• Title/Summary/Keyword: Safety measure

Search Result 1,839, Processing Time 0.033 seconds

Comparison of Physical Properties of CFC Alternative Cleaning Solvents (CFC 대체세정제의 물성 비교)

  • Row, Kyung Ho;Lee, Youn Yong
    • Analytical Science and Technology
    • /
    • v.6 no.1
    • /
    • pp.65-75
    • /
    • 1993
  • A number of alternative cleaning solvents to CFC 113 which was identified as a ozone-depleting meterial were collected to measure their experimental physecal properties of density, surface tension, Refractive Index, boiling point, pH, viscosity, flash point, and soltbility. They might be classified as aqueous, simi-aqeous, alcohol ketone, and halogen cleaning solvents. The solubilities of abietic acid, a major component of flux used in PCB (Printed Circuit Board) of the electronic indystry, into the cleaning solvents including CFC 113 were determined for comparison. The assorted cleaning solvents have their own advantages and disadvantages. Therefore a end-user carefully needs to choose the best-fit cleaning solvent after the safety, stability, and economics as well as the effectiveness by physical properties of the alternative cleaning solvents are integratedly considered.

  • PDF

Development of the Personal Disaster Evacuation Apparatus in Case of the Life Damage by the landslide (I) - Focusing on the Load Weight and Material Test - (산사태로 인한 인명피해 대비 개인용 재난대피기구 개발 (I) - 재하하중 및 재료시험 중심으로 -)

  • Kim, Jung Meyon;Hwang, Dea Won;Park, Sung Yong;Lim, Chang Su;Yeon, Kyu Seok;Kim, Yong Seong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.58 no.5
    • /
    • pp.39-47
    • /
    • 2016
  • The houses are formed in the lower part of the mountain slope face in most agricultural areas of Korea, and old residents accounting for a large portion of the agricultural populations cannot respond to the evacuation quickly when the landslide happens, and the possibility the life damage occurs is high. Therefore, it is urgent to arrange the measure on this. This study is intended to develop the personal disaster evacuation apparatus that can be installed in the house to minimize the life damage by the landslide and to develop the self-initiative evacuation apparatus. This study suggested the load applicable to the personal disaster evacuation apparatus by quantitatively analyzing the effect of the load of rockslides and avalanches caused by the landslide on the structure. Also, the material property of materials was calculated through the tension and bending intensity test after making the specimen of glass fiber reinforced plastic (GFRP) member. The load weight and material property drawn from this study can be used as the basic material for the stability analysis of the personal disaster evacuation apparatus.

An Automatic Collision Avoidance System for Drone using a LiDAR sensor (LiDAR 센서를 이용한 드론 자동 충돌방지 시스템)

  • Chong, Ui-Pil;An, Woo-Jin;Kim, Yearn-Min;Lee, Jung-Chul
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.19 no.2
    • /
    • pp.54-60
    • /
    • 2018
  • In this paper, we propose an efficient automatic control method for the collision avoidance of drones. In general, the drones are controlled by transmitting to the flight control (FC) module the received PWM signals transmitted from a RC controller which transduce movements of the knob into PWM signal. We implemented the collision avoidance module in-between receiver and FC module to monitor and change the throttle, pitch and roll control signals to avoid drone collision. In order to avoid the collision, a LiDAR distance sensor and a servo-motor are installed and periodically measure the obstacle distance within -45 degrees from 45 degrees in flight direction. If the collision is predicted, the received PWM signal is changed and transmitted to the FC module to prevent the collision. We applied our proposed method to a hexacopter and the experimental results show that the safety is improved because it can prevent the collision caused by the inadvertency or inexperienced maneuver.

Analysis on the Effects of the Heat Loss Coefficient on the Operation Time of Sprinkler in Compartment Fire (구획 화재에서 스프링클러 열 손실계수 변화에 따른 작동 시간 분석)

  • You, Woo Jun
    • Fire Science and Engineering
    • /
    • v.32 no.5
    • /
    • pp.34-39
    • /
    • 2018
  • In this study, the experiment conditions for the variation of heat release rate in compartment space were constructed to analyze the effects of fire spread and the operation time of sprinkler in accordance with the heat loss of the sprinkler's heat element. The compartment composed of fire board (width = 0.3 m, height = 0.5 m, length = 3.0 m), are manufactured to measure the temperature distributions in the inner space, the mass loss rate and heat release rate during the experiment of N-heptane pool fire test. Also, the operation time of sprinkler is analyzed with the installation of sprinkler and C-factor using Fire Dynamics Simulator Ver.6 under the experiment conditions. The results show that the operation time of sprinkler, which has RTI $100(m{\cdot}s)^{0.5}$ operating temperature $70^{\circ}C$, is 30 s~60 s for C-factor = 0 and 1, 62 s~92 s for C-factor = 3, and 120 s over for C-factor = 5, respectively.

