• 제목/요약/키워드: SPR effect

검색결과 30건 처리시간 0.031초

Identification of the sprU Gene Encoding an Additional sprT Homologous Trypsin-Type Protease in Streptomyces griseus

  • YANG HYE-YOUNG;CHOI SI-SUN;CHI WON-JAE;KIM JONG-HEE;KANG DAE-KYUNG;CHUN JAESUN;KANG SANG-SOON;HONG SOON-KWANG
    • Journal of Microbiology and Biotechnology
    • /
    • 제15권5호
    • /
    • pp.1125-1129
    • /
    • 2005
  • Cloning of a 6.6-kb BamHI digested chromosomal DNA from S. griseus IFO13350 revealed the presence of an additional gene encoding a novel trypsin-like enzyme, named SprU. The SprU protein shows a high homology ($79\%$ identity, $88\%$ similarity) with the SGT protease, which has been reported as a bacterial trypsin in the same strain. The amino acid sequence deduced from the nucleotide sequence of the sprU gene suggests that SprU is produced as a precursor consisting of an amino-terminal presequence (29 amino acid residues), prosequence (4 residues), and mature trypsin consisting of 222 amino acids with a molecular weight of 22.94 kDa and a calculated pI of 4.13. The serine, histidine, and aspartic acid residues composing the catalytic triad of typical serine proteases are also well conserved. When the trypsin activity of the SprU was spectrophotometrically measured by the enzymatic hydrolysis of the artificial chromogenic substrate, N-${alpha}$-benzoyl-DL-arginine-p-nitroanilide, the S. lividans transformant with pWHM3-U gave 3 times higher activity than that of control. When the same recombinant plasmid was introduced into S. griseus, however, the gene dosage effect was not so significant, as in the cases of other genes encoding serine proteases, such as sprA, sprB, and sprD. Although two trypsins, SprU and SGT, have a high degree of homology, the pI values, the gene dosage effect in S. griseus, and the gene arrangement adjacent to the two genes are very different, suggesting that the biochemical and biological function of the SprU might be quite different from that of the SGT.

나노형상을 가진 표면플라즈몬공명 센서칩의 감도 개선 효과 (Effect of SPR Chip with Nano-structured Surface on Sensitivity in SPR Sensor)

  • 조용진;김철진;김남수;김종태;김태은;김효섭;김재호
    • 산업식품공학
    • /
    • 제14권1호
    • /
    • pp.49-53
    • /
    • 2010
  • 표면 플라즈몬 공명을 이용한 센서는 굴절계 기기의 일종으로서 높은 감도를 가질 뿐만 아니라 비표지 방식이라는 장점을 가지고 있다. 본 연구에서는 재래식 SPR 칩을 이용하여 시판 술 4종의 알코올 함량을 측정하였다. 또한, 재래식 SPR 칩의 감도를 개선하기 위하여 금 박막 위에 금으로 나노형상을 구축하여 나노형상 SPR 칩을 제조하여 모형 술에 대한 감도 개선 효과를 분석하였다. 재래식 SPR 칩을 이용하여 시판 술의 알코올 함량을 측정하기 위한 검량선을 개발하였을 때 시료를 전처리 하지 않고 그대로 측정하였을 때 가장 좋은 검량선을 얻을 수 있었다. 소주, 청주, 이과두주, 탁주 등 시판 술 4종에 대한 1차 회귀식의 검량식에서 결정계수는 각각 0.992, 0.933, 0.918, 그리고 0.984로 나타났다. 한편, 재래식 SPR 칩의 감도를 개선하기 위해 나노형상 SPR 칩을 제조하기 위하여 Langmuir-Blodgett(LB) 방법을 활용하였다. 본 연구에서는 수십 nm 두께의 금 박막을 바닥층으로 하여 그 위에 나노 크기의 실리카 입자를 단분자 층으로 덮어 형틀을 제조하고 다시 그 위에 금을 증착한 후 실리카 입자를 제거하는 방법으로 나노형상을 갖는 SPR 칩을 제조하였다. 나노형상 SPR 칩의 성능을 평가하였을 때 20% 알코올 함량을 가지는 모형 술에 대해서 바닥층의 두께가 50 nm, 나노형상에서 골의 깊이가 20 nm, 나노형상의 배열주기가 300 nm일 때 SPR의 감도가 가장 좋아서 95%의 감도 향상을 얻을 수 있었다. SPR의 감도는 칩과 관련된 인자, 시료의 종류 및 상태에 따라 다르게 나타날 수 있으므로 측정 목적에 알맞은 칩의 설계와 선택이 요구된다.

