• 제목/요약/키워드: SV-8

검색결과 314건 처리시간 0.038초

Low-Tube-Voltage CT Urography Using Low-Concentration-Iodine Contrast Media and Iterative Reconstruction: A Multi-Institutional Randomized Controlled Trial for Comparison with Conventional CT Urography

  • Kim, Sang Youn;Cho, Jeong Yeon;Lee, Joongyub;Hwang, Sung Il;Moon, Min Hoan;Lee, Eun Ju;Hong, Seong Sook;Kim, Chan Kyo;Kim, Kyeong Ah;Park, Sung Bin;Sung, Deuk Jae;Kim, Yongsoo;Kim, You Me;Jung, Sung Il;Rha, Sung Eun;Kim, Dong Won;Lee, Hyun;Shim, Youngsup;Hwang, Inpyeong;Woo, Sungmin;Choi, Hyuck Jae
    • Korean Journal of Radiology
    • /
    • 제19권6호
    • /
    • pp.1119-1129
    • /
    • 2018
  • Objective: To compare the image quality of low-tube-voltage and low-iodine-concentration-contrast-medium (LVLC) computed tomography urography (CTU) with iterative reconstruction (IR) with that of conventional CTU. Materials and Methods: This prospective, multi-institutional, randomized controlled trial was performed at 16 hospitals using CT scanners from various vendors. Patients were randomly assigned to the following groups: 1) the LVLC-CTU (80 kVp and 240 mgI/mL) with IR group and 2) the conventional CTU (120 kVp and 350 mgI/mL) with filtered-back projection group. The overall diagnostic acceptability, sharpness, and noise were assessed. Additionally, the mean attenuation, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and figure of merit (FOM) in the urinary tract were evaluated. Results: The study included 299 patients (LVLC-CTU group: 150 patients; conventional CTU group: 149 patients). The LVLC-CTU group had a significantly lower effective radiation dose ($5.73{\pm}4.04$ vs. $8.43{\pm}4.38mSv$) compared to the conventional CTU group. LVLC-CTU showed at least standard diagnostic acceptability (score ${\geq}3$), but it was non-inferior when compared to conventional CTU. The mean attenuation value, mean SNR, CNR, and FOM in all pre-defined segments of the urinary tract were significantly higher in the LVLC-CTU group than in the conventional CTU group. Conclusion: The diagnostic acceptability and quantitative image quality of LVLC-CTU with IR are not inferior to those of conventional CTU. Additionally, LVLC-CTU with IR is beneficial because both radiation exposure and total iodine load are reduced.

Support Vector Machine과 상태공간모형을 이용한 단변량 수문 시계열의 동역학적 비선형 예측모형 (Dynamic Nonlinear Prediction Model of Univariate Hydrologic Time Series Using the Support Vector Machine and State-Space Model)

  • 권현한;문영일
    • 대한토목학회논문집
    • /
    • 제26권3B호
    • /
    • pp.279-289
    • /
    • 2006
  • 최근에 수문시계열로부터 저차원의 비선형 거동을 재구성하고자 하는 연구가 활발히 진행되고 있다. 이러한 관점에서 본 연구에서는 Support Vector Machine(SVM)을 이용하여 우수한 상태-공간 재구성 능력을 갖는 비선형 예측모형을 구성하여 Great Salt Lake(GSL) Volume에 적용하였다. SVM은 Kernel 함수로부터 유도된 고차원의 특성공간 안에서 선형함수의 가상공간을 이용하는 Machine Learning 방법론이다. 또한 SVM은 훈련자료로부터 얻어지는 평균제곱오차가 아닌 일반화된 오차를 최소화함으로써 상대적으로 기존 방법에 비해 적은 수의 매개변수와 과적합(over fitting)을 피하면서 비선형 함수의 최적화가 가능하다. 본 연구에서 제시한 SVM 회귀분석의 적용성은 미국의 GSL의 2주 간격 Volume을 대상으로 검토하였다. SVM을 이용한 비선형 예측모형은 GSL Volume의 2주(1-Step), 8주(4-Step)와 반복예측(Iterated Prediction, 121-Step)까지 적용되었다. 본 연구에서는 극치사상 즉, 급격한 감소 및 증가 구간을 예측하는데 있어서 훈련구간과 예측구간을 구분하여 모형의 신뢰성을 평가하였다. 예측결과SVM은 훈련자료로부터 적은 수의 관측치를 이용하여 동역학적 거동을 추출할 수 있었으며 실제 관측자료와 거의 유사한 예측이 가능함을 통계적 지표로 확인할 수 있었다. 따라서 비선형 수문시계열의 단기 예측을 위한 모형으로 적용이 가능할 것으로 판단된다.

