• Title/Summary/Keyword: Safety Indicators

Search Result 506, Processing Time 0.029 seconds

Investigation of Key Factors to measure on-site Performance of a Construction firm

  • Lee, Young-Dai;Kim, Jung-Ki;Acharya, Nirmal Kumar
    • Korean Journal of Construction Engineering and Management
    • /
    • v.8 no.6
    • /
    • pp.246-262
    • /
    • 2007
  • The performance of projects has always been an area of interest in the construction industry. Roles of all construction supply chain partners are necessary; however the role of a contractor firm in the construction project is pivotal. So, this research intended to explore a Construction Firm's performance criteria which could measure the level of performance of that firm in an ongoing project. Data was collected from construction professionals working in three principal project participant organizations, namely Owner, Consultant and Contractor. A total of 113 nos. of performance measuring items were sorted from literature review and used to collect data. Statistical tools processed by SPSS program was employed to analyze the data. Out of total 113 items, only 65 nos. of variables were found to be acceptable to every population group of this study. Factor analysis revealed 12 key performance predicting factors (KPPF) with 53 predictive indicators. 12 KPPFS with index weight are: work progress and smoothening (9.3%), change order management and work accuracy (9.1%), business relationship building (8.1%), adequacy of construction work procedure (8.6%), quality performance (8.0%), health and site safety adequacy (8.8%), Innovative contractor (8.0%), adequacy of construction site information (6.8%), compliance with contract plan/specification requirements (8.9%), creditworthiness and financial capability (8.3%), intra-agency relationship and responsiveness (7.0%) and resource management (9.2%). These results could be useful to project management body to evaluate performance of its contractor firm on site as well as the contractor itself to assess own performance and its subcontractors on-site.

A Study on Using U-Service to Strengthen Urban Competitiveness

  • Shin, Jin-Dong;Lee, Jae-Won;Lee, Sang-Hun;Kim, Hyong-Bok
    • Spatial Information Research
    • /
    • v.17 no.4
    • /
    • pp.417-430
    • /
    • 2009
  • This study examined correlations between U-Service for U-City and assessment indicators for urban competitiveness. The results of this study show that U-Service is used as a means of strengthening urban competitiveness in six types of cities, despite the differences in degree of contribution. The proper use of U-Service in Safety & Health City and Vitality (Economy) City has significantly contributed to strengthening the competitiveness of such cities. Of the assessment items for urban competitiveness, common items and Culture City type show that U-Service has not contributed much to strengthening urban competitiveness. The analysis shows that because common items are part of the assessment items for urban policies, these items are not suitable to the character of a U-City that implements U-Service through intelligent physical facilities. On the other hand, U-Service related to the Culture City type is relatively less developed. This study found out that U-Service could be used to reinforce urban competitiveness.

  • PDF

SOH Estimation and Feature Extraction using Principal Component Analysis based on Health Indicator for High Energy Battery Pack (건전성 지표 기반 주성분분석(PCA)을 적용한 고용량 배터리 팩의 열화 인자 추출 방법 및 SOH 진단 기법 연구)

  • Lee, Pyeong-Yeon;Kwon, Sanguk;Kang, Deokhun;Han, Seungyun;Kim, Jonghoon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.5
    • /
    • pp.376-384
    • /
    • 2020
  • An energy storage system is composed of lithium-ion batteries in modern applications. Batteries are regarded as storage devices for renewable and residual energy. The failure of batteries can cause the performance reduction and explosion of battery systems. High maintenance cost is essential when dealing with the problem of battery safety. Therefore an accurate health diagnosis is required to ensure the high reliability of battery systems. A battery pack is a combination of single cells in series and parallel connections. A battery pack has to consider various factors to assess battery health. Battery health involves conventional factors and additional factors, such as cell-to-cell imbalance. For large applications, state-of-health (SOH) can be inaccurate because of the lack of factors that indicate the state of the battery pack. In this study, six characterization factors are proposed for improving the SOH estimation of battery packs. The six proposed characterization factors can be regarded as health indicators (HIs). The six HIs are applied to the principal component analysis (PCA) algorithm. To reflect information regarding capacity, voltage, and temperature, the PCA algorithm extracts new degradation factors by using the six HIs. The new degradation factors are applied to a multiple regression model. Results show the advancement and improvement of SOH estimation.

