• Title/Summary/Keyword: SUVs

Search Result 45, Processing Time 0.034 seconds

Characteristic of $^{18}F$-FDG Excretion According to Use Diuretics in $^{18}F$-FDG of PET/CT ($^{18}F$-FDG PET/CT 검사에서 이뇨제 사용여부에 따른 $^{18}F$-FDG 배설 특성)

  • Jang, Dong-Gun;Yang, Seoung-Oh;Lee, Sang-Ho;Bae, Jong-Lim;Kim, Jeong-Koo
    • Journal of radiological science and technology
    • /
    • v.35 no.2
    • /
    • pp.151-156
    • /
    • 2012
  • $^{18}F$-fluorodeoxyglucose ($^{18}F$-FDG) causes a significant amount of radioactivity retention in kidneys and urinary tract and degrades image quality and diagnostic performance. Diuretics are used to perform tests and prevent the urinary tract retention of $^{18}F$-FDG. The purpose of the study is to investigate how the diuretics affect images and excretion rates of $^{18}F$-FDG. The study consists of a group using diuretics for patients with no primary tumors or transfer lesions in kidneys according to PET/CT images, a group using physiological saline and the control group injecting only $^{18}F$-FDG and SUVs are measured by configuring interested areas for each group. Also, SUVs are compared and evaluated depending on the lasix injection after basic inspection and injecting $^{18}F$-FDG for quantitative analysis. The study shows that images with decreased background radioactivity and increased urine excretion due to using diuretics. However, an opposite result that there is no change in the amount of radioactivity in urine appears. The study concludes that the diuretics may decrease background radioactivity in the images but may not affect the $^{18}F$-FDG excretion.

A Study on Appropriate Breadth for U-turn Setup (U-turn 설치를 위한 적정 폭원에 관한 연구)

  • Lee, Jin-Uk;Kim, Gi-Hyeok
    • Journal of Korean Society of Transportation
    • /
    • v.27 no.3
    • /
    • pp.39-47
    • /
    • 2009
  • Currently, the minimum breadth as a point available for U-turn setup is designated as "over 9m for one way" in the traffic safety facilities practical manuals, and vehicles allowed to make a U-turn are limited to passenger cars. However, as passenger cars have recently become larger and SUVs (Sports Utility Vehicles) are being popularized, they fail to make a U-turn in one attempt. This causes a traffic jam and a problem with traffic safety. This study proposed, compared, and tested the measured values of actual differences in the turning radius of U-turn by actual cars with estimated values by using PC-Crash, a car accident simulation program. Then, the study forecasted the turning radius of U-turns of Korean passenger cars by using PC-Crash, and proposed appropriate breadth for U-turn setup.

A Study on Car-to-car Frontal Impact Considering the Vehicle Compatibility (상호안전성을 고려한 차대차 정면 충돌 안전성 선행 연구)

  • Lee, Chang min;Shin, Jang ho;Kim, Hyun woo;Park, Kun ho;Park, Young joon
    • Journal of Auto-vehicle Safety Association
    • /
    • v.9 no.1
    • /
    • pp.13-18
    • /
    • 2017
  • In recent years, NCAP regulations of many countries have induced automaker to improve the vehicle crashworthiness. But, the current NCAP regulations don't cover all types of traffic accidents. And rapid-increasing market share of compact cars and SUVs has brought for both consumer and automaker to pay more attention on crash compatibility. So, many countries have tried to develop the new crash test mode and update the present crash test mode. Especially, Euro NCAP has been developing a new impact protocol of the car-to-car frontal offset impact including the crash compatibility assessment. There are plans to introduce this new protocol in 2020, and it will be replaced the current Euro NCAP frontal offset impact. The test dummy in the front seats of this new test mode will be changed from 50% Hybrid-III male to 50% THOR male. This paper will address the vehicle responses, the occupant responses and the vehicle compatibility performance from a full vehicle crash test using the new car-to-car frontal offset test protocol of Euro NCAP.

