• 제목/요약/키워드: STL(Stereolithography)

검색결과 39건 처리시간 0.029초

Repeatability and reproducibility of individual abutment impression, assessed with a blue light scanner

  • Jeon, Jin-Hun;Kim, Dong-Yeon;Lee, Jae-Jun;Kim, Ji-Hwan;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권3호
    • /
    • pp.214-218
    • /
    • 2016
  • PURPOSE. We assessed the repeatability and reproducibility of abutment teeth dental impressions, digitized with a blue light scanner, by comparing the discrepancies in repeatability and reproducibility values for different types of abutment teeth. MATERIALS AND METHODS. To evaluate repeatability, impressions of the canine, first premolar, and first molar, prepared for ceramic crowns, were repeatedly scanned to acquire 5 sets of 3-dimensional data via stereolithography (STL) files. Point clouds were compared and the error sizes were measured (n=10, per type). To evaluate reproducibility, the impressions were rotated by $10-20^{\circ}$ on the table and scanned. These data were compared to the first STL data and the error sizes were measured (n=5, per type). One-way analysis of variance was used to assess the repeatability and reproducibility of the 3 types of teeth, and Tukey honest significant differences (HSD) multiple comparison test was used for post hoc comparisons (${\alpha}=.05$). RESULTS. The differences with regard to repeatability were 4.5, 2.7, and $3.1{\mu}m$ for the canine, premolar, and molar, indicating the poorest repeatability for the canine (P<.001). For reproducibility, the differences were 6.6, 5.8, and $11.0{\mu}m$ indicating the poorest reproducibility for the molar (P=.007). CONCLUSION. Our results indicated that impressions of individual abutment teeth, digitized with a blue light scanner, had good repeatability and reproducibility.

An Efficient Method for Aneurysm Volume Quantification Applicable in Any Shape and Modalities

  • Chung, Jaewoo;Ko, Jung Ho
    • Journal of Korean Neurosurgical Society
    • /
    • 제64권4호
    • /
    • pp.514-523
    • /
    • 2021
  • Objective : Aneurysm volume quantification (AVQ) using the equation of ellipsoid volume is widely used although it is inaccurate. Furthermore, AVQ with 3-dimensional (3D) rendered data has limitations in general use. A novel universal method for AVQ is introduced for any diagnostic modality and application to any shape of aneurysms. Methods : Relevant AVQ studies published from January 1997 to June 2019 were identified to determine common methods of AVQ. The basic idea is to eliminate the normal artery volume from 3D model with the aneurysm. After Digital Imaging and Communications in Medicine (DICOM) data is converted and exported to stereolithography (STL) file format, the 3D STL model is modified to remove the aneurysm and the volume difference between the 3D model with/without the aneurysm is defined as the aneurysm volume. Fifty randomly selected aneurysms from DICOM database were used to validate the different AVQ methods. Results : We reviewed and categorized AVQ methods in 121 studies. Approximately 60% used the ellipsoid method, while 24% used the 3D model. For 50 randomly selected aneurysms, volumes were measured using 3D Slicer, RadiAnt, and ellipsoid method. Using 3D Slicer as the reference, the ratios of mean difference to mean volume obtained by RadiAnt and ellipsoid method were -1.21±7.46% and 4.04±30.54%, respectively. The deviations between RadiAnt and 3D Slicer were small despite of aneurysm shapes, but those of ellipsoid method and 3D Slicer were large. Conclusion : In spite of inaccuracy, ellipsoid method is still mostly used. We propose a novel universal method for AVQ that is valid, low cost, and easy to use.

CAD-CAM을 이용하여 디자인한 금관의 치과 직업군에 따른 형태 비교 (Comparison of crown designs of different dental occupational groups, using CAD-CAM)

