A Study on Required Safe Egress Time (RSET) Comparison and Error Calculation in Relation to Fire Room Range Set Conditions of Performance Based Fire Safety Designers (성능위주설계자들의 화재실 범위 설정 방식에 따른 소요피난안전시간(RSET) 비교 및 오차산정에 관한 연구)

  • Baek, Sona;Choi, Jun-Ho;Hong, Won-Hwa;Jung, Jong-Jin
    • Fire Science and Engineering
    • /
    • v.30 no.3
    • /
    • pp.73-78
    • /
    • 2016
  • The Installation, Maintence, and Safety Control of Fire-fighting Systems Act of South Korea regulates that over 30-storey high-rise buildings including underground spaces should vitally perform the Performance-based Design to minimize property damage and personal injury as a fire risk assessment in advance. Therefore a PBD designer such as a fire safety professional engineer evaluate occupant's life safety by a scientific methodology. In order to evaluate the life safety, fire safety designers calculate the Required Safety Egress Time (RSET) which does not have the legal criteria regarding the standard method of calculation yet. So this way has been showing different results depending upon the designer's choice, knowledges and experiences. In this study, RSET calculation methods by six designers respectively were analysed from the thirteen reports of real performance based design projects conducted in Busan for a last five years. In particular, the Response Time calculation methods which have the most powerful effect for figuring the RSET are compared with the other designer's to deduce an error value.

Video-assisted Thoracoscopic Surgery in Posttraumatic Localized Clotted Hemothorax (외상 후 국소적으로 응고된 혈흉의 비디오흉강경수술)

  • 이정희;김정중;이석기;임진수;최형호
    • Journal of Chest Surgery
    • /
    • v.37 no.12
    • /
    • pp.987-991
    • /
    • 2004
  • Background: Inadequate drainage of traumatic hemothoraces may result in prolonged hospitalization and complication such as empyema, fibrothorax and pleural calcification. This needs to be the placement of a tube thorascostomy which is efficacious in more than 80% of cases. Other cases require surgical treatment. Material and Method: From March 2002 to February 2003, there were 123 patients who was done closed thorascostomy in traumatic hemothorax. 10 patients (group I) were undergone early retained clot evacuation with video assisted thoracoscopic surgery, but 5 patients (group II) who developed a localized hematoma or empyema were operated. Male were more than female and mean average was similar in both group. The most common cause of injury was traffic accidents and frequently combined lesions were a abdomen. Result: Interval from injury and operation, mean operation time, duration of tube drainage and hospital stay in group I were shorter than group II (p<0.05). Operation-related complication and recurrence of fluid collection within follow up period (17.8$\pm$3.8 months) in group I were none, but in group II (21.5$\pm$5.3 months) were 2 cases. Conclusion: Video assisted thoracoscopic surgery can be utilized as an effective and safe method for the removal of retained clotted hemothorax within 7 days.

A Study on Countermeasures between Central and Local Governments for Earthquake Disaster Management of Pohang, Korea (우리나라 포항지진 재난관리에 대한 중앙·지방정부 간 대책 방안 연구)

  • La, Hong Woo
    • Journal of Korean Society of Disaster and Security
    • /
    • v.12 no.3
    • /
    • pp.25-34
    • /
    • 2019
  • Modern disasters prevent accidents in advance and recover after accidents are very important. Our government's current response to these accidents is not appropriate. As for disaster management so far, it has been the center of disaster response and recovery efforts, and has been led by the government against it. The reality is that most private organizations and agencies have only subsidized government disaster management agencies. Korea is no longer a safe zone for earthquakes. Now for the establishment of effective disaster management system for earthquakes in the diagnosis is very urgent and the problems of the operational disaster management, which the problems of the nation.Policies to improve academic efforts to seek alternative proposal is also at a time when volume can be said to be very big need to mine. This study from 2016 to 2019, about the earthquake that took place between National Statistical Office, based on analysis of data to. First of all, research 1: What was the government's plan on Pohang earthquake? The results showed that the residents' evacuation of Pohang was important in the Pohang earthquake, but for the sake of students' safety, they were directly assigned to the test site to cope with the emergency situation. Therefore, the research and analysis shows that the nation should continue to think about the causes and responses of the damage at the disaster site and strive to develop technologies and methods to minimize the damage.