A Study on the MSATs (Mobile source Air Toxics) Contribution from MDTs (Medium-duty Trucks) Exhaust Emission (중형트럭에서 발생하는 배출가스 중 미량유해물질 발생 특성 연구)

  • Lim, Yun Sung;Mun, Sun Hee;Lee, Jong Tae;Dong, Jong In
    • Journal of ILASS-Korea
    • /
    • v.24 no.1
    • /
    • pp.21-26
    • /
    • 2019
  • In Korea, Medium-duty trucks are classified into GVW (Gross Vehicle Weight) 3.5~10tons. MDTs are mostly used for logistics or delivery between regions. There have been studied on diesel fuel vehicles for SUVs(Sports Utility Vehicle) or light-duty trucks. But MDTs have been not studied. Therefore, this study have been used MDTs for characteristic exhaust emission. Test was carried out using the certification test mode (NEDC, New European Driving cycle) and the NIER mode in chassis dynamometer of the MDTs. And emission gas was analyzed for PN (Particulate Number), PN size distribution and aldehydes, VOCs (Volatile Organic Compounds), PAHs (Polycyclic Aromatic Hydrocarbons). This paper concluded that EURO-IV trucks produced more MSATs than EURO V trucks. Depending on the engine temperature, more MSATs were generated in cold temperature than in the hot start operation. However, the driving speed, the opposite results was obtained.

Brand Revitalization by Strategic Repositioning: A Case Study of Korando Sports

  • Shin, Youngsik;Cha, Kyoung Cheon
    • Asia Marketing Journal
    • /
    • v.14 no.4
    • /
    • pp.1-22
    • /
    • 2013
  • A growing gap between market needs and the capabilities of the enterprise prompts repositioning (Corstjens and Dolye 1989). This article examines the strategic repositioning of 'Korando Sports' undertaken by SYMC throughout the period from Jan. 2012 to Jun. 2012, to boost sales volume and market share by entering market of active-lifestyle consumers currently occupied by SUVs. SYMC's experience indicates that it is essential to close the gap between the market needs and the ability of the enterprise to make a shift to new consumer segment with a new positioning. The successful repositioning framework(Ryan et al. 2007) were employed in this paper. This framework is comprised of six elements: core strategic values, strategic flexibility/learning capabilities, customer awareness and sensitivity, external orientation, management commitment, and belief in the product and brand. The evaluation based on the successful framework also confirms that 'Korando Sports' case meets all the requirements of the successful strategic repositioning. This paper provides some of the managerial implications with aim of assisting executives in identifying strategic repositioning opportunities. Primarily, the 'Korando Sports' case affirms the repositioning as a viable strategy and indicates that repositioning is a feasible means for strategic change. Second, this case shows the influence of a target consumer and SYMC's repositioning to follow consumer preference for a particular attribute. Moreover, we can understand how a product formerly considered weak in attributes can enjoy benefits in other segments with the same attributes.

  • PDF

Study on the Difference of Standardized Uptake Value in Fusion Image of Nuclear Medicine (핵의학 융합영상의 표준섭취계수 차이에 관한 연구)

  • Kim, Jung-Soo;Park, Chan-Rok
    • Journal of radiological science and technology
    • /
    • v.41 no.6
    • /
    • pp.553-560
    • /
    • 2018
  • PET-CT and PET-MRI which integrates CT using ionized radiation and MRI using phenomena of magnetic resonance are determined to have the limitation to apply the semi-quantitative index, standardized uptake value (SUV), with the same level due to the fundamental differences of image capturing principle and reorganization, hence, their correlations were analyzed to provide their clinical information. To 30 study subjects maintaining pre-treatment, $^{18}F-FDG$ (5.18 MBq/㎏) was injected and they were scanned continuously without delaying time using $Biograph^{TM}$ mMR 3T (Siemens, Munich) and Biograph mCT 64 (Siemens, Germany), which is an integral type, under the optimized condition except the structural differences of both scanners. Upon the measurement results of $SUV_{max}$ setting volume region of interest with evenly distributed radioactive pharmaceuticals by captured images, $SUV_{max}$ mean values of PET-CT and PET-MRI were $2.94{\pm}0.55$ and $2.45{\pm}0.52$, respectively, and the value of PET-MRI was measured lower by $-20.85{\pm}7.26%$ than that of PET-CT. Also, there was a statistically significant difference in SUVs between two scanners (P<0.001), hence, SUV of PET-CT and PET-MRI cannot express the clinical meanings in the same level. Therefore, in case of the patients who undergo cross follow-up tests with PET-CT and PET-MRI, diagnostic information should be analyzed considering the conditions of SUV differences in both scanners.

