• Title/Summary/Keyword: SPINS

Search Result 129, Processing Time 0.034 seconds

Controlling Spin State of Magnetic Molecules by Oxygen Binding Studied Using Scanning Tunneling Microscopy

  • Lee, Soon-hyeong;Chang, Yun Hee;Kim, Howon;Kim, Kyung Min;Kim, Yong-Hyun;Kahng, Se-Jong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.145.1-145.1
    • /
    • 2016
  • Binding and unbinding between molecular oxygen and metallo-porphyrin is a key process for oxygen delivery in respiration. It can be also used to control spin state of magnetic metallo-porphyrin molecules. Controlling and sensing spin states of magnetic molecules in such reactions at the single molecule level is essential for spintronic molecular device applications. Here, we demonstrate that spin states of metallo-porphyrin on surfaces can be controlled over by binding and unbinding of oxygen molecule, and be sensed using scanning tunneling microscopy and spectroscopy. Kondo localized state of metallo-porphyrin showed significant modification by the binding of oxygen molecule, implying that the spin state was changed. Our density functional theory calculation results explain the observations with the hybridization of unpaired spins in d and ${\pi}^*$ orbitals of metallo-porphyrin and oxygen, respectively. Our study opens up ways to control molecular spin state and Kondo effect by means of molecular binding and unbinding reactions on surfaces.

  • PDF

Switching and sensing molecular spins by chemical reactions on metal surfaces

  • Kahng, Se-Jong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.63.2-63.2
    • /
    • 2015
  • Controlling and sensing spin states of magnetic molecules such as metallo-porphyrins at the single molecule level is essential for spintronic molecular device applications. Axial coordinations of diatomic molecules to metallo-porphyrins also play key roles in dynamic processes of biological functions such as blood pressure control and immune response. However, probing such reactions at the single molecule level to understand their physical mechanisms has been rarely performed. Here we present on our single molecule association and dissociation experiments between diatomic and metallo-porphyrin molecules on Au(111) describing its adsorption structures, spin states, and dissociation mechanisms. We observed bright ring shapes in NO adsorbed metallo-porphyrin compelxes and explained them by considering tilted binding and precession motion of NO. Before NO exposure, Co-porphryin showed a clear zero-bias peak in scanning tunneling spectroscopy, a signature of Kondo effect in STS, whereas after NO exposures it formed a molecular complex, NO-Co-porphyrin, that did not show any zero-bias feature implying that the Kondo effect was switched off by binding of NO. Under tunneling junctions of scanning tunneling microscope, both positive and negative energy pulses. From the observed power law relations between dissociation rate and tunneling current, we argue that the dissociations were inelastically induced with molecular orbital resonances. Our study shows that single molecule association and dissociation can be used to probe spin states and reaction mechanisms in a variety of axial coordination between small molecules and metallo-porphyrins.

  • PDF

Development of a HDD Spindle Motor Using Passive Magnet Bearing and Fluid Dynamic Journal Bearing (수동형 자기 베어링과 유체 동압 저널베어링을 이용한 HDD용 스핀들 모터 개발)

  • Lee, Chung-Ill;Kim, Hak-Woon;Jang, Gun-Hee
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.473-477
    • /
    • 2005
  • This paper presents a highly efficient HDD (Hard Disk Drive) spindle motor with a passive magnetic thrust bearing and a fluid dynamic journal bearing and its effectiveness is verified through experiment. It eliminates the mechanical friction loss of a thrust bearing which is around 18% of total power consumption of a 3.5' HDD spindle motor, by replacing a conventional fluid dynamic thrust bearing with a passive magnetic thrust bearing. The passive magnetic thrust bearing using permanent magnets is inherently unstable in radial direction. However, the radial fluid dynamic force of the fluid dynamic journal bearing counterbalances the radial magnetic force of magnetic thrust bearing to achieve the stability as the motor spins up. It has less or equivalent runout and less flying height than the conventional spindle motor.

