• Title/Summary/Keyword: Safety lines

Search Result 564, Processing Time 0.03 seconds

Oxidative DNA Damage from Nanoparticle Exposure and Its Application to Workers' Health: A Literature Review

  • Rim, Kyung-Taek;Song, Se-Wook;Kim, Hyeon-Yeong
    • Safety and Health at Work
    • /
    • v.4 no.4
    • /
    • pp.177-186
    • /
    • 2013
  • The use of nanoparticles (NPs) in industry is increasing, bringing with it a number of adverse health effects on workers. Like other chemical carcinogens, NPs can cause cancer via oxidative DNA damage. Of all the molecules vulnerable to oxidative modification by NPs, DNA has received the greatest attention, and biomarkers of exposure and effect are nearing validation. This review concentrates on studies published between 2000 and 2012 that attempted to detect oxidative DNA damage in humans, laboratory animals, and cell lines. It is important to review these studies to improve the current understanding of the oxidative DNA damage caused by NP exposure in the workplace. In addition to examining studies on oxidative damage, this review briefly describes NPs, giving some examples of their adverse effects, and reviews occupational exposure assessments and approaches to minimizing exposure (e.g., personal protective equipment and engineering controls such as fume hoods). Current recommendations to minimize exposure are largely based on common sense, analogy to ultrafine material toxicity, and general health and safety recommendations.

Study on the Negligible Extent(NE) and Release Characteristic of KS C IEC 60079-10-1(2015) Standard (KS C IEC 60079-10-1 규격의 무시할 수 있는 정도와 누출특성에 관한 연구)

  • Cho, Pil-rae;Lee, Hyang-jig;Baek, Jong Bae
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.2
    • /
    • pp.111-117
    • /
    • 2020
  • When KS C IEC 60069-10-1(2015) standard is applied to estimate a hazardous area, the chart showing the relationship between a hazardous area distance and release characteristic is used as a guide to determine the extent of hazardous zones for various forms of release. Three release characteristic lines based on the three types of release as an unimpeded jet release with high velocity, a diffusive jet release with low velocity, and a release of heavy gases or vapours that spread along horizontal surfaces are given. As these characteristic lines have the low limit threshold, it is difficult to estimate the hazardous area distance when the value of release characteristic is under the low limit threshold. And KS C IEC 60079-10-1(2015) standard shows the concept for a zone of Negligible extent(NE) which can be considered as non hazardous area, but it is also difficult to apply the concept of a Negligible extent. The purpose of this paper is to suggest the guideline for the release characteristic to decide a hazardous area distance and the Negligible extent(NE) being considered as non-hazardous area when deciding a hazardous area distances by the KS C IEC 60079-10-1 standard.

Evaluation of Suitability of Retroreflective Material Locations by Motion Analysis of the Wearer of Safety Clothing (안전의복 착용자의 동작분석에 의한 재귀반사 소재 위치의 적합성 평가)

  • Soon Ja Park;Satoko Tanabe;Mariko Sato
    • Human Ecology Research
    • /
    • v.61 no.3
    • /
    • pp.493-503
    • /
    • 2023
  • Since ISO 20471 regulations(2013) were enacted, high-visibility clothing made of fluorescent fabric and retroreflective materials has been standardized to distinguish the wearers from the surrounding background in a dark place and to protect them. Accordingly, we made high-visibility safety clothing based on the international standards, and examined the positions of the retro-reflective materials on the attached sites to evaluate the suitability of the positions, by 3 types of safety clothing and the body regions when the wearers work or move. Two retro-reflective films of 5cm-horizontal lines were attached to the front/back of the upper-wear, and the lower-wear. Vertical lines were attached from the shoulder to the horizontal waistline. To analyze the motion in 3-dimension, we took pictured infrared-reflective markers on the retro-reflective film covered with yellow-tape on the front-side when 6 subjects wearing experimental garments performed 6 types of motions. According to the metronome tempo, the motions were performed for 30 seconds and repeated 6 motions ①~⑥ by 3 experimental clothing. Among the 6 motions, significant differences in the appearance rate of the markers by body region during the motions were found in 5 types except for motion ③. Significant differences by the post-hoc test were shown in motions ④ and ⑥ as well. Therefore, for high-visibility safety clothing, it is necessary to anticipate the worker's motion and consider the attaching position of the retro-reflective material. It is considered desirable to attach the retro-reflective materials to several places where the clothing is hard to wrinkle.

