• 제목/요약/키워드: SUN: UV

검색결과 696건 처리시간 0.032초

투과율 향상 UV 필터와 IR 모듈을 이용한 자외선-적외선(UV-IR) 카메라 개발 (Development of UV-IR Camera using IR Module and Improved UV Filter Transmittance)

  • 김영석;송길목;방선배;김종민;최명일;김우진
    • 조명전기설비학회논문지
    • /
    • 제26권12호
    • /
    • pp.37-43
    • /
    • 2012
  • UV-IR diagnostic technology is being used for predictive maintenance of high voltage equipment together with IR-thermography and ultrasonic devices. In this paper, the UV-IR camera design, fabrication, and perform a simple test to be take advantage of the diagnostic equipment. UV-IR camera developed a $6.4^{\circ}{\times}4.8^{\circ}$ of the field of view as a conventional camera to diagnose a wide range of slightly enlarged, and power equipment to measure the distance between the camera and the distance meter has been attached. In a distance of 5m with the UV-IR it is possible to detect partial discharge with a PD level of 2.5 pC and a RIV(Radio Influence Voltage) level of $3.6dB{\mu}V$.

Color Change and Tensile Properties of Wood Flour Reinforced Polypropylene Composites; Influence of Photostabilizers

  • Lee, Sun-Young
    • 한국응용과학기술학회지
    • /
    • 제26권2호
    • /
    • pp.171-178
    • /
    • 2009
  • A comparative analysis of the hindered amine light stabilizers (HALS) and UV abosrber (UVA) and their respective photostabilizing effect on wood plastic composites (WPCs) are reported in this study. The influence of accelerated weathering on the mechanical properties of the composites and the microscopic morphology of a degraded layer on the cross section and the surface were studied. UV absorbers were more efficient at preventing composite lightening than was UV stabilizer. The amount of whitening decreased with the increase of photostabilizers. With the addition of a UV absorber (Tinuvin360), the tensile modulus and strength of the composites increased slightly. However, the addition of a light stabilizer (Tinuvin770) and a UV absorber decreased the tensile modulus and strength of the composites. After 250 and 500 hr exposure, tensile modulus and strength of the un stabilized and stabilized composites decreased. The tensile strength of UV absorber (Chimassorb81)-stabilized composites was significantly greater than that of control and light stabilizer (Tinuvin770)- and UV absorber (Tinuvin360)-stabilized composites. UV absorber-stabilized samples showed less whitening and photodegradation than control and light stabilizer-stabilized samples.

광학렌즈 AR 코팅에 따른 폴리머애자에서의 방전 자외선 강도 비교 (Comparison of Discharge UV Intensity Due to AR Coating of Optic Lens on Polymer Insulator)

  • 김영석;송길목;방선배;김종민;최명일
    • 조명전기설비학회논문지
    • /
    • 제26권4호
    • /
    • pp.35-40
    • /
    • 2012
  • In this study, the ultraviolet (UV) intensity of polymer insulator was measured using the Anti-Reflective (AR) coating lens on the occurrence of corona discharge. The UV intensity was compared before and after the AR coating. Under the 200-260[nm] of UV lens, the reflection rate before AR coating was 7.5~5.5[%] with 85-89[%] of transmission rate. After AR coating, however, the reflection rate decreased to 1.3~1.22[%] with improved transmission (97.4~97.6[%]). Then, the UV intensity by distance was measured in the polymer insulator. According to the measurement, the UV intensity increased 6.5 times at 37.5[%] of Vm/Vbd with 5[m] of distance. As distance increased, the growth rate declined. As high voltage increased, in addition, AR coating was less effective due to the count error caused by the UV sensor pulse signal overlap. Therefore, it appears that it would be more effective to detect corona discharge with 5[m] or less of distance at diagnosis of power facilities by AR coating and UV sensor sensitivity.

