• 제목/요약/키워드: Safety integrity level

검색결과 158건 처리시간 0.026초

안전무결성 수준 및 MTTFd를 활용한 개발단계의 고성능 지상체 신뢰도 예측 방안 (Reliability Prediction of High Performance Mooring Platform in Development Stage Using Safety Integrity Level and MTTFd)

  • 이민영;김상부;배인화;강소연;곽우영;이성근;오극기;최대림
    • 한국산업융합학회 논문집
    • /
    • 제27권3호
    • /
    • pp.609-618
    • /
    • 2024
  • System reliability prediction in the development stage is increasingly crucial to reliability growth management to satisfy its target reliability, since modern system usually takes a form of complex composition and various complicated functions. In most cases of development stage, however, the information available for system reliability prediction is very limited, making it difficult to predict system reliability more precisely as in the production and operating stages. In this study, a system reliability prediction process is considered when the reliability-related information such as SIL (Safety Integrity Level) and MTTFd (Mean Time to Dangerous Failure) is available in the development stage. It is suggested that when the SIL or MTTFd of a system component is known and the field operational data of similar system is given, the reliability prediction could be performed using the scaling factor for the SIL or MTTFd value of the component based on the similar system's field operational data analysis. Predicting a system reliability is then adjusted with the conversion factor reflecting the temperature condition of the environment in which the system actually operates. Finally, the case of applying the proposed system reliability prediction process to a high performance mooring platform is dealt with.

기능적 안전을 고려한 FSA기반 기관 구역 화재 안전성 평가 및 개선 (Fire Safety Assessment Based on FSA and Risk Reduction of Machinery System Considering Functional Safety)

  • 서성원;양영순;정소연;유원선
    • 대한조선학회논문집
    • /
    • 제49권3호
    • /
    • pp.239-246
    • /
    • 2012
  • It is the well-known fact that most part of goods transported are moved on the unfavorable ocean and even a small amount of accident on sea is extremely dangerous for human lives, financial losses, and social responsibility. Among the several causes of accidents, those by fire have occurred frequently and their damage has been highly serious. The aim of this paper is to assess the risk of fires due to oil leakage in the machinery space. To define the possible fire scenario, our team has performed the search of casualty database and reviewed the previous and various studies in the field. As a result, it is noted that the quantitative risk of the fire scenario have been evaluated on the ground of the FSA risk model. The expected frequency of a fire amounts to incidents during the life of a ship, and the expected financial damage amounts to 5,654 USD per a ship. By adopting Safety Instrumented System (SIS) introduced in IEC 61508 and IEC 61511, SIS model is designed to prevent oil leakage fire as a risk reduction method. It is concluded that System Integrity Level (SIL) 1 seems to be appropriate level of SIS.

Development of a Quality Assurance Safety Assessment Database for Near Surface Radioactive Waste Disposal

  • Park J.W.;Kim C.L.;Park J.B.;Lee E.Y.;Lee Y.M.;Kang C.H.;Zhou W.;Kozak M.W.
    • Nuclear Engineering and Technology
    • /
    • 제35권6호
    • /
    • pp.556-565
    • /
    • 2003
  • A quality assurance safety assessment database, called QUARK (QUality Assurance Program for Radioactive Waste Management in Korea), has been developed to manage both analysis information and parameter database for safety assessment of low- and intermediate-level radioactive waste (LILW) disposal facility in Korea. QUARK is such a tool that serves QA purposes for managing safety assessment information properly and securely. In QUARK, the information is organized and linked to maximize the integrity of information and traceability. QUARK provides guidance to conduct safety assessment analysis, from scenario generation to result analysis, and provides a window to inspect and trace previous safety assessment analysis and parameter values. QUARK also provides default database for safety assessment staff who construct input data files using SAGE(Safety Assessment Groundwater Evaluation), a safety assessment computer code.

