• Title/Summary/Keyword: Safety Secure

Search Result 1,419, Processing Time 0.029 seconds

A Study on the Fire Life Safety Improvement in Deteriorated Buildings - Focus on the Jongro Goshiwon Fire Analysis (노후 건축물의 화재인명안전 개선방안에 관한 연구 - 종로 고시원 화재사고의 분석을 중심으로 -)

  • Choi, Doo Chan
    • Fire Science and Engineering
    • /
    • v.32 no.6
    • /
    • pp.63-68
    • /
    • 2018
  • In this study, to recognize the limitations and problems of fire safety in existing deteriorated buildings in Korea, and to analyze the fire case of Jongno Gooshiwon, the fire life safety assessment was performed and analyzed through fire egress simulation and analyzed the domestic and foreign related codes and regulations. In order to secure the fire safety of existing deteriorated buildings, it is necessary to adopt the systematic introduction and application of fire safety performance evaluation of buildings based on quantitative and objective indicated method for performance maintenance and management for fire life safety.

A Study on the Quantitative Risk Assessment of Mobile Hydrogen Refueling Station (이동식수소스테이션 정량적 위험성평가에 관한 연구)

  • KIM, DONG-HWAN;LEE, SU-MIN;JOE, CHOONG-HEE;KANG, SEUNG KYU;HUH, YUN-SIL
    • Journal of Hydrogen and New Energy
    • /
    • v.31 no.6
    • /
    • pp.605-613
    • /
    • 2020
  • In July and October of this year, the government announced the 'Green new deal plan within the Korean new deal policy' and 'Strategies for proliferation of future vehicles and market preoccupation'. And, in response to changes in the global climate agreement, it has decided to expand green mobility such as electric vehicles and hydrogen electric vehicles with the aim of a "net-zero" society. Accordingly, the goal is to build 310 hydrogen refueling stations along with the supply of 60,000 hydrogen vehicles in 2022, and the hydrogen infrastructure is being expanded. however, it is difficult to secure hydrogen infrastructure due to expensive construction costs and difficulty the selection of a site. In Korea, it is possible to build a mobile hydrogen station according to the safety standards covering special case of the Ministry of Industry. Since the mobile hydrogen station can be charged while moving between authorized place, it has the advantage of being able to meet a large number of demands with only one hydrogen refueling station, so it is proposed as a model suitable for the early market of hydrogen infrastructure. This study demonstrates the establishment of a hydrogen refueling station by deriving a virtual accident scenario for leakage and catastrupture for each facility for the risk factors in a mobile hydrogen station, and performing a quantitative risk assessment through the derived scenario. Through the virtual accident scenario, direction of demonstration and implications for the construction of a mobile hydrogen refueling station were derived.

Development of Standards for the Use of Liquefied Hydrogen for Ship Using Risk Assessment Techniques (위험성 평가기법을 활용한 선박용 액화수소 사용시설 기준개발)

  • Young-taeg, Hur;Hye-Soo, Han;Gyoung-min, Noh;Hee-soo, Chung;Chung-keun, Chae
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.6
    • /
    • pp.52-58
    • /
    • 2022
  • According to the government's roadmap for revitalizing the hydrogen economy, various industries carry out projects using liquefied hydrogen as an energy source. However, safety standards necessary for operational demonstration projects are not prepared in Korea, thus, it is necessary to prepare safety standards as soon as possible. Therefore, in order to secure the safety of liquefied hydrogen instrumentation and handling facilities, it is necessary to prepare safety standards that comprehensively consider the risk of liquefied hydrogen. This study aims to prioritize safety standard items using ETA, FMEA, and AHP, which are risk assessment techniques, to present the feasibility of selecting safety standard items.