Characteristics of Protein G-modified BioFET

  • Sohn, Young-Soo
    • 센서학회지
    • /
    • 제20권4호
    • /
    • pp.226-229
    • /
    • 2011
  • Label-free detection of biomolecular interactions was performed using BioFET(Biologically sensitive Field-Effect Transistor) and SPR(Surface Plasmon Resonance). Qualitative information on the immobilization of an anti-IgG and antibody-antigen interaction was gained using the SPR analysis system. The BioFET was used to explore the pI value of the protein and to monitor biomolecular interactions which caused an effective charge change at the gate surface resulting in a drain current change. The results show that the BioFET can be a useful monitoring tool for biomolecular interactions and is complimentary to the SPR system.

유한요소해석을 통한 Steel-Al합금 SPR 접합공정 주요인자 분석 (Parametric Study of Steel-Al Alloy SPR Joint Process via Finite Element Analysis)

  • 김성호;박남수;송정한;노우람;박근영;배기현
    • 소성∙가공
    • /
    • 제29권6호
    • /
    • pp.301-306
    • /
    • 2020
  • The parametric study of Steel-Al alloy SPR joint process is based on the FE simulation described by Kim et al. [10], which was validated by comparing experimental and simulation results for two kinds of steel-Al alloy combinations according to the lower sheet thickness. To analyze the SPR joint process, the friction coefficient, the lower sheet thickness, and the rivet length were selected as the main parameters. Based on FE simulations, the effect of main parameters was investigated by measuring the interlock and the bottom thickness at the cross-sectional shape of the SPR joint. The results of simulation facilitate the design of SPR joint process in various metal combinations.

sprD유전자의 과발현이 Streptomyces griseus HH1의 분화에 미치는 영향 (Effect of the Overexpression of the sprD Gene Encoding Streptomyces griseus Pretense D for the Differentiation of Streptomyces griseus HH1)

  • 이재학
    • 한국식품영양학회지
    • /
    • 제15권4호
    • /
    • pp.364-369
    • /
    • 2002
  • 방선균은 토양 속에 다양하게 존재하는 미생물의 일종으로 그람 양성 진정세균으로 이차대사산물을 생산하는 시기와 포자 착생이 시작되는 세포분화의 시기가 밀접한 관련이 있다. S. griseus는 streptomycin을 비롯한 다양한 종류의 endopeptidase 및 exopeptidase들을 생산한다. 방선균에서의 protease 생산은 많은 경우에 이차대사산물이 형성되거나 형태분화가 유도되는 시기에 동시에 시작된다는 점에서 Pretense가 이차대사물질 생산 및 세포분화에 일정한 기능을 수행할 것이 라는 점을 시사하고 있다. 본 연구에서는 S. griseus IFO 13350에서 클로닝한 SGPD protease가 각 strain에서 형태학적으로나 생리적으로 어떠한 gene dosage 효과를 미치는지 조사하는 것이었다. sprD 유전자가 S.lividans를 숙주로 사용한 시스템에서 대량발현이 성공적으로 되는 것을 확인한 후, 본 유전자를 클로닝한 S. griseus IFO13350 균주와 이의 A-factor 결손주인 S. griseus HH1에 형질전환하였다. S. griseus HH1과 S. griseus IFO13350에서는 protease activity가 벡터만 도입된 대조군과 sprD 유전자가 들어간 형질전환체에서 큰 차이를 보이지 않았다. 또한 S. griseus IFO 13350 및 HH1 모두에서 생리학적·형태학적 분화의 차이를 발견하지 못하였다. Chymotrypsin계열의 pretense를 암호화하는 유전자만이 S. griseus에서 발현이 repression된다는 사실을 본 연구 결과를 통하여 알게 되었다. 이를 바탕으로 sprD유전자와 동일계열의 chymotrypsin 계열의 유전자들이 공통적으로 S. griseus에서 repression 되는 일반적인 기전이 있을 것으로 판단, chymotrypsin계열 유전자들의 promoter부분의 염기 상동성을 조사하였다 번역개시부위 바로 상부 유전자부터 상동성을 조사한 결과 적어도 상당부분의 염기배열이 잘 보존된 지역이 존재함을 알게 되었다. 향후 이들 발현기구의 조절기구를 연구함으로서 protease의 기능을 밝히는데 좋은 단서를 제공할 것으로 판단된다.