A study on possibility of soft target terrorism by ISIS in South Korea (자국내 IS테러단체에 의한 소프트타깃 테러발생 가능성에 대한 연구)

  • Oh, Sei-Youen;Yun, Gyeong-Hui
    • Korean Security Journal
    • /
    • no.47
    • /
    • pp.85-117
    • /
    • 2016
  • These days, ISIS terrorists have been expanding not only to european countries, but also to asian countries so South Korea is no longer safe from terrorists' attacks. Especially, 'soft target terrorism' makes many people maximizing fear of terrorism because it is caused by small groups - those who are armed with small arms and light weapons - and they are able to carry out hit and run attacks on civilian targets. It poses even more dangerous to kill massively. That is why November 2015 Paris attacks and January 2016 Jakarta attacks killed and injured many people because of 'soft target terrorism.' Therefore, the South Korea has also recognized the seriousness of terrorism by ISIS. The study has shown the precautionary measures about 'soft target terrorism' and how to defend against 'soft target terrorism' by looking through overseas examples. It is for the possibilities of 'soft terrorism' in South Korea because of the expansion of ISIS. As a result, 'soft target terrorism', caused by ISIS, could happen in South Korea. The counterplan is as in the following. First of all, 'soft target terrorism', which is collaborated with ISIS and domestic terrorists, could be caused by negative awareness of foreign residents and xenophobia so the public should change stereotypes about the foreign residents and there should be legislation about racial discrimination enacted by parliament and the government must practice the law. Second, the Korean anti-terrorism laws should be modified to minimize violations of human rights, related to the Korean citizens' personal information, and to stop the concentration of power into the hands of one law enforcement. Third, the government has to develop and to initiate the refuge&evacuation simulation, which prepares for 'soft target terrorism' and minimizes the damages if terrorists attack hot spots like central commercial areas or event halls.

  • PDF

Prediction of Water Level at Downstream Site by Using Water Level Data at Upstream Gaging Station (상류 수위관측소 자료를 활용한 하류 지점 수위 예측)

  • Hong, Won Pyo;Song, Chang Geun
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.2
    • /
    • pp.28-33
    • /
    • 2020
  • Recently, the overseas construction market has been actively promoted for about 10 years, and overseas dam construction has been continuously performed. For the economic and safe construction of the dam, it is important to prepare the main dam construction plan considering the design frequency of the diversion tunnel and the cofferdam. In this respect, the prediction of river level during the rainy season is significant. Since most of the overseas dam construction sites are located in areas with poor infrastructure, the most efficient and economic method to predict the water level in dam construction is to use the upstream water level. In this study, a linear regression model, which is one of the simplest statistical methods, was proposed and examined to predict the downstream level from the upstream level. The Pyeongchang River basin, which has the characteristics of the upper stream (mountain stream), was selected as the target site and the observed water level in Pyeongchang and Panwoon gaging station were used. A regression equation was developed using the water level data set from August 22th to 27th, 2017, and its applicability was tested using the water level data set from August 28th to September 1st, 2018. The dependent variable was selected as the "level difference between two stations," and the independent variable was selected as "the level of water level in Pyeongchang station two hours ago" and the "water level change rate in Pyeongchang station (m/hr)". In addition, the accuracy of the developed equation was checked by using the regression statistics of Root Mean Square Error (RMSE), Adjusted Coefficient of Determination (ACD), and Nach Sutcliffe efficiency Coefficient (NSEC). As a result, the statistical value of the linear regression model was very high, so the downstream water level prediction using the upstream water level was examined in a highly reliable way. In addition, the results of the application of the water level change rate (m/hr) to the regression equation show that although the increase of the statistical value is not large, it is effective to reduce the water level error in the rapid level rise section. Accordingly, this is a significant advantage in estimating the evacuation water level during main dam construction to secure safety in construction site.

