• Title/Summary/Keyword: SV(Sampled Values)

Search Result 6, Processing Time 0.021 seconds

Traffic Generation Method of Sampled Values for Smart Grid (스마트 그리드를 위한 샘플 값들의 트래픽 발생 방안)

  • Hwang, Sung-Ho;Park, Kyung-Won;Park, Jeong-Do;Song, Han-Chun;Park, Jae-Do
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.6
    • /
    • pp.225-230
    • /
    • 2015
  • This study presents a method for generating IEC 61850 Sampled Values(SV) traffic by combining the emulation function of network simulator ns-3 with the actual communication equipment. For the SV traffic generation and reception, the emulation function of the network simulator ns-3 is used, while as a communication network, the actual communication equipment, switches are used. In addition, the SV traffic frames generated are analyzed, using Wireshark, and it is confirmed that the SV traffic frames are generated accurately. The method for the SV traffic generation proposed in the present study will be very useful when various SV traffics are generated under the environment of an actual substation.

A Study on IEC61850-9-2 Distributed Sampled Measured Values Applications for Merging Unit at Process Level (프로세스 레벨의 병합 단위장치를 위한 IEC61850-9-2 샘플링 값 서비스 구현에 관한 연구)

  • Kim, Gwan-Su;Lee, Hong-Hee;Kim, Byung-Jin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.7
    • /
    • pp.1177-1182
    • /
    • 2007
  • Recently, IEC61850 supports the standardized communication technique in both station bus and process bus, and presents the substation automation model. In this paper, we propose the required techniques to develop the Merging Unit (MU), which is one of the important data acquisition equipment in substation automation, under IEC61850 communication protocol. Especially, we also propose the precision time synchronization technique using GPS(Global Positioning System) for the MU. IEC61850-9-2 SV (Sampled Value) service is applied to the MU which is designed using microprocessor. In order to evaluate the performance of the proposed MU, the playback program, which can reconstruct the transmitted sampled value data on the basis of time information, is developed and the performance of the IEC61850 SV service for MU is verified experimentally.

Transmission for IEC 61850 Sampled Values Using Current and Voltage Sensors of Raspberry Pi (라즈베리파이 전류와 전압 센서를 이용한 IEC 61850 샘플 값 전송)

  • Hwang, Sung-Ho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.18 no.6
    • /
    • pp.157-162
    • /
    • 2018
  • This study uses sensors and Raspberry Pi to measure the values of current and voltage and transmits the measured sampled values to a network, carrying them in the frame of IEC 61850-9-2. A laboratory model was composed to send the sampled values, using the frame of IEC 61850-9-2. This study conducted a protocol analysis, using Wireshark for the accurate verification of the occurrence of the frame of IEC 61850-9-2. A visual analysis was conducted by displaying the received sampled values of current and voltage on the monitor in graphs. In addition, this study tested if the sampled values of IEC 61850-9-2 sent and received through the network equipment would meet the performance requirements of the message types of IEC 61850.

A Study on the Testing Method of IEC 61850 based Merging Unit (IEC 61850 기반 디지털 변전시스템의 머징유닛 시험방법에 관한 연구)

  • Lee, Nam-Ho;Jang, Byung-Tae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.8
    • /
    • pp.41-47
    • /
    • 2009
  • The power IT project "Development of Prototype for Advanced Substation Automation System based on the Digital Control Technology", is going on how to perform the verification of a IEC 61850 based Merging Unit for development of the full Substation Automation system from station bus to process bus. the testing method that this paper suggests, is including the conformance testing of IEC 61850 communication services and transmission functions of digital sampled values such as current and voltage, and referring to IEC 61850 conformance testing of IED. And finally, the paper shows a test system for the Merging Unit.

Performance Enhancement for Fault Location Using GOOSE Messages (GOOSE 메시지를 이용한 고장점 추정 성능 개선)

  • Go, Chol-Jin;Kang, Sang-Hee
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.4
    • /
    • pp.144-150
    • /
    • 2006
  • IEC 61850 is the worldwide protocol for the substation automation system. IEC 61850 transports the information which consists of different formats such as GOOSE(Generic Object Oriented Substation Event), MMS(Manufacturing Message Specification), SV(Sampled Values) and so on. For real time data transmission, GOOSE can be used. The remote-bus current data which were collected in a local-bus current differential IED can be transmitted to a distance IED at the same location by using GOOSE messages. The distance IED can eliminate the reactance effect by using the transmitted remote-bus current data. This method can improve the performance of the fault location.

Fish Stock Assessment by Hydroacoustic Methods and its Applications - I - Estimation of Fish School Target Strength - (음향에 의한 어족생물의 자원조사 연구 - I - 어군반사강도의 추정 -)

  • Lee, Dae-Jae;Shin, Hyeong-Il;Shin, Hyong-Ho
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.31 no.2
    • /
    • pp.142-152
    • /
    • 1995
  • The combined bottom trawl and hydroacoustic survey was conducted by using the training ship Oshoro Maru belong to Hokkaido University in November 1989-1992 and the training ship Nagasaki Maru belong to Nagasaki University in April 1994 in the East China Sea, respectively. The aim of the investigations was to collect the target strength data of fish school in relation to the biomass estimation of fish in the survey area. The hydroacoustic survey was performed by using the scientific echo sounder system operating at three frequencies of 25, 50 and 100kHz with a microcomputer-based echo integrator. Fish samples were collected by bottom trawling and during the trawl surveys, the openings of otter board and net mouth were measured. The target strength of fish school was estimated from the relationship between the volume back scattering strength for the depth strata of bottom trawling and the weight per unit volume of trawl catches. A portion of the trawl catches preserved in frozon condition on board, the target strength measurements for the defrosted samples of ten species were conducted in the laboratory tank, and the relationship between target strength and fish weight was examined. In order to investigate the effect of swimbladder on target strength, the volume of the swimbladder of white croaker, Argyrosomus argentatus, sampled by bottom trawling was measured by directly removing the gas in the swimbladder with a syringe on board. The results obtained can be summarized as follows: 1.The relationship between the mean volume back scattering strength (, dB) for the depth strata of trawl hauls and the weight(C, $kg/\textrm{m}^3$) per unit volume of trawl catches were expressed by the following equations : 25kHz : = - 29.8+10Log(C) 50kHz : = - 32.4+10Log(C) 100kHz : = - 31.7+10Log(C) The mean target strength estimates for three frequencies of 25, 50 and 100 kHz derived from these equations were -29.8dB/kg, -32.4dB/kg and -31.7dB/kg, respectively. 2. The relationship between target strength and body weight for the fish samples of ten species collected by trawl surveys were expressed by the following equations : 25kHz : TS = - 34.0+10Log($W^{\frac{2}{3}}$) 100kHz : TS = - 37.8+10Log($W^{\frac{2}{3}}$) The mean target strength estimates for two frequencies of 25 and 100 kHz derived from these equations were -34.0dB/kg, -37.8dB/kg, respectively. 3. The representative target strength values for demersal fish populations of the East China Sea at two frequencies of 25 and 100 kHz were estimated to be -31.4dB/kg, -33.8dB/kg, respectively. 4. The ratio of the equivalent radius of swimbladder to body length of white croaker was 0.089 and the volume of swimbladder was estimated to be approximately 10% of total body volume.

  • PDF