• Title/Summary/Keyword: Safety Door

Search Result 327, Processing Time 0.022 seconds

A Study on On-site Discharge Testing for Carbon Dioxide Fire Extinguishing Systems (이산화탄소 소화설비 현장 방출시험 방법론에 관한 고찰)

  • Park, Jun-Hyun;Kang, Tae-Seok;Kim, Jae-Hwan;Kim, Wee-Kyong
    • Fire Science and Engineering
    • /
    • v.29 no.4
    • /
    • pp.26-32
    • /
    • 2015
  • Carbon dioxide principally extinguishes fires by smothering, but an acceptable amount of extinguishing agent is needed. To assure the performance of carbon dioxide systems in Korea, computer programs certified by NEMA are being applied in system design. But the design errors can occur because the geometry of a model test facility is not the same as that of the actual fire area. Since the discharge rate tends to vary considerably with the flow pattern in a pipe, an on-site discharge test is necessary to ensure the performance of the system, especially with low pressure carbon dioxide. Technical standards for carbon dioxide systems do not give detailed guidelines for discharge tests at present. Based on comparative analysis of standards and practical tests, this paper suggests a methodology for on-site discharge tests.

A Study on the Characteristics of the Current Situation of the Child Care Centers for the Children with Disability in Japan - Focus on the 'Day Service for Children' in Tokyo - (일본 장애아 요육시설의 설치 및 이용현황의 특성에 관한 연구 - 일본 동경권의 '아동 데이서비스'를 중심으로 -)

  • Choi, Hee-Won
    • Korean Institute of Interior Design Journal
    • /
    • v.19 no.6
    • /
    • pp.224-232
    • /
    • 2010
  • This paper aims to identify the characteristics and the current situation of the architectural characteristics, children's characters using facilities, and status of management and utilization by surveying 'Day Service for Children' in Tokyo-do. First, About the status of management and utilization, 'Day Service for Children' is operated by a local government, NPO corporate group and social welfare corporate. There are not big differences of the care program or running hours depending on operating principals but there are differences depending on staff organization, number of children and space constitution. Also, infants ratio at 'Day Service for Children' is high for the purpose of detecting disability early and supporting their development early. They have diverse disabilities but developmental disabilities' ratios high and most children are using both this facility and normal nursery centers together. Samples for proper child care based on status of space constitutions were installing lock, raising door knobs and using softer floor materials which are for children's safety. For the problem of space utilization, most comments were about lack of space which is not enough for teaching and training materials. Therefore, as an example, observation rooms for parents and teachers were sometimes used as storages and it changes teachers' moving direction, staying area and behavior zone. The programs of 'Day Service for Children' are divided to group teaching and private one. It will be the best if they have separate spaces such as group class room, private class room and play room. When they were operated by NPO corporate group or Social welfare corporate, there are many cases that their space was not properly zoned for each activity.

A Numerical Study of Ventilation System Operation for Smoke Control in a Subway Station when a Train under Fire is Approaching (화재열차가 진입하여 정차하는 지하철 역사에서 제연을 위한 환기장치 운전에 대한 수치해석 연구)

  • Lee, Seung-Ho;Hur, Nahm-Keon;Cha, Chul-Hyun;Ryou, Hong-Sun;Kim, Dong-Hyeon;Jang, Yong-Jun
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.136-141
    • /
    • 2009
  • The platform screen door(PSD) is installed in the station of the Seoul Metro 9th line for passengers' safety and comfortable environment of the station. The track way exhaust system(TES) is also operated with PSD to exhaust heat released from train. TES can also be used for the purpose of the heat and smoke control in an emergency case of the carriage fire. When the fire is occurred, operation of TES is switched to the smoke exhaust mode form its normal ventilation mode. In the present study, a subway station of Seoul Metro 9th line is modeled, and a 3-D CFD simulation is performed to investigate effectiveness of designed TES in case of fire. A scenario that a train under fire is arriving the station is simulated for several possible operation modes of the TES using moving mesh technique. As a result, temperature and CO concentration distribution in the station is obtained for each operation modes of TES. The effectiveness of TES operation in case of fire is also discussed.