Accurate Measurement of Agatston Score Using kVp-Independent Reconstruction Algorithm for Ultra-High-Pitch Sn150 kVp CT

  • Xi Hu;Xinwei Tao;Yueqiao Zhang;Zhongfeng Niu;Yong Zhang;Thomas Allmendinger;Yu Kuang;Bin Chen
    • Korean Journal of Radiology
    • /
    • 제22권11호
    • /
    • pp.1777-1785
    • /
    • 2021
  • Objective: To investigate the accuracy of the Agatston score obtained with the ultra-high-pitch (UHP) acquisition mode using tin-filter spectral shaping (Sn150 kVp) and a kVp-independent reconstruction algorithm to reduce the radiation dose. Materials and Methods: This prospective study included 114 patients (mean ± standard deviation, 60.3 ± 9.8 years; 74 male) who underwent a standard 120 kVp scan and an additional UHP Sn150 kVp scan for coronary artery calcification scoring (CACS). These two datasets were reconstructed using a standard reconstruction algorithm (120 kVp + Qr36d, protocol A; Sn150 kVp + Qr36d, protocol B). In addition, the Sn150 kVp dataset was reconstructed using a kVp-independent reconstruction algorithm (Sn150 kVp + Sa36d, protocol C). The Agatston scores for protocols A and B, as well as protocols A and C, were compared. The agreement between the scores was assessed using the intraclass correlation coefficient (ICC) and the Bland-Altman plot. The radiation doses for the 120 kVp and UHP Sn150 kVp acquisition modes were also compared. Results: No significant difference was observed in the Agatston score for protocols A (median, 63.05; interquartile range [IQR], 0-232.28) and C (median, 60.25; IQR, 0-195.20) (p = 0.060). The mean difference in the Agatston score for protocols A and C was relatively small (-7.82) and with the limits of agreement from -65.20 to 49.56 (ICC = 0.997). The Agatston score for protocol B (median, 34.85; IQR, 0-120.73) was significantly underestimated compared with that for protocol A (p < 0.001). The UHP Sn150 kVp mode facilitated an effective radiation dose reduction by approximately 30% (0.58 vs. 0.82 mSv, p < 0.001) from that associated with the standard 120 kVp mode. Conclusion: The Agatston scores for CACS with the UHP Sn150 kVp mode with a kVp-independent reconstruction algorithm and the standard 120 kVp demonstrated excellent agreement with a small mean difference and narrow agreement limits. The UHP Sn150 kVp mode allowed a significant reduction in the radiation dose.

Cycle-Consistent Generative Adversarial Network: Effect on Radiation Dose Reduction and Image Quality Improvement in Ultralow-Dose CT for Evaluation of Pulmonary Tuberculosis

