• Title/Summary/Keyword: Safety Measure

Search Result 1,838, Processing Time 0.026 seconds

Measurements of Dynamic Strain of Structures Using PVDF Films (PVDF 필름을 이용한 구조물의 동적 변형률 측정)

  • Kim, Su-Min;Shin, Sung-Woo;Lee, Jae-Yong;Kim, Nam-Sik
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.6
    • /
    • pp.64-70
    • /
    • 2011
  • In this study, the applicability of PVDF films for measurements of dynamic strain in a structure was investigated. A relationship between the strain and the voltage response of a PVDF film was analytically derived. Free vibration test on a steel cantilever beam was performed and vibration response of the beam was measured both by a convential foil strain gauge and a PVDF film. Strain-voltage relationship obtained from the experiment was compared with the analytic relationship. Good agreement between the analytic and experimental relationships was observed. It was found that a tailored PVDF film can measure the dynamic strain of a structure as accurate as a conventional foil strain gauge.

The Measure of Safety Operation of Train under Abnormal Climate in Conventional line (기존선에서 이상기후 발생시 열차안전운행 확보 방안)

  • Kim, Chi-Tae;Lee, Sung-Uk;Jung, Do-Won;Joo, Chang-Hoon
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.130-137
    • /
    • 2006
  • In these days abnormal climate occurs frequently because of global warming and earthshock. So it is necessary to prepare for the abnormal conditions like gale, rainfall, heavy snow and high temperature. Fortunately, Korea high speed rail(KTX) have a safety climate detection system for the abnormal weather by using CTC. So the safety is guaranteed in most aspect. But in convention line there isn't any alarm system for the abnormal condition and the train runs until the railroad loss occurred. So convention line need additional regulation same as KTX for the abnormal climate and in the near future passenger safety must be protected by new alarm system.

  • PDF

Comparison of Ground Resistance Measurement Value by the Substitute Auxiliary Electrode (대체 보조전극을 이용한 접지저항 측정값 비교)

  • Lee, Snag-Ick;Yoo, Jae-Geun;Jeon, Jeong-Chay;Jeon, Hyun-Jae
    • Proceedings of the KIEE Conference
    • /
    • 2007.04b
    • /
    • pp.85-87
    • /
    • 2007
  • This paper summarize about the auxiliary electrode measured a ground resistance The method to measure a ground resistance is the fall-of-potential method to using an auxiliary electrode. And an auxiliary electrode must be set up on the ground. Today it is so difficult to set up the auxiliary electrode on the ground because of many concrete building and many paved roads. So this paper is regarding of the ground resistance measurement by the substitute auxiliary electrode. It substituted a iron structure around the building, a wire net for auxiliary electrode. This information is confirmed by compared with the measurement value.

  • PDF

FORM-based Structural Reliability Analysis of Dynamical Active Control System (동적능동제어시스템의 FORM기반 구조신뢰성해석)

  • Ok, Seung-Yong
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.1
    • /
    • pp.74-80
    • /
    • 2013
  • This study describes structural reliability analysis of actively-controlled structure for which random vibration analysis is incorporated into the first-order reliability method (FORM) framework. The existing approaches perform the reliability analysis based on the RMS response, whereas the proposed study uses the peak response for the reliability analysis. Therefore, the proposed approach provides us a meaningful performance measure of the active control system, i.e., realistic failure probability. In addition, it can deal with the uncertainties in the system parameters as well as the excitations in single-loop reliability analysis, whereas the conventional random vibration analysis requires double-loop reliability analysis; one is for the system parameters and the other is for stochastic excitations. The effectiveness of the proposed approach is demonstrated through a numerical example where the proposed approach shows fast and accurate reliability (or inversely failure probability) assessment results of the dynamical active control system against random seismic excitations in the presence of parametric uncertainties of the dynamical structural system.

A study on the bridge safety management model using Ubiquitous technology (유비쿼터스 기술을 이용한 교량 안전관리 방안 연구)

  • Jo, Byung-Wan;Kim, Do-Keun;No, Seung-Hyun;Kim, Heoun
    • 한국방재학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.489-492
    • /
    • 2008
  • Nowadays in order to estimate safety diagnosis of bridge, a lot of data like static and dynamic displacement, accelerometer, wind velocity and so on are demanded. When it comes to measure these data, cabled sensor is essential equipment. But cabled sensors have also inefficient factors. From this point of view, considering practical aspects of using these expensive equipments which have been used to examine safety diagnosis, measuring by cabled sensors is restrictive in some respect. Recently to improve theses problems, Wireless sensor system was introduced. But this system can't perform intelligent reaction because database of this system is just based on internet. In this paper, the intelligent bridge safety management model which can be installed easily, measured at all times and dealing intelligently with various situations is developed to improve these problems.

