• Title/Summary/Keyword: SP monitoring

Search Result 202, Processing Time 0.022 seconds

Long-term safety of PEG 4000 in children with chronic functional constipation: A biochemical perspective

  • Bae, Sun-Hwan
    • Clinical and Experimental Pediatrics
    • /
    • v.53 no.7
    • /
    • pp.741-744
    • /
    • 2010
  • Purpose: To evaluate the long-term safety of polyethylene glycol (PEG) 4000 in children with constipation, particularly the biochemical aspects of safety. Methods: Medical records were evaluated, and 100 children, who had been taking PEG 4000 for more than 6 months, and who had been under clinical and biochemical monitoring, were enrolled. Ages; $6.11{\pm}3.12$ years, Duration of therapy; $16.93{\pm}7.02$ months, dose of PEG 4000; $0.72{\pm}0.21g/kg/d$. Results: None of the children complained of clinical adverse effect. The first biochemical test was performed at 8.05 months after beginning of PEG 4000. Serum phosphate (SP) value was high in 10 children, and leucopenia was noted in one child. The second test was performed in 44 children at 7.57 months after the first test. The SP value was high in four children, including the three children whose initial SP value was high and one new child. Six out of 10 children with high initial SP value became normal and one was lost. Hypernatremia was noted in one child. The third test was done in 15 children at 7.5 months after the second test. The SP value of the new child from the second test was high, but became normal after finishing treatment. Two out of 3 children with high SP value at the second test became normal and one was lost. The fourth test was done in 2 children few months after the third test. All of the results were normal. There were no relation between duration of therapy and hyperphosphatemia, or between dose of PEG 4000 and hyperphosphatemia. Conclusions: PEG 4000 is safe for long-term therapy in children with constipation with respect to biochemical parameters.

Central Localization of Neurons Projecting to the Uterus and Sanyinjiao(Sp6) (자궁과 삼음교에서 투사하는 충추신경계내 신경원의 표지영역에 관한 연구)

  • 이창현;강윤석;이광규;이상룡;육상원
    • The Journal of Korean Medicine
    • /
    • v.22 no.2
    • /
    • pp.31-40
    • /
    • 2001
  • This experimental studies was to investigate location of labeled neurons in CNS following injection of pseudorabies virus(PRV), Bartha strain, into the uterus and Sanyinjiao(Sp6) of rats. After survival times of 4-5 days following the injection of PRV, the rats were perfused, and their brain and spinal cord were frozen sectioned($30\mu\textrm{m}$). These sections were stained by PRV immunohistochemical staining methods, and observed with light microscope. The results were as follows: 1. In the spinal cord, overlap areas of PRV labeled neurons projecting to uterus and Sp6 were observed in lamina VII, IX and X areas of cervical segments. In thoracic segments, overlap areas were observed in lamina IV, VII, X and intermediolateral n.. In lumbar segments, overlap area of PRV labeled neurons were observed in lamina I, V-VII, IX, X and intermediolateral n.. In sacral segments, overlap areas of PRY labeled neurons were observed in lamina N, V, VII, X and sacral parasympathetic n.. 2. In the brain, overlap areas of PR V labeled neurons projecting to the uterus and Sp6 were observed in lateral paragigantocellular n., rostroventrolateral reticular n., raphe obscurus n., raphe pallidus n., raphe magnus n., locus coeruleus n., Barrington's n., A5 cell group, central gray n., paraventricular hypothalamic n. and arcuate n. This results suggest that overlap areas of PRV labeled neurons of the spinal cord projecting to the uterus and Sp6 might be the first-order neurons related to the viscera-somatic sensory and sympathetic preganglionic neurons. PRV labeled neurons of the brain may be the second and third-order neurons response to the movement of smooth muscle of uterus. These PRV labeled neurons may be central autonomic center related to the integration and modulation of reflex control linked to the sensory and motor system monitoring the internal environment. These overlap areas of spinal cord and brainmay be related to autonomic centers related to regulation of uterus.