  • Chenggong Yan;Jie Lin;Haixia Li;Jun Xu;Tianjing Zhang;Hao Chen;Henry C. Woodruff;Guangyao Wu;Siqi Zhang;Yikai Xu;Philippe Lambin
    • Korean Journal of Radiology
    • /
    • 제22권6호
    • /
    • pp.983-993
    • /
    • 2021
  • Objective: To investigate the image quality of ultralow-dose CT (ULDCT) of the chest reconstructed using a cycle-consistent generative adversarial network (CycleGAN)-based deep learning method in the evaluation of pulmonary tuberculosis. Materials and Methods: Between June 2019 and November 2019, 103 patients (mean age, 40.8 ± 13.6 years; 61 men and 42 women) with pulmonary tuberculosis were prospectively enrolled to undergo standard-dose CT (120 kVp with automated exposure control), followed immediately by ULDCT (80 kVp and 10 mAs). The images of the two successive scans were used to train the CycleGAN framework for image-to-image translation. The denoising efficacy of the CycleGAN algorithm was compared with that of hybrid and model-based iterative reconstruction. Repeated-measures analysis of variance and Wilcoxon signed-rank test were performed to compare the objective measurements and the subjective image quality scores, respectively. Results: With the optimized CycleGAN denoising model, using the ULDCT images as input, the peak signal-to-noise ratio and structural similarity index improved by 2.0 dB and 0.21, respectively. The CycleGAN-generated denoised ULDCT images typically provided satisfactory image quality for optimal visibility of anatomic structures and pathological findings, with a lower level of image noise (mean ± standard deviation [SD], 19.5 ± 3.0 Hounsfield unit [HU]) than that of the hybrid (66.3 ± 10.5 HU, p < 0.001) and a similar noise level to model-based iterative reconstruction (19.6 ± 2.6 HU, p > 0.908). The CycleGAN-generated images showed the highest contrast-to-noise ratios for the pulmonary lesions, followed by the model-based and hybrid iterative reconstruction. The mean effective radiation dose of ULDCT was 0.12 mSv with a mean 93.9% reduction compared to standard-dose CT. Conclusion: The optimized CycleGAN technique may allow the synthesis of diagnostically acceptable images from ULDCT of the chest for the evaluation of pulmonary tuberculosis.

Phase I Clinical Trial of Prostate-Specific Membrane Antigen-Targeting 68Ga-NGUL PET/CT in Healthy Volunteers and Patients with Prostate Cancer

  • Minseok Suh;Hyun Gee Ryoo;Keon Wook Kang;Jae Min Jeong;Chang Wook Jeong;Cheol Kwak;Gi Jeong Cheon
    • Korean Journal of Radiology
    • /
    • 제23권9호
    • /
    • pp.911-920
    • /
    • 2022
  • Objective: 68Ga-NGUL is a novel prostate-specific membrane antigen (PSMA)-targeting tracer based on Glu-Urea-Lys derivatives conjugated to a 1,4,7-triazacyclononane-N,N',N''-triacetic acid (NOTA) chelator via a thiourea-type short linker. This phase I clinical trial of 68Ga-NGUL was conducted to evaluate the safety and radiation dosimetry of 68Ga-NGUL in healthy volunteers and the lesion detection rate of 68Ga-NGUL in patients with prostate cancer. Materials and Methods: We designed a prospective, open-label, single-arm clinical trial with two cohorts comprising six healthy adult men and six patients with metastatic prostate cancer. Safety and blood test-based toxicities were monitored throughout the study. PET/CT scans were acquired at multiple time points after administering 68Ga-NGUL (2 MBq/kg; 96-165 MBq). In healthy adults, absorbed organ doses and effective doses were calculated using the OLINDA/EXM software. In patients with prostate cancer, the rates of detecting suspicious lesions by 68Ga-NGUL PET/CT and conventional imaging (CT and bone scintigraphy) during the screening period, within one month after recruitment, were compared. Results: All 12 participants (six healthy adults aged 31-32 years and six prostate cancer patients aged 57-81 years) completed the clinical trial. No drug-related adverse events were observed. In the healthy adult group, 68Ga-NGUL was rapidly distributed, with the highest uptake in the kidneys. The median effective dose coefficient was calculated as 0.025 mSv/MBq, and cumulative activity in the bladder had the highest contribution. In patients with metastatic prostate cancer, 229 suspicious lesions were detected using either 68Ga-NGUL PET/CT or conventional imaging. Among them, 68Ga-NGUL PET/CT detected 199 (86.9%) lesions and CT or bone scintigraphy detected 114 (49.8%) lesions. Conclusion: 68Ga-NGUL can be safely applied clinically and has shown a higher detection rate for the localization of metastatic lesions in prostate cancer than conventional imaging. Therefore, 68Ga-NGUL is a valuable option for prostate cancer imaging.