Flow and smoke behavior of a longitudinal ventilation tunnel with various velocities using computational fluid dynamics (팬의 운전조건에 따른 종류식환기터널 내의 연기거동에 관한 전산유체역학연구)

  • Lee, J.H.;Kwon, Y.J.;Kim, D.E.
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.16 no.1
    • /
    • pp.105-115
    • /
    • 2014
  • A numerical analysis on the smoke behavior and evacuee safety has been performed with computational fluid dynamics. The purpose of this study is to build computational processes for an evacuation and prevention of a fire disaster of a 3 km-length tunnel in Korea. To save computational cost, 1.5 km of the tunnel that can include a few cross-passing tunnels is considered. We are going to assess the fire safety in a road tunnel according to the smoke level, which consists of the smoke density and the height from the floor. The smoke density is obtained in detail from three-dimensional unsteady CFD analysis. To obtain proper temperature distributions on the tunnel wall, one-dimensional conduction equation is considered instead of an adiabatic wall boundary or a constant heat flux. The tunnel considered in this study equips the cross passing tunnels for evacuees every 250 m. The distance is critical in both safety and economy. The more cross passing tunnels, the more safe but the more expensive. Three different jet fan operations can be considered in this study; under- and over-critical velocities for normal traffic condition and 0-velocoty operation for the traffic congestion. The SE (smoke environment) level maps show a smoke environment and an evacuating behavior every moment.

Clinical Feasibility of Video-assisted Thoracic Surgery for Thoracic Trauma (흉부외상 치료에서의 비디오 흉강경 수술의 유용성)

  • Kang, Do-Kyun;Kim, Hyeong-Ryul;Kim, Yong-Hee;Kim, Dong-Kwan;Park, Seung-Il
    • Journal of Trauma and Injury
    • /
    • v.23 no.2
    • /
    • pp.170-174
    • /
    • 2010
  • Purpose: As techniques and instruments for video-assisted thoracic surgery (VATS) have been evolving, attempts to perform VATS for chest trauma have been increasing. Several studies have demonstrated the feasibility and safety of VATS for thoracic trauma. We reviewed our experience to evaluate the clinical feasibility and safety of VATS for thoracic trauma. Methods: Fifty-two patients underwent thoracic surgery for chest trauma in Asan Medical Center from January 1990 to December 2009. VATS was performed in 21 patients who showed stable vital signs. We reviewed retrospectively the medical records of those patients to investigate the results of VATS for thoracic trauma. Results: Thoracic exploration for chest trauma was performed in 52 patients. There were 46 males (88.5%) and 6 females (11.5%). The median age was 46.0 years (range: 11~81 years). There were 39 blunt and 13 penetrating traumas. A standard posterolateral thoracotomy was performed in 31 patients, and VATS was tried in 21 patients. We performed successful VATS in 13 patients; 11 males (84.5%) and 2 females (15.5%) with a median age of 46.0 years (range: 24~75 years). The indication of VATS was persistent intrathoracic hemorrhage in 10 patients and clotted hemothorax in 3 patients. There were no complications, but there were two mortalities due to multiple organ failure after massive transfusion. In 8 patients, VATS was converted to a standard posterolateral thoracotomy for several reasons. The reason was inadequate visualization for bleeding control or evacuation of the hematoma in 5 patients. In 3 patients, VATS was performed to evaluate diaphragmatic injury. After the diaphragmatic injury had been confirmed, a standard posterolateral thoracotomy was performed to repair the diaphragm. Conclusion: VATS should be safe and efficient method for diagnostic evaluation and surgical management of stable patients with thoracic trauma.

Antibacterial Activity of $NANOVER^{TM}$ Against Oral Malodor Generating Microorganisms 1. The Effect of Nanosilver on Growth of Oral Malodor Generating Microorganisms (구취유발세균에 대한 $NANOVER^{TM}$의 항균효과 검사 1. Nanosilver가 구취 세균의 증식에 미치는 영향)

  • Jung, Young-Hee;Mo, Hye-Won;Jeong, Ji-Suk;Choi, Kyung-Ho;Choi, Jae-Kap;Hur, Yun-Kyung;Lee, Sang-Heun
    • Journal of Oral Medicine and Pain
    • /
    • v.34 no.1
    • /
    • pp.39-48
    • /
    • 2009
  • Recently there is much interest in the antibacterial activity of nano-sized silver particle (nanosilver) since silver is known to be safe and effective as disinfectant for a long time. Oral malodor is considered to originate in the oral cavity primarily as a result of production of malodorous compounds by oral bacteria. Major compounds responsible for oral malodor are volatile sulfur compounds, which is thought to be generated by the G(-) anaerobic bacteria found normally in the oral cavity, especially on the dorsum of the tongue. The purposes of this study were to investigate the effect of nanosilver on growth of oral malodor generating microorganisms, including Fusobacterium nucleatum, Prevotella melaninogenica, Klebsiella pneumonia, and to determine the optimal culture condition of them. The results were as follows: 1. The optimal culture condition for P. melaninogenica was vacuum culture using desiccator after evacuation of air by vacuum pump in chopped beef meat media. 2. The growth of K. pneumonia was temporarily inhibited by nanosilver (5 ppm and 10 ppm). 3. The morphological alteration and cell damage caused by nanosilver were observed in K. pneumonia.