Patterns of Plasma Fatty Acids in Rat Models with Adenovirus Infection

  • Paik, Man-Jeong;Park, Ki-Ho;Park, Joong-Jean;Kim, Kyoung-Rae;Ahn, Young-Hwan;Shin, Gyu-Tae;Lee, Gwang
    • BMB Reports
    • /
    • v.40 no.1
    • /
    • pp.119-124
    • /
    • 2007
  • Adenoviral vectors are among the most promising vectors available for human gene therapy. However, the use of recombinant adenoviral vectors, including replicationcompetent adenovirus (RCA), raises a variety of safety concerns in relation to the development of new therapies based on gene therapy. To examine how organic compounds change in rat plasma following the injection of adenovirus, $\beta$-galactosidase expressing recombinant adenovirus (designated rAdLacZ) or RCA, we investigated the content of fatty acids (FAs), which are important biochemical indicators in pathological conditions. Pattern recognition analysis on the level of FAs in rat plasma is described for the visual discrimination of adenovirus infection groups from normal controls. Plasma FAs from four control rats (normal group), and from four rats with rAdLacZ infection and six rats with RCA infection (the two abnormal groups), were examined by gas chromatography-mass spectrometry in selected ion monitoring modes as their tert-butyldimethylsilyl derivatives. In total, 20 FAs were positively detected and quantified. The results of the Student's t-test on the normal mean of two abnormal groups, the levels of three FAs (p<0.05) from rAdLacZ group and eleven FAs (p<0.05) from RCA group were significantly different. When star symbol plotting was applied to the group mean values of 20 FAs after normalization to the corresponding normal mean values, the resulting eicosagonal star patterns of the two infected groups were distorted into similar shapes, but were distinguishable from each other. Thus, these approaches will be useful for screening and monitoring of diagnostic markers for the effects of infection following the use of adenoviral vectors in gene therapy.

The Impact of TPM Activities on the Business Performance of Small and Medium Sized Enterprises (TPM활동이 중소기업의 경영성과에 미치는 영향)

  • Lee, Jae-Sik
    • Management & Information Systems Review
    • /
    • v.30 no.4
    • /
    • pp.415-440
    • /
    • 2011
  • Purposes of this paper are to find out the implementation strategy of TPM activities for SMEs through the analysis which examine the relationship between key activity factors and business performance. TPM activity has been playing a important role to strengthen the competitive power of the enterprises through the optimization of equipment management and maintenance. This study has been conducted using the data collected from 124 SMEs propelling TPM activity. By analyses of the questionnaires, empirical results shows that TPM activities has positive effect on business performance. The contribution of this study is that it provides a conceptual framework and empirical evidence of the causal relationship between key activity factors and business performance. The result of this study can be used for selection of the performance measurement indicators for target achievement in TPM activity. And it will contribute for objectivity of activity performance in case of displaying measurement indicator showing the performance of TPM activity.

  • PDF

Developing Measurement System for Key Performance Indicators on Building Construction Projects (건설 프로젝트 효율적 성과관리를 위한 핵심 지표 체계 구축)

  • Cha, Hee-Sung;Kim, Tae-Kyoung
    • Korean Journal of Construction Engineering and Management
    • /
    • v.9 no.4
    • /
    • pp.120-130
    • /
    • 2008
  • In construction industry, project performance should be evaluated in terms of project value objectives, i.e., cost, time, quality, safety, and environment. However, there have been few, if any, systematic approaches in assessing comprehensive performance level which encompasses the whole spectrum of project value objectives. It is non trivial to establish the standardized performance metric system due to the project individualities. This study provides a new approach in assessing the wide variety of project performance types by collecting the real industry project data. In addition, the proposed system has been validated through industry survey on project practitioners. It is concluded that the developed quantitative project performance measurement system would be effectively useful in indicating the level of current status of a particular project and furthermore, to provide a meaningful strategy for the future project in a more sustainable way.

Development of Automated Tools for Data Quality Diagnostics (데이터 품질진단을 위한 자동화도구 개발)

