• Title/Summary/Keyword: SS (suspended solid)

Search Result 166, Processing Time 0.027 seconds

The treatment of coolant wastewater of rolling plate process by High Gradient Magnetic Separation

  • Kim, Tae-Hyung;Ha, Dong-Woo;Kwon, Jun-Mo;Sohn, Myung-Hwan;Baik, Seung-Kyu;Oh, Sang-Soo;Ko, Rock-Kil;Kim, Ho-Sup;Kim, Young-Hun;Park, Seong-Kuk
    • Progress in Superconductivity and Cryogenics
    • /
    • v.11 no.4
    • /
    • pp.8-11
    • /
    • 2009
  • This study introduced wastewater treatment method by High Gradient Magnetic Separation (HGMS). HGMS treatment was high efficient method for various industrial wastewaters. The system is currently research state, but we have surveyed commercialize the technology for industry. In rolling plate process, coolant wastewater was recycled by sedimentation and sand filter system. It needs several large reservoirs and long time to remove suspended solid (SS) like metal fines and iron oxide in hot rolling plate making process. If removing rate of suspended solid in rolling coolant wastewater is improved by using HGMS system, the productivity of working process can be increased and the area of reservoir can be reduced. We manufactured high temperature superconducting HGMS system that had a purpose to treatment of coolant wastewater in rolling plate process. We fabricated the prototypes of magnetic matrix filter consisting of stainless steel 430 mesh, which is a core component in the magnetic separation system, In our basic preliminary experiment using HGMS system, it has been clear that the fine paramagnetic particles in the coolant wastewater obtained from rolling plate process of POSCO can be separated with high efficiency.

Effect of Molecular Weight of Chitosan on Flocculation of Suspended Solids in Rhodamine 6G-Sodium Dodecyl Sulfate System (키토산 분자량에 따른 Rhodamine 6G-Sodium Dodecyl Sulfate계의 응집효과에 관한 연구)

  • Kim, Sung Hyun;Nah, Jae Woon;Oh, Jeong Sun;Song, Ki Dong
    • Journal of the Korean Chemical Society
    • /
    • v.42 no.6
    • /
    • pp.672-678
    • /
    • 1998
  • Chitin was extracted from crab shell of Portuns triberculatus and deacethylated to yield chitosan with various molecular weights. The absorption and the fluorescence spectra of Rhodamine 6G(Rh 6G)-sodium dodecyl sulfate(SDS) and Rh 6G-chitosan systems were obtained. From the spectra, we observed that the absorption and the fluorescence intensity of Rh 6G-SDS system decreased when S/D(the concentration of SDS to that of Rh 6G ratio) was below or at 32, while they increased when S/D was above 32. From the suspended solid(SS) removal rate and the transmittance of Rh 6G-SDS-chitosan system, we found that when S/D ratio was 32 its flocculating behaviour was much stronger than Rh 6G-SDS system. As the concentration and the molecular weight of chitosan increased, we also found that S/D range was extended from 32 to 100. With increasing the molecular weight of chitosan, the SS removal rate increased around pH 2~9 but decreased remarkably at pH>12.

  • PDF

Suspended Solid Removal using Capillary-syphon Phenomenon -Evaluation of Possibility for Adapting Water Supply Process- (모세관 사이폰 현상을 이용한 부유물질 제거 - 상수처리공정 적용 가능성 평가 -)

  • Park, Dong-keun;Kim, Su-jung;Lee, Hae-goon;Jang, Jung-kuk;Han, Kee-baek;Kim, Chang-won
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.7
    • /
    • pp.1285-1294
    • /
    • 2000
  • In this study, we investigated the possibility of the elimination of suspended solid and the factors affecting effluent water quality, and the amount of treated water, using the SS removal equipment adapted capillary-syphon phenomenon. Treated water quantity decreased as the accumulation time and the increase of head of capillary syphon, whereas the effluent water quality was improved. At coagulant dosage 0, 0.45, $1.82mg/{\ell}$ (as $Al^{+3}$) and limiting flux $107{\ell}/m/day$. turbidity of treated water was 2, 1, 0.5 NTU in each case. During operating period 15~17 days, the amount of washing water was just used 0.5~0.7% of the amount of treating water. So it is expected that coagulation & sedimentation and rapid filtration process can be replaced with the SS removal equipment adapted capillary-syphon phenomenon in water purification process.