  • PDF

A Study on the Improvement Direction through the Present Status of Nursing Home - Focus on the Nursing Home in Chungcheongbuk-do - (노인요양시설의 건축현황 및 개선방향에 관한 연구 - 충청북도 노인요양시설을 중심으로 -)

  • Lee, Wan-Geon
    • Korean Institute of Interior Design Journal
    • /
    • v.19 no.3
    • /
    • pp.242-250
    • /
    • 2010
  • Recently, the long-term care insurance for the elderly was carried out according to the elderly is increased rapidly and the formation of sympathy that a nation and society try commonly to share health and welfare promotion of the elderly. The purpose of this study is to analyze the present status of nursing home after that the long-term care insurance is enforced in chungcheongbuk-do and to utilize as basic data. The study limited its survey to those facilities that refer to the Ministry of Health and Welfare data, that had the capacity of more than 50 people. The result are as followings. Firstly, most of the nursing home were located on the outskirts of the city. But it must be constructed in the city center if the recent deinstitutionalization trend is reflected. Secondly, notwithstanding the provisions of the Elderly Welfare Law, if the Livability and amenity are considered, the plan of a single or a twin room is needed. The ondol(溫突) system bedroom for the safety of the elderly had to be planned and for the color planning of a bedroom, a heating, the furniture, the form of a door, corridors, etc. should be partly improved. The fastener in which it is appropriate for the main exit, a stair, an elevator, the lighting device, and etc. is needed and the installation of a wandering path for the dementia patient and etc. is required. Thirdly, most of the dining room arranged on the first floor but it is not nearly used and it used for employee or the other use. Therefore, we have to consider the system in which it can deliver the meal to a bedroom. If the smell of the elderly and etc. is considered, the sufficient height of the floor should be reflected for the ventilation equipment. Lastly, The improvement of the existing law are required.

Comparison of Egress Modeling and Experiments for Joint Flow Rate in the Staircase (피난계단 합류 시 유동률에 대한 피난실험 및 모델링 비교)

  • Hwang, Eun-Kyoung;Woo, Sujin;Kim, Jong-Hoon;Kim, Woon-Hyung
    • Fire Science and Engineering
    • /
    • v.28 no.6
    • /
    • pp.41-46
    • /
    • 2014
  • Junction at the staircase is one of key factors for building egress analysis. The most important factor is the congestion at the door or somewhere connecting from bigger area to smaller one. The other factor is the congestion in the staircase. It happens when people from upper floors meets people from the connecting floor. Especially egress situation at the high-rise building is worse. The simulation of the junction is only described by physical agent algorithms in egress model. For that reason, the description of phenomena will validate with the result of experiment and estimate the gap between modeling and experiment. In this research, the experiment of the junction and the simulation was conducted and validated. The gap between the experiment and the modeling was estimated. The flow rates of modeling were lower than the modeling.

Comparison of Egress Modeling and Experiments for Flow Rate in the Bottleneck (병목현상 시 유동률에 대한 피난실험 및 모델링 비교)

  • Hwang, Eun-Kyoung;Woo, Sujin;Kim, Jong-Hoon;Kim, Woon-Hyung
    • Fire Science and Engineering
    • /
    • v.28 no.6
    • /
    • pp.35-40
    • /
    • 2014
  • Bottleneck occurs as many people crowd into narrow doorway or corridor. Delaying egress time is occurred by bottleneck effect, and it is very important phenomenon on the egress analysis for building fire. An analysis of egress time should includes flow rate for considering bottleneck. Flow rate is numbers of people who pass the narrow gate as door or start point of corridor per unit length and unit time. The flow rate resulted from egress modeling should be approached to the result of experiments. In this study, flow rates from modeling by 'Pathfinder' and experiments was compared. The difference between the result from egress modeling and the one from experiments was verified. The average value of experiments is $4.25N/m{\cdot}s$, and the maximum average value of modeling is $1.55N/m{\cdot}s$.

A Study on the Spatial Composition Characteristics of Elderly Housing facilities in Korea (한국 노인주거시설의 공간계획 특성에 관한 연구)

  • Oh Hye Kyung;Hong Yi Kyung;Him Hyun Jee
    • Journal of Families and Better Life
    • /
    • v.22 no.6 s.72
    • /
    • pp.133-142
    • /
    • 2004
  • The purpose of this study was to investigate the spatial composition characteristics of elderly housing facilities in Korea, in order to refer them in establishing the basic plan for elderly housing in Korea. The case study performed in this study from October 16 to October 31 is based on ten housing facilities for the elderly in KOREA. During the site visits, the interview with the custodians, survey of the space, picture taking and diagram gathering were carried out. The results of this study were as follows; 1. The type of floor plan was classified into ㅁ type, L type, and ㅡ type. And they hadn't an outside space called a garden(courtyard). 2. The kinds of common spaces could be grouped as the space for basic living, for leisure, and for convenient living. Also it was all common that the housing facility had common diningroom laundry room once, and activity room. The type of the common spaces was categorized into three types, the centralized type where the shared space was located at the center of the housing facilities, the distributed type, depending on the degree of separation between common spaces and units, and another each building type. 3. The kinds of units was classified into studio, oneroom, one bedroom and two bedroom. 4. Elevator, safety grab bar, emergency bell, and the door handle of lever or bar type were placed in these facilities.