Electromagnetic Interactions between a Cellular Phone and the Human Body and Synthesis of a Bone-Equivalent Material (휴대폰 전자파와 인체의 상호 영향 및 뼈 유사 물질 합성 연구)

  • 윤용섭;김인광;전중창;박위상
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.10 no.2
    • /
    • pp.277-290
    • /
    • 1999
  • A simulation using the finite-difference time-domain method to analyze the electromagnetic interactions between a cellular phone and the human body was conducted, and a synthesis of a bone-equivalent material to make a human head phantom was performed. A test model of the cellular phone was fabricated to measure its reflection coefficient and radiation pattern in the free space. Various effects of the human body on the characteristics of the phone, such as input impedance, reflection coefficient, radiation pattern, and radiation efficiency are analyzed as the distance between the head and the phone antenna varies. When the phone was operated close to the head, the resonant frequency of the antenna decreased by up to 12%. With the output power of 0.6W, as long as the distance was larger than 30mm, the 1-g averaged peak SAR was below the ANSI/IEEE safety guideline, 1.6 W/kg. To synthesize the bone-equivalent material, an epoxy with hardener and a graphite powder were used as basis ingredients, and a small amount of a conducting epoxy was added to control the conductivity of the material. A material having a relative permittivity of 18.04 and a conductivity of 0.347, which are close to those of the bone at 850 MHz, was synthesized.

  • PDF

A Study on the Feasibility of Evaluating the Complexity of KTX Driving Tasks (KTX 운전직무에 대한 복잡도 평가 - 타당성 연구)

  • Park, Jin-Kyun;Jung, Won-Dea;Jang, Seung-Cheol;Ko, Jong-Hyun
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.5
    • /
    • pp.744-750
    • /
    • 2009
  • According to the result of related studies, the degradation of human performance has been revealed as one of the most significant causes resulting in the safety of any human-involved system. This means that preventing the occurrence of accidents/incidents through avoiding the degradation of human performance is prerequisite for their successive operation. To this end, it is necessary to develop a plausible tool to evaluate the complexity of a task, which has been known as one of the decisive factors affecting the human performance. For this reason, in this paper, the complexity of tasks to be conducted by KTX drivers was quantified by TACOM measure that is enable to quantify the complexity of proceduralized tasks being used in nuclear power plants. After that, TACOM scores about the tasks of KTX drivers were compared with NASA-TLX scores that are responsible for the level of a subjective workload to be felt by KTX drivers.

A Study on Standardization of Risk Management based on GIS for Railway HAZMAT Movement (GIS 기반 철도 위험물 수송의 위험도 관리 표준화 방안)

  • Paeng, Jung-Goang;Kim, Si-Gon;Park, Min-Kyu
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.1365-1375
    • /
    • 2009
  • The types and quantities of Hazmat and Hazmat transport are gradually increasing, keeping pace with industrialization and urbanization. There are currently more than 1,000 types of Hazmat,, and new types are added every year. At present the safety management for Hazmat transport only considers reducing accident probability, but even when an accident involving Hazmat-carrying vehicles occurs, that is not regarded as a Hazmat-related accident if the Hazmats do not leak out from the containers carrying them. Based on this principle, in turn., the methods to reduce risk (Risk=Probability$\times$Consequence) have to be developed by incorporating accident probability and consequence. By using Geographic Information System (GIS), a technical method was invented and is automatically able to evaluate the consequence by different types of Hazmat. Thus this study analyzed the degree of risk on the links classified by the Hazmat transport pathways. In order to mitigate the degree of risk, a method of 7-step risk management in transporting Hazmat on railway industries was suggested. The 7-step risk management is definded as the following: 1st step: buliding up GIS DB, 2nd step: calculating accident probability on each link, 3rd step: calculating consequence by Hazmat types, 4th step: determination of risk, 5th step: analysis of alternative plans for mitigating the risk, 6th: measure of effectiveness against each alternative, and 7th step: action plans to be weak probability and consequence by the range recommended from ALARP. In conclusion., those 7 steps are recommended as a standardization method in this study.

