• Title/Summary/Keyword: SRM analysis

Search Result 388, Processing Time 0.027 seconds

Distribution Characteristics of Platinum Group Elements in Roadside Dust from Daejeon, Korea (대전 도로변 먼지내 Platinum Group Elements의 분포 특성)

  • Lim, Jong-Myoung;Jeong, Jin-Hee;Lee, Jin-Hong
    • Journal of Environmental Impact Assessment
    • /
    • v.27 no.5
    • /
    • pp.405-416
    • /
    • 2018
  • In this research, the distribution of Platinum Group Elements (PGEs) at roadside dust in Daejeon, Korea was examined using an ICP-MS (Inductively Coupled Plasma-Mass Spectrometry) technique. For the quality assurance of the determination, method validation based on its accuracy and precision was conducted using SRM (Standard Reference Material). It was found that the relative errors of Pt, Pd, and Rh against each SRM value were -0.7%, -10.0%, and -20.4%, respectively, while relative standard deviations for three elements were less than 10%. The concentrations of Pt, Pd and Rh in roadside dust averaged as $17.4{\pm}9.2{\mu}g/kg$, $283.6{\pm}20.5{\mu}g/kg$, and $7.3{\pm}2.8{\mu}g/kg$, respectively. The concentrations of Pt and Rh have significantly higher distribution patterns in the dust at roadside and underground parking lot than those in soil of the background or other urban area. The correlation analysis between concentrations of PGEs in roadside dust indicates that the distribution of Pt and Rh concentration were strongly affected by automobile sources.

Optimal Conditions for Pretreated Sample for Sr Isotope Analysis by MC-ICP-MS: A Comparison Between Eichrom (SR-R50-S)'s and Bio-Rad(AG®50W-X8)'s Resins (다검출기 유도결합 플라즈마 질량분석기에 의한 Sr 동위원소 분석을 위해 전처리된 시료의 최적 조건: Eichrom사 Sr 수지(SR-R50-S)와 Bio-Rad사 수지(AG®50W-X8) 비교)

  • Myoung Jung, Kim;Seung-Gu, Lee
    • Korean Journal of Mineralogy and Petrology
    • /
    • v.35 no.4
    • /
    • pp.507-520
    • /
    • 2022
  • The Sr isotope ratio, which is used as basic data for rock formation time, crustal and mantle evolution studies, is determined by mass spectrometer such as thermal ionization mass spectrometry (TIMS) or multi-detector inductively coupled plasma mass spectrometry (MC-ICP-MS). In this technical report, we compared how incomplete chemical separation of elements affects the determination of Sr isotope ratios. For the experiment, commercial resin, NBS987(NIST SRM987) Sr isotope standard, and rock standard samples from the Geological Survey of Japan (GSJ) such as JG1a, JB3 and JA1 were used. As a result of the comparative experiment, it was clearly observed that the measured values of 87Sr/86Sr change when Rb remains due to incomplete separation of the NBS987 Sr isotope standard sample as well as the rock standard samples of GSJ. This indicates that complete separation is an important factor since the calculated value deviates from the true value even though correction for isotope interference by isobar is performed when measuring the isotope ratio with MC-ICP-MS. This also suggests that, when reporting the measurement result of Sr isotope ratio using MC-ICP-MS, the measurement strength of 85Rb should be reported together with the measurement strength of all isotopes of Sr so that isotope interference by isobar can be judged.

Preconcentration and Determination of Fe(III) from Water and Food Samples by Newly Synthesized Chelating Reagent Impregnated Amberlite XAD-16 Resin

  • Tokahoglu, Serife;Ergun, Hasan;Cukurovah, Alaaddin
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.7
    • /
    • pp.1976-1980
    • /
    • 2010
  • A simple and reliable method has been developed to selectively separate and concentrate trace amounts of Fe(III) ions from water and food samples by using flame atomic absorption spectrometry. A new reagent, 5-hydroxy-4-ethyl-5,6-di-pyridin-2-yl-4,5-dihydro-2H-[1,2,4] triazine-3-thione, was synthesized and characterized by using FT-IR spectroscopy and elemental analysis. Effects of pH, concentration and volume of elution solution, sample flow rate, sample volume and interfering ions on the recovery of Fe(III) were investigated. The optimum pH was found to be 5. Eluent for quantitative elution was 10 mL of 2 M HCl. The preconcentration factor of the method, detection limit (3s/b, ${\mu}gL^{-1}$) and relative standard deviation values were found to be 25, 4.59 and 1%, respectively. In order to verify the accuracy of the method, two certified reference materials (TMDA 54.4 lake water and SRM 1568a rice flour) were analyzed. The results obtained were in good agreement with the certified values. The method was successfully applied to the determination of Fe(III) ions in water and food samples.

