• Title/Summary/Keyword: SUN TEST

Search Result 7,512, Processing Time 0.037 seconds

Studies on the Standard Protocols of Bioequivalence Test

  • Yoon, Kyung-Eun;Chung, Soo-Youn;Park, Ki-Sook;Choi, Hong-Suk;Baek, Min-Sun;Jung, Sung-Hee;Choi, Sun-Ok
    • Proceedings of the PSK Conference
    • /
    • 2003.04a
    • /
    • pp.315.1-315.1
    • /
    • 2003
  • After beginning the new medical system separating the prescription from the drug dispensary, the demand of bioequivalence test significantly increases to show the equivalence between the test and reference drugs as a result of amendment of the pharmaceutical affairs law which allows a generic substitution. Accordingly the standard protocols provided by the government are required for reducing the period andthe cost to perform the bioequivalence study. (omitted)

  • PDF

Launch and Early Orbit Phase Simulations by using the KOMPSAT Simulator

  • Lee, Sanguk;Park, Wan-Sik;Lee, Byoung-sun;Lee, Ho-Jin;Park, Hanjun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1999.10a
    • /
    • pp.33-36
    • /
    • 1999
  • The KOMPSAT, which is scheduled to be launched by Taurus launch vehicle in late November of 1999, will be in a sun-synchronous orbit with an altitude of 685km, eccentricity of 0.001, inclination of 98deg and local time of ascending node of 10:50 a.m. Electronics and Telecommunications Research Institute and Daewoo Heavy Industry had jointly developed a KOMPSAT Simulator as a component of the KOMPSAT Mission Control Element. The MCE had been delivered to Korea Aerospace Research Institute for the KOMPSAT ground operation. It is being used for training of KOMPSAT ground station personnel. Each of satellite subsystems and space environment were mathematically modeled in the simulator. To verify the overall function of KOMPSAT simulator, a Launch and Early Orbit Phase(LEOP) operation simulations have been performed. The simulator had been verified through various tests such as functional level test, subsystem test, interface test, system test, and acceptance test. In this paper, simulation results for LEOP operations to verify flight software adapted into simulator, satellite subsystem models and environment models are presented.

  • PDF

Prediction of Maneuverability of KCS with 4 Degrees of Freedom (KCS 선형의 4자유도 조종성능 추정)

  • Kim, Yeon-Gyu;Yeo, Dong-Jin;Son, Nam-Sun;Kim, Sun-Young;Yun, Kun-Hang;Oh, Byeong-Ik
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.48 no.3
    • /
    • pp.267-274
    • /
    • 2011
  • This paper presents the results of prediction of maneuverability of KCS about 4 degree of freedom(DOF) including roll motion. The prediction is carried out by CPMC captive model test. The CPMC(Computerized Planar Motion Carriage) with captive model test equipment including roll moment gage is installed at Ocean Engineering Tank of MOERI. KCS is the container ship open to the world by MOERI. To predict the 4 DOF maneuverability of a ship some tests with roll angle are conducted. And the prediction results of maneuverability by simulation are compared with the results of free running model test. The simulation results agree well with those of free running model tests.

Building test bed of submerged gabion groyne to prevent bank erosion of curved channel (하천 만곡부 세굴 방지를 위한 잠형 수제 Test bed 구축)