  • Ko, Jae-Hwan;Kim, Dong-Soo;Han, Ki-Joon
    • Journal of Information Technology Services
    • /
    • v.11 no.4
    • /
    • pp.153-170
    • /
    • 2012
  • When companies or institutes manage data, in order to utilize it as useful resources for decision-making, it is essential to offer precise and reliable data. While most small and medium-sized enterprises and public institutes have been investing a great amount of money in management and maintenance of their data systems, the investment in data management has been inadequate. When public institutions establish their data systems, inspection has been constantly carried out on the data systems in order to improve safety and effectiveness. However, their capabilities in improving the quality of data have been insufficient. This study develops an automatic tool to diagnose the quality of data in a way to diagnose the data quality condition of the inspected institute quantitatively at the stage of design and closure by inspecting the data system and proves its practicality by applying the automatic tool to inspection. As a means to diagnose the quality, this study categorizes, in the aspect of quality characteristics, the items that may be improved through diagnosis at the stage of design, the early stage of establishing the data system and the measurement items by the quality index regarding measurable data values at the stage of establishment and operation. The study presents a way of quantitative measurement regarding the data structures and data values by concretizing the measurement items by quality index in a function of the automatic tool program. Also, the practicality of the tool is proved by applying the tool in the inspection field. As a result, the areas which the institute should improve are reported objectively through a complete enumeration survey on the diagnosed items and the indicators for quality improvement are presented quantitatively by presenting the quality condition quantitatively.

Water quality analyses between tap water and treated water by point-of-use water dispenser systems (정수기 공급수인 수돗물과 정수기 통과수의 수질차이 분석)

  • Park, Keun-Young;Park, Ji-Won;Kim, Jae-Hyeok;Na, Yeong;Maeng, Sung-Kyu;Kim, Sung-Pyo;Kweon, Ji-Hyang
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.5
    • /
    • pp.395-404
    • /
    • 2019
  • The point-of-use water dispenser systems are widely used because of convenience in handling and demand for high-quality drinking water. The application has been increased recently in the public places such as department stores, universities and the rest areas in express ways. Improvement of water qualities by the dispenser systems was compared with tap water in this study. The tap water is supplied to the dispenser as the influent of the dispenser system. The twelve dispensers in the public places were used. The five dispensers used reverse osmosis as the main filter and other dispensers used various filters such as ultrafiltration, nanofiltration, and alumina filter. The water quality indicators for sanitation safety, i.e., turbidity and total coliforms, were evaluated. Other water qualities such as pH, residual chlorine, heterotrophic plate count (HPC), and total cell counts were also analyzed. By the point-of-use water dispenser, the turbidity, residual chlorine and pH were decreased and the HPC and total cell counts were increased. The t-test results revealed that the HPC of the tap waters were not significantly different from the treated waters but the total cell counts of the two groups were significantly different. The low pH of the RO filter treatment was also significantly different from the tap waters. This study will contribute to understand the role of the point-of-use water dispenser in improving water quality and to identify key water quality for the proper maintenance of the dispenser systems.

Functional Convergence factor and Usability Evaluation of The Range of Use of The Smart Automatic Urine Disposer (스마트 자동 소변처리기의 기능적 융복합요소와 사용범위의 사용성평가)

  • Kim, Seon-Chil
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.5
    • /
    • pp.31-38
    • /
    • 2021
  • Recently, devices that help the general public's urination activity have been developed, but products that take into account the user's urination habits, device functions, and user accessibility are still insufficient. This study conducted a usability evaluation to find user satisfaction and improvement points of products based on smart automatic urine disposer that have convergence and complex functions such as automatic suction functions. There are 21 indicators used in usability evaluation, and were developed based on safety, operability, and satisfaction. As a result, functional satisfaction was high, but in terms of design, problems to be improved such as handles were presented. Therefore, through this study, it was found that the satisfaction of the automatic urine disposer in terms of performance cannot be representative of the product, and the importance of developing usability evaluation index to find product problems.

An Analysis of Construction Execution Tasks for Successful Residential Mechanical Projects (프로젝트 성공을 위한 효과적인 시공업무 및 영향 분석 - 아파트 설비공사를 중심으로 -)

  • Kang, Sang-Hun;Kim, Dae Young
    • Korean Journal of Construction Engineering and Management
    • /
    • v.20 no.2
    • /
    • pp.60-67
    • /
    • 2019
  • The main purpose of this study is to identify the tasks performed at the construction stage of apartment houses and analyze the major construction tasks that may affect the performance indicators and analyze the impact on project performance. Based on expert opinions through preliminary research, pilot data, construction database, and other research trends, domestic and foreign research trends are divided into five major tasks, and each is divided into process management (P'1 ~ P'6), construction management (C'1 ~ C'5), environmental management (E'1 ~ E'4), quality control (Q'1 ~ Q'5), safety management (S'1 ~ S'5). Subsequently, each major task was subdivided into 24 detailed tasks. An independent t-test was conducted to analyze the impact on cost. We compared the importance of achieving the project goal and identified the construction work of concrete important construction which affects not only the cost but also the schedule performance index for the degree of significance of less than 0.05.