A Study of the Changes of Breast Uptake in Menstrual Cycle on 18F-FDG PET/CT (월경 주기에 따른 18F-FDG PET/CT에서 유방 섭취 변화에 관한 고찰)

  • Tak, Yeojin;Park, Min Soo;Lee, Juyoung;Park, Hoon-Hee
    • Journal of radiological science and technology
    • /
    • v.38 no.1
    • /
    • pp.31-38
    • /
    • 2015
  • $^{18}F-FDG$ PET/CT has been known a useful modality to diagnose high-glucose-using cells such as cancer cells by glucose metabolism of FDG. Mainly, FDG takes on cancer and inflammatory cells; however, there have been FDG uptakes on normal tissues by individual physiological characteristics, occasionally. Especially, in fertile females, unusual FDG uptake of breast changes as the menstrual cycle, and disturb diagnosis. Therefore, the study aimed to evaluate the change of breast FDG uptake in menstrual cycle on $^{18}F-FDG$ PET/CT. 160 females ($34{\pm}3.5$ years old) who do not undergo a gynecologic anamnesis and have regular menstrual cycle over the previous 6 months were examined. They were divided 4 groups (each 40 patients) as flow phase, proliferative phase, ovulatory phase and secretory phase using Pregnancy Calculator 0.14. and history taking. Discovery Ste (GE Healthcare, Milwaukee, Mi, USA) was used a s PET/CT. We analyzed SUVs on accumulated region on breast, and 3 nuclear medicine specialists did the Blind test. SUVs on the Breast were flow phase ($1.64{\pm}0.25$), proliferative phase ($0.93{\pm}0.28$), ovulatory phase ($1.66{\pm}0.26$) and secretory phase ($1.77{\pm}0.28$). It showed high uptake value in secretory, flow phase and ovulatory phase (p<0.05). In gross analysis, the accumulation of breast was divided into 3 grades as comparing with lung and liver. The breast's uptake was equal to lung (Grade I); between lung and liver (Grade II); equal to or greater than liver (Grade III). The results showed high uptake value in secretory, flow phase and ovulatory phase (p<0.05). In fertile females, FDG uptake of breast changed as menstrual cycle, and it available to diagnose breast disease. Therefore, we consider reducing false-negative finding of breast disease, by doing examination on appropriate period through history taking about individual menstrual cycle.

An Initial Study on the Reliability Assurance in PET/CT Standardized Uptake Values (PET/CT 에서 표준섭취계수(SUV)의 신뢰성 확보를 위한 초기연구)

  • Park, Hoon-Hee;Kim, Jung-Yul;Lee, Seung-Jae;Park, Min-Soo;NamKoong, Hyuk;Lim, Han-Sang;Oh, Ki-Baek;Kim, Jae-Sam;Lee, Chang-Ho;Jin, Gye-Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.31-42
    • /
    • 2009
  • Purpose: As the number of domestic medical institutions installing PET/CT is increasing rapidly, the transfer of PET/CT images among medical institutions is also increasing. Thus, it is necessary to collect the comparative SUV data from several medical institutions' PET/CT systems through a phantom study which semi-quantitatively compares the SUV on one bed, the change scale of the SUV on the slices, and the time of measuring. The phantom study to find differences among the SUVs from various PET/CT offers the opportunity to obtain the reliability of the SUV in PET/CT images. Materials and Methods: Ten PET/CT systems from medical institutions in Korea were used. To obtain the accurate data, the study has been using the radiation detector of Korea Research Institute of Standards and Science to verify. The internal structures of NEMA $phantom^{TM}$ were removed and Six thousand milliliters of distilled water which has 1mCi of $^{18}F$-FDG put into the phantom. The water was properly integrated with $^{18}F$-FDG using magnetic stirrer. The images were acquired at 60, 70, 80, 90, 100, 110 and 120-minutes for 3 minute each. Two hundred square centimeters of region of interests were placed and analyzed. To confirm the usefulness, the correction-table came out from patients' data. Results: The coefficient of variability of the SUV from -11.0 to 9.90 % fell into the range of international standards(${\pm}10%$) along with the SUV on a bed, the change scale of the SUV on the slices, and the time of measuring, except one PET/CT system. Using the data of the differences among the SUVs, we came to withdraw the correction-table ranging from 0.803 to 1.246. The correction-table was confirmed its usefulness through Linear Regression Analysis which was applied to normal cases. Conclusions: Although studies have been made on the variation of the SUV, there is little attention on the standardization of the SUV. Based on this study of the quantitatively comparable data about the SUV accommodating the correction-table, it would help to have more corrective diagnosis.