  • PDF

Isolation and Partial Characterization of Phytotoxic Mycotoxins Produced by Sclerotinia sp., a Potential Bioherbicide for the Control of White Clover(Trifoliorum repens)

  • Hong, Yeon-Kyu;Lee, Bong-Choon;Jung, Won-Kwon;Bae, Soon-Do;Park, Sung-Tae;Uhm, Jae-Youl
    • The Plant Pathology Journal
    • /
    • v.20 no.1
    • /
    • pp.52-57
    • /
    • 2004
  • Sclerotinia sp. (isolate BWC98-105) causes stem blight and root rot in Leghum sp., and is presently being evaluated as a potential mycoherbicide for the control of Trifoliorium repens. Bioassays have shown that Sclerotinia sp. produces phytotoxic substance which is biologically active against T. repens. Two biologically active compounds, designated as compoundsI and II, were produced in vitro from the culture filtrate of BWC98-105 isolate Sclerotium sp. Compounds I and II were purified by means of liquid-liquid extraction and $C_{18}$ open column chromatography (300 ${\times}$ 30 mm, i.d). To determine the purity, the purified compounds were analyzed by RP-HPLC. The analytical RP-HPLC column was a TOSOH ODS-120T (150 ${\times}$ 4.6 mm i.d, Japan), of which the flow rate was set at 0.7 mL/min using the linear gradient solvent system initiated with 15 % methanol to 85 % methanol for 50 min with monitoring at 254 nm. Under these RP-HPLC conditions, compounds I and II eluted at 3.49 and 4.13 min, respectively. Compound II was found to be most potent and host specific. However, compound I had a unique antibiotic activity against phytopathogenic bacteria like bacterial leaf blight (Xanthomonas oryzae) on rice, where it played a less important role in producing toxicity on T. repens. No toxin activity was detected in the water fraction after partitioning with several organic solvents. However, toxin activity was detected in the ethyl acetate and butanol fractions. In the leaf bioassay using compound II, the disease first appeared within 4-5 h as water soaked rot, which subsequently developed into well-defined blight affecting the whole plant.

Characteristics of Aquatic Environment and Algal Bloom in a Small-scaled Agricultural Reservoir (Jundae Reservoir) (소규모 농업용 전대저수지의 수환경 변화와 조류발생 특성)

  • Nam, Gui-Sook;Lee, Eui-Haeng;Kim, Mirinae;Pae, Yo-Sup;Eum, Han-Young
    • Korean Journal of Environmental Biology
    • /
    • v.31 no.4
    • /
    • pp.429-439
    • /
    • 2013
  • This study was conducted to identify the relationship between environmental factors and algal bloom, and provide information for efficient management based on the results of monitoring the environmental parameters and algal diversity in the Jundai reservoir from March 2011 to October 2013. Little change in the weather conditions was observed during the study period except for a slight decrease in rainfall. Concentration of TN and TP in the reservoir exceeded water quality standards for agriculture and significant correlation between algal growth and environmental factors was observed. Phytoplankton in Jundai reservoir included 6 classes, 40 genus, 62 species, and the phytoplankton abundance was in the range of $1.3{\times}10^4{\sim}2.8{\times}10^6$ cells $mL^{-1}$. The annual average of phytoplankton abundance and Chl-a gradually decreased as TN and TP concentrations decreased. Overall Anabaena sp., Oscillatoria sp., and Microcystis sp. were the dominant species in Jundai reservoir. As the water temperature increased, the dominant species were Anabaena sp., Microcystis sp. and Oscillatoria sp., in that order. Anabaena sp. was dominant from spring to early summer with increase in water temperature and pollutant concentrations, and high correlation with environmental factors was observed. Microcystis sp. was dominant depending on changes in the nutrient levels. In the case of Oscillatoria sp., there was no significant correlation between phytoplankton biomess and Chl-a. However, efficient management of water environment and practical control of algal bloom in small scale reservoir polluted by livestock and farm irrigation should be achieved by identification of the relationship between algal growth and environmental factors.

