• Title/Summary/Keyword: SRS(stereotactic radiosurgery)

Search Result 66, Processing Time 0.028 seconds

Stereotactic LINAC Radiosurgery of Meningiomas (선형가속기를 이용한 뇌수막종의 뇌정위적 방사선수술)

  • Ryu, Kyung-Sik;Son, Byung-Chul;Kim, Moon-Chan;Suh, Tae-Suk;Kay, Chul-Seung;Yoon, Sei-Chul;Kang, Joon-Ki
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.3
    • /
    • pp.317-323
    • /
    • 2000
  • Objective : To evaluate the role of stereotactic LINAC radiosurgery in treatment of meningiomas, the authors retrospectively analyzed the result of radiosurgery in our institute. Method: During last ten years, twenty patients underwent stereotactic LINAC radiosurgery(LINAC SRS) for meningiomas. The mean age of the patients was 51 years(22-78 years). The most common tumor location for radiosurgery was parasagittal, sphenoid wing and tentorial area. With regards to indications of radiosurgery for meningiomas, LINAC radiosurgery was done for primary treatment in six patients, for postoperative residual tumors in eleven patients, for postoperative regrowth in three patients. Mean tumor volume was $5.14cm^3$($0.28-15.1cm^3$), mean field diameter was 2.01cm(1.2-3cm). The mean marginal dose was 20.55Gy(13-30Gy). The follow-up evaluation was done annually with radiologic findings and clinical status. The mean follow-up period was 46.8(24-120) months. Result : In the radiologic response, the tumor volume was reduced in five(25%) of twenty patients, fourteen showed arrested growth(70%), but one patient showed increased growth(5%). In the clinical response, nine patients improved clinically(45%), ten patients was stable(50%) and one patient worsened during follow-up period. With regards to correlation with radiologic and clinical response, in nineteen patients who showed radiologic response to radiosurgery(decreased and arrested growth after radiosurgery), nine patients(47.4%) improved and ten patients (52.6%) showed no change, one patient(5%) had symptomatic radiation necrosis at four years after SRS, which needed craniotomy. Conclusion : The overall control rate of meningiomas with LINAC radiosurgery was 95% in radiologic follow up and 95% clinically. The radiation complication rate was 5%. These results indicate that LINAC radiosurgery can be considered as safe and effective method for meningiomas.

  • PDF

Radiosurgery for Cerebral Arteriovenous Malformation (AVM) : Current Treatment Strategy and Radiosurgical Technique for Large Cerebral AVM

  • Byun, Joonho;Kwon, Do Hoon;Lee, Do Heui;Park, Wonhyoung;Park, Jung Cheol;Ahn, Jae Sung
    • Journal of Korean Neurosurgical Society
    • /
    • v.63 no.4
    • /
    • pp.415-426
    • /
    • 2020
  • Arteriovenous malformations (AVMs) are congenital anomalies of the cerebrovascular system. AVM harbors 2.2% annual hemorrhage risk in unruptured cases and 4.5% annual hemorrhage risk of previously ruptured cases. Stereotactic radiosurgery (SRS) have been shown excellent treatment outcomes for patients with small- to moderated sized AVM which can be achieved in 80-90% complete obliteration rate with a 2-3 years latency period. The most important factors are associated with obliteration after SRS is the radiation dose to the AVM. In our institutional clinical practice, now 22 Gy (50% isodose line) dose of radiation has been used for treatment of cerebral AVM in single-session radiosurgery. However, dose-volume relationship can be unfavorable for large AVMs when treated in a single-session radiosurgery, resulting high complication rates for effective dose. Thus, various strategies should be considered to treat large AVM. The role of pre-SRS embolization is permanent volume reduction of the nidus and treat high-risk lesion such as AVM-related aneurysm and high-flow arteriovenous shunt. Various staging technique of radiosurgery including volume-staged radiosurgery, hypofractionated radiotherapy and dose-staged radiosurgery are possible option for large AVM. The incidence of post-radiosurgery complication is varied, the incidence rate of radiological post-radiosurgical complication has been reported 30-40% and symptomatic complication rate was reported from 8.1% to 11.8%. In the future, novel therapy which incorporate endovascular treatment using liquid embolic material and new radiosurgical technique such as gene or cytokine-targeted radio-sensitization should be needed.