  • 김태현;김종은;이아름;박영범
    • 대한치과보철학회지
    • /
    • 제54권3호
    • /
    • pp.234-238
    • /
    • 2016
  • 목적: 최근 치과 영역에서 CAD-CAM (computer aided design-computer aided manufacturer) 시스템의 이용과 디자인 소프트웨어가 늘어남에 따라 쉽고 빠른 수복물의 디자인이 가능해졌다. 과거에는 치과 기공사의 wax up 기술의 숙련도에 따라 금관의 외형이 결정 되었으나, CAD-CAM 시스템에서는 디자인 소프트웨어에 대한 숙련도가 더 중요한 요인이 되어가고 있다. 이에 치과 기공사와 치과의사간의 결과물의 차이를 알아보고자 한다. 재료 및 방법: 대합치와 인접치가 양호한 환자의 하악 우측 제1대구치를 금관 지대치 형성 한 후 polyether로 인상채득 하였다. 인상재에 초경석고를 이용하여 모형을 제작 하였으며, Trios 구강내 스캐너를 이용하여 STL (stereolithography) 파일을 추출하였다. 3shape dental designer 상에서 5년 이상 경력의 치과 기공사 1명, 2년 이하 경력의 치과 기공사 3명, 4명의 보철과 1년차 전공의가 동일한 STL 파일을 이용하여 금관을 디자인 하였다. CAD-CAM 시스템 경력이 가장 오래된 기공사의 디자인을 기준으로 하여 치과 기공사 그룹 3명(group DT)과 1년차 전공의 그룹 4명(group RT) 의 금관 외형을 비교하였다. 디자인된 금관의 근원심폭, 협설폭, 높이, 교두간 거리, 대합치와의 접촉점의 수를 측정, 비교 하였다. 독립표본 t검정을 시행하여 그룹간의 차이를 비교하였고, 대합치와의 접촉점의 수는 Wilcoxon signed-rank test 를 이용하였다. 결과: 정규성 검정 결과 근원심폭, 협설폭, 높이, 교두간 거리는 정규분포를 보였다. Group DT와 group RT의 금관 디자인상에서 근원심폭, 협설폭, 높이, 교두간 거리에서 통계적으로 유의할만한 차이가 없었다. 대합치와의 접촉점 수는 정규분포를 보이지 않았으며, wilcoxon signed-rank test 결과 통계적으로 유의한 차이를 보이지 않았다. 결론: 금관의 외형의 크기에 있어서는 group DT와 group RT 사이에 통계학적으로 유의할만한 차이가 없었지만 수치화하기 어려운 금관의 해부학적 형태나 주변 치아와의 형태적 유사성 등은 차이가 있었다. 디자인 소프트웨어에 대한 숙련도가 높아진다면 각 술자가 가지고 있는 교합에 대한 개념을 더 구현하기 쉬울 것이다.

Application of 3D Simulation Surgery to Orthognathic Aurgery : A Preliminary Case Study

  • Lim, Jung-Hwan;Kim, Hyun-Young;Jung, Young-Soo;Jung, Hwi-Dong
    • Journal of International Society for Simulation Surgery
    • /
    • 제1권1호
    • /
    • pp.23-26
    • /
    • 2014
  • The aim of this report is to evaluate accuracy using3D surgical simulationand digitally printedwafer in orthognathic surgery. 22-year-old female was diagnosed with mandibular prognathism and apertognathia based on 3D diagnosis using CT. Digital dentition images were taken by laser scanning from dental cast, and each STL images were integrated into one virtual skull using simulation software. Digitalized intermediate wafer was manufactured using CAD/CAM software and 3D printer, and used to move maxillary segment in real patient. Constructed virtual skull from 1 month postoperative CT scan was superimposedinto simulated virtual model to reveal accuracy. Almost maxillo-mandibular landmarks were placed in simulated position within 1 mm differences except right coronoid process. Thus 3D diagnosis, surgical simulation, and digitalized wafer could be useful method to orthognathic surgery in terms of accuracy.

A study on the machining accuracy of dental digital method focusing on dental inlay