A Study on the Electrical Fire Risk Assessment Methods of LED Lightings for Outdoor (옥외용 LED 조명의 전기화재 위험성 평가기법에 관한 연구)

  • Kim, Hyang-Kon;Kim, Dong-Ook;Choi, Hyo-Sang
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.3
    • /
    • pp.674-679
    • /
    • 2011
  • In this paper, we experimented and analyzed about electric fire risk assessment methods of LED lightings for outdoor. LED lighting is composed of AC power lines, AC/DC converter, DC power lines and LED lamps. There are some risk factors of electric fire in LED lighting such as short circuit between power lines or power line and ground, dielectric breakdown, leakage current, abnormal voltage inflow, poor contacts(connections), etc. As a result of this study, insulation coverings of wire was ignited due to dielectric breakdown between power lines and molten marks were formed in copper conductor. LED lighting was blown out while short circuit, beside that, electrical disorder did not occur. When abnormal voltage was inflowed, electronic components such as varistor, condenser were damaged. Partial heating was produced and insulation was melted and carbonized by arc and heating while poor contacts were happened. We expect that the results of this study would be helpful for electrical safety of LED lightings for outdoor.

Various Factors Influencing the Lifetime of Suspension-Type Porcelain Insulators for 154 kV Power Transmission Lines

  • Choi, In Hyuk;Park, Joon Young;Kim, Tae Gyun;Yoon, Yong Beum;Yi, Junsin
    • Transactions on Electrical and Electronic Materials
    • /
    • v.18 no.3
    • /
    • pp.151-154
    • /
    • 2017
  • In this article, we investigated the various influencing factors that degraded the lifetime of suspension insulators in 154 kV transmission lines, and showed the possible solutions to avoid such breakdowns. With respect to achieve safety, reliability and aesthetical considerations, the characteristics of transmission and distribution network power cables should be improved. Suspension insulators are particularly important to study, as they have developed to be the main component of transmission lines due to their ability to withstand the electrical conductivity of high-voltage power transmission. Suspension insulators are mostly made from glass, rubber and ceramic material due to their high resistivity. In Korea, porcelain suspension insulators are typically used in the transmission line system, as they are cheaper and more flexible compared to other types of insulators. This is effective from preventing very high and steep lightening impulse voltages from causing the breakdown of suspension insulators used in power lines. Other influential factors affect the lifetime of suspension insulators that we studied include temperature, water moisture, contamination, mechanical vibration and electrical stress.

Effect of Phaleria nisidai Extracts on Cell Viability of Pancreatic Beta Cell Lines

  • Kim, Seong-Sun;Jeon, Yong-Deon;Kitalong, Christopher;Jin, Jong-Sik
    • Proceedings of the Plant Resources Society of Korea Conference
    • /
    • 2019.10a
    • /
    • pp.106-106
    • /
    • 2019
  • The leaves of Phaleria nisidai Kaneh. have been used as a beverage for tonic and immune-enhancing effect in Palau. Recently, extract of the plants showed anti-diabetic effect in clinical trial and possibility could be used as a medicine for diabetes. However, in vitro and in vivo experiments which elucidate cytotoxicity and biological mechanism have not been studied yet. To begin the series of in vitro and in vivo anti-diabetic studies, we evaluated cell viability of pancreatic beta cell lines to figure it out toxicity of the extract. The leaves of Phaleria nisidai were extracted with distilled water and 70% EtOH, and followed by evaporation and lyophilization. And, MIN6 and RIN-m5F cell lines were used for assessment of cell viability. MTT assay was adopted to evaluated a toxicity. Any of extract and concentration used in this study did not show cytotoxicity in the cell lines. Furthermore, morphological change was not observed. These results means Phaleria nisidai might be a medicinal resource when further biological and safety studies would be performed.