Determine the hazards of radioactive elements and radon gas manufacturing processes in an Egyptian fertilizer factory

  • Soad Saad Fares
    • Nuclear Engineering and Technology
    • /
    • 제56권5호
    • /
    • pp.1781-1795
    • /
    • 2024
  • This study investigated the levels of radioactivity in soil surrounding a phosphate fertilizer factory in Egypt, aiming to assess potential risks to the population exposed to radiation. Concentrations of 238U, 226Ra, 232Th, and 40K were measured in soil samples collected from two subsites: one near the factory (subsite 1) and another further away (subsite 2). Two different systems were used for measuring radioactivity, a high-purity gamma ray spectroscopy system with an HPGe detector for gamma-emitting isotopes and a CR-39 solid nuclear track detector for alpha-emitting radon gas. Subsite 1, located close to the factory, displayed significantly elevated levels of 226Ra compared to global background levels (514 and 456 Bq/kg vs. 35 Bq/kg). Additionally, the concentrations of 238U (241.06 Bq/kg vs. global average 35 Bq/kg), 232Th (16.15 Bq/kg vs. global average 30 Bq/kg), and 40K (146.36 Bq/kg vs. global average 400 Bq/kg) were all above global averages. Furthermore, a high concentration of radon gas (337.06 μSv/y) was measured at subsite 1. The strong positive correlation observed between 226Ra and 238U (0.96256) provides further evidence of potentially elevated radioactivity levels near the factory. In contrast, subsite 2, situated farther from the factory, exhibited natural radioactive background levels within international limits. Quantitative analysis revealed that gamma ray absorbed doses for 226Ra and 232Th exceeded global averages in some samples. Specifically, 226Ra doses ranged from 7.8 to 46.26 ppm (exceeding the 20 ppm global average in some cases), and 232Th doses ranged from 1.98 to 9.14 ppm (exceeding the 10 ppm global average in some cases). The concentration of 40K, however, remained within the global range (0.07%-0.69 %). The observed imbalances in the ratios of Th/U (0.17-0.24 Bq/kg and 0.73-0.24 ppm) and U/Ra (0.81-0.73 Bq/kg and 0.73-0.17 ppm), both of which are significantly lower than their respective global averages of 4 and 2.4, point towards the presence of fertilizer-derived contamination. This conclusion is further supported by the high phosphate concentrations detected in the samples. Overall, this study suggests that radioactive contamination near the phosphate fertilizer factory significantly exceeds global background levels and international limits in some cases. This raises concerns about potential risks posed to surrounding agricultural land and crops.

잡종견 급성폐손상 모델에서 Prone position 시행시 PEEP 수준에 따른 호흡 및 혈류역학적 효과 (The Respiratory and Hemodynamic Effects of Prone Position According to the Level of PEEP in a Dog Acute Lung Injury Model)