  • PDF

The Study of Usefulness of Metal Artifact Reduction Algorithm and Artifacts Caused by Metallic Hip Prosthesis on PET/CT (PET/CT에서의 고관절 삽입물에 의한 인공물과 Metal Artifact Reduction Algorithm의 유용성에 대한 고찰)

  • Park, Min Soo;Ham, Jun Cheol;Cho, Yong In;Kang, Chun Goo;Park, Hoon-Hee;Lim, Han Sang;Lee, Chang Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.35-43
    • /
    • 2012
  • Purpose : PET/CT performed CT-based attenuation correction generates the beam hardening artifact by metallic implant. The attenuation correction causes over or underestimate of the area adjacent to metallic hip prosthetic material and change of $^{18}F$-FDG uptake. Also, the image quality and the diagnosability on genitourinary disease are reduced. Therefore, this study will evaluate the usefulness of MAR (Metal Artifact Reduction) algorithm method to improve the image quality on PET/CT. Materials and Methods : PET/CT was performed by fixing hip prosthesis in SPECT/PET phantom. In PET images with and Without MAR algorithm, the Bright streak, Dark streak, Metal region and Background area that appeared on CT were confirmed, and the change of each SUV (standardized uptake value) was analyzed. Also, in 15 patients who underwent total hip arthroplasty, each MAR algorithm and Without MAR algorithm and non attenuation correction was evaluated. Results : In PET image Without MAR algorithm, SUV of Bright streak region was $0.98{\pm}0.48$ g/ml; Dark streak region was $0.88{\pm}0.02$ g/ml; Metal region was $0.24{\pm}0.16$ g/ml, Background area was $0.91{\pm}0.18$ g/ml. In SUV of PET image with MAR algorithm, Bright streak region was $0.88{\pm}0.49$ g/ml, Dark streak region was $0.63{\pm}0.21$ g/ml, Metal region was $0.06{\pm}0.07$ g/ml, Background was $0.90{\pm}0.02$ g/ml. SUV generally decreased when applying MAR algorithm. In PET image Without MAR algorithm, SUVs of Bright region were higher than those measured in the Background, and it was false positive uptake. But, in PET image with MAR algorithm, SUVs of Bright region were similar to the Background, and false positive uptake disappeared. Conclusion : MAR algorithm could reduce an increase of $^{18}F$-FDG uptake due to attenuation correction in the hip surrounding tissue. However, decrease of SUV in Dark streak region should be considered in the future. Therefore, this study propose that the diagnostic accuracy can be improved in genitourinary diseases adjacent to metallic hip prosthesis, if provided PET images with and Without MAR algorithm, and non attenuation correction images at the same time.

  • PDF

A Study of the Change of Breast Uptake in Menstrual Cycle on $^{18}F$-FDG PET/CT (월경 주기에 따른 $^{18}F$-FDG PET/CT에서의 유방 섭취 변화에 관한 고찰)

  • Park, Min-Soo;Park, Hoon-Hee;Kim, Jung-Yul;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.39-44
    • /
    • 2011
  • Purpose: $^{18}F$-FDG PET/CT has been known a useful modality to diagnose high-glucose-using cells such as cancer cells by glucose metabolism of FDG. Mainly, FDG takes on cancer and inflammatory cells; However, There have been FDG uptakes on normal tissues by individual physiological characteristics, occasionally. Especially, in fertile females, unusual FDG uptake of breast changes as the menstrual cycle, and disturb diagnosis. Therefore, the study aimed to evaluate the change of breast FDG uptake in menstrual cycle on $^{18}F$-FDG PET/CT. Materials and Methods: 160 females ($34{\pm}3.5$ years old) who do not undergo a gynecologic anamnesis and have regular menstrual cycle over the previous 6 months were examined, from March 2009 to February 2010. They were divided 4 groups (each 40 patients) as flow phase, proliferative phase, ovulatory phase and secretory phase using Pregnancy Calculator 0.14. and history taking. Discovery Ste (GE Healthcare, Milwaukee, Mi, USA) was used as PET/CT. We analyzed SUVs on accumulated region on breast, and 3 nuclear medicine specialists did the Blind test. Results: SUVs on the Breast were flow phase ($1.64{\pm}0.25$), proliferative phase ($0.93{\pm}0.28$), ovulatory phase ($1.66{\pm}0.26$) and secretory phase ($1.77{\pm}0.28$). It showed high uptake value in secretory, flow phase and ovulatory phase (p<0.05). In gross analysis, the accumulation of breast was divided into 3 grades as comparing with lung and liver. The breast's uptake was equal to lung (Grade I); between lung and liver (Grade II); equal to or greater than liver (Grade III). The results showed high uptake value in secretory, flow phase and ovulatory phase (p<0.05). Conclusion: In fertile females, FDG uptake of breast changed as menstrual cycle, and it available to diagnose breast disease. Therefore, we consider reducing false-negative finding of breast disease, by doing examination on appropriate period through history taking about individual menstrual cycle.

  • PDF