Feasibility Study of Dose Evaluation of Stereotactic Radiosurgery using GafChromic $EBT^{(R)}$ Film (GafChromic $EBT^{(R)}$ 필름을 이용한 뇌정위방사선치료의 선량분석 가능성 평가)

  • Jang, Eun-Sung;Lee, Chul-Soo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.1
    • /
    • pp.27-33
    • /
    • 2007
  • Purpose: We have performed SRS (stereotactic radiosurgery) for avm (arterry vein malformation) and brain cancer. In order to verify dose and localization of SRS, dose distributions from TPS ($X-Knife^{(R)}$ 3.0, Radionics, USA) and GafChromic $EBT^{(R)}$ film in a head phantom were compared. Materials and Methods: In this study, head and neck region of conventional humanoid phantom was modified by substituting one of 2.5 cm slap with five 0.5 cm acrylic plates to stack the GafChromic $EBT^{(R)}$ film slice by slice with 5 mm intervals. Four films and five acrylic plates were cut along the contour of head phantom in axial plane. The head phantom was fixed with SRS head ring and adapted SRS localizer as same as real SRS procedure. CT images of the head phantom were acquired in 5 mm slice intervals as film interval. Five arc 6 MV photon beams using the SRS cone with 2 cm diameter were delivered 300 cGy to the target in the phantom. Ten small pieces of the film were exposed to 0, 50, 100, 200, 300, 400, 500, 600, 700, 800, 900 cGy, respectively to calibrate the GafChromic $EBT^{(R)}$ film. The films in the phantom were digitized after 24 hours and its linearity was calibrated. The pixel values of the film were converted to the dose and compared with the dose distribution from the TPS calculation. Results: Calibration curve for the GafChromic $EBT^{(R)}$ film was linear up to 900 cGy. The R2 value was better than 0.992. Discrepancy between calculated from $X-Knife^{(R)}$ 3.0 and measured dose distributions with the film was less than 5% through all slices. Conclusion: It was possible to evaluate every slice of humanoid phantom by stacking the GafChromic EBT film which is suitable for 2 dimensional dosimetry, It was found that film dosimetry using the GafChromic $EBT^{(R)}$ film is feasible for routine dosimetric QA of stereotactic radiosurgery.

  • PDF

Change in Plasma Vascular Endothelial Growth Factor after Gamma Knife Radiosurgery for Meningioma : A Preliminary Study

  • Park, Seong-Hyun;Hwang, Jeong-Hyun;Hwang, Sung-Kyoo
    • Journal of Korean Neurosurgical Society
    • /
    • v.57 no.2
    • /
    • pp.77-81
    • /
    • 2015
  • Objective : The purpose of this study was to investigate changes in the plasma level of vascular endothelial growth factor (VEGF) after Gamma Knife radiosurgery (GKRS) for the treatment of meningioma. Methods : Fourteen patients with meningiomas had peripheral venous blood collected at the time of GKRS and at 1 week, 1 month, 3 month and 6 month visits. Plasma VEGF levels were measured using commercially available enzyme-linked immunosorbent assay. For controls, peripheral blood samples were obtained from 20 healthy volunteers. Results : The mean plasma VEGF level (29.6 pg/mL) in patients with meningiomas before GKRS was significantly lower than that of the control group (62.4 pg/mL, p=0.019). At 1 week after GKRS, the mean plasma VEGF levels decreased to 23.4 pg/mL, and dropped to 13.9 pg/mL at 1 month, 14.8 pg/mL at 3 months, then increased to 27.7 pg/mL at 6 months. Two patients (14.3%) with peritumoral edema (PTE) showed a level of VEGF 6 months after GKRS higher than their preradiosurgical level. There was no significant association found in an analysis of correlation between PTE and tumor size, marginal dose, age, and sex. Conclusion : Our study is first in demonstrating changes of plasma VEGF after stereotactic radiosurgery (SRS) for meningioma. This study may provide a stimulus for more work related to whether measurement of plasma level has a correlation with tumor response after SRS for meningioma.

Methodologic Aspect of LINAC-based Stereotactic Radiosurgery (선형가속기 기반 뇌정위 방사선 수술기법)

  • Choi, Tae Jin
    • Progress in Medical Physics
    • /
    • v.23 no.3
    • /
    • pp.127-137
    • /
    • 2012
  • A conversing beam is firstly designed for radiosurgery by a neurosugern Lars Leksell in 1949 with orthogonal x-rays tube moving through horizontal moving arc to focusing the beam at target center. After 2 decades he composits 201 source of the Co-60 for gamma knife which beams focused at locus. Sveral linac-based stereotactic radiosurgery using the circular collimated beam which size range for 0.4~4.0 cm in a diameter by non-coplanar multiarc have been developed over the decades. The irregular lesions can be treated by superimposing with several spherical shots of radiation over the tumour volume. Linac based techniques include the use of between 4 and 11 non-co-planar arcs and a dynamic rotation technique and use photon beam energies in the range of 6~10 MV. Reviews of the characteristics of several treatment techniques can be found in the literature (Podgorsak 1989, Schell 1991). More in recent, static conformal beams defined by custom shaped collimators or a mini- or micro-multileaf collimator (mMLC) have been used in SRS. Finally, in the last few years, intensity-modulated mMLC SRS has also been introduced. Today, many commercial and in-house SRS programs have also introduced non-invasive immobilization systems include the cyberknife and tomotherapy and proton beam. This document will be compared the characteristics of dose distribution of radiosurgery as introduced gamma knife, BrainLab include photon knife in-house SRS program and cyberknife in currently wide used for a cranial SRS.