  • PDF

A brief review of national management system in public health and medical aspect (보건의료관점에서 본 국가재난안전관리 체계 및 대책)

  • Kim, Jee-Hee;Lee, Si-Young
    • 한국방재학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.375-376
    • /
    • 2008
  • Recently the increase of natural disaster and man-made disaster, newly emerging infectious diseases and bioterrorism attack changed the world in many aspects. So the Ministry of Health and Welfare and other related agencies are trying to solve the problems with disasters. We discussed these problems in the following eleven categories. (1) emergency medicine (2) communicable disease control, (3) food safety control, (4) public facilities safety, (5) social welfare facilities safety, (6) bioterrorism control, (7) geriatric health care, (8) insurance support, (9) overseas disaster victim support, (10) national organization protection, (11) fire fighter safety in forest fire. Through the reviews on the various kinds of disaster, we proposed the disaster control measure for the near future.

  • PDF

Flame Extinguishing Characteristics of Clean Gaseous Agents and Effects of Additives (가스계 청정소화약제의 소화특성과 첨가제에 따른 영향)

  • Shin, Chang-Sub;Kim, Sung-Min
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.6
    • /
    • pp.95-99
    • /
    • 2008
  • Halon was known as a cause of the ozone layer destruction. In 1987, it was designated as one of the ozone-layer-destroying materials in the Montreal Protocol. Therefore substitutes of Halon agent has been developed including inert gas extinguish system, which is one of the most widely used fire extinguishing system. This study intended to increase the efficiency of inert gas extinguishing agent by using inert gas additives. As IG-541 shows high extinguishing power, the experiment was performed to measure the effects of gaseous additives to it. Cup-burner fire extinguishing apparatus was used with n-Heptane fuel. Among many of pure inert gaseous agents, Helium showed the most excellent extinguishing power. When Helium was added to IG-541, fire extinguishing power was increased and the concentration of oxygen in chimney also risen. By adding Helium to IG-541, the effectiveness of inert gas fire extinguishing system is able to be increased.

Development of System Dynamics Model and Integrated Tool for Safety Culture Diagnosis of a Combined-Cycle Power Plant (복합발전 플랜트 안전문화 진단을 위한 시스템 다이내믹스 모델링 및 통합도구 개발 연구)

  • Choi, Jaewoo;Um, Sungin;Hong, Inki
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.3
    • /
    • pp.70-76
    • /
    • 2017
  • Although various methods have been tried to measure the safety culture of firms, they are limited to derive the qualitative analysis results according to the subjective criteria that are not formalized according to the evaluation method. We developed a questionnaire that can be applied to a combined power plant, quantified the evaluation results using the system dynamics model based on the results, and conducted simulation through various scenarios. And to present the criteria for safety cultural policy.

THE DEVELOPMENT OF A UV FLAME DETECTOR FOR THE AUTOMATIC FIRE SUPPRESSION SYSTEM FOR ENGINE COMPARTMENT FIRES

  • Lim, Sung-Mook;Jung, Ki-Chang;Kim, Eung-Sik;Kim, Hong
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.590-597
    • /
    • 1997
  • In this work, a new type of UV flame detection system was developed. In order to measure the performance of UV flame detector, various kinds of experiments was performed. The results show that the maximum response time of the UV flame detector is 0.2 seconds when the detection distance is one meter The advantages of this system include wide area, high speed response and high sensitivity. After testing the W flame detector in engine compartment it detected fire within 0.09 seconds and extinguished within 5 seconds. Hence, the UV flame detector can be applied in automatic fire suppression system for automobiles.

  • PDF

Food safety regulation based on WTO SPS agreement and the required future work (WTO SPS 협정에 기초한 식품안전 규제와 향후 과제)

  • Cho, Seung Yong;Cho, Sanggoo
    • Food Science and Industry
    • /
    • v.51 no.3
    • /
    • pp.196-208
    • /
    • 2018
  • This paper described the contents of the WTO (world trade organization) SPS (world trade organization) Agreement and trends in the WTO SPS provisions such as equivalence, localization, transparency, and risk assessment. The purpose of the WTO SPS agreement is to promote international trade by preventing arbitrary and unreasonable use of SPS measures, which are the rights of a country for the protection of human health and animal and plant health, and by abolishing the non-tariff barriers. To this end, the requirements for implementing the SPS measures taken by the importing country are restricted to those that can scientifically prove to be inevitable for SPS protection. The major provisions in WTO SPS agreement were elaborated to promote international trades. When trade-restricted SPS measures such as prohibition of imports are made, a scientific basis should be provided. Therefore, it is essential to provide scientific evidence based on risk analysis to protect people's health from potentially harmful imported foods.