• 제목/요약/키워드: SRM analysis

검색결과 388건 처리시간 0.028초

Dynamic Analysis of Rotor Eccentricity in Switched Reluctance Motor with Parallel Winding

  • Li, Jian;Choi, Da-Woon;Cho, Yun-Hyun
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 추계학술대회 논문집
    • /
    • pp.85-87
    • /
    • 2008
  • This paper presents dynamic characteristics in Switched Reluctance Motor (SRM) with rotor eccentricity and proposes the reduction method of rotor eccentricity effects by the different winding connections. These characteristics investigations are computed by 2D transient magnetic FEM analysis coupled with external circuits. The radial and unbalance magnetic force in the stator, which is the main exciting force of the vibration, is calculated using Maxwell stress method and compared with the performance characteristics according to the serial and parallel connections of windings. The influence of winding method counteracting unbalance forces on the rotor vibration behavior is estimated by the current waveforms of the paralleled paths under rotor eccentricity.

  • PDF

환경시료의 방사능 분석에서 Monte Carlo 방법을 이용한 자체흡수 효과 보정 (Corrections of Self-Absorption Effect Using the Monte Carlo Method in the Radioactivity Analysis of Environmental Samples)

  • 서범경;이대원;이길용;윤윤일;양태건
    • Journal of Radiation Protection and Research
    • /
    • 제26권2호
    • /
    • pp.51-58
    • /
    • 2001
  • 환경방사능과 같은 저준위 방사능 측정에서는 원통형과 Marinelli형 측정용기가 가장 일반적으로 사용된다. 효율교정용 표준선원과 측정시료의 높이 또는 매질의 밀도가 다르면 자체흡수 효과의 차이로 인한 보정이 필요하다. 본 연구에서는 Monte Carlo 방법을 이용하여 HPGe 검출기의 전에너지 피크 효율을 계산하여 측정치와 비교하였다. 원통형 용기에 대해서는 높이에 대한 효율변화 정도를 계산하였고, 원통형 및 Marinelli 측정용기에 대해서는 밀도변화에 따른 효율을 계산하였다. 밀도에 따른 효율의 감소 정도는 1000keV 이하의 에너지 영역에 대해 자체흡수 효과의 보정치 필요하다는 것을 알았다. 또한 계산의 타당성을 검증하기 위하여 NIST SRM 4353 표준물질을 이용하여 계산값과 인증값을 상호비교한 결과 오차범위 이내로 잘 맞는 다는 것을 확인하였다.

  • PDF

유도결합 플라스마-질량분석법과 고체-액체 추출법을 이용한 혈액 및 소변중 미량금속의 분석에 관한 연구 (A Study of Analytical Method for Trace Metal Ions in Whole Blood and Urine by Inductively Coupled Plasma-Mass Spectrometry using Solid-Liquid Extraction Technique)

  • 이원;허영회;박경수
    • 분석과학
    • /
    • 제11권4호
    • /
    • pp.281-291
    • /
    • 1998
  • 혈액과 소변중의 미량 Cu, Sn 및 Bi를 유도결합 플라스마 질량분석법으로 동시 분석하였다. 혈액시료 1 mL를 closed-vessel digestion system에 넣고 질산과 과산화수소수를 가한 후 microwave oven에서 8분 동안 전처리하였다. Amberlite IRC-718 수지를 정지상으로 사용한, 고체-액체추출법으로 Na, S, P 및 polyatomic species에 의한 매트릭스 방해를 제거하였다. 위 방법에 대한 검출한계를 구한 결과 Cu는 0.000375 ng/mL, Sn 은 0.000297 ng/mL, Bi는 0.000174 ng/mL 이었다. NIST SRM 955a 혈액시료에 표준용액을 첨가하여 구한 회수율은 Cu의 경우 99.1%, Sn은 102.5%, Bi는 98.4%이었다. 아울러 본 연구에서 조사한 최적기기 및 분석조건에서 실제 혈액과 소변시료의 분석을 시도하였다.

  • PDF

HVG-ICPMS을 이용한 식물체 중 게르마늄과 셀레늄의 동시분석 연구 (The simultaneous determination of germanium and selenium in plant by hydride vapour generator inductively coupled plasma mass spectrometry)

  • 함용규;김보경;권영욱;백효현;이석기
    • 분석과학
    • /
    • 제24권3호
    • /
    • pp.159-167
    • /
    • 2011
  • 식물 체중에 포함되어 있는 항산화제로서 주목받고 있는 게르마늄과 셀레늄의 극미량 분석에 있어서의 재현성 있는 분석방법을 제시하고자 수소화물생성장치와 유도결합플라스마질량분석기를 이용하여 분석하였다. 유도결합플라스마질량분석기에 일반적으로 사용되는 torch 대신 에너지 밀도를 높여 이온 간섭, 분자이온 생성 등의 간섭현상을 줄일 수 있는 mini torch를 사용하여 산 종류와 농도의 영향, 수소화물의 생성을 위한 환원조건, 시료 전처리 방법의 차이 등 다양한 조건하에서 상추 중의 게르마늄과 셀레늄을 분석하였다. 분석의 정확성을 평가하기 위하여 회수율 검증과 셀레늄의 표준시료인 SRM-1547, 1570a을 분석하여 기준 값과 비교함으로서 분석의 정확성을 평가하여 다음과 같은 결론을 얻었다.