  • PDF

Modeling of Discharge Characteristics of Combined Sewer Overflows(CSOs) from a Small Urban Watershed in Daejeon City (대전광역시 소유역에서 합류식 하수관거 월류수(CSOs)의 배출특성 모델링)

  • Kim, Jeong-Kon;Ko, Ick-Hwan
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.6
    • /
    • pp.654-660
    • /
    • 2006
  • This study investigated the discharge characteristics of combined sewer overflows(CSOs) at a small watershed located in the Ojeong-cheon area of the Daejeon-cheon, Daejeon City. The long-term variations of discharges, water quality, and SS loads from 2001 to 2004 were simulated using SWMM. The simulation results indicated that suspended solid(SS) loads during the rainy seasons(July${\sim}$August) were highest throughout the whole year, but not substantially higher than those during the dry seasons. This result is due to the fact that contaminants do not buildup significantly because of frequent rainfall events during the wet seasons. It was estimated that about 9.3% of SS was discharged to the receiving body the during dry seasons while 90.7% during the rainy seasons. Further analysis showed that during the wet seasons SS loads discharged at the site as CSOs and at the wastewater treatment plant without treatment were 38% and 62%, respectively.

Analysis of the sludge thickening characteristics in the thickener using CFD Model (CFD를 이용한 농축조 슬러지의 유출흐름특성 해석)

  • Park, No-Suk;Moon, Yong-Taik;Kim, Byung-Goon;Kim, Hong-Suck
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.5
    • /
    • pp.777-782
    • /
    • 2011
  • The residual treatment facilities in WTP(water treatment plant) play an important role in solid-liquid separation. At present, it is difficult to solve problems related with thickening and dewatering of WTP sludge, and discharging waste water to river. The quantity of residuals generated from water treatment plants depends upon the raw water quality, dosage of chemicals used, performance of the treatment process, method of sludge removal, efficiency of sedimentation, and backwashing frequency. Sludge production by the physical separation of SS(Suspended Solid) occurs under quiescent conditions in the primary clarifier, where SSs are allowed to settle and to consolidate on the clarifier bottom. Raw primary sludge results when the settled solids are hydraulically removed from the tank. In this study, Drawing characteristics of the sludge thickening in the thickener of Water Treatment Plants was simulated by Using CFD(Computational Fluid Dynamics.

Advanced Wastewater Treatment Using Biofilter System with Floating Media under Alternative Flow (유로변경식 부상여재 생물여과시스템을 이용한 하수고도처리)

  • Ryu, Hong-Duck;Lee, Jeong-Hun;Lee, Sang-Ill
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.2
    • /
    • pp.250-257
    • /
    • 2006
  • The objective of this study is to propose an alternative process for the small sewage treatment plants in rural communities. A biofilter has been used for biological wastewater treatment, which is becoming the alternative to the conventional activated sludge system. The proposed process used in this study, which is packed with floating media (i.e. expanded polystylene), has advantages of biofilter system and alternative flow system and they are incorporated into one process. Pilot and bench scale studies were performed using domestic wastewater. In the results of pilot plant study, it was observed that the stable effluent water quality was achieved and it met the present effluent criteria of suspended solid (SS), organic matters, T-N and T-P. In the study for determination of the cycle of backwashing, it was observed that the cycle of backwashing depended on BOD loading rates of influents. In the BOD loading rates of $0.5kg\;BOD/m^3{\cdot}day$ and $1.0kg\;BOD/m^3{\cdot}day$, the backwashing cycle of 28 hour and 16 hour were needed, respectively. The optimum backwashing time was 120~80 seconds at the media expansion rate of 50%. In the removal of SS, organic matters, T-N and T-P, SS removal was rather achieved by physical filtration than biological mechanism and the removal of organic matters except for SS, T-N and T-P were mainly rather achieved by biological mechanism than physical filtration. In bench-scale study, the effects of recirculation rate was investigated on removal of SS, TCOD, T-N and T-P. It was observed that the recirculation made removal efficiencies of SS, TCOD, T-N and T-P increased. Especially, in T-N removal, the increase of T-N removal efficiency of 40% was observed in the reicirculation rate of 1Q compared with 0Q.

Calibration of Water Quality Parameters in SWAT Considering Continuous Drought Periods 2014~2015 (2014~2015 연속가뭄을 고려한 SWAT 수질 매개변수 보정)

  • Kim, Da Rae;Lee, Ji Wan;Jung, Chung Gil;Kim, Seong Joon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.60 no.1
    • /
    • pp.11-20
    • /
    • 2018
  • This study is to calibrate the SWAT (Soil and Water Assessment Tool) water quality of SS (Suspended Solid), T-P (Total Phosphorus), and T-N (Total Nitrogen) by focusing on 2014~2015 drought periods and identify the important parameters. For Gongdo watershed ($366.5km^2$), the SWAT was calibrated for 2 cases of 2002~2006 normal year focusing calibration and 2014~2015 drought focusing calibration respectively. The parameters of N_UPDIS (Nitrogen uptake distribution parameter) and CMN (Rate factor for humus mineralization of active organic nutrients) played important roles for T-N calibration during drought periods. The SWAT SS, T-N, and T-P average $R^2$ (Coefficient of determination) results by focusing on 2014~2015 drought periods calibration showed 0.71, 0.65 and 0.62 while 2002~2006 normal year focusing calibration showed 0.63, 0.58 and 0.50 respectively. Also SWAT SS, T-N, and T-P model efficiency NSE (Nash-Sutcliffe efficiency) results by focusing on drought period (2014~2015) calibrated showed 0.76, 0.77, 0.87 respectively. Even though the SS, T-P parameters were unchanged during the calibration, the SS and T-P results were improved by the hydrological parameters (SCS-CN, SOL_K, SLSOIL) during the drought periods. The SWAT water quality calibration needs to be considered for the movement of SS and nutrients transport especially focusing on the drought characteristics.

