• Title/Summary/Keyword: Safe Sample Screening

Search Result 6, Processing Time 0.022 seconds

Re-SSS: Rebalancing Imbalanced Data Using Safe Sample Screening

  • Shi, Hongbo;Chen, Xin;Guo, Min
    • Journal of Information Processing Systems
    • /
    • v.17 no.1
    • /
    • pp.89-106
    • /
    • 2021
  • Different samples can have different effects on learning support vector machine (SVM) classifiers. To rebalance an imbalanced dataset, it is reasonable to reduce non-informative samples and add informative samples for learning classifiers. Safe sample screening can identify a part of non-informative samples and retain informative samples. This study developed a resampling algorithm for Rebalancing imbalanced data using Safe Sample Screening (Re-SSS), which is composed of selecting Informative Samples (Re-SSS-IS) and rebalancing via a Weighted SMOTE (Re-SSS-WSMOTE). The Re-SSS-IS selects informative samples from the majority class, and determines a suitable regularization parameter for SVM, while the Re-SSS-WSMOTE generates informative minority samples. Both Re-SSS-IS and Re-SSS-WSMOTE are based on safe sampling screening. The experimental results show that Re-SSS can effectively improve the classification performance of imbalanced classification problems.

Screening Methods for the Identification of Irradiated Foods

  • Shahbaz, Hafiz Muhammad;Ahn, Jae-Jun;Akram, Kashif;Kwon, Joong-Ho
    • Current Research on Agriculture and Life Sciences
    • /
    • v.31 no.1
    • /
    • pp.1-10
    • /
    • 2013
  • The exposure of food to ionizing radiation has been recognized as a safe and effective mode of food preservation in more than 55 countries. The benefits include eradication of insect pests, inactivation of food pathogens, extension of shelf-life, and improvement in food hygiene. Regulatory authorities around the world have emphasized the implementation of various national and international regulations to facilitate trade and development of consumers' confidence in purchasing irradiated foods. Therefore, the need for reliable irradiation detection methods has increased to enforce these regulations. At present, a number of promising analytical approaches have been developed and evaluated. Moreover, about 10 European Standards have been adopted as General CODEX Alimentarius methods for the detection of irradiated foodstuffs. However, most of these methods demand relatively expensive equipment and prolonged sample preparation. Therefore, simple and cost-effective approaches would be advantageous for rapid screening of foodstuffs. The suspected samples need to be analyzed further with more validated techniques to confirm the screening results. In this review, existing screening methods (i.e. physical, chemical, and biological) for the identification of irradiated foods have been outlined along with their principles, scopes and limitations.

  • PDF

A Study on a space utilization plan for screening clinic in public health center by means of the prevention of respiratory infectious disease - Focused on a negative pressured tuberculosis exam room (호흡기 감염병 예방을 위한 보건소 상시 선별진료소 활용방안 연구 - 음압 결핵 검진실을 중심으로)

  • Yoon, Hyung Jin;Han, Su Ha
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.27 no.4
    • /
    • pp.51-60
    • /
    • 2021
  • Purpose: Tuberculosis(TB) care unit in public health center should be carefully considered to be re-designed as an infection safety environment for both patient and healthcare workers. So, for the enhancement, this study analyses the facility requirements for co-using the screening clinic as a TB and other respiratory disease care unit. Methods: Not only screening clinic facility guidelines from "A Study for Standard Triage Design and Construction Document" but also the guidelines of TB care and related medical facility are reviewed; KDCA, CDC, ECDC and WHO as a TB care, and FGI and NHS for facility. The facility requirements are summarized space, approach, and mechanical requirement in order. By comparing the summary and screening clinic facility guidelines, supplementations are proposed for TB care unit setting. Results: The result of this study shows that both the space program and mechanical requirement of the screening clinic and that of TB care unit are almost identical and could be share, which include direct airflow or negative air pressure in an exam room. To increase functional and economical efficiency, however, it is necessary to consider a multi-functional negative pressured room, So care process may be re-designed based on a room type; face-to-face room or glass wall inbetween. Implications: The facility guidelines for TB care unit of a public health center should be developed to build a safe environment for infection control by reflecting its medical plan and budget.

Predictors of Cancer Awareness among Older Adult Individuals in Jordan

  • Ahmad, Muayyad M.;Al-Gamal, Ekhlas
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.24
    • /
    • pp.10927-10932
    • /
    • 2015
  • Background: Older age is associated with an increase in the incidence of cancer cases. Diagnosis and treatment of cancer in older adults can be stressful because of health decline related to age, comorbidities and inadequate treatment for pain and other symptoms of the disease. This survey is one of the unique studies in Jordan and in the Arab world that aimed at exploring the predictors of older adult individuals awareness towards cancer. Materials and Methods: A stratified random sampling technique was followed to reach a representative sample of 753 participants. The questionnaire of the study consisted of parts regarding demographic variables, awareness about screening tests, and signs and symptoms of cancer. In addition, specific questions related to factors linked to cancer were included. Cross-sectional design was adopted with face-to-face interviews at the interviewees' households. Results: The mean age of the participants was about 63 years; around 44% of them are above the age of 65 years. 'Being convinced that having no health problem makes the individual feel safe and not at risk of getting cancer' was the major reason for not doing a routine health check-up. Conclusions: The low levels of awareness about cancer, as well as the low use of the screening methods were crucial outcomes of this study. Thus, raising the awareness among health care providers and policy makers in the country about older adults' perception of cancer is a high priority.

Observation of Micromorphological Characteristics of Acupuncture Needle Tip Using SEM (주사전자현미경(SEM)을 이용한 일회용침 끝의 미세 형태에 대한 관찰)

  • 장인수;박종배;송범용;이창현
    • The Journal of Korean Medicine
    • /
    • v.23 no.4
    • /
    • pp.27-31
    • /
    • 2002
  • Background and Purpose: There has been little study about the quality of acupuncture needle tips. In order to ensure safe acupuncture treatment, high quality of needle tips is essential. Therefore, we investigated the current condition of the tips of the acupuncture needles on the market. Methods: We selected needles made by 6 companies in Korea, one company each in Japan, the USA and China, and observed the tip of each needle using a scanning electron microscope. Results and Discussion: We found that needles had several defects such as scratch marks on the surface, metallic scuff, lumps and irregularities of the needle tips, stubbed or malformed tips, tips of point off-center, and peeled off coated tips. There were more faulty ones than good ones. Further, better-designed study with a bigger sample size is warranted.

  • PDF

Evaluation of Rapid Immunochromatographic Assay Kit for HBsAg-Screening Using Whole Blood

  • Shin, Hyeong-Soon;Heo, Tae-Ryeon
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.5 no.5
    • /
    • pp.362-365
    • /
    • 2000
  • A rapid immunochromatographic assay kit using whole blood to screen hepatitis B surface antigen was developed and evaluated by using sera from 240 patients. The reference diagnosis was based on the results obtained with GENEDIA Anti-HBs Rapid kit which is very similar to the above kit except for the use of serum. The test demonstrated a good correlation with the reference immunochromatographic assay kit, that is, the sensitivity and the specificity of the kit was 100%, respectively. The rapid test kit using whole blood should be more convenient and useful for the diagnosis of hepatitis B virus because the kit does not need machines and time to prepare serum. In addition, this kit is safe from inadvertent infection during sample treatment because the blood is sterilized with hydrogen peroxide, eliminates the procedure required to prepare serum and reduces the possibility of exposure to infectious agents.

  • PDF