  • Kim, Chang Sun;Lim, Dae Sik;Chung, Sun Kil;Lee, Hyun Jae;Hyun Jae, Lee
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.86-86
    • /
    • 2019
  • 일반적으로 하천에 설치하는 각종 이수 및 치수 시설물들은 각각의 고유기능을 충분히 발휘하도록 계획하고 설치하고 있으나, 이러한 하천 시설물 중에는 하천의 자연 환경에 부정적인 영향을 일으킬 수 있는 환경과 조화롭지 못한 시설물이 있기도 하다. 하도 만곡부에 설치하는 전통적인 수제, 즉 하안부에서 수로 중심방향으로 돌출하는 형식의 횡수제, 역시 외곽부 하안의 침식을 방지하기 위해 설치하는 시설물이지만 하천의 자연환경 측면에서는 바람직하지 못 한 현상을 일으키기도 한다. 본 연구에서 소개하는 잠형의 방틀공 수제는 하안부에 돌출하여 설치하는 기존 수제와 달리 만곡부 외측 하안에 근접하여 유수 방향으로 하상에 고정시키고 홍수 시에는 잠길 수 있는 높이로 방틀공을 설치하여 하천수의 흐름을 제어하는 시설물이다. 이와 같은 시설물은 만곡부에서 발생하는 2차류 흐름을 방지하고 유수의 수충력을 흡수 혹은 반사시킴으로써 하안부를 세굴로부터 보호할 뿐만 아니라 심각한 하상 세굴과 퇴적을 완화하는 하도의 안정 기능도 발휘하게 된다. 치수의 기능 외에도 하천 환경 측면에서는 수제의 안쪽에 형성되는 못 (pool)에 다양한 생물이 서식하는 서식기능을 담당하기도 한다. 본 고에서는 현재까지 국내에 설치한 사례가 없는 잠형 방틀형 수제의 효과를 검증하기 위해 강원도 양양 남대천에 구축하는 Test bed를 소개하고자 한다. 산지하천의 만곡부 하안부를 세굴로부터 보호하기 위해 설치하는 잠형 수제에 대한 Test bed 구축 배경과 설치 과정 등을 소개하여 이와 관련한 하천 기술자들에게 새로운 패러다임의 수제 설계가 이루어질 수 있는 계기를 제공하고자 한다.

  • PDF

Electrodeposited Ni-W-Si3N4 alloy composite coatings: Evaluation of Scratch test

  • Gyawali, Gobinda;Joshi, Bhupendra;Tripathi, Khagendra;Lee, Soo Wohn
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2014.11a
    • /
    • pp.178-179
    • /
    • 2014
  • In this study, $Ni-W-Si_3N_4$ alloy composite coatings were prepared by pulse electrodeposition method using nickel sulfate bath with different contents of tungsten source, $Na_2WO_4.2H_2O$, and dispersed $Si_3N_4$ nano particles. The structure and microstructure ofcoatings was separately analyzed by X-ray diffraction (XRD) and scanning electron microscope (SEM). Results indicated that nano $Si_3N_4$ and W content in alloy had remarkable effect on microstructure, microhardness and scratch resistant properties. Tungsten content in Ni-W and $Ni-W-Si_3N_4$ alloy ranged from 7 to 14 at.%. Scratch test results suggest that as compared to Ni-W only, $Ni-W-Si_3N_4$ prepared from Ni/W molar ratio of 1:1.5 dispersed with 20 g/L $Si_3N_4$ has shown the best result among different samples.

  • PDF

A Study on Threshold of Hearing of Sun shade Motor Sound Using Masking Effect (마스킹 효과를 이용한 선셰이드 모터음의 최소가청치 특성에 관한 연구)

  • Jo, Hyeonho;Seong, Wonchan;Kim, Seonghyeon;Park, Dongchul;Kang, Yeonjune
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.116-121
    • /
    • 2013
  • Panaroma Sun roof's sun shade motor elicits two major sounds when operating: the tonal sound and the white noises. Generally, the sound related to the sharpness contributes the most to the quality of motors' tonal sound. The primary purpose of this study was to set the loudness of the motor's objective tonal sound utilizing the masking effect by its white noises. To conduct this study, the sound made by the operating sun shade motor was categorized into two different subsets of masker and test tone to examine the masking threshold. Also, the shifts of masking threshold were observed with the varying masker loudness.