Vessel failure sensitivities of an advanced reactor for SBLOCA

  • Jhung, Myung Jo;Oh, Chang-Sik;Choi, Youngin;Kang, Sung-Sik
    • Nuclear Engineering and Technology
    • /
    • 제52권1호
    • /
    • pp.185-191
    • /
    • 2020
  • Plant-specific analyses of an advanced reactor have been performed to assure the structural integrity of the reactor pressure vessel during transient conditions, which are expected to initiate pressurized thermal shock (PTS) events. The vessel failure probabilities from the probabilistic fracture mechanics analyses are combined with the transient frequencies to generate the through-wall cracking frequencies, which are compared to the acceptance criterion. Several sensitivity analyses are performed, focusing on the orientations and sizes of cracks, the copper content, and a flaw distribution model. The results show that the integrity of the reactor vessel is expected to be maintained for long-term operation beyond the design lifetime from the PTS perspective using the design data of the advanced reactor. Moreover, a fluence level exceeding 9×1019 n/㎠ is found to be acceptable, generating a sufficient margin beyond the design lifetime.

Analyses on Thermal Stability and Structural Integrity of the Improved Disposal Systems for Spent Nuclear Fuels in Korea

  • Lee, Jongyoul;Kim, Hyeona;Kim, Inyoung;Choi, Heuijoo;Cho, Dongkeun
    • 방사성폐기물학회지
    • /
    • 제18권spc호
    • /
    • pp.21-36
    • /
    • 2020
  • With respect to spent nuclear fuels, disposal containers and bentonite buffer blocks in deep geological disposal systems are the primary engineered barrier elements that are required to isolate radioactive toxicity for a long period of time and delay the leakage of radio nuclides such that they do not affect human and natural environments. Therefore, the thermal stability of the bentonite buffer and structural integrity of the disposal container are essential factors for maintaining the safety of a deep geological disposal system. The most important requirement in the design of such a system involves ensuring that the temperature of the buffer does not exceed 100℃ because of the decay heat emitted from high-level wastes loaded in the disposal container. In addition, the disposal containers should maintain structural integrity under loads, such as hydraulic pressure, at an underground depth of 500 m and swelling pressure of the bentonite buffer. In this study, we analyzed the thermal stability and structural integrity in a deep geological disposal environment of the improved deep geological disposal systems for domestic light-water and heavy-water reactor types of spent nuclear fuels, which were considered to be subject to direct disposal. The results of the thermal stability and structural integrity assessments indicated that the improved disposal systems for each type of spent nuclear fuel satisfied the temperature limit requirement (< 100℃) of the disposal system, and the disposal containers were observed to maintain their integrity with a safety ratio of 2.0 or higher in the environment of deep disposal.

LOPA 및 SIF기법에 의한 LPG 인수기지의 안전성향상에 대한 연구 (Safety Enhancement of LPG Terminal by LOPA & SIF Method)

  • 이일재;김래현
    • Korean Chemical Engineering Research
    • /
    • 제53권4호
    • /
    • pp.431-439
    • /
    • 2015
  • 본 연구에서는 LPG(Liquefied Petroleum Gas) 인수기지에 대해 HAZOP(Hazard and Operability), LOPA(Layer of Protection Analysis) 및 SIL(Safety Integrity Level) 위험성 평가기법을 적용하여, 국내 LPG 인수기지 중 사고발생시 피해영향이 가장 큰 부탄 및 프로판 저장탱크를 중심으로, 사고위험성을 감소시킬 수 있는 방안을 고찰하였다. HAZOP 기법을 통해 잠재위험성을 분석하여 사고시나리오를 도출하고, 사고피해영향이 큰 시나리오를 선정하여 LOPA를 분석하였다. LOPA 분석시에는 해당시나리오에 대한 IPL(Independent Protection Layer)을 분석하여 완화된 결과의 빈도를 도출한 후, 설정된 위험성 허용기준($1.0{\times}10^{-05}$/년)에 대한 충족여부를 판단하였다. LOPA의 독립방호계층으로서 SIF(Safety Instrumented Functions)의 경제성을 분석하여 SIF가 현장의 특성에 맞는 IPL이 되도록 개선안을 제시하였다. 또한, 독립방호계층으로서 해당공정에 사용된 SIF의 수준을 분석해보고, SIF의 수준에 따라 공정의 사고발생빈도가 어느 정도 변화하는지를 당해 공정에서 도출된 사고시나리오를 중심으로 연구하였다.