Guidelines for Free-Hand Aspiration(FHA) of Putaminal Hemorrhage (피각부 자발성 뇌내출혈의 혈종흡입술을 위한 지표)

  • Yim, Sin Gil;Oh, Min Suk;Lim, Jun Seob;Kang, Myung Gi;Kwak, Yeon Sang;Park, Seung Gyu;Song, Gyung Bae;Kim, Han Yung
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.sup2
    • /
    • pp.294-299
    • /
    • 2001
  • Objectives : CT-guided stereotactic evacuation for spontaneous intracerebral hemorrhage can minimize the brain damage and can be performed safely and simply under local anesthesia. But that procedure is time consuming and has a risk of rebleeding because of the stress during head pin fixation. So authors describe easy and precise guidelines for FHA of putaminal hemorrhage without stereotactic instrument. Methods and Materials : We analyzed the data of 298 patients who underwent CT-guided stereotactic aspiration of putaminal hematoma in our hospital between January 1990 and December 2000. We divided the patients into three groups according to the location of hematoma : anterior portion, middle portion and posterior portion of putamen. Total number of catheters inserted into the hematoma were 345 and there were with regard to the direction and depth of catheters. Results : Proposed guidelines of catheter insertion to putaminal hemorrhage in our institution. 1) hematoma at the anterior portion of putamen ; Direction of catheter was the midpupillary line of the eye and the point intersecting a line drawn from the burr hole to a point between external auditory meatus(EOM) and 1cm posterior to EOM. Depth of catheter was 6-6.5cm. 2) hematoma at the middle portion of putamen ; Direction of catheter was the midpupillary line of the the eye and the point intersecting a line drawn from the burr hole to a point between 1cm and 2cm posterior to EOM. Depth of catheter was 6.5-7cm. 3) hematoma at the posterior portion of putamen ; Direction of catheter was 15 degree laterally from the midpupillary line of the eye and the point intersecting a line drawn from the burr hole to a point between 2cm and 3cm posterior to EOM. Depth of catheter was 7-7.5cm. We have performed FHA of putaminal hemorrhage in 48 cases according to this guideline. All catheter were inserted exactly at the center of hematoma and average operation time was about 30 minutes. Conclusion : Our proposed guidelines for putaminal hemorrhage are considered to be safe and simple method with similar accuracy and rapid decompression compared with traditional stereotactic method. Main advantages of this technique were unnecessity of stereotactic frame application and less time requirement for hematoma removal.

  • PDF

A study on the smoke control performance of the damper exhaust system at FCEV fire in tunnel for small vehicles (소형차 전용터널 내 수소연료전지차 화재시 집중배기방식의 제연성능에 관한 연구)

  • Hong, Seo-Hee;Baek, Doo-San
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.24 no.6
    • /
    • pp.745-756
    • /
    • 2022
  • The road tunnel is a semi-closed space that is blocked on all sides except the entrance and exit, and in the event of a fire, the smoke of the fire spreads longitudinally due to heat buoyancy caused by the fire and air currents that always exist in the tunnel. To solve this problem, smoke removal facilities are installed in road tunnels to secure a safe evacuation environment by controlling the direction of movement of smoke or directly smoking at fire points. In urban areas, the service level of urban roads decreases due to the increase in traffic due to the increase in population, and as a solution, the construction of underground roads in urban areas is increasing. When a fire occurs during hydrogen leakage through TPRD of a hydrogen fuel cell vehicle (FCEV), the fire intensity depends on the amount of leakage, and the maximum fire intensity depends on the orifice diameter of the TPRD. Considering the TPRD orifice diameter of 1.8 mm, this study analyzed the diffusion distance of fire smoke according to the wind speed of the roadway and the opening interval of the large exhaust port when the maximum fire intensity was 15 MW. As a result, it was analyzed that air flow in the tunnel could be controlled if the wind speed of the road in the tunnel was less than 1.25 m/s, and smoke could be controlled within 200 m from the fire if the damper interval was 50 m and 100 m.