Acute toxicity test and safety classification for Termitomyces albuminosus containing pharmacologically similar ingredient of Aconitum koreanum (백부자-대체 가능 한약재의 계종버섯에 대한 급성독성시험과 안전성등급화)

  • An, Minji;Park, Yeongchul
    • The Korea Journal of Herbology
    • /
    • v.32 no.4
    • /
    • pp.33-38
    • /
    • 2017
  • Objectives : Termitomyces albuminosus (Berk.) Heim is one of the famous wild edible mushrooms in the southern part of China. It is known that Termitomyces albuminosus, like Aconitum koreanum used in Korean traditional medicine, contains a kind of cerebroside, termitomycesphin, causing a pharmacologic effect on the neuron system. The pharmacologic effect of Termitomyces albuminosus can be used to possibly replace Aconitum koreanum. However, It needs to be certified as safe before it can be used. Here, a single-oral toxicity test and safety classification was conducted to obtain acute information of the toxicity of dried-Termitomyces albuminosus powder and to secure its safety in clinical applications. Methods : In order to calculate approximate lethal dose(ALD), test substance was orally administered to male and female SD-rat at dose levels of 5,000 and 0 (vehicle control) mg/kg (body weight). Based on the result of this toxicity, also the estimation of safety classification was calculated using the HED-based (human equivalent dose) MOS (margin of safety). Results : There were no mortalities, test substances treatment-related clinical signs, no changes in the body or organ weights, and no gross or histopathological findings at 14 days after treatment with test substance. Thus, the approximate lethal dose of dried-Termitomyces albuminosus powder was considered over 5,000 mg/kg in both female and male mice. Conclusions : Based on the limit dose, 5000 mg/kg, it was estimated that dried-Termitomyces albuminosus powder is classified as "Specified class B" indicating that clinical dose is not limited to patients as safe as food.

Vibration Analysis of Film Winding Core Automatic Supply System Using US Military Standards (미 군사규격을 적용한 권취 코어 자동공급장치의 진동해석)

  • Go, Jeong-Il;Park, Soo-Hyun;Hur, Jang-Wook
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.21 no.4
    • /
    • pp.91-99
    • /
    • 2022
  • By applying METHOD 514.8 of the US military standard MIL-STD-810H, vibration analysis of the winding core automatic feeding device was performed during vehicle transportation. The contact point between the LM guide and main support frame was weak in the vertical axis, transverse axis, and longitudinal axis during the transportation of the automatic winding core feeder vehicle, and the maximum equivalent stress was 236.31 MPa in the longitudinal axis. When random vibration was applied, the safety margin in the longitudinal direction was 0.26, indicating low safety. The safety margin was changed by increasing the damage factor to 0.1. Finally, the safety margin was improved to 3.48 to secure safety. Resonance occurred with a Q factor of 9.34 in the harmonic response to which the RMS value of the ASD data was input, and the vertical axis safety margin was derived as 0.16. When the damping factor was 0.15, the Q factor was 3.37, and resonance was avoided with a safety margin of 6.62.

The Influence of Shoppers' Security Need Sufficiency and Customer Satisfaction on the Quality of Security Services in Large Shopping Centres (대형쇼핑몰 보안서비스품질이 고객안전욕구충족 및 고객이용만족에 미치는 영향)

  • Lee, Jong-Hwan;Kang, Kyoung-Soo
    • Korean Security Journal
    • /
    • no.23
    • /
    • pp.41-63
    • /
    • 2010
  • This study aimed to asses the relationship between shoppers' security need sufficiency and customer satisfaction on the quality of security services in Shopping Mall. This study gathered data from 485 citizen in five shopping centres at KyungKi areas. Collected data was analysed by factor analysis, reliability analysis, path analysis and multiple regression analysis with SPSS WIN 16.0. The results of the study yielded the following four perspectives. First, secure equipment and the service quality of security officers in the shopping malls have a decisive effect on customers psychological stability and crime prevention. Second, they are a strong influence upon customer satisfaction and operational security. Especially, the professionalism of the staff has a marked effect. Third, the service quality of security officers and secure equipment in the malls have an effect on operational security services and efficiency of secure services. Finally, this dissertation showed that the quality of secure equipment services and officers' mild In summary, the conclusion of this study is that secure equipment service, officers' mild manner and professionalism of the security officers affect the customer satisfaction measurement directly. They also affect customer satisfaction through psychological stability and the prevention of crime indirectly. In other words, the good quality of security in the shopping centres affects the using of facilities definitely.