  • Bae, Eun-Jeong;Jeong, Il-Do;Kim, Woong-Chul;Kim, Ji-Hwan
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권4호
    • /
    • pp.321-327
    • /
    • 2018
  • PURPOSE. The purpose of this study was to compare the cutting method and the lamination method to investigate whether the CAD data of the proposed inlay shape are machined correctly. MATERIALS AND METHODS. The Mesial-Occlusal shape of the inlay was modeled by changing the stereolithography (STL). Each group used SLS (metal powder) or SLA (photocurable resin) in the additive method, and wax or zirconia in the subtractive method (n=10 per group, total n=40). Three-dimensional (3D) analysis program (Geomagic Control X inspection software; 3D systems) was used for the alignment and analysis. The root mean square (RMS) in the 2D plane state was measured within $50{\mu}m$ radius of eight comparison measuring points (CMP). Differences were analyzed using one-way analysis of variance and post-hoc Tukey's test were used (${\alpha}=.05$). RESULTS. There was a significant difference in RMS only in SLA and SLS of 2D section (P<.05). In CMP mean, CMP 4 ($-5.3{\pm}46.7{\mu}m$) had a value closest to 0, while CMP 6 ($20.1{\pm}42.4{\mu}m$) and CMP 1 ($-89.2{\pm}61.4{\mu}m$) had the greatest positive value and the greatest negative value, respectively. CONCLUSION. Since the errors obtained from the study do not exceed the clinically acceptable values, the lamination method and the cutting method can be used clinically.

열 가압 방식을 사용하여 제작된 인레이 세라믹 수복물의 적합도 평가 (Assessment of inlay ceramic restorations manufactured using the hot-pressing method)

  • 이범일;유승규;유승민;박동인;김지환
    • 대한치과기공학회지
    • /
    • 제42권1호
    • /
    • pp.9-16
    • /
    • 2020
  • Purpose: The purpose of this study was to compare the marginal and internal fit of lithium disilicate ceramic inlay produced by heat pressing that inlay pattern made by subtractive manufacturing and additive manufacturing method. Methods: A mandibular lower first molar that mesial occlusal cavity (MO cavity) die was prepared. After fabricating an epoxy resin model using a silicone impression material, epoxy resin die was scanned with a dental model scanner to design an MO cavity inlay. The designed STL pile was used to fabricate wax patterns and resin patterns, and then lithium disilicate ceramic inlays were fabricated using hot-press method. For the measurement of the marginal and internal gap of the lithium disilicate, silicone replica method was applied, and gap was measured through an optical microscope (x 80). Data were tested for significant differences using the Mann-Whitney Utest. Results: The marginal fit was 103.56±9.92㎛ in the MIL-IN group and 81.57±9.33㎛ in the SLA-IN group, with a significant difference found between the two groups (p<0.05). The internal fit was 120.99±17.52㎛ in the MIL-IN group and 99.18±6.65㎛ in the SLA-IN group, with a significant difference found between the two groups (p<0.05). Conclusion: It is clinically more appropriate to apply the additive manufacturing than subtractive manufacturing method in producing lithium disilicate inlay using CAD/CAM system.

Use of measuring gauges for in vivo accuracy analysis of intraoral scanners: a pilot study

  • Iturrate, Mikel;Amezua, Xabier;Garikano, Xabier;Solaberrieta, Eneko
    • The Journal of Advanced Prosthodontics
    • /
    • 제13권4호
    • /
    • pp.191-204
    • /
    • 2021
  • PURPOSE. The purpose of this study is to present a methodology to evaluate the accuracy of intraoral scanners (IOS) used in vivo. MATERIALS AND METHODS. A specific feature-based gauge was designed, manufactured, and measured in a coordinate measuring machine (CMM), obtaining reference distances and angles. Then, 10 scans were taken by an IOS with the gauge in the patient's mouth and from the obtained stereolithography (STL) files, a total of 40 distances and 150 angles were measured and compared with the gauge's reference values. In order to provide a comparison, there were defined distance and angle groups in accordance with the increasing scanning area: from a short span area to a complete-arch scanning extension. Data was analyzed using software for statistical analysis. RESULTS. Deviations in measured distances showed that accuracy worsened as the scanning area increased: trueness varied from 0.018 ± 0.021 mm in a distance equivalent to the space spanning a four-unit bridge to 0.106 ± 0.08 mm in a space equivalent to a complete arch. Precision ranged from 0.015 ± 0.03 mm to 0.077 ± 0.073 mm in the same two areas. When analyzing angles, deviations did not show such a worsening pattern. In addition, deviations in angle measurement values were low and there were no calculated significant differences among angle groups. CONCLUSION. Currently, there is no standardized procedure to assess the accuracy of IOS in vivo, and the results show that the proposed methodology can contribute to this purpose. The deviations measured in the study show a worsening accuracy when increasing the length of the scanning area.