  • 임채만;진재용;고윤석;심태선;이상도;김우성;김동순;김원동
    • Tuberculosis and Respiratory Diseases
    • /
    • 제45권1호
    • /
    • pp.140-152
    • /
    • 1998
  • 배 경: 호흡부전의 치료에 있어 환자 체위를 prone position으로 하는 시도는 20년 전부터 보고되어 왔으며 폐산소화 및 심박출량 향상에 효과가 있다는 것이 알려져 있다. Prone position시 폐산소화의 호전은 임상 및 동물 실험에서 단락 감소에 의한 것으로 알려져 있으며 그 중요 기전은 supine position에 비해 prone position때 중력 의존부 폐의 늑막압이 더 작아 폐포 개방압이 줄어들기 때문인 바 저자 등은 prone position이 폐산소화에 미치는 효과는 supine position에서 사용한 PEEP의 폐포 고비 개방압과의 관계에 따라 달라질 것으로 추정하였다. Prone position에서의 심박출량 증가에 대하여는 양압환기시 발생하는 cardiac fossa lifting 현상이 prone position에 의해 완화될 수 있다는 주장이 제기된 바 있어 prone position이 또한 supine position에서 PEEP에 의해 초래된 심박출량 저하를 완화시킬 수 있는지를 잡종견 급성 폐손상 모델을 통해 알아보고자 하였다. 방 법 : 잡종견 7 마리 ($20.0{\pm}3.9$ kg)를 정맥 마취 후 기관내관을 삽관하고 인공호흡기를 Vt 15 ml/kg, f 20/min, I : E=1 : 3, pause 10%, PEEP 0 cm $H_2O$, $F_1O_2$ 1.0으로 설정하였다. 혈압, 분당맥박수, 폐동맥쐐기압, 심박출량 등의 측정과 동맥혈가스분석을 위해 서혜동맥과 폐동맥 천자술을 시행하였다. 대조기에 supine position 및 prone position 30분에 각각 호흡 지표 ($PaO_2/F_1O_2$[P/F], 총호흡기계탄성 [Cst]와 supine position, prone position 5분 및 prone position 30분에 혈류역학적 지표(평균동맥압, 분당 맥박수, 심박출량, 박출용적)을 측정하고 섭씨 38도의 생리식염수 (30~50 ml/kg)를 기관내관을 통하여 주입하여 급성 폐손상을 유도한 뒤 constant flow 법에 의해 inflection point(Pflex)를 측정하였다. 급성 폐손상에서의 supine position과 prone position실험은 Pflex보다 2 cm $H_2O$ 낮은 PEEP(Low PEEP)과 2 cm $H_2O$ 높은 PEEP (Optimal PEEP)에서 순차적으로 시행하고 각각 통일 시간대에 상기 지표들을 측정하였으며 Optimal PEEP 실험 마지막에 다시 supin position으로 체위를 바꾸고 5분 뒤 혈류역학적 지표들을 측정하였다. 결 과: 1. Prone position 시행시 Low PEEP 및 Optimal PEEP에서의 호흡 효과의 차이 Low PEEP하에서 P/F 비는 supine position에서 $195{\pm}112$ mm Hg, prone position 30분에서 $400{\pm}33$ mm Hg였고 (p<0.001) Optimal PEEP하에서 P/F 비는 supine position에서 $466{\pm}63$ mm Hg, prone position 30분에서 $499{\pm}63$ mm Hg였다 (p=0.016). Prone position에 의한 P/F 비 싱승량은 Low PEEP하에서 $205{\pm}90$ mm Hg로 Optimal PEEP($33{\pm}33$ mm Hg) 하에서 보다 유의하게 높았다(각각 p<0.05). 2. Prone position의 혈류역학적 효과 Low PEEP하에서 심박출량은 supine position($3.0{\pm}0.7$ L/min) 과 비교하여 prone position 5분 $3.3{\pm}0.7$ L/min(p=0.0180)로 증가하였고 prone position 30분 $3.7{\pm}0.8$ L/min(p=0.0630)로 차이가 없었다. 분당맥박수는 각각 $141{\pm}22\;min^{-1}$, $141{\pm}22\;min^{-1}$(p=0.8658) 및 $176{\pm}28\;min^{-1}$(p=0.0280)이었고 폐동맥쐐기압은 차이가 없었다. Optimal PEEP하에서 평균동맥압은 각각 $87{\pm}19$ mm Hg, $107{\pm}18$ mm Hg(p=0.0180) 및 $108{\pm}16$ mm Hg(p=0.0180), 심박출량은 각각 $2.4{\pm}0.5$ L/min, $3.3{\pm}0.6$ L/min(p=0.0180) 및 $3.6{\pm}0.7$ L/min(p=0.0180), 그리고 박출용적은 각각 $14{\pm}2$ml, $20{\pm}2$ ml(p=0.0180) 및 $21{\pm}2$ ml(p=0.0180)였다. 분당맥박수는 체위 변경에 따른 차이가 없었고 폐동맥쐐기압은 각각 $10.1{\pm}2.4$ mm Hg, $9.1{\pm}2.7$ mm Hg(p=0.0180) 및 $9.0{\pm}3.1$ mm Hg(p=0.0679) 이었다. Optimal PEEP하 prone position에서 다시 supine position으로 체위를 바꾸고 5분 후 평균동맥압은 $92{\pm}23$ mm Hg, 심박출량은 $2.4{\pm}0.5$ L/min, 그리고 박출용적은 $14{\pm}1$ ml로 모두 감소하였다(모두 p<0.05). 결 론 : 잡종견 급성폐손상 모델에서 prone position은 비교적 낮은 수준 PEEP의 폐산소화 호전 효과를 중대시켰고, 비교적 놓은 수준 PEEP에 의한 심박출량 저하를 완화시켰다. 이러한 결과들은 심박출량을 유지하면서 폐산소화를 호전시키고자 하는 ARDS 환자에서의 기계환기의 목표를 달성하는데 있어 prone position이 supine position보다 유리하다는 것을 시사한다.