  • PDF

Improved Strong Password Mutual Authentication Protocol to Secure on Replay Attack (재전송 공격에 안전한 개선된 강력한 패스워드 상호인증 프로토콜)

  • Kim, Jun-Sub;Kwak, Jin
    • Journal of Advanced Navigation Technology
    • /
    • v.14 no.3
    • /
    • pp.415-425
    • /
    • 2010
  • In public network, user authentication is important security technology. Especially, password-based authentication method is used the most widely in distributed environments, and there are many authentication methods. Their SPMA protocol indicates vulnerability about problem that NSPA protocol does not offer mutual authentication, and proposed Strong Password Mutual Authentication protocol with mutual authentication. However, SPMA protocol has vulnerability of replay attack. In the paper, we analyzed vulnerability to replay attack of SPMA protocol. And we also proposed Improved Strong Password Mutual Authentication protocol to secure on replay attack with same efficiency.

A Study of Biocompatibility of Acupuncture's Metal Materials - Focused on Biological Character (2) - (침 금속재료에 대한 생체적합성 연구 - 생물학적 특성을 중심으로(2) -)

  • Jung In-Tae;Kang Jung-Won;Baek Yong-Hyeon;Lee Sang-Hoon;Lee Jae-Dong;Choi Do-Young
    • The Journal of Korean Medicine
    • /
    • v.26 no.2 s.62
    • /
    • pp.166-175
    • /
    • 2005
  • Objecitve: To present criteria for acupuncture standardization, which will improve the quality of acupuncture and secure safety, through studies of the biocompatibility of acupuncture needles. Methods: Acupuncture needles distributed in Korea were studied. Acute poisonous tests and pyrogenicity materials tests were executed to study the biocompatibility of acupuncture needles. Results & Conclusions: All 3 brands of acupuncture needles commonly distributed in Korea were found suitable for medical use, through acute poisonous tests and pyrogenicity materials tests. However, the medical instrument standards of the Korea Food and Drug Administration for acupuncture lack criteria concerning acute poisonous tests and pyrogenicity materials tests. The criteria for these tests should be standardized in order to secure the biocompatibility of acupuncture needles.

  • PDF

A Study on the Inference Model of In-use Vehicles Emission Distribution according to the Vehicle Mileage (주행거리별 운행차 배출가스 분포 추정 모델에 관한 연구)

  • 김현우
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.4
    • /
    • pp.85-92
    • /
    • 2002
  • To investigate the safety of the in-use vehicles emission against the tail-pipe emission regulation, in-use vehicles emission trend according to vehicle mileage should be known. But it is impossible to collect all vehicles emission data In order to know that. Therefore, it is necessary to establish a statistically meaningful inference method that can be used generally to estimate in-use vehicles emissions distribution according to the vehicle mileage with relatively less in-use vehicles emission data. To do this, a linear regression model that solved the problems of data normality and common variance of error was studied. As a way that can secure the data normality, In(emission) instead of emission itself was used as a sampled data. And a reciprocal of mileage was suggested as a factor to secure common variance of error. As an example, 36 data of FTP-75 test were handled in this study. As a result, using average value and standard deviation at each mileage which were inferred from a linear regression model, probability density distribution and cumulative distribution of emissions according to the vehicle mileage were obtained and it was possible to predict the deterioration factor through full useful life mileage and also possible to decide whether those in-use vehicles will meet the tail-pipe emission regulations or not.

Study on Implementation Scheme for Integrated PSD Control System of Seoul Metro (서울메트로 PSD 통합관제시스템 구축방안에 대한 연구)

  • Kim, Yong-Hyeop;Hyun, Yong-Sub;Ryoo, Ho-Joong;Kim, Jin-Su
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.1551-1559
    • /
    • 2007
  • Seoul Metro has been constructing the screen doors on the platforms to provide safe and comfort environments. The screen doors of each station are configured so that they can be operated in automatic mode in connection with ATC/ATO through the integrated control panel in the station control room and in manual mode through the control panel of the station control room and crew control panel. These systems have been implemented with different data communication protocols between systems, HMI configuration, and so on due to ordering processes, implementation time and diverse suppliers, and manufactured to be operated within single station. Seoul Metro has been planning to implement the integrated control system to secure seamless train operation and safety and to have a fast response system against emergency situations such as PSD failure and fire, by implementing the system that is able to collectively manage, monitor and control the operation status and equipment conditions of PSD on to the integrated control center. This paper has studied a scheme to reduce the budget for the future facility constructions by standardizing the data format for data communication with the integrated station control panel and using the open standard protocols, in order to secure consistency of operation, system expansion and maintenance with unified and standardized control items.

  • PDF