마이크로프로세서를 사용한 UV/IR 불곶 감지기 (UV/IR flame detector using Microprocessor)

  • 박성진;임병현;임종연;김명원;윤길호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.215-218
    • /
    • 2001
  • A flame detector responds either to radiant energy visible to the human eye or outside the range of human vision. Such a detector is sensitive to glowing embers, coals, or flames which radiate energy of sufficient intensity and spectral quality to actuate the alarm. An infra-red detectors can respond to the total IR component of the flame alone or in combination with flame flicker in the frequency range of 5 to 30 Hz. A major problem in the use of infrared detectors receiving total IR radiation is the possible interference of solar radiation in the infrared region. When detectors are located in places shielded from the sun, such as vaults. filtering or shielding the unit from the sun's rays is unnecessary. In this study, we proposed method for redue a false alarm with using filtering & sensor technology for distinguish of causes of raise a false alarm and pure flame.

  • PDF

자외선 침투 방지용 직물의 개발 (A Study on UV-CUT Processing)

  • 김삼수;김성동;조규민
    • 한국염색가공학회지
    • /
    • 제6권3호
    • /
    • pp.52-59
    • /
    • 1994
  • Polyester, polyester/cotton blend, nylon and cotton fabrics were ultraviolet cutting finished with padding method or exhaustion method using several UV absorbers. The transmittance of ultraviolet ray in the textiles can be greatly depressed by the processing and it is expected that human skin can be kept safe from sun-burn or damages by ultraviolet ray.

  • PDF

자외선 차단행동에 따른 자외선차단의류 인지도와 구매태도 (UV-protective Clothing Awareness and Purchase Attitudes according to UV Protective Behavior)

  • 권수애;최종명;유정자;김정숙
    • 한국생활과학회지
    • /
    • 제18권4호
    • /
    • pp.903-912
    • /
    • 2009
  • The purpose of this study was to analyze potential effects of Koreans' ultraviolet risk awareness and appearance management on their UV protective behaviors in daily life and outdoor activities, and was to investigate in their awareness of UV-protective clothing and their purchase attitudes toward anti-UV protective clothing. To meet the above goals, we have surveyed a total of 262 participants(male and female) residing in Chungcheong province. Findings were as following: As a part of ultraviolet-protective behaviors, it was found that the respondents often relied on applying sun-block cream or shady place before exposition to sunlight. Particularly, it was notable that 30's or older group was more proactive in UV protective behaviors than younger group below 30 years old. There were significant correlations among the respondents' UV protective behaviors, their awareness of anti-UV clothing and their purchase attitudes to anti-UV clothing. Also, there were also significant correlations among their UV-protective means for outdoor activities. That is, more favorable awareness about anti-UV clothing they have is associated with their more active attitudes to purchasing anti-UV clothing and taking anti-sunlight behaviors. It was found that the number of respondents who used cosmetics for outdoor activities was more than that of respondents who used clothing to protect their body from ultraviolet ray. Hence, it will be necessary for follow-up studies to focus on the development and promotion of anti-UV clothing.

유기 자외선 흡수제의 조합과 용해도에 따른 자외선 차단 효율의 비교 및 안정성에 관한 연구 (Stability and Sun Protection Efficacy of Sunscreens Based on the Solubility and a Combination of Organic UV Absorbers)

  • 연제영;홍승덕;최세범;김타곤;이청희;이상길;표형배
    • 대한화장품학회지
    • /
    • 제41권3호
    • /
    • pp.189-199
    • /
    • 2015
  • 본 연구에서는 유기 자외선 흡수제와 오일들 간의 용해도에 따른 자외선 차단제의 안정성과 유기 자외선 흡수제의 조합에 따른 이들의 자외선 차단 효율 변화를 조사하여 보다 안정하고 효율이 높은 자외선 차단제품 개발에 도움이 되고자 하였다. 그 결과 오일의 종류, 농도 그리고 보관 조건에 따라서 유기 자외선 흡수제의 용해도 및 안정성이 다양하게 관찰되었으며, 이러한 현상은 에멀젼상에서도 자외선 차단지수에 영향을 나타냄을 확인하였다. 또한 유기 자외선 흡수제의 조합에 따라 다양한 자외선 흡광도가 측정되었으며, 조합 시 각각의 자체 흡광도보다 높은 시너지 효과를 나타내는 성분이 있었고, 특정 성분과의 조합 시에만 시너지 효과가 나타나는 경우도 있었다. 보관 조건에 따라서도 자외선 흡광도는 상이하게 측정되어, 자외선 차단 효율에 영향을 나타내는 다양한 변수가 있음을 확인할 수 있었다.