The hydrologic flux of SS, TN and TP in Nakdong River Basin (낙동강 유역 SS, TN, TP 수문학적 플럭스)

  • Lee, Ayeon;Choi, Daegyu;Kim, Tae-Woong;Kim, Sangdan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.6B
    • /
    • pp.551-560
    • /
    • 2010
  • This study presents the export of constituent transport loads through a river system. The proposed constituent transport load estimating procedure can be operated with the on-going Korean TMDL monitoring system. This study firstly discusses the use of a hydrologic simulation model (TANK) to estimate stream-flow for the 40 sub-catchments. Model parameters are estimated from 8-days intervals flow data which has been monitored by NIER since 2004. Constituent transport loads are estimated with the 7-parameter log linear model whose parameters are estimated by the minimum variance unbiased estimator. Results from Nakdong river basin reveals that the proposed procedure provides satisfactory TN, TP and SS transport load estimates. As an application, a representative load duration curve is derived to represent the overall hydrologic flux of TN, TP and SS at Nakdong river basin.

Verification of the Filter Media Applied to Filter Type Facility Considering the Treatment Efficiency Factor (여과형 시설에 적용되는 여재의 처리효율 영향인자를 고려한 실증화 평가)

  • Kim, Taeyoon;Lee, Junebae;Lee, Dongwoo;Shin, Hyunsuk;Kim, Hyunchul;Kwon, Soonchul
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.5
    • /
    • pp.572-579
    • /
    • 2017
  • Increased impervious surface caused by rapid urbanization serves to produce the discharge of non-point source pollutants such as total suspended solid (TSS). There exist various methods of removing TSS, including a filtration process using granular media (a well-known method to be practically used after the consideration of removal efficiency, clogging, and backwashing efficiency). To determine the TSS removal capability of the filter, we initially performed lab-scale experiments which assessed flow rates, influent concentrations, permeability co-efficients, the particular shapes of suspended solids and potential clogging, and also evaluated TSS removal efficiency when applied to filtration facility in a pilot-scale. In low filtration flux condition, the removal efficiency of suspended solids was more than 95 %, while decreased to 83% in high filtration flux. Regarding the clogging aspect of the experiment, total cumulative solids were loaded up to $19.15kg/m^2$, and TSS removal efficiency was noted to commence to decrease when the loaded solids exceeded $9.0kg/m^2$. It was also noted, however, that superior efficiency was maintained for six hours. In addition, for pilot-scale experiment, the removal efficiency was still high enough (83.4 %) for the solid concentration of 140 ~ 343 mg SS/L and after backwashing, head loss was recovered to 92 ~ 95 % during two hour filtration. With these results, It was confirmed that lifetime of the filter applied to the test was prolonged due to the high treatment efficiency and good backwashing efficiency for the cumulative solids load.

Characteristics of Wastewater Treatment in Applying RBC Modified Dephanox Process (회전원판법을 적용한 Modified Dephanox 공정의 하수처리특성)

  • Kang, Min-Koo;Kim, Keum-Yong;Ryu, Hong-Duck;Lee, Sang-Ill
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.5
    • /
    • pp.477-486
    • /
    • 2010
  • This study was performed with the object in which it improves the nitrification by using RBC, that is one of the biological waste water treatment process. By applying the Modified Dephanox process to RBC in this research in order to evaluate the improvement of the nitrification by RBC a research was conducted. There is the most conspicuous feature of the process of using RBC. it is that the nitrification can be smoothly performed even if the suspended solid of the high concentration as the interference factor in the nitrification tank is flowed in. Moreover, as a result of experiment, TCOD removal efficiency of the process showed up more than about 90%. when influent TCOD loading rate was 0.04~0.1 kg / $day{\cdot}m^3$. and T-N removal efficiency is high at about 75% in spite of the process operating of the laboratory scale was observed. Also, As increasing influent ${PO_4}^{3-}$-P, T-P loading rate, ${PO_4}^{3-}$-P, T-P removal efficiency was increased. Finally, it was elucidated that the utilization of RBC in external nitrification system resulted in not only high nitrification performance but also stable system operation by minimizing inhibitory effect of overflowed suspended solid (SS).