  • PDF

Evaluation of Local Velocity Gradient and Total Mass transfer Time at Various Rotating Velocity by Using Computational Fluid Dynamics (CFD를 이용한 패들교반속도에 따른 속도경사 및 총물질전달시간 산정)

  • Jun, Hang-Bae;Tian, Dong-Jie;Hong, Ki-Won;Han, Hong-Sig;Park, Byeong-Chang
    • Journal of Korean Society on Water Environment
    • /
    • v.30 no.2
    • /
    • pp.166-174
    • /
    • 2014
  • Velocity gradient, G, a measure of the average velocity gradient in the fluid has been applied for complete mixing of chemicals in mechanical mixing devices. G values were calculated by the power input transferred to fluid in turbulent and transient range. Chemical reactions occur so fast that total mass transfer time required for even distribution of the chemicals determine the overall reaction time. The total mass transfer time is composed of the time for complete mixing through the reactor and for diffusion of the chemicals into the eddy. Complete mixing time was calculated by CFD (computer fluid dynamics) and evaluated by tracer tests in 2 liter jars at different rotating speeds. Turbulent range, Reynolds number above 10,000 in regular 2 liter jars occurred at revolution speed above 100 rpm (revolution per minute), while laminar range occurred at revolution speed below 10 rpm. A typical range of rotating speed used in jar tests for water and wastewater treatment was between 10 and 300 rpm, which covered both transient and turbulent range. G values supplied from a commercial jar test apparatus showed big difference from those calculated with power number specially in turbulent range. Diffusion time through eddy decreased 1.5 power-law of rotating speed. Complete mixing time determined by pumping number decreased increases in rotating speed. Total mass transfer time, finally, decreases as rotating speed increases, and it becomes 1 sec at rotating speed of 1,000 rpm. Complete mixing times evaluated from tracer tests showed higher than those calculated by power number at higher rotating speed. Complete mixing times, however, calculated by CFD showed similar to those of experimentally evaluated ones.

The Active Measure of the Operation of the Volunteer Fire Brigade in Korea (우리나라 의용소방대의 활성화 방안 고찰)

  • Jeong, Gi-Sung
    • Fire Science and Engineering
    • /
    • v.23 no.5
    • /
    • pp.138-142
    • /
    • 2009
  • The system of The Volunteer Fire Brigade is the Civil autonomic one which was set up from The Chosun Dynasty and has been active. Having suffered from several dificulties from Japanese control in the Chosun Dynasty, The Volunteer Fire Brigade was established by the enactment 1958 Fire Law and we have had it up to this time. The Volunteer Fire brigade played an important role in the period of the past Fire fighting personnel and equipment which we did not have. It has carried out the assistance of the Fire extinction, the early extinction of a fire in the rural region, the extinction of the forest fire, and lots of social volunteering actions etc. but, today's Fire fighting system has made the surprising developments, such as the improvement of national economic power, the increase of knowledge about the safety of the people, the openness of The Fire Fighting Department of Korea. I will try to check out the role of The Volunteer Fire Brigade which filled up the lacking part the fire fighting in the past and make the measures which can activate in these days, looking for the new field of the movement.

A study on the Development of Smoke Detector Sensitivity Test Equipment (휴대용 연기감도시험기 개발에 관한 연구)

  • Kim, Hyeong-Gweon;Kwon, Seong-Pil;Yoon, Hun-Ju;SaKong, Seong-Ho
    • Fire Science and Engineering
    • /
    • v.23 no.5
    • /
    • pp.125-132
    • /
    • 2009
  • In this study we could contribute to the development of a precise checking tool with which the reliability of the automatic fire detection systems was enhanced and the safety of the people was ensured. In the same way as the domestic technical standard, the portable smoke sensitivity tester, which was developed in this work, could be used to check the capability of the smoke detectors installed in the field. Its heater inside was warmed up to $400^{\circ}C$ in 40 seconds and the paper as a smoke source was burned to produce smoke for the test. With the Photoelectric smoke detector it was possible to measure and control the smoke concentration in a range from 0%/m to 25%/m. With the adjustment of rpm of the fan, it was possible to keep a constant wind velocity in a range from 20cm/sec to 40cm/sec.