Determination of Corticosteroids in Moisturizers by LC-MS/MS

  • Park, Sumin;Choi, Gye Young;Lee, Seon-Ah;Kim, Hyun Jeong;Yum, Hye Yung;Paeng, Ki-Jung
    • Mass Spectrometry Letters
    • /
    • v.7 no.1
    • /
    • pp.26-29
    • /
    • 2016
  • Simultaneous determination of three corticosteroids (clobetasol propionate, betamethasone dipropionate, fluticasone propionate) in moisturizers was performed by using liquid chromatography (LC) coupled with tandem mass spectrometry (MS/MS). Sample preparation was conducted by the liquid-liquid extraction (LLE). Moisturizers include emulsifying agent and it forms micelles. In order to improve the extraction efficiency of corticosteroids trapped in micelle, newly developed-optimized extraction conditions which can remove the matrix effect from moisturizers was applied with various pH conditions in LLE extraction stage of sample preparation. Thus, the addition of 10 μL of 1 M HCl into moisturizers sample before extraction could improve the extraction efficiency. For the quantitative analysis, SRM table that contained specific transition of all of target corticosteroids was created. The developed method was validated for linearity, accuracy, precision, limit of detection (LOD), limit of quantization (LOQ) and recovery. Over the 0.99 r2 value was obtained in calibration standard range. Effective accuracy and precision were also obtained. LODs were below 31 ng/mL and LOQs were estimated below 94 ng/mL for all corticosteroids tested.

Optimum Geometric and Electrical Parameter for minimization Torque Ripple of Switched Reluctance Motor (스위치드 릴럭턴스 전동기의 토오크 리플 저감을 위한 기하학적인 파라미터와 전기적인 파라미터의 최적화)

  • Jung, S.I.;Choi, J.H.;Kim, Y.H.;Kim, S.;Lee, J.;Ju, M.S.;Choi, D.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.608-610
    • /
    • 2001
  • In this paper, 6/4 Switched Reluctance Motor(SRM) which has simple structure and little switching element is selected basic analysis model. In order to reduce torque ripple causing noise and vibration, we execute optimization of geometric parameters (stator and rotor pole arc) and electrical parameters (turn-on angle and turn-of angle) by means of combining Fletcher-Reeves's Conjugate Directions and Finite Element Method (FEM) considering driving circuits. When considering the switching condition according to inductance profile, torque characteristics is influenced by geometric and electrical parameters importantly. The pole arc and switching angle of the optimum can also obtain the low torque ripple without high currents.

  • PDF

Hologram Based QSAR Analysis of Caspase-3 Inhibitors

  • Sathya., B
    • Journal of Integrative Natural Science
    • /
    • v.11 no.2
    • /
    • pp.93-100
    • /
    • 2018
  • Caspases, a family of cysteinyl aspartate-specific proteases plays a central role in the regulation and the execution of apoptotic cell death. Caspase-3 has been proven to be an effective target for reducing the amount of cellular and tissue damage because the activation of caspases-3 stimulates a signalling pathway that ultimately leads to the death of the cell. In this study, Hologram based Quantitative Structure Activity Relationship (HQSAR) models was generated on a series of Caspase-3 inhibitors named 3, 4-dihydropyrimidoindolones derivatives. The best HQSAR model was obtained using atoms, bonds, and hydrogen atoms (A/B/H) as fragment distinction parameter using hologram length 61 and 3 components with fragment size of minimum 5 and maximum 8. Significant cross-validated correlation coefficient ($q^2=0.684$) and non cross-validated correlation coefficients ($r^2=0.754$) were obtained. The model was then used to evaluate the eight external test compounds and its $r^2_{pred}$ was found to be 0.559. Contribution map show that presence of pyrrolidine sulfonamide ring and its bulkier substituent's makes big contributions for improving the biological activities of the compounds.