Effect of Total Collimation Width on Relative Electron Density, Effective Atomic Number, and Stopping Power Ratio Acquired by Dual-Layer Dual-Energy Computed Tomography

  • Jung, Seongmoon;Kim, Bitbyeol;Yoon, Euntaek;Kim, Jung-in;Park, Jong Min;Choi, Chang Heon
    • 한국의학물리학회지:의학물리
    • /
    • 제32권4호
    • /
    • pp.165-171
    • /
    • 2021
  • Purpose: This study aimed to evaluate the effect of collimator width on effective atomic number (EAN), relative electron density (RED), and stopping power ratio (SPR) measured by dual-layer dual-energy computed tomography (DL-DECT). Methods: CIRS electron density calibration phantoms with two different arrangements of material plugs were scanned by DL-DECT with two different collimator widths. The first phantom included two dense bone plugs, while the second excluded dense bone plugs. The collimator widths selected were 64 mm×0.625 mm for wider collimators and 16 mm×0.625 mm for narrow collimators. The scanning parameters were 120 kVp, 0.33 second gantry rotation, 3 mm slice thickness, B reconstruction filter, and spectral level 4. An image analysis portal system provided by a computed tomography (CT) manufacturer was used to derive the EAN and RED of the phantoms from the combination of low energy and high energy CT images. The EAN and RED were compared between the images scanned using the two different collimation widths. Results: The CT images with the wider collimation width generated more severe artifacts, particularly with high-density material (i.e., dense bone). RED and EAN for tissues (excluding lung and bones) with the wider collimation width showed significant relative differences compared to the theoretical value (4.5% for RED and 20.6% for EAN), while those with the narrow collimation width were closer to the theoretical value of each material (2.2% for EAN and 2.3% for RED). Scanning with narrow collimation width increased the accuracy of SPR estimation even with high-density bone plugs in the phantom. Conclusions: The effect of CT collimation width on EAN, RED, and SPR measured by DL-DECT was evaluated. In order to improve the accuracy of the measured EAN, RED, and SPR by DL-DECT, CT scanning should be performed using narrow collimation widths.

판매 프로세스 혁신의 성공모형에 대한 실증연구 (An Empirical Study on Selling Process Reengineering Success Model)

  • 김경민;방소연
    • 경영정보학연구
    • /
    • 제10권1호
    • /
    • pp.1-20
    • /
    • 2008
  • 본 연구는 영업조직에서 CRM 시스템에 대한 투자가 판매 프로세스 혁신이라는 성과를 이루기 위해서는 영업사원의 CRM 시스템 사용이 중요하다는 데 착안하여, CRM 시스템 사용에 영향을 미치는 조직 및 시스템 차원의 변수를 조사하였다. 또한 CRM 시스템 사용을 매개 변수로 보고 이들 변수와 판매프로세스 혁신과의 관계를 실증함으로써, 향후 기업들이 CRM 시스템 구축을 통해 판매 프로세스혁신을 이루고자 할 때 그 목표를 더욱 효과적으로 달성할 수 있게 한다는 데 본 연구의 의의가 있다.