  • PDF

체력단련(體力鍛練)이 심전도파고(心電圖波高)와 QRS벡타에 미치는 효과(效果) (Effect of Physical Training on Electrocardiographic Amplitudes and the QRS Vector)

  • 유완식;황수관;김형진;주영은
    • The Korean Journal of Physiology
    • /
    • 제18권1호
    • /
    • pp.51-65
    • /
    • 1984
  • 장기간(長期間) 체력단련(體力鍛鍊)이 심전도파고(心電圖波高) 및 심전도(心電圖) vector에 미치는 효과(效果)를 구명(究明)하고자 10명(名)의 운동선수군(運動選手群)과 13명(名)의 비운동선수군(非運動選手群)에서 rebounder운동전후(運動前後)의 심전도파고(心電圖波高)와 QRS vector의 길이를 측정(測定)하여 분절(分折)한 결과(結果)는 다음과 같다. 심전도파고(心電圖波高)에서 R파고(波高)는 선수군(選手群)이 $23.38{\pm}1.14\;mm$로서 비선수군(非選手群)의 $17.91{\pm}2.00$\;mm$에 비(比)해 유의(有意)하게 높았고, 운동후(運動後)에도 선수군(選手群)이 계속(繼續) 유의(有意)하게 높았다. S파고(波高)는 양군(兩群) 모두 운동후(運動後)는 안정시(安靜時)에 비(比)해 유의(有意)하게 높았으며, T파고(波高)는 운동후(運動後) 감소(減少)하였다. P파고(波高)는 양군(兩群) 모두 운동후(運動後) 증가(增加)하였으며 선수군(選手群)이 다소 낮았다. PQ분절(分節)의 파고(波高)는 선수군(選手群)은 0인데 비(比)해 비선수군(非選手群)은 negative를 나타냈으며 운동후(運動後)에 유의(有意)하게 감소(減少)하였다. J점(點)은 양군(兩群) 모두 안정시(安靜時) positive에서 운동후(運動後) 유의(有意)하게 감소(減少)하여 negative를 나타냈고, J+0.08초(秒)도 운동후(運動後) 양군(兩群) 모두 감소(減少)하였으며 선수군(選手群)이 다소 높았다. 그러므로 ST분절(分節)은 운동후(運動後) 감소(減少)함을 알 수 있다. $Rv_5$$Sv_1$의 합(合)은 선수군(選手群)이 $38.74{\pm}2.71\;mm$로서 비선수군(非選手群)의 $32.28{\pm}2.90\;mm$에 비(比)해 높았으며 운동후(運動後)에도 선수군(選手群)이 유의(有意)하게 높았다. QRS vector 각도(角度)에서 Frontal plane에서 선수군(選手群)이 $62.7{\pm}7.36^{\circ}$로서 비선수군(非選手群)과 별(別) 차이(差異)가 없었고, horizontalplane에서는 선수군(選手群)이 $-23.5{\pm}7.2^{\circ}$로서 비선수군(非選手群)의 $-38.8{\pm}8.2^{\circ}$에 비(比)해 유의(有意)하게 높았으며 운동후(運動後) 양군(兩群) 모두 유의(有意)하게 높았다. QRS vector 길이에서 Frontal plane에서 선수군(選手群)이 $13.86{\pm}1.44\;mm$로서 비선수군(非選手群)의 $9.62{\pm}0.97\;mm$에 비(比)해 유의(有意)하게 높았으며 운동후(運動後)에도 유의(有意)하게 높았다. Horizontal plane에서도 선수군(選手群)이 $19.82{\pm}2.10\;mm$로서 비선수군(非選手群)의 $16.90{\pm}1.39\;mm$에 비(比)해 유의(有意)하게 높았고 운동후(運動後)에도 선수군(選手群)이 유의(有意)하게 높았다. 이상(以上)을 종합(綜合)해 보면 선수군(選手群)의 R파고(波高)가 비선수군(非選手群)에 비(比)해 운동후(運動後) 계속(繼續) 유의(有意)하게 높았고, $Rv_5$$Sv_1$파고(波高)의 합(合)이 38.74mm정도(程度)로 좌심실(左心室)이 비대(肥大)함을 알 수 있으며, 선수군(選手群)의 PQ분절파고(分節波高)와 ST분절(分節) 파고(波高)가 비선수군(非選手群)에 비(比)해 높고 운동후(運動後)에 양군(兩群) 모두 감소(減少)한 점(點)은 주목(注目)할만한 사실(事實)이며, 특(特)히 선수군(選手群)의 QRS vector의 길이가 모두 비선수군(非選手群)에 비(比)해 유의(有意)하게 긴점등(點等)으로 좌심실기능(左心室機能)이 우수(優秀)한 스포츠심장(心臟)임을 알 수 있으며, 선수군(選手群)과 비선수군(非選手群)을 평가(評價)할 수 있는 중요(重要)한 지표(指標)가 될 것으로 사료(思料)되는 바이다.