Analysis and Design of 12/14 Bearingless Switched Reluctance Motor for Self-Starting and Torque Ripple Reduction (자기기동 및 토크리플 저감을 위한 12/14 베어링리스 SRM의 설계 및 특성해석)

  • Xu, Zhenyao;Lee, Dong-Hee;An, Young-Ju;Ahn, Jin-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.682-684
    • /
    • 2015
  • A 12/14 bearingless switched reluctance motor (BLSRM) with hybrid stator poles has been proposed due to the outstanding decoupling characteristics between the torque and suspending force. However, the motor is a two-phase motor. The output torque of the motor has torque dead zone and high torque ripple. Hence, the motor cannot self-start at some rotor positions. To solve the self-starting problems and reduce the torque ripple, a stepped rotor is proposed in this paper. Then, the motor with the stepped rotor is optimally designed. In the new designed motor, the majority parameters are kept the same with those of original motor; only the torque pole arc and rotor pole shape are optimally designed. The characteristics of the redesigned motor, such as inductance, torque and suspending force, are analyzed and compared with those in the original motor. Finally, the effectiveness of the proposed method is verified by the simulation results.

  • PDF

Continuous Preconcentration of Sn2+/Sn4+ by the On-line Sulfide Precipitation-Dissolution

  • Yeon, Pyung-Heum;Yoon, Young-Suk;Oh, Se-Woung;Nam, Sang-Ho;Par, Yong-Nam
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.8
    • /
    • pp.1156-1160
    • /
    • 2004
  • The technique of an on-line preconcentration by the direct sulfide precipitation has been developed. Sn was homogeneously precipitated by sulfide, which was generated in situ from the hydrolysis of thioaceteamide. Precipitate was collected on a filter in the line and dissolved out instantaneously by KOH to be sent to an ICP. The enrichment factor was 4 with the sampling speed of 15/hr for 1.0 mL of sample. It was increased to more than 40 times when the sampling volume was increased to 10 mL with the sampling speed of 5/hr. $Sn^{2+}/Sn^{4+}$ could be separately determined with the on-line precipitation technique. The method was applied to the analysis of NIST SRM 1566 Oyster sample and yielded good agreement with the certified value.

Progress in hybrid greenhouse solar dryer (HGSD): A review

  • Singh, Pushpendra;Gaur, Manoj K.;Kushwah, Anand;Tiwari, G.N.
    • Advances in Energy Research
    • /
    • v.6 no.2
    • /
    • pp.145-160
    • /
    • 2019
  • The world population reaches to about 7.7 billion in 2018 from 6.2 billion in 2000. This much growth in population results in increased energy demand and increased food supply. As the conventional energy sources are limited. These may deplete soon if consumed at this rate. So, the world is switching towards the utilization of non-conventional sources of energy. Energy from sun is the best method as it can not only solve the energy issue but also helps in meeting food demand by conserving it. Greenhouses are made for the purpose of food conservation. Various types of solar dryers are developed by researchers till now and still the effort is being putted to make them more efficient. Hybrid greenhouse is also effort toward utilization of solar energy in more efficient way. The paper presents the heat and mass transfer analysis of hybrid greenhouse solar dryer developed by different researchers till now. The review helps the researcher in understanding the heat and mass transfer taking place inside the hybrid greenhouse and how it can be further improved.

Toxic Trace and Earth Crustal Elements of Ambient PM2.5 Using CCT-ICP-MS in an Urban Area of Korea

  • Lee, Jin-Hong;Jeong, Jin-Hee;Lim, Joung-Myung
    • Environmental Engineering Research
    • /
    • v.18 no.1
    • /
    • pp.3-8
    • /
    • 2013
  • Collision cell technology-inductively coupled plasma-mass spectrometry (CCT-ICP-MS) was used to measure the concentrations of approximately 19 elements associated with airborne PM2.5 samples that were collected from a roadside sampling station in Daejeon, Korea. Standard reference material (SRM 2783, air particulate on filter media) of the National Institute of Standards and Technology was used for the quality assurance of CCT-ICP-MS. The elemental concentrations were compared statistically with the certified (or recommended) values. The patterns of distribution were clearly distinguished between elements with their concentrations ranging over four orders of magnitude. If compared in terms of enrichment factors, it was found that toxic trace elements (e.g., Sb, Se, Cd, As, Zn, Pb, and Cu) of anthropogenic origin are much more enriched in PM2.5 samples of the study site. To the contrary, the results of the correlation analysis showed that PM2.5 concentrations can exhibit more enhanced correlations with the elements (e.g., Fe, K, Si, and Ti) arising from earth's crust. The findings of strong correlations between PM2.5 and the elements of crustal origin may be directly comparable with the dominant role of those species by constituting a major fraction of even PM2.5 as well as PM10 at the roadside area.