A Study for the Fire Hazard Evaluation through the Fire Simulation of an Apartment Fire Accident (아파트 화재 사례 전산모사를 통한 화재위험성 평가에 관한 연구)

  • Jeon, Heung-Kyun;Choi, Young-Sang;Choo, Hong-Lok
    • Fire Science and Engineering
    • /
    • v.24 no.4
    • /
    • pp.69-78
    • /
    • 2010
  • In this study, Fire Hazards were evaluated through computer simulation using FDS program for an apartment fire accident. The results of fire simulation showed that the maximum heat release rate in the case of no sprinklers activation was 7,700 kW which was about 16 times of that in the case of sprinklers activation, 497 kW and there was a very high fire hazard due to the backdraft phenomenon when the door of fire room was forced to open. Regarding the hazard time of fire room temperature and detection time of detectors, available evacuation time was 32.5 seconds of minimum to 53.5 seconds of maximum. In the case of sprinklers activation, fire hazard in the apartment was showed to be very low due to the fire control by the spray cooling of sprinklers. This study shows that what a important function for fire safety is the activations of fire sprinkler system and emergency alarm system and what a large loss can cause if these systems don’t activate in fire accidents.

Smart Outlet System for Single-person Household based on IoT (Internet of Things) (사물 인터넷 기반의 1인 가구를 위한 스마트 콘센트 시스템)

  • Kim, Hye-Suk;Park, Byeong-Ju;Cho, Young-Ju
    • Journal of Digital Contents Society
    • /
    • v.18 no.5
    • /
    • pp.895-904
    • /
    • 2017
  • In this paper, we propose an IoT based smart outlet system for one-person household with electric safety, electric energy consumption management and transmission of messages to the reserved contacts by connecting the emergency network. The proposed smart outlet system is implemented by parsing packet data and protocol between server, module, application and WiFi AP receiver. The WiFi AP built for communication can be used not only for the outlet but also for the gas barrier, the door lock and the like. In addition, the proposed method can provide the remote monitoring function by receiving the amount of power of the receptacle received through the AC current sensor (SCT-013) in real time. The smart outlet system is expected to be capable of automatically shutting off the power in case of emergency through automatic power use analysis in addition to the standby power cutoff function.

A Study of Successful Factor on PSD Application Technique for Manual Operation Mode(ATS) (수동운전(ATS)구간에서 PSD 적용 기술의 성공적 요인 분석연구)

  • Son, Yeong-Jin;Park, Keun-Soo;Min, Kyung-Yun
    • Journal of the Korean Society for Railway
    • /
    • v.10 no.1 s.38
    • /
    • pp.57-66
    • /
    • 2007
  • 1974. 8. 15 SeoulMetro, beginning with the first electric railway established at six cities, so it is managing mass transportation of traffic. Especially, in case of seoul, It is managing that from one to eight lines, 286.9km, 265 stations have installed and now it is carrying about 5.5million of passengers everyday, and 2,000million passengers a year. So accident is increasing from the station every year. For this measure, SeoulMetro prepares safety fence for passengers crash but, as suicides or people who watch the accident took place, for at the bottom of passengers crash protection, PSD installing is needed. Even though, PSD is managing ATO section but, in controlling SeoulMetro, one to four lines sections are (ATS, ATC)section. Between as ATS, ATC section, ATO section, subway gate and PSD must have opened and crossed always at the time. And the interlock control corrosion protection gate, managing skills with installation, method, using in history, apply to 10rail cars one train sets, and maximum applying 2224% sections of passengers congested that consideration is to be needed. So 2004, SeoulMetro improved technology and basie design of PSD at ATS section. Based on this, from 2005.4 to 2006.6, using subway 2lines per 12stations set the model installation(full type 11stations, half type 1station) After installing in case of success, it is going about to suggest that effective analysis and hereafter subject.