고체 추진기관 구조체의 설계 자동화 프로그램 개발 (Development of Automatic Design Program for Solid Rocket Motors Structure)

  • 김원훈;구송회;문순일;황기영;이강수;석정호
    • 한국추진공학회지
    • /
    • 제10권3호
    • /
    • pp.18-25
    • /
    • 2006
  • 체계 요구조건에 빠르고 정확한 자료제공을 위해 고체추진기관 구조체에 대한 설계자동화 프로그램인 'ProDes'를 개발하고 검증하여 그 성능을 입증하였다 주어진 체계설계 요구도 및 구속조건으로부터 총 개발기간과 인력을 획기적으로 감소시키며, 또 설계, 해석, 시뮬레이션 및 도면화 등 일련의 업무를 통합적으로 수행하기 위해 프로그램 개발이 수행되었다. 프로그램은 모듈화되어 있으며, 각 단계별 계산은 설계 변수별 적용연구가 수행되어 최종 설계 목표치에 도달되도록 구성 되어있다. 다양한 종류의 마스터 모델로 된 구성품과 체결형태는 구축된 라이브러리 DB 모듈로부터 얻어진다. 개발 프로그램을 이용한 추진기관 구조체 설계와 기존 상세된 설계를 비교 분석한 결과 서로 잘 일치함을 확인하였다.

Design and comparative study of various Two-Dimensional Grain Configurations based on Optimization Method

  • Nisar, Khurram;Liang, Guozhu
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년 영문 학술대회
    • /
    • pp.226-234
    • /
    • 2008
  • Grain design has always been a vital and integral part of Solid Rocket Motor(SRM) design. Basing on the design objectives set by the system designer, the SRM designer has many options available for selecting the Grain configuration. Many of the available configurations may fulfill the required parameters of volumetric loading fraction, web fraction & Length to diameter ratios and produce internal ballistic results that may be in accordance to the design objectives. However, for any given set of design objectives, it is deemed necessary that best possible configuration be selected, designed and optimized. Hence optimal results of all applicable configurations are vital to be attained in order to compare and finalize the design that will produce most efficient performance. Generally the engineers pay attention and have skills on a specific grain configuration. The designing methodologies and computer codes available usually focus on single grain configuration may it be Star, Wagon Wheel or slotted tube. Hardly one can find a software or a design methodology where all such configurations can be worked on jointly and not only adequate designs be found but optimal solutions reached by applying an optimization method to find final design best suited for any design objective. In the present work design requirements have been set, grain configurations have been selected and their designing has been conducted. The internal ballistic parameters have been calculated and after finding the preliminary design solutions, the optimal solutions have been found. In doing so, software has been developed comprising of computer programs for designing the 2D grains including Star, Wagon Wheel and Slotted Tube configurations. The optimization toolbox of Matlab Fmincon has been used for getting optimal solutions. The affects of all the independent geometric design variables on the optimized solutions have been analyzed. Based on results attained from Optimization Method, an in depth comparison of Grain Configurations and analysis of performance prediction outputs have been conducted to come to conclusion as to which grain configuration is ideal for the current design requirement under study.

  • PDF

Template-free preparation of TiO2 microspheres for the photocatalytic degradation of organic dyes

  • Al Ruqaishy, Mouza;Al Marzouqi, Faisal;Qi, Kezhen;Liu, Shu-yuan;Karthikeyan, Sreejith;Kim, Younghun;Al-Kindy, Salma Mohamed Zahran;Kuvarega, Alex Tawanda;Selvaraj, Rengaraj
    • Korean Journal of Chemical Engineering
    • /
    • 제35권11호
    • /
    • pp.2283-2289
    • /
    • 2018
  • $TiO_2$ microspheres were successfully synthesised by simple solution phase method by using various amount of titanium butoxide as precursor. The prepared $TiO_2$ were characterized by X-ray diffraction (XRD), UV-vis diffuse reflectance absorption spectra (UV-DRS), X-ray photoelectron spectroscopy (XPS) and scanning electron microscopy (SEM). XRD analysis revealed that the as-synthesized $TiO_2$ microsphere poses an anatase phase. The photocatalytic degradation experiments were carried out with three different dyes, such as methylene blue, brilliant black, reactive red-120 for four hours under UV light irradiation. The results show that $TiO_2$ morphology had great influence on photocatalytic degradation of organic dyes. The experimental results of dye mineralization indicated the concentration was reduced by a high portion of up to 99% within 4 hours. On the basis of various characterization of the photocatalysts, the reactions involved to explain the photocatalytic activity enhancement due to the concentration of titanium butoxide and morphology include a better separation of photogenerated charge carriers and improved oxygen reduction inducing a higher extent of degradation of aromatics.