  • PDF

Total Cross Sections for Kilovolt Neutrons of Even-Odd Nuclei in the Region of the 3s Strength-Function Resonances

  • Mann-Cho;Bak, Hae-Ill;F.H. Frohner;K.N. Muller
    • Nuclear Engineering and Technology
    • /
    • v.2 no.4
    • /
    • pp.241-248
    • /
    • 1970
  • Neutron total cross sections of seperated isotopes were measured with the time-of-flight spectrometer at the 3 MeV Karlsruhe Van do Graaff Accelerator. The neutron energy ranged from 10 to 250 keV. The energy resolution was between 0.2 and 0.5 nsce/m. The measured cross sections were-shape-analyzed in terms of an R-matrix multilevel formula. Thus neutron widths and spins for up to 50 resonances per isotope could be determined. Average neutron widths, level densities and strength functions were derived. The spin dependence of strength functions and the distribution of widths and spacings were investigated.

  • PDF

A Design for a Home-Built Solid State NMR Spectrometer

  • Yang Doo-Kyung;Zax David B.
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.10 no.1
    • /
    • pp.74-88
    • /
    • 2006
  • Since the first commercial NMR spectrometer came out in 1953 from Varian, much of the hardware development has been improved and matured through commercial equipments. Many of magnetic resonance laboratories however still build and use home-built spectrometers, which are satisfactory even with the consideration of educational purpose only. The home-built NMR spectrometer could be further advantageous and could be often an only option for investigating new ideas with demanding experimental conditions or new hardware support. A solid state NMR spectrometer was designed with extra interest in stochastic experiment and built for an 8.93 T superconducting magnet from Oxford instrument. Super-heterodyned system was implemented for the transmitter and receiver parts. Intermediate frequency (IF) for the heterodyne system was chosen to 70 MHz for the first and the second channels, with additional 120 MHz for the third channel for maximum NMR frequency capability. We will show overall schematics, and discuss the designs with detailed diagrams, then demonstrate the applicability of home-built spectrometer with stochastic-excitation in solid state NMR and in applications to quadrupolar nuclear Spins.

  • PDF

Magnetic Properties of Modified DNAs

  • Do, Eui-Doo;Lee, Chang-Hoon;Kwon, Young-Wan;Choi, Dong-Hoon;Jin, Jung-Il;Oh, Dong-Keun;Nishide, Hiroyuki;Kurata, Takashi
    • Proceedings of the Polymer Society of Korea Conference
    • /
    • 2006.10a
    • /
    • pp.3-4
    • /
    • 2006
  • Natural DNAs in dry state, i.e., A-DNAs, when intercalated with low levels of stable organic free radicals or complexed with low levels of Au(III), are attracted at room temperature to commercial magnets, whereas those containing high levels of intercalators or Au(III) are not. This surprising observation is explained by the EPR spectra and SQUID measurement of magnetization of the modified DNAs. It is conjectured that A-DNAs are morphologically heterogeneous containing ordered and disordered regions. The ordered regions appear to strongly mediate magnetic interactions between spins through their ${\pi}_z$-stacked structures. When the modified DNAs are wet or hydrated, they behave diamagnetically.

  • PDF

Improved Perfusion Contrast and Reliability in MR Perfusion Images Using A Novel Arterial Spin Labeling

  • Jahng, Geon-Ho;Xioaping Zhu;Gerald Matson;Weiner, Michael-W;Norbert Schuff
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.341-344
    • /
    • 2002
  • Neurodegenerative disorders, like Alzheimer's disease, are often accompanied by reduced brain perfusion (cerebral blood flow). Using the intrinsic magnetic properties of water, arterial spin labeling magnetic resonance imaging (ASLMRI) can map brain perfusion without injection of radioactive tracers or contrast agents. However, accuracy in measuring perfusion with ASL-MRI can be limited because of contributions to the signal from stationary spins and because of signal modulations due to transient magnetic field effects. The goal was to optimize ASL-MRI for perfusion measurements in the aging human brain, including brains with Alzheimer's disease. A new ASL-MRI sequence was designed and evaluated on phantom and humans. Image texture analysis was performed to test quantitatively improvements. Compared to other ASL-MRI methods, the newly designed sequence provided improved signal to noise ratio improved signal uniformity across slices, and thus, increased measurement reliability. This new ASL-MRI sequence should therefore provide improved measurements of regional changes of brain perfusion in normal aging and neurodegenerative disorders.