  • PDF

Comparison of the E-Test with Agar Dilution Susceptibility Test by Using Bacteroides fragilis (Bacteroides fragilis의 E-test와 한천 평판 희석법에 의한 항균제 감수성상의 비교)

  • Kim, Hee-Sun;Kim, Sung-Kwang;Cha, Hwa-Sun
    • Journal of Yeungnam Medical Science
    • /
    • v.10 no.1
    • /
    • pp.135-143
    • /
    • 1993
  • The susceptibilities of 45 clinical isolates of bacteroides frogilis to cefaclor, ciproflxacin and imipenem were determined by new method, E-test (AB Bidisk, Solna, Sweden) and were compared with those from conventional agar dilution method by using brain heart infusion, Mueller-Hinton and Wilkins Chalgren agar plates. And the susceptibility of 60 clinical isolates of Bacteroides fragilis group (B. fragilis 45 strains, B. distasonis 6 strains, B. ovatus 5 strains, B. thetaiotaomicron 4 strains) to 5 quinolones (ciprofloxacin, enoxacin, norfloxacin, ofloxacin, pefloxacin) were determined by in vitro agar dilution method. Compared with agar dilution MICs for B. fragilis 45 strains, 90.3% of E-test MICs were within ${\pm}$1 dilution of the agar dilutions, and 98.4% were within 2 dilutions. And there were little effect of different medium bases to determine MICs except Mueller-Hinton agar. On Mueller-Hinton agar, B. fragilis showed have or no growth activity. In vitro susceptibility of B. fragjlis group to quinolones, most of the test strains showed resistant patterns to quinolones except ofloxacin and there was little difference of susceptibility patterns between species of B. fragilis group.

  • PDF

A Repeated-dose 28-Day Oral Toxicity Test of Aconitum jaluense Extract in Sprague-Dawley Rats (초오 추출물의 Sprague-Dawley 랫드를 이용한 28일 반복 경구투여독성시험)

  • Lee, Jong Suk;Lee, Ji Sun;Park, Yeong-Chul;Choi, Sun Mi;Lee, Sanghun
    • YAKHAK HOEJI
    • /
    • v.58 no.1
    • /
    • pp.62-70
    • /
    • 2014
  • A 28-day repeated-dose oral toxicity test was performed to determine the no-observed-effect level (NOEL) and establish an optimum dose of the highly toxic Aconiti Ciliare Tuber (ACT) used as a folk remedy. Repeated oral doses of 1,250, 2,500, and 5,000 mg/kg/day of the hot water extract of ACT were administered to five male and five female Sprague-Dawley rats in each group for 4 weeks. The indicators for toxicity included results of examination of common symptoms and changes in weight and feed intake, eye test, urinalysis, hematological and serum biochemical analyses, and post-mortem weight measurement of organs, and visual inspections. All animals survived at the end of the experiment; in addition, we observed no specific test substance-mediated symptoms. We observed no test substance-mediated changes in body weight and feed intake. We observed statistically significant changes in male OB and pH levels (p<0.05). Further, the biochemical test showed statistically significant changes in the IP value of male rats and $CL^-$valueoffemalerats (p<0.05). However, all changes were within historical data. The post-mortem examinations showed no test substance-mediated changes. Moreover, statistically significant changes under the test conditions were confirmed to have been caused by factors other than the test substance. Thus, the maximum NOEL of ACT extract in rats was estimated to be 5,000 mg/kg/day.

A Note on Sudden Death Tests (sudden death 시험에 대한 고찰)

  • Seo, Sun-Keun
    • Journal of Applied Reliability
    • /
    • v.12 no.3
    • /
    • pp.139-152
    • /
    • 2012
  • Successive and simultaneous sudden death tests are compared with the complete and Type II censored samples in terms of expected test duration and Total Time on Test(TTT) subject to the same number of failures in order to maintain the equal statistical precision under Weibull lifetime distribution with known shape parameter. Also, two sudden death tests under a proposed cost model are discussed and a numerical example is provided to illustrate the use of the proposed cost model.

Verification of Hi9h Impedance Fault Relay through Low Voltage Power System Implementation (저압모의계통 구성을 통한 고저항지락사고 검출용 계전기의 실계통 적응성 검증)

  • Hong, Sun-Chun;Jang, Byung-Tae;Yoo, Heung-Jun
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1437-1439
    • /
    • 1999
  • This paper describes test method though low voltage power system implementation for high impedance fault relay test before its operation in real power system. Through this test, relay tested its function and algorithm. In this paper, we will provides test method using low voltage power system and its results.

  • PDF