Disinfection and Reactivation of Microorganisms after UV Irradiation for Agricultural Water Reuse of Biofilter Effluent

  • Jung, Kwang-Wook;Yoon, Chun-G.;Hwang, Ha-Sun;Ham, Jong-Hwa
    • 한국농공학회지
    • /
    • 제45권7호
    • /
    • pp.94-106
    • /
    • 2003
  • A pilot study was performed to examine the feasibility of UV disinfection system and the reactivation of indicator microorganisms (TC, FC, E. coli) after UV irradiation for agricultural reuse of reclaimed water. Photoreactivation and dark repair enable UV-inactivated microorganisms to recover and may reduce the efficacy of UV inactivation, which might be drawbacks of the UV disinfection method. The effluent of biofilter for 16-unit apartment house was used as input to the UV disinfection system, and average SS and BOD concentration were 3.8 and 5.7 mg/L, respectively, and the mean level of total coliform was in the range of $1.0\times10^4$ MPN/100mL. UV disinfection was found to be effective and it reduced mean concentration of indicator microorganisms (total coliform, fecal coliform, and E. coli) to less than 100 MPN/100mL within 60s exposure using 17, 25, and 40W lamps. Two UV doses of 6 and 16 mW$\cdot$s/$\textrm{km}^2$ were applied and microorganisms reactivation was monitored under the dark, photoreactivating light, and solar irradiation. Microorganisms reactivation was observed in the UV dose of 6 mW$\cdot$s/$\textrm{km}^2$, and numbers increased up to 5% at the photoreactivating light and 1% at the dark. However, microorganisms were inactivated rather than reactivated at the solar radiation and numbers decreased to non-detectible level about below 2 MPN/100mL in 4 hours. In the case of 16 mW$\cdot$s/$\textrm{km}^2$, microorganism reactivation was not observed indicating that UV dose might affect the reactivation process such as photoreactivation and dark repair. Therefore, concerns associated with microorganism reactivation could be controlled by sufficient UV dose application. Agricultural reuse of reclaimed water might be even less concerned due to exposure to the solar irradiation that could further inactivate microorganisms. The pilot study result is encouraging, however, sanitary concern in water reuse is so critical that more comprehensive investigation is recommended.

한국인 피부의 자외선 감수성과 SPF 측정치에 미치는 인자의 영향 (UV Sensitivity of Korean Skin and The Effects of Factors affecting SPF Determination)

  • 이병곤
    • 대한화장품학회지
    • /
    • 제17권1호
    • /
    • pp.1-17
    • /
    • 1991
  • Multiport-600 Solar SimulatorR is one of the most recent and convenient in-strument for evaluation of sun protection factor(SPF). In this study, we examined the practicability of the SPF determining system using Multiport -600 and the effects of several factors-light sources, seasons and experimental animals-on the minimal erythema dose(MED) and SPF. We also tested the UV sensitivity according to the sites of Korean people, And the ultraviolet radiation reaching the earth's surface In Seoul have been observed for one year. As a result of this study, the determinig system for SPF using Multiport-600 was proved to be a good system in accuracy and time-saving. The biological activity of fluorescence UV lamp of PUVA-800R was significantly higher than natural light or solar simulator with Xe arc lamp, and the determined MED became lower in inverse proportion to room temperature rise. Skin sensitivity by ultraviolet adiation was hights. in order \circled1 back \circled2 inns, upper arm \circled3 outer upper arm \circled4 foream. We also observed that UV radiation intensity was highest at noon in july and 1 sun burn unit(MED) was 28 minutes at that time.

  • PDF