Hearing Outcome after Gamma Knife Stereotactic Radiosurgery in Vestibular Schwannoma Patients with Serviceable Hearing

  • Cho, Jae-Hoon;Paek, Sun-Ha;Chung, Hyun-Tai;Jeong, Sang-Soon;Jung, Hee-Won;Kim, Dong-Gyu
    • Journal of Korean Neurosurgical Society
    • /
    • v.40 no.5
    • /
    • pp.336-341
    • /
    • 2006
  • Objective : The authors conducted a retrospective study to evaluate the preservation rates of serviceable hearing and to determine its prognostic factors after gamma knife stereotactic radiosurgery[GK SRS] in the patient with vestibular schwannomas. Methods : Between December 1997 and March 2005, 54 patients with a sporadic vestibular schwannoma and serviceable hearing [Gardner Robertson grade I-II] were enrolled in this study. Electronic database of medical records and radiological examinations before and after GK SRS were investigated to the last follow up. The mean marginal dose was $12.3{\pm}0.7Gy$. The mean maximum dose delivered to the tumor center was 24.7Gy [$22{\sim}30Gy$]. The median tumor volume was 2cc [$0.1{\sim}9.1cc$]. The median follow-up period of magnetic resonance[MR] imaging was 31 months [$6{\sim}99\;months$], and the mean follow-up period of audiometry was 24 months [$4{\sim}70\;months$]. Results : The tumor control rate was 100% in the patients with the follow up period more than 2 years. The trigeminal and facial nerve preservation rates were 98% and 100%, respectively. Twenty-eight [52%] of the 54 patients preserved serviceable hearing and 16 [30%] patients retained their pre-GK G-R grade level after GK SRS. In the univariate and multivariate analysis, there was no significant prognostic factor in preservation of the serviceable hearing. Conclusion : The hearing preservation rate is still unsatisfactory compared with the results of other cranial nerve preservation and tumor control in the treatment of vestibular schwannoma by GK SRS. More sophisticated strategy during and after GK SRS is necessary to improve long-term hearing preservation.

Radiosurgery Compared with External Radiation Therapy as a Primary Treatment in Spine Metastasis from Hepatocellular Carcinoma : A Multicenter, Matched-Pair Study

  • Sohn, Seil;Chung, Chun Kee;Sohn, Moon Jun;Kim, Sung Hwan;Kim, Jinhee;Park, Eunjung
    • Journal of Korean Neurosurgical Society
    • /
    • v.59 no.1
    • /
    • pp.37-43
    • /
    • 2016
  • Objective : The aim of this multicenter, matched-pair study was to compare the outcomes of stereotactic radiosurgery (SRS) and conventional external radiation therapy (RT) when used as a primary treatment in spine metastasis from hepatocellular carcinoma (HCC). Methods : From 2005 to 2012, 28 patients underwent SRS as the primary treatment in spine metastasis from HCC. Based on sex, age, number of spine metastasis, Child-Pugh classification, interval from original tumor to spine metastasis, and year of treatment, 28 patients who underwent RT were paired. Outcomes of interest were pain relief, progression free survival, toxicities, and further treatment. Results : The perioperative visual analog scale (VAS) decrease was larger in SRS group than in RT group, but the difference was not significant (3.7 vs. 2.8, p=0.13). When pain medication was adjusted, the number of patients with complete (n=6 vs.3) or partial (n=12 vs.13) relief was larger in SRS group than in RT group; however, the difference was not significant (p=0.83). There was no significant difference in progression free survival (p=0.48). In SRS group, 32.1% of patients had 1 or more toxicities whereas the percentage in RT group was 63.0%, a significant difference (p=0.04). Six SRS patients and 7 RT patients received further intervention at the treated segment. Conclusion : Clinical and radiological outcome were not significantly different between the two treatments. Toxicities, however, were more prevalent in the RT group.