  • PDF

A Study on the Ignition and Molten Mark Analysis of Ballast for Fluorescent Lamp (형광등용 안정기의 발화 및 용융흔 분석에 관한 연구)

  • 최충석;박창수;김혁수;김향곤;정재희
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 1998.11a
    • /
    • pp.173-177
    • /
    • 1998
  • In this paper, we reported an outbreak of fire hazard of ballast for fluorescent lamp. The surface structure and composition of ballast coil analyzed by using metallurgical microscope, scanning electron microscope(SEM) and energy dispersive x-ray spectroscopy(EDX). The surface of molten mark appeared columnar structure and void. EDX analysis indicated that the molten mark spectra were composed not only of the corresponding original spectra but also of several new lines.

  • PDF

Fuzzy Logic in Nuclear Safety Issues

  • Ruan, Da
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.7 no.1
    • /
    • pp.34-44
    • /
    • 1997
  • The Belgian Nuclear Research Centre(SCK${\cdot}$CEN) has been a pioneer of the peaceful uses of nuclear energy after over forty years of existence. Recently, SCK${\cdot}$CEN's financial support of doctoral and postdoctoral research in close collaboration with universities has been a vital ingredient for securing a quality profile committed to the pursuit of execllence. FLINS, Fuzzy Logic and Intelligent technologies in Nuclear Science, was initially built within one of the postdoctoral research project at SCK${\cdot}$CEN. Among SCK${\cdot}$CEN's activities which will have an important impact on its scientific future, the application of fuzzy logic and intelligent technologies in nuclear science and engineering opens new domains in radiation protection, safety assessment, human reliability, nuclear reactor control, waste and disposal, etc. In this paper, we review the available literature on fuzzy logic in nuclear applications. We then present the initiative of R&D on fuzzy logic applications at SCK${\cdot}$CEN, namely, (1) safety control for a nuclear reactor, and (2) a safety evaluation model for nuclear transmission lines. By these two examples of nuclear applications, we illustrate the potential use of fuzzy logic in nuclear safety issues.

  • PDF

Prevention Techniques of Electrical Fire and Electrical Shock Caused by Leakage Current (누설전류로 인한 전기화재 및 감전사고 예방기법)

  • Kim, Dong-Woo;Lim, Young-Bea;Lee, Sang-Ick;Kim, Jae-Hyun;Kang, Dae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.6
    • /
    • pp.82-87
    • /
    • 2013
  • Electrical leakage happens when faults in electrical apparatus or power lines occur. It causes electrical fires and electric shocks. In order to reduce accidents caused by electrical leakage current, it is important to detect faults effectively and shut off the power. In this paper, firstly we analyzed statistics of electrical fires and electric shocks caused by electrical leakage current. Secondly, standards of allowable leakage current and body impedance models were analyzed. Lastly, effective application methods for breaking electrical leakage current were suggested. The results will provide useful preventive measures of electrical fires and electric shocks caused by electrical leakage.

A Study on Improvement of Criteria for Mooring Safety Assessment in Single Point Mooring

  • Lee, Sang-Won;Kim, Young-Du
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.25 no.3
    • /
    • pp.287-297
    • /
    • 2019
  • The recent increase in crude oil trading has led to an increase in the workings of SPM for crude oil carriers. VLCCs generally encounter difficulty entering port due to limitations in terms of sea depth and maneuverability. The SPM is a system that allows mooring to the buoy located in the outer sea for such vessels. However, the buoy is more affected by relatively external forces because of their of shore location. Therefore, the safety assessment of SPM is particularly important as it can lead to large oil pollution disasters in the event of SPM accidents. Despite this, in the implementation of the Marine Traffic Safety Audit Scheme in Korea, there exists no guidance for SPM. In this study, a SPM mooring safety assessment is performed using OPTIMOOR, a numerical analysis program, so as to understand the mooring characteristics of SPM. As a result, it is confirmed that the tension of mooring lines and hull movement in the SPM are greatly affected by the encounter angles with external forces. In addition, it is found that the maximum tension of the mooring line is elevated as the water depth becomes shallower through sensitivity analysis. According to SPM characteristics, which has a large influence on the encounter angle, this study has proposed an amendment to setting criteria in the implementation of the Maritime Traffic Safety Audit Scheme which could improve the reliability and accuracy of mooring safety assessments.