  • PDF

한국 청소년의 과일 및 채소 섭취와 관련된 인구사회학적 특성 및 식생활 분석: 국민건강영양조사 제7-8기 (2016-2019) 자료 이용 (Analysis of socio-demographic and dietary factors associated with fruit and vegetable consumption among Korean adolescents: use of data from the 7th and 8th Korea National Health and Nutrition Examination Survey (2016-2019))

  • 윤보경;계승희
    • Journal of Nutrition and Health
    • /
    • 제57권3호
    • /
    • pp.292-306
    • /
    • 2024
  • 본 연구의 목적은 국민건강영양조사 중 제7-8기 (2016-2019) 자료를 활용하여 청소년의 과일 및 채소 섭취실태 및 이에 영향을 미치는 인구사회학적 특성 및 식생활 관련요인을 탐색하고, 과일 및 채소 섭취에 따라 영양섭취 수준을 비교 분석하고자 하였다. 과일 및 채소를 모두 충분히 섭취한 인원은 1.40%이었으며, 모두 충분히 섭취하지 않는 인원의 비율은 79.54%이었다. 청소년의 과일 섭취에 영향을 주는 요인은 성별, 아버지 학력, 어머니 학력, 아침식사 빈도였다. 여자 청소년이 남자 청소년보다, 아버지 학력이 대학교 이상으로 높은 경우, 어머니 학력이 고등학교 이하로 낮은 경우, 아침식사 빈도가 주 3회 이상인 경우 3회 미만인 경우보다 과일을 충분히 섭취하였다. 청소년의 채소 섭취에 영향을 주는 요인은 성별과 가구소득이었다. 남자 청소년이 여자 청소년보다, 가구소득이 상인 경우 가구소득이 하인 경우 보다 채소를 충분히 섭취하였다. 청소년의 과일 및 채소 섭취에 영향을 주는 요인은 아침섭취빈도, 가구소득, 외식, 영양표시 인지 여부였다. 여자 청소년이 남자 청소년보다, 외식을 하루 1회 미만 하는 경우, 가구소득이 하인 경우, 영양표시를 인지하는 경우 과일 및 채소를 충분히 섭취하였다. 청소년의 1일 영양소 섭취량과 1일 영양섭취기준에 대한 영양소 섭취 비율은 과일 또는 채소의 섭취 수준에 따라 유의적인 차이가 나타났다. 칼슘과 철의 1일 권장량에 대한 섭취비율은 미충족군과 과일충족군에서 낮았으며, 비타민 A와 비타민 C의 1일 권장량에 대한 섭취비율은 미충족군에서 가장 낮았다. 그러나 과일 및 채소충족군은 칼슘과 비타민 A를 제외한 나머지 모든 영양소에서 1일 영양섭취기준의 100% 이상을 섭취하였다. 본 연구결과를 통하여 청소년이 과일 및 채소를 모두 충분히 섭취하는 경우 거의 모든 영양소의 1일 권장섭취량을 충족한 것으로 분석되었다. 그러나 과일 및 채소를 모두 충분히 섭취하는 인원의 비율은 매우 낮은 것으로 나타나 청소년의 과일 및 채소섭취를 장려할 수 있도록 구체적인 영양교육의 방안은 물론 현실적으로 효율적인 영양정책이 도입되어야 함을 시사하고 있다.