Evaluation of response to stereotactic radiosurgery in patients with radioresistant brain metastases

  • Sayan, Mutlay;Mustafayev, Teuta Zoto;Sahin, Bilgehan;Kefelioglu, Erva Seyma Sare;Wang, Shang-Jui;Kurup, Varsha;Balmuk, Aykut;Gungor, Gorkem;Ohri, Nisha;Weiner, Joseph;Ozyar, Enis;Atalar, Banu
    • Radiation Oncology Journal
    • /
    • v.37 no.4
    • /
    • pp.265-270
    • /
    • 2019
  • Purpose: Renal cell carcinoma (RCC) and melanoma have been considered 'radioresistant' due to the fact that they do not respond to conventionally fractionated radiation therapy. Stereotactic radiosurgery (SRS) provides high-dose radiation to a defined target volume and a limited number of studies have suggested the potential effectiveness of SRS in radioresistant histologies. We sought to determine the effectiveness of SRS for the treatment of patients with radioresistant brain metastases. Materials and Methods: We performed a retrospective review of our institutional database to identify patients with RCC or melanoma brain metastases treated with SRS. Treatment response were determined in accordance with the Response Evaluation Criteria in Solid Tumors. Results: We identified 53 radioresistant brain metastases (28% RCC and 72% melanoma) treated in 18 patients. The mean target volume and coverage was 6.2 ± 9.5 mL and 95.5% ± 2.9%, respectively. The mean prescription dose was 20 ± 4.9 Gy. Forty lesions (75%) demonstrated a complete/partial response and 13 lesions (24%) with progressive/stable disease. Smaller target volume (p < 0.001), larger SRS dose (p < 0.001), and coverage (p = 0.008) were found to be positive predictors of complete response to SRS. Conclusion: SRS is an effective management option with up to 75% response rate for radioresistant brain metastases. Tumor volume and radiation dose are predictors of response and can be used to guide the decision-making for patients with radioresistant brain metastases.

Effectiveness of the Respiratory Gating System for Stereotectic Radiosurgery of Lung Cancer (Lung Cancer의 Stereotactic Radiosurgery시 Respiratory Gating system의 유용성에 대한 연구)

  • Song Heung Kwon;Kim Min Su;Yang Oh Nam;Park Cheol Su;Kwon Kyung Tae;Kim Jeong Man
    • 대한방사선치료학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.13-17
    • /
    • 2005
  • Introduction : For stereotactic radiosurgery (SRS) of a tumor in the region whose movement due to respiration is significant, like Lung lower lobe, the gated therapy, which delivers radiation dose to the selected respiratory phases when tumor motion is small, was peformed using the Respiratory gating system and its clinical effectiveness was evaluated. Methode and Materials : For two SRS patients with a tumor in Lung lower lobe, a marker block (infrared reflector) was attached on the abdomen. While patient' respiratory cycle was monitored with Real-time Position Management (RPM, Varian, USA), 4D CT was performed (10 phases per a cycle). Phases in which tumor motion did not change rapidly were decided as treatment phases. The treatment volume was contoured on the CT images for selected treatment phases using maximum intensity projection (MIP) method. In order to verify setup reproducibility and positional variation, 4D CT was repeated. Result : Gross tumor volume (GTV) showed maximum movement in superior-inferior direction. For patient $\#$1, motion of GTV was reduced to 2.6 mm in treatment phases ($30\%\~60\%$), while that was 9.4 mm in full phases ($0\%\~90\%$) and for patient $\#$2, it was reduced to 2.3 mm in treatment phases ($30\%\~70\%$), while it was 11.7 mm in full phases ($0\%\~90\%$). When comparing two sets of CT images, setup errors in all the directions were within 3 mm. Conclusion : Since tumor motion was reduced less than 5 mm, the Respiratory gating system for SRS of Lung lower lobe is useful.

  • PDF

Development of Stereotactic Surgery system with CT, MR Imaging, and Angiography (컴퓨터 단층촬영, 자기공명영상, 뇌혈관촬영을 이용한 정위적 수술시스템의 개발)

  • Kim, S.H.;Suh, T.S.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.117-118
    • /
    • 1998
  • The aim of this work is to develop 3-D stereotactic localization system in order to determine the precise shape, size and location of the lesion in the brain in the field of Stereotactic Radiosurgery(SRS) and neurosurgery using CT/MRI/angiography and multi-purpose QA phantom. The algorithms to obtain a 3-D stereotactic coordinates of the target have been developed, and targets on each CT image were superimposed each other on MR/angiography images without distortion corretion. This system was implented in Visual C++ as a PC-based application program.

  • PDF