Implementation of a portable pulse oximeter for SpO2 using Compact Flash Interface (컴팩트 플래쉬 방식의 휴대용 산소포화도 측정 시스템 구현)

  • Lee, Han;Kim, Young-Kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.05a
    • /
    • pp.678-681
    • /
    • 2003
  • In this paper, we aims to develop a microcontroll er-based portable pulse oximeter using Compact Flash Interface. First, portable pulse oxineter system is designed to record 2 channel of biosignals simultaneously, including 1 channel of SpO$_2$ and 1 channel of pulse rate. It is very small and portable. Besides, the system makes it possible to measure a patients condition without an additional medical equipment. We tried to solve the problems generated by a patient's motion. That is, we added an analog circuit to a traditional pulse oximeter in order to eliminate the change of the base line. And we used 2D sector algorithm. As present, SpO$_2$ modules are completed. But there are still many further development needed in order to enhance the function. Especially, compact flash interface remains the most to complete. Second, ECG monitoring system uses almost same as present 3-lead ECG system. But we focus on the analog part, especially in filter. The proposed filter is composed of two parts. One is a filter to remove the power-line interface. The other is a filter to remove the baseline drift. A filter to remove the power-line and the baseline drift is necessarily used in the ECG system. The implemented filter have three features; minimizing the distortion in DC component, removing the harmonic component of power-line frequency. Using compact flash interface, we can easily transfer a patient's personal information and the measured signal data to a network based server environment. That means, it is possible to implement a patient's monitoring system with low cost.

  • PDF

Investigating the potential exposure risk to indium compounds of target manufacturing workers through an analysis of biological specimens (생물학적 노출평가를 통한 타겟 제조업 근로자의 공정별 인듐 노출위험성 조사)

  • Won, Yong Lim;Choi, Yoon Jung;Choi, Sungyeul;Kim, Eun-A
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.3
    • /
    • pp.263-271
    • /
    • 2014
  • Objectives: Along with the several cases of pulmonary disorders caused by exposure to indium that have been reported in Japan, China, and the United States, cases of Korean workers involved in processes that require handling of indium compounds with potential risk of exposure to indium compounds have also been reported. We performed biological monitoring for workers in various target manufacturing processes of indium, indium oxide, and indium tin oxide(ITO)/indium zinc oxide(IZO) in domestic factories. Materials: As biological exposure indices, we measured serum concentrations of indium using inductively coupled plasma mass spectrometry, and Krebs von den Lungen 6(KL-6) and surfactant protein D(SP-D) using enzyme-linked immunosorbent assays. We classified the ITO/IZO target manufacturing process into powdering, mixing, molding, sintering, polishing, bonding, and finishing. Results: The powdering process workers showed the highest serum indium level. The mixing and polishing process workers also showed high serum indium levels. In the powdering process, the mean indium serum concentration in the workers exceeded $3{\mu}g/L$, the reference value in Japan. Of the powdering, mixing, and polishing process workers, 83.3%, 50.0%, and 24.5%, respectively, had values exceeding the reference value in Japan. We suppose that the reason of the higher prevalence of high indium concentrations in powder processing workers was that most of the particles in the powdering process were respirable dust smaller than $10{\mu}m$. The mean KL-6 and SP-D concentrations were high in the powdering, mixing, and polishing process workers. Therefore, the workers in these processes who were at greater risk of exposure to indium powder were those who had higher serum levels of indium, as well as KL-6 and SP-D. We observed significant differences in serum indium, KL-6, and SP-D levels between the process groups. Conclusions: Five among the seven reported cases of "indium lung" in Japan involved polishing process workers. Polishing process workers in Korea also had high serum levels