동위원소희석 액체크로마토그래피/질량분석법에 의한 혈청 내 콜레스테롤의 정량 (Quantification of cholesterol in human serum by isotope dilution liquid chromatography/mass spectrometry)

  • 신혜선;이화심;이계호
    • 분석과학
    • /
    • 제21권6호
    • /
    • pp.502-509
    • /
    • 2008
  • 혈청 내 콜레스테롤을 정량분석하기 위한 일차분석법으로 동위원소희석 액체크로마토그래피/질량분석법(isotope dilution liquid chromatography/mass spectrometry)을 사용하였다. 콜레스테롤은 Thermo ODS hypersil $C^{18}$ 칼럼을 사용하여 분리하였고, 이동상은 100% 메탄올, 유속은 0.3 mL/min으로 하였다. 콜레스테롤과 콜레스테롤-$3,4-13C_2$$[M-H_2O+H]^+$이온에 해당하는 m/z 369.4와 371.3에서 모니터링하여 정량에 합당한 크로마토그램을 얻을 수 있었다. 방법의 유효성을 증명하기 위해서 NIST SRM 909b를 분석한 결과 인증값과 불확도 범위 내에서 일치하는 것을 확인하였다. 이 방법을 바탕으로 혈청 인증표준 물질 4 종류를 제조하여 인증을 실시하였다. 인증 결과, 반복성의 상대표준오차는 0.1~0.8%, 재현성의 경우 0.24%이하, 확장 불확도는 95% 신뢰도구간에서 약 1.43%로 나타났다.

Determination of Methylmercury in Biological Samples Using Dithizone Extraction Method Followed by Purge & Trap GC-MS

  • Lee, Jung-Sub;Ryu, Yoon-Jung;Park, Jae-Sung;Jeon, Sung-Hwan;Kim, Sam-Cwan;Kim, Young-Hee
    • Bulletin of the Korean Chemical Society
    • /
    • 제28권12호
    • /
    • pp.2293-2298
    • /
    • 2007
  • In this study, a dithizone extraction technique involving purge & trap GC-MS was developed for the determination of methylmercury in biological samples, especially blood and fish. After alkaline digestion, methylmercury in biological samples was extracted into dithizone and back-extracted into aqueous sulfide solution. The extracted methylmercury was converted to the volatile ethyl derivative, purged and trapped onto a solid-phase collection medium, and then introduced into the GC-MS system. The determined MDLs of the established method were 0.9 ng·g?1 for biological samples and its accuracy and precision were found to be 93% and 3.8%, respectively. The method was validated by analysis of CRMs such as SRM 966, BCR 463 and IAEA 407 and all analytical results were within certified ranges with average RSDs of less than 6%. The analytical results of field-sampled fish also showed that the method can be successfully used as an alternative for commonly used distillation method followed by GC-CVAFS detection.

HG-AAS에 의한 무기비소 분석 시 예비환원제의 최적화 조건과 분석에 미치는 영향 (Effects and optimum conditions of pre-reductant in the analysis of inorganic arsenic by hydride generation-atomic absorption spectrometry)

  • 송명진;박경수;김영만;이원
    • 분석과학
    • /
    • 제18권5호
    • /
    • pp.396-402
    • /
    • 2005
  • 수소화물 발생법-원자흡수 분광계를 이용한 무기비소의 분석 시 예비환원제로써 L-Cysteine, KI, $FeSO_4$의 최적 조건을 찾고자 하였으며, 이들이 분석에 미치는 영향을 서로 비교 연구하였다. 이와 더불어 $H_2SO_4$-trap에 의하여 시료 중 공존 가능성이 있는 유기비소인 MMA(monomethylarsonate)와 DMA(dimethylarsinate)를 제거하여 무기비소만을 분리 분석하였다. 1.8 M 염산과 0.08 M 질산의 혼합산에서 비소 표준용액 20 ppb는 산을 넣지 않았을 때보다도, 높은 흡광도를 나타내었다. L-Cysteine의 경우 0.5 g 정도를 취하고 약 0.07 M의 질산이나 염산의 약 산성 조건에서 30 분 이상을 반응시켰을 경우에 완전히 As(V)는 As(III)로 환원되었다. KI의 경우, 3 g 정도를 취하고 약 0.8 M의 질산 조건에서 1시간 이상 반응시켰을 경우에 완전히 As(V)는 As(III)로 환원되었다. $FeSO_4$의 경우에는, 다른 예비환원제와 비교하여 NaBH4와 $Fe^{2+}$의 반응으로 인한 침전물의 생성으로 튜브내부가 막히게 되어, As(V)가 As(III)로 환원되는 효율의 재현성이 없었다. 분석결과의 정확도를 확인하기 위하여, NIST SRM 1643C Trace Elements in Water ($82.1{\pm}1.2ng/mL$)를 사용하였으며 그 결과는 KI를 예비환원제로 사용하였을 경우에는 97.5%의 회수율이고 L-Cysteine를 예비환원제로 사용하였을 경우에는 101.9%의 회수율로서 두 경우 모두 만족할 만한 수준이였다.