  • PDF

Spin-glass behavior in (A,B)-site deficient manganese perovskites

  • Lee, Kyu-Won;Phan, Manh-Huong;Yu, Seong-Cho;Nguyen Chau;Tho, Nguyen-Duc
    • Proceedings of the Korean Magnestics Society Conference
    • /
    • 2003.06a
    • /
    • pp.150-151
    • /
    • 2003
  • In the past years, a giant magnetoresistance (GMR) effect found in perovskite-like structured materials has attracted considerable attention among scientists and manufacturers, since, a practical point of view, the capacity of producing magnetic and sensing sensors. In a stream of this interest, further efforts to understand the underlying mechanism that leads to the GMR effect relative to the correlation between transport and magnetic properties, have been extensively devoted. In these cases, spin-glass-like behaviors are ascribed to the frustration of random competing exchange interactions, namely the ferromagnetic double-exchange interaction between Co$\^$3+/ (or Mn$\^$3+/) and Co$\^$4+/(or Mn$\^$4+/) and the antiferromagnetic one like spins. Noticeably, the distinction of spin-glass region from cluster-glass one, involved in the remarkable changes in transport and magnetic properties at a critical value of doping concentration, was observed. Magnetic anomalies in zero-field-cooled (ZFC) magnetization as well as ac magnetic susceptibility below Curie temperature T$\sub$c/ and the charge/orbital fluctuation were also realized. In this work, we present a study of magnetic properties of a deficient manganese perovskites system of La$\sub$0.6/Sr$\sub$x/MnTi$\sub$y/O$_3$, and particularly provide its new magnetic phase diagram.

  • PDF

4f spin dynamics in TbNi$_2$B$_2$C by $^{11}$B NMR

  • Lee, K.H.;Seo, S.W.;Kim, D.H.;Khang, K.H.;Seo, H.S.;Hwang, C.S.;Hong, K.S.;Cho, B.K.;Lee, W.C.;Lee, Moo-Hee
    • 한국초전도학회:학술대회논문집
    • /
    • v.10
    • /
    • pp.61-64
    • /
    • 2000
  • $^{11}$B NMR measurements have been performed to investigate local electronic structure and 4f spin dynamics for TbNi$_2$B$_2$C single crystal. $^{11}$B NMR spectra show three resonance peaks due to the quadrupolar interaction. Shift and linewidth are huge and strongly temperature-dependent. In addition, both are proportional to magnetic susceptibility, indicating that the hyperfine field at the boron site originates from the 4f spins of Tb. $^{11}$B NMR shift and relaxation rates show high anisotropy for field parallel and perpendicular to the c-axis. Anisotropy of the shift and the relaxation rates suggests that the hyperfine field perpendicular to the c-axis is larger.

  • PDF

Evolution of a Productive Multivoltine x Bivoltine Hybrid, CAUVERY (BL67x CSR101) of Silkworm, Bombyx zori L.

  • Rao, D.Raghavendra;Premalatha, V.;Singh, Ravindra;Kariappa, B.K.;Jayaswal, K.P.
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.4 no.2
    • /
    • pp.121-126
    • /
    • 2002
  • Breeding programme was initiated during November, 1995 with the main objective to breed productive multivoltine breeds/ hybrids with suitable genetic constitution to suit the fluctuating tropical climate prevailed in India. Two multivoltine breeds viz., BL-24 and BL-27 selected were as breeding resource materials from the silkworm germplasm maintained at Central Sericul-tural Research and Training Institute, Mysore. By adopting hybridization, backcrossing inbreeding and selection, a new multivoltine breed namely BL-67. This breed spins light greenish yellow cocoons and cocoon shape is oval with medium to coarse grains. The evolved breed was crossed with five tropical bivoltine breeds viz., NB4D2, CSR2, CSR5, CSR18 and CSR101 to study the combining ability, and identified a superior hybrid, BL67 ${\times}$ CSR101, named as CAUVERY, The hybrid is characterized by high pupation rate (>95%), high shell weight (> 35 cg), high cocoon shell ratio (> 20%), longer filament length (> 900 m) and high neatness (93) with a renditta of 6.5 producing 2A-3A grade silk. The hybrid is selected for Race Autho-rization test of Central Silk Board.