납형의 크기와 형태가 티타늄의 주조성에 미치는 영향 (Effect of different pattern size and pattern shape on castability of commercially pure titanium)

  • 서윤정;오계정;이효일;신유진;김홍주;박상원
    • 대한치과보철학회지
    • /
    • 제51권4호
    • /
    • pp.261-268
    • /
    • 2013
  • 연구 목적: 본 연구는 납형의 크기 및 형태 변화가 티타늄의 주조성에 어떠한 영향을 미치는지 확인하고자 하였다. 연구 재료 및 방법: 납형의 크기에 따라 Small Pattern군과 Large Pattern군으로 나누었고, 각각 Flat, Semicircular, Horse-shoe 및 V-shape형으로 납형의 형태에 따라 4개의 하위군으로 나누어 총 8개의 군으로 분류하였다. 모든 납형의 주입선은 Runner-bar형으로 하였다. 티타늄 주조 전용 매몰재인 실리카계 매몰재(Rematitan Plus$^{(R)}$, Dentarum, Germany)를 이용하여 매몰하였고, 아크용융 방식의 원심 주조기(Ti Cast Super R$^{(R)}$, Selec, Japan)를 사용하여 주조하였다. 주조성 평가는 완전한 형태로 주조 된 격자의 개수를 척도로 재현 정도를 확인하였다. 통계처리는 SPSS ver. 19.0 for WIN (SPSS. Inc. Chicago, IL, USA)를 사용하였다. 납형의 크기 및 형태에 따른 티타늄의 주조성을 이원변량 분산분석(Two-way ANOVA)을 이용하여 분석하였다. 결과:납형의 평균 재현율은 Small Pattern군은 95.14%, Large Pattern군은 94.30%로 Small Pattern군의 주조성이 유의하게 높았다(P<.05). 납형의 형태 변화에 따른 주조성은 Small Pattern군에서 Semicircular군 133.20개(96.52%), Horse-shoe군 132.40개(95.94%), Flat군 132.00개(95.65%), V-shape군 127.60개(92.46%) 순으로 감소하였다. Large Pattern군은 Flat군 198.60개(95.94%), V-shape군 197.80개(95.56%), Semicircular군 196.40개(94.88%), Horse-shoe군 188.00개(90.82%)순으로 감소하였다. Small Pattern군과 Large Pattern군 모두에서 납형의 형태변화에 따른 주조성은 유의할 만한 차이를 보이지 않았다(P>.05). 결론:주조체의 크기가 작을수록 주조성이 높아짐을 알 수 있었고 형태에 따른 주조성에서는 큰 영향을 받지 않는 것을 알 수 있었다.