 no.3
    • /
    • pp.81-92
    • /
    • 2021
  • Purpose: The aim of the study is to measure the quality of cardiopulmonary resuscitation (CPR) and the fatigue of rescuers wearing PPE (Level D) during a CPR session and to ultimately provide suggestions of safety standards for rescuers. Methods: 36 subjects were enrolled in the study. The subjects were divided randomly into three groups of two-members, three-members, and four-members. Each group performed CPR for 30 minutes. Blood lactate concentration, heart rate, rating of perceived exertion, chest compression depth and rate were measured before experiment and after each cycle. Results: There was a difference in the blood lactate concentration during CPR cycle by member of shifts (p=.014). The blood lactate concentration increased during CPR (p=.000). Subjective fatigue was a significant difference of chest compression in cycles 3, 4, and 5 for the member of shifts during CPR (p=.049, p=.009, p=.015). Depth and rate of chest compression were not different for the member of shifts during CPR. Conclusion: It is necessary to establish standards for the member of shifts during CPR, to reduce the fatigue of rescuers.

Measurement of Bangudae Rock Joint Using Non-adhesive, Non-contact Inclinometer Slope Laser Measuring System (비부착, 비접촉 방식의 계측기를 이용한 반구대암각화 암반 절리면의 계측)

  • Kim, Jae Hyun;Lee, Sang Ok;Chung, Kwang Yong;Han, Min Su
    • Journal of Conservation Science
    • /
    • v.37 no.6
    • /
    • pp.617-625
    • /
    • 2021
  • Daegokcheon Stream in Daegok-ri, Ulju-gun, is an area with a developed valley and bedrock from Gajisan Provincial Park to the confluence of the Taehwa River across the Yangsan Fault. To measure the rock of Bangudae petroglyphs, the mineralogical weathering, joints, and scours or cavities at the bottom were confirmed. The measurement was carried out for a short period of time on the joint of the bedrock on which the Bangudae petroglyphs were engraved. Compared to the measured value obtained using existing optical fiber (Ch4 150 ㎛), a displacement value of 300 ㎛ was obtained using the non-attached, non-contact type of measuring instrument. In the future, it is inferred that this instrument could be used for various cultural properties if the HSV-value suitable for illuminance and various measurement experiences are stored.

Integrated Rehabilitation for Children with Cerebral palsy: A Prospective Observational Study

  • Lee, Hye-Yoon;Yun, Young-Ju;Shin, Yong-Beom;Kim, Soo-Yeon;Han, Jun-hee;Yu, Sun-ae
    • The Journal of Korean Medicine
    • /
    • v.42 no.4
    • /
    • pp.61-74
    • /
    • 2021
  • Objectives: This study aimed to analyse: 1) the clinical effectiveness and safety of traditional Korean Medicine (TKM) and frequency of TKM therapies used and their relationship with conventional treatments. Methods: This prospective observational study enrolled children with cerebral palsy (CP) aged 6-78 months (n=126). The children who used herbal medication for >30 days or acupuncture treatment >12 sessions within 6 months were defined as the integrated rehabilitation (IR) group; the remaining participants were included in the conventional rehabilitation (CR) group. Results: Changes in the Gross Motor Function Measure-66 (GMFM-66) were greater in the IR group (6.4±6.1) than in the CR group (4.6±5.8). The reduction in the number of other health problems was greater in the IR group than in the CR group. The GMFM-66 improvement was greatest in gross motor function classification system level 1. There was no between-group difference in the frequency of rehabilitation therapy (10.9±6.6 and 12.0±9.9 in the IR and CR groups, respectively). Conclusion: TKM may offer additional benefits in terms of the GMFM-66 score and other health problems. However, there is a need for further randomized controlled trials involving a restricted CP type and a controlled treatment type and intensity to confirm these findings.

Development of Wireless ECG Clothing for Dogs with Improved Signal Detection (신호 감지성이 향상된 반려견용 무선 심전도 측정 의복 개발)

  • Kim, Soyoung;Lee, Okkyung;Kwon, Eunsun;Lee, Yejin;Min, Seungnam;Lee, Heeran
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.46 no.5
    • /
    • pp.760-771
    • /
    • 2022
  • This study sought to develop clothing for a companion animal that can provide stable ECG measurements. A pattern for the smart clothing of a companion dog was manufactured using the replica method to select a location and method that best suited the stable measurement of ECG and improved the clothing's fitness. The smart clothing was developed as the following three types: strap type, top type, and combined top and vest type with a detachable wireless ECG monitor. The detection abilities of these were observed using the PQRST rate taken after ECG measurements while the three companion dogs were tested while resting and moving. The results revealed that apart from using an electrode, applying a gel pad is the most effective way to achieve stable ECG measurements, and the central chest region is more reliable than the left armpit for providing steady readings. The combined top and vest type showed the highest average ECG PQRST detection number, meaning that the ECG signal measurement was steady. These results may contribute to the measurement of ECG in smartwear for U-Healthcare to measure other biometric data of a companion dog.

GM performance of the characteristics study by ship type for the stability support platform of the electronic inclinometer (전자식 경사계의 안정성 지원 플랫폼을 위한 선종별 GM 성능 특성 연구)

  • Kim, Mi-Joung;Jeon, Sung-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.12
    • /
    • pp.1920-1926
    • /
    • 2021
  • The electronic inclinometer can measure and print various output data related to the ship's heel, rolling cycle, and amplitude. The electronic inclinometer that can support ship stability judgment is equipped with a platform that supports stability for recovery performance, so it is possible to provide data even for small ships that lack ship stability judgment information. GM is an important factor in determining stability, and each type of ship has different GM scope. The purpose of this paper is to analyze GM according to the type of target ship and to review for a stable GM proposal. In addition, it is expected that GM data for each ship type will be embedded in the electronic inclinometer for ship that meets international standards, and will be used as data for securing and reviewing GM for strengthening ship safety

Experimental Study on Application of an Optical Sensor to Measure Mooring-Line Tension in Waves

  • Nguyen, Thi Thanh Diep;Park, Ji Won;Nguyen, Van Minh;Yoon, Hyeon Kyu;Jung, Joseph Chul;Lee, Michael Myung Sub
    • Journal of Ocean Engineering and Technology
    • /
    • v.36 no.3
    • /
    • pp.153-160
    • /
    • 2022
  • Moored floating platforms have great potential in ocean engineering applications because a mooring system is necessary to keep the platform in station, which is directly related to the operational efficiency and safety of the platform. This paper briefly introduces the technical and operational details of an optical sensor for measuring the tension of mooring lines of a moored platform in waves. In order to check the performance of optical sensors, an experiment with a moored floating platform in waves is carried out in the wave tank at Changwon National University. The experiment is performed in regular waves and irregular waves with a semi-submersible and triangle platform. The performance of the optical sensor is confirmed by comparing the results of the tension of the mooring lines by the optical sensor and tension gauges. The maximum tension of the mooring lines is estimated to investigate the mooring dynamics due to the effect of the wave direction and wavelength in the regular waves. The significant value of the tension of mooring lines in various wave directions is estimated in the case of irregular waves. The results show that the optical sensor is effective in measuring the tension of the mooring lines.