Use of hazardous event frequency to evaluate safety integrity level of subsea blowout preventer

  • Chung, Soyeon;Kim, Sunghee;Yang, Youngsoon
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제8권3호
    • /
    • pp.262-276
    • /
    • 2016
  • Generally, the Safety Integrity Level (SIL) of a subsea Blowout Preventer (BOP) is evaluated by determining the Probability of Failure on Demand (PFD), a low demand mode evaluation indicator. However, some SIL results are above the PFD's effective area despite the subsea BOP's demand rate being within the PFD's effective range. Determining a Hazardous Event Frequency (HEF) that can cover all demand rates could be useful when establishing the effective BOP SIL. This study focused on subsea BOP functions that follow guideline 070 of the Norwegian Oil and Gas. Events that control subsea well kicks are defined. The HEF of each BOP function is analyzed and compared with the PFD by investigating the frequency for each event and the demand rate for the components. In addition, risk control options related to PFD and HEF improvements are compared, and the effectiveness of HEF as a SIL verification for subsea BOP is assessed.

철도신호시스템의 정량적 분석 기법을 통한 SIL 도출방안 검토 (Quantitative analysis to derive SIL in the railway signalling system)

  • 정의진;김양모
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.1303-1305
    • /
    • 2003
  • It is very important to ensure system safety during the process of developing a system. Railway system is also devoting a great portion for the safety. Nowadays many countries leading railway industry have their own system assessment principles according to the situation of their train control systems. In this paper, several principles to derive Safety Integrity Level (SIL) are represented in the railway signalling system. The characteristics of those principles are also considered respectively.

  • PDF

TFM에 대한 내장형제어기의 위험측고장률 예측에 관한 연구 (A study on a Prediction of Dangerous Failure Rate in the Embedded System for the Track Side Functional Module)

  • 신덕호;이재훈;이기서
    • 한국철도학회논문집
    • /
    • 제8권2호
    • /
    • pp.170-175
    • /
    • 2005
  • This study presents a prediction of a failure rate in a safety required system that consists of a embedded control system, requiring a satisfaction of a quantitative safety requirement. International Standards are employed to achieve a regular procedures in the whole life cycle of a system, for the purpose of a prediction and a evaluation of a fault that might be able to be happened in a system. This International Standards uses SIL (Safety Integrity Level) to evaluate a safety level of a system. SIL is divided into 4 levels, from level 1 to level 4, and each level has functional failure rate and dangerous failure rate of a system. In this paper we describe the conventional method to predict the dangerous failure rate and propose a method using hazard analysis to predict the dangerous failure rate. The conventional method and the technique using hazard analysis to predict the dangerous failure rate are made a comparison through the control modules of the interlocking system in KTX. The proposed method verify better effectiveness for the prediction of the dangerous failure rate than that of the conventional method.

Localization Requirements for Safe Road Driving of Autonomous Vehicles

  • Ahn, Sang-Hoon;Won, Jong-Hoon
    • Journal of Positioning, Navigation, and Timing
    • /
    • 제11권4호
    • /
    • pp.389-395
    • /
    • 2022
  • In order to ensure reliability the high-level automated driving such as Advanced Driver Assistance System (ADAS) and universal robot taxi provided by autonomous driving systems, the operation with high integrity must be generated within the defined Operation Design Domain (ODD). For this, the position and posture accuracy requirements of autonomous driving systems based on the safety driving requirements for autonomous vehicles and domestic road geometry standard are necessarily demanded. This paper presents localization requirements for safe road driving of autonomous ground vehicles based on the requirements of the positioning system installed on autonomous vehicle systems, the domestic road geometry standard and the dimensions of the vehicle to be designed. Based on this, 4 Protection Levels (PLs) such as longitudinal, lateral, vertical PLs, and attitude PL are calculated. The calculated results reveal that the PLs are more strict to urban roads than highways. The defined requirements can be used as a basis for guaranteeing the minimum reliability of the designed autonomous driving system on roads.