Passivation of organic light emitting diodes with $Al_2O_3/Ag/Al_2O_3$ multilayer thin films grown by twin target sputtering system

  • Jeong, Jin-A;Kim, Han-Ki
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2008년도 International Meeting on Information Display
    • /
    • pp.420-423
    • /
    • 2008
  • The characteristics of $Al_2O_3/Ag/Al_2O_3$ multilayer passivaton prepared by twin target sputtering (TTS) system for organic light emitting diodes. The $Al_2O_3/Ag/Al_2O_3$ multilayer thin film passivation on a PET substrate had a high transmittance of 86.44 % and low water vapor transmission rate (WVTR) of $0.011\;g/m^2$-day due to the surface plasmon resonance (SPR) effect of Ag interlayer and effective multilayer structure for preventing the intrusion of water vapor. Using synchrotron x-ray scattering and field emission scanning electron microscope (FESEM) examinations, we investigated the growth behavior of Ag layer on the $Al_2O_3$ layer to explain the SPR effect of the Ag layer. This indicates that an $Al_2O_3/Ag/Al_2O_3$ multilayer passivation is a promising thin film passivation scheme for organic based flexible optoelectronics.

  • PDF

표면 플라즈몬 공명 센서를 이용한 주류의 알코올 함량 측정 (Measurement of Alcohol Contents in Alcoholic Beverages Using a Surface Plasmon Resonance Sensor)

  • 조용진;안병학;김철진;김종태
    • Journal of Biosystems Engineering
    • /
    • 제29권4호
    • /
    • pp.323-328
    • /
    • 2004
  • A surface plasmon resonance (SPR) sensing system, which belonged to a family of thin film refractometry-based sensors, was fabricated to measure the alcohol contents in alcoholic beverages. In this study, a SPR owe was obtained by a photodiode array with 128 pixels and transformed into a refractive index which was calculated by means of the first moment of values below a baseline of 0.85. When the sensing system was applied to Soju, Cheonju, Igwaduju and Tacju highly linear relationships between the refractive index by SPR and the contents of alcohol were obtained. That is, the coefficients of determination in their linear models were 0.992, 0.933, 0.918 and 0.954, respectively. Meanwhile, the effect of sample preparations on the accuracy of measurement was analyzed. As for Soju and Tacju, the best calibration equations were obtained when no sample preparation was applied. The best calibration models for measurement of Cheonju and Igwaduju were obtained through the samples filtered by $C_{18}$ disks.

보의 진동제어를 위한 압전 액추에이터의 길이변화 효과 연구 (Effect of Piezoactuator Length Variation for Vibration Control of Beams)

  • 이영섭
    • 한국소음진동공학회논문집
    • /
    • 제18권11호
    • /
    • pp.1185-1191
    • /
    • 2008
  • This paper presents an approach to define an optimal piezoactuator length to actively control structural vibration. The optimal ratio of the piezoactuator length against the beam length when a pair of piezoceramic actuator and accelerometer is used to suppress unwanted vibration with direct velocity feedback(DVFB) control strategy is not clearly defined so far. It is well known that DVFB control can be very useful when a pair of sensor and actuator is collocated on structures with a high gain and excellent stability. It is considered that three different collocated Pairs of piezoelectric actuators (20, 50 and 100 mm long) and accelerometers installed on three identical clamped-clamped beams($30{\times}20{\times}1mm$). The response of each sensor-actuator pair requires strictly positive real(SPR) property to apply a high feedback gain. However the length of the piezoactuator affects the SPR property of the sensor-actuator response. Intensive simulation and experiment show the effect of the actuator length variation is strongly related with the frequency range of the SPR property. Thus an optimal length ratio was suggested to obtain relevant performance with a good stability under the DVFB strategy.