위팔뼈 의료용 디지털 영상 및 통신 표준 영상을 이용한 5축 가공기술의 융합적 연구 (A Convergence Study on the 5-axis Machining Technology using the DICOM Image of the Humerus Bone)

  • 윤재호;지태정;윤준;김형균
    • 한국융합학회논문지
    • /
    • 제8권11호
    • /
    • pp.115-121
    • /
    • 2017
  • 의료용 디지털 영상 및 통신 표준과 5축 가공기술의 융합적 연구를 통하여 맞춤형 인공관절의 기초적 지식을 얻고자 하였다. 연구방법으로 의료영상의 위팔뼈에 대해 3차원 모델링을 생성하고 케미컬우드 소재로 형상을 가공하여 해부학적 특징과 모델링 가공 연산시간을 비교하였다. 그 결과 스테레오리소그래피 모델링이 아이제스 모델링에 비해 중삭 2배, 정삭 10배 정도로 시간이 많이 소요되었다. 5축 가공된 위팔뼈는 해부목, 큰돌기, 작은돌기, 결절사이 고랑의 해부학적 구조가 3차원 의료영상과 동일한 특징으로 나타났다. 이와 같이 위팔뼈의 외과목 언더컷 등 다양한 형태의 구조가 5축으로 가공되는 융합적 가공 기술들은 인체의 정밀한 모형을 추구하는 맞춤형 관절 제작 시 향후 적용 가능성이 높음을 알 수 있었다.

제작방법에 따른 임시 수복용 레진의 마모저항성에 관한 연구 (In vitro evaluation of the wear resistance of provisional resin materials fabricated by different methods)

  • 안종주;허중보;최재원
    • 대한치과보철학회지
    • /
    • 제57권2호
    • /
    • pp.110-117
    • /
    • 2019
  • 목적: 본 연구의 목적은 적층 가공(additive manufacturing)법, 절삭 가공(subtractive manufacturing)법, 전통적인 방법에 따른 임시 수복용 레진의 마모 저항성을 조사하는 것이다. 재료 및 방법: 제작방법에 따라 4개의 군으로 나누었으며, 각 군은 전용의 임시 수복용 레진을 사용하였다: S3P군, Stereolithography apparatus (SLA) 3D 프린터 및 전용의 광경화성 수지로 제작한 군; D3P군, Digital Light Processing (DLP) 3D 프린터 및 전용의 광경화성 수지로 제작한 군; MIL군, Milling machine 및 밀링용 레진 블록으로 제작한 군; CON군, 전통적인 방법 및 자가중합형 레진으로 제작한 군. 한편, 3D 프린팅된 레진 시편을 제작함에 있어 적층 각도와 층 두께를 각각 $0^{\circ}$$100{\mu}m$로 설정하였다. 구강내 환경을 재현하기 위하여 열순환 처리와 수평, 수직운동이 가능한 2축 chewing simulator를 사용하였으며, 하부에는 한쪽면이 편평하게 제작된 임시 수복용 레진을, 상부에는 끝이 3 mm 직경을 가지는 원뿔형의 steatite를 고정하여 마모시험 진행하였다(5 kg, 30,000회, 0.8 Hz, $5^{\circ}C/55^{\circ}C$). 임시 수복용 레진의 마모량은 마모 전후의 Standard Triangulated Language (STL) 파일과 전용의 CAD software를 이용하여 부피를 계산하였고, 주사전자현미경으로 마모 양상을 비교하였다. 결과: S3P군, D3P군, MIL군의 마모량은 CON군보다 유의하게 작았으며 (P < .05), S3P군, D3P군, MIL군 사이에는 통계학적으로 유의한 차이가 없었다 (P > .05). 주사전자현미경으로 마모면을 관찰한 결과, S3P군과 D3P군에서는 대합치의 운동 방향에 대해 수직적으로 갈라진 흔적이 발견되었다. MIL군에서는 전반적으로 균일한 마모면이 보인 반면, CON군에서는 대합치 운동 방향으로의 뚜렷한 마모 흔적과 다수의 기포가 관찰되었다. 결론: 본 연구의 한계 내에서, 3D 프린팅된 임시 수복용 레진은 치과용으로서 적절한 마모저항성을 보였다.