• Title/Summary/Keyword: STS304 Stainless Steel

Search Result 152, Processing Time 0.02 seconds

Prevention of Crevice Corrosion of STS 304 Stainless Steel by a Mg-alloy Galvanic Anode

  • Lim, U.J.;Yun, B.D.;Kim, J.J.
    • Corrosion Science and Technology
    • /
    • v.5 no.3
    • /
    • pp.90-93
    • /
    • 2006
  • Prevention of crevice corrosion was studied for STS 304 stainless steel using a Mg-alloy galvanic anode in solutions with various specific resistivity. The crevice corrosion and corrosion protection characteristics of the steel was investigated by the electrochemical polarization and galvanic corrosion tests. Experimental results show that the crevice corrosion of STS 304 stainless steel does not occur in solutions of high specific resistivity, but it occurs in solutions of low specific resistivity like in solutions with resistivities of 30, 60 and $115{\Omega}{\cdot}m$. With decreasing specific resistivity of the solution, the electrode potential of STS 304 stainless steel in the crevice is lowered. The potential of STS 304 stainless steel in the crevice after coupling is cathodically polarized more by decreasing specific resistivity indicating that the crevice corrosion of STS 304 stainless steel is prevented by the Mg-alloy galvanic anode.

Corrosion Resistance of Super Duplex Stainless Steel (수퍼 2상 스테인리스강의 부식 저항성에 관한 연구)

  • 강흥주;남기우;안석환;강창룡;도재윤;박인덕
    • Journal of Ocean Engineering and Technology
    • /
    • v.17 no.2
    • /
    • pp.40-46
    • /
    • 2003
  • The corrosion resistance of super duplex stainless steel on both its fibrous and dispersed phase was investigated. These structures consist of various volume fraction and distribution of austenite structure, which were obtained by changing the heat treatment temperature and cycle. The fibrous phase had higher austenite volume fraction than that of the dispersed phase at the same temperature. Corrosion resistance of super duplex stainless steel was evaluated through an immersion test and an impingement test, using 35% HCI and sea water, respectively. Super duplex stainless steel was compared with STS316L and STS304. The corrosion resistance of super duplex stainless steel was superior to ST316L and STS304. The dispersed phase of super duplex stainless steel was more stabilized than the fibrous phase in corrosion. The magnitude of corrosion rate was in order STS304, STS316L, fibrous phase of super duplex stainless steel and dispersed phase of super duplex stainless steel.

Comparative Study on Microstructures of Hot-rolled STS 304L/A516-70N and STS 316L/A516-70N Clad Plates (열간압연으로 제조된 STS 304L/A516-70N과 STS 316L/A516-70N 클래드재들의 미세조직에 대한 비교 연구)

  • Jin, Ju-Chan;Cho, Soochul;Sim, Hoseop;Lee, Young-Kook
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.34 no.4
    • /
    • pp.171-178
    • /
    • 2021
  • In the present study, we comparatively investigated the microstructures of two hot-rolled stainless steel clad plates; STS 304L - low carbon steel A516-70N and STS 316L - A516-70N. The STS 304L/A516-70N clad plate (Clad_304L_Ni) had a Ni-interlayer between stainless steel and carbon steel and a 90 ㎛ thick deformation band of unrecrystallized austenite grains on the stainless steel. The STS 316L/A516-70N clad plate (Clad_316L) had no interlayer and almost fully recrystallized austenite grains. Clad_304L_Ni exhibited the thinner a decarburized layer in carbon steel and a total carburized layer in stainless steel than Clad_316L. However, a severely carburized layer in stainless steel was thicker for Clad_304L_Ni than Clad_316L. Hardness profiles near the interface of clad plates matched well with microstructures at locations where the hardness values were measured.

Biocompatibility of STS304, 316 acupuncture needle (침의 재료인 스테인리스강 STS304 및 STS316의 생체적합성에 대한 고찰)

  • Hwang, Eui-Hyoung;Koo, Sung-Tae;Lee, In-Hwan;Lee, Min-Ho;Jang, In-Soo
    • Korean Journal of Acupuncture
    • /
    • v.24 no.1
    • /
    • pp.59-63
    • /
    • 2007
  • Objectives : To discuss the biocompatibility of stainless steel for using acupuncture needles. Results and Conclusions : It is widely assumed that stainless steel is one of the good corrosion-resistant materials and is safe for human body, Most of metal acupuncture needles are made of STS304 and STS316 in light of human body safety: STS304 in more differences between STS304 and STS316 in light of human body safety: STS304 is more vulnerable to oxidation than STS316. A variety of literature survey showed that although STS316 is more corrosion-resistant than STS304 there is no evidence supporting the hypothesis that STS304 has the potential danger to human body, Further study would be necessary to draw more decisive conclusion.

  • PDF

Study on the Damage Behavior of 304 Stainless Steel for Gas Boiler with Specific Resistance (비저항에 따른 가스보일러용 304스테인리스강재의 손상거동에 관한 연구)

  • Yun, Byoung-Du;Lim, Uh-Joh;Jeong, Ki-Cheol
    • Journal of the Korean Institute of Gas
    • /
    • v.9 no.4 s.29
    • /
    • pp.6-10
    • /
    • 2005
  • This paper was studied on the damage behavior of stainless steel (STS 304) for gas boiler with specific resistance. The electrochemical polarization test of STS304 for gas boiler was carried out. And the anodic polarization and damage aspect, such as pitting corrosion, was considered. With being low specific resistance, the passive current density of STS 304 increases, passive region and pitting potential is low. Also, the patting aspect of STS304 In specific resistance $74{\Omega}{\cdot}m$ water little appears, the pitting number increases and the damage behavior, such as pitting aspect, gradually grow bigger with being low specific resistance.

  • PDF

A Statistical. Properties of Tensile Behaviors of STS304 Stainless Steel at Elevated Temperature and the Acoustic Emission (STS304 스테인리스강의 고온 인장거동의 통계적 특성과 음향방출)

  • Kwak, Myung-Kyu;Kim, Seon-Jin
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.68-74
    • /
    • 2002
  • The tensile tests to identify the statistical tensile properties and the acoustic emission characteristics were conducted for STS304 stainless steel at $600^{\circ}C,\;700^{\circ}C$. From tensile tests performed by constant cross head speed controls with 1mm/min, rates at each elevated temperature, the scatters were observed in tensile strength, reduction of area, elongation and the acoustic emission parameters. The effect of temperature on the scatter of tensile behavior was larger at $700^{\circ}C$. The distributions of tensile properties was well followed in 3-parameter Weibull. The AE counts and energy of the $700^{\circ}C$ specimens were smaller than the $600^{\circ}C$.

  • PDF

A Proposal on the Stress-Strain Curve of Stainless Steel STS 304 (STS 304 스테인리스강의 응력도-변형도 곡선에 관한 제안)

  • Shin, Tae Song
    • Journal of Korean Society of Steel Construction
    • /
    • v.18 no.2
    • /
    • pp.271-278
    • /
    • 2006
  • This paper is to investigate into the stress-strain curves for austenite stainless steel STS 304 over the full strain range. The Ramberg-Osgood expression is useful up to the beyond the0.2% proof stress in the ultimate state. The Rasmussen curve has developed for stresses beyond 0.2% proof stress, based on the Ramberg-Osgood concept. These expressed curves don't good agree with the test results. It is here proposed the based on the analysis of the test results better curve.

Study on the Prevention of Crevice Corrosion for a Stainless Steel Heat Exchanger (스테인리스강 열교환기의 틈부식 방지에 관한 연구)

  • LIM, U-Joh;YUN, Byoung-Du
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.17 no.1
    • /
    • pp.106-114
    • /
    • 2005
  • This paper is a study on the prevention of crevice corrosion for a stainless steel heat exchanger in various pH solutions and with Cl ion concentrations. The electrochemical polarization test and crevice corrosion test of STS 304 for a heat exchanger were carried out. The crevice corrosion aspect, a passive behavior, crevice corrosion behavior, and corrosion protection characteristics of STS 304 using Al-alloy and Mg-alloy galvanic anode were considered. The main results are as follows: 1. The crevice corrosion of STS 304 occurs in the crevice and this corrosion increases pitting according to depth direction. On the other hand, the exterior crevice becomes passive. 2. With changing from a neutral to acid environment and increasing Cl ion concentration, the pitting potential of STS 304 lowers, and thus the crevice corrosion of STS 304 is sensitive. 3. The cathodic protection potential of STS 304 in the crevice is cathodically polarized by increasing Cl ion concentration. Therefore, an Al-alloy galvanic anode is more suitable than a Mg-alloy galvanic anode to protect the crevice corrosion of STS 304.

Effect of Heat Treatment Characteristic on the Gas Nitriding of Stainless Steels (스테인리스강의 가스질화에 미치는 열처리 조건의 영향에 관한 연구)

  • Kim, H.G.;Hwang, G.S.;Sun, C.G.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.16 no.2
    • /
    • pp.78-82
    • /
    • 2003
  • Nitrided compound layer and diffusion layer structure were observed by SEM. The compound layer and the constituent of nitrided surface of STS 304, STS 316, STS 410 and SACM 645 steel were analysed using EMPA and XRD respectively. The depth of nitriding layer that is obtained from similar nitriding condition decrease in the order of SACM 645 > STS 410 > STS 316 > STS 304. Result of phase transformation of the nitrided at $550^{\circ}C$ by XRD analysis were as follows; The austenitic stainless steel was mainly consist of $Cr_2N$ accompanying with $Fe_4N$ and $Fe_{2-3}N$ phase and martensitic stainless steel was mainly consist of present $Fe_{2-3}N+Cr_2N$ phase, but SACM 645 steel was $Fe_{2-3}N$ phase present only.

A Study on the Fatigue Fracture Behavior of Heat Cycle of Welded Dissimilar (이종금속 용접재의 열 사이클에 따른 피로파괴 거동에 관한 연구)

  • 신근하;김진덕
    • Journal of the Korean Society of Safety
    • /
    • v.8 no.1
    • /
    • pp.59-63
    • /
    • 1993
  • It is very difficult to find not only optimized welding condition but also fatigue characteristics of the dissimilar weld. In this study. Low carbon steel (SS41) and austenitic stainless steel (STS304) were welded by GTAW welding with STS309 stainless wire rod and Single Edge Notch specimens were used for the examination of fatigue behavior on welding heat cycle. The fatigue crack growth rate in HAZ of SS41 was the highest. The second was in STS304 bond line and the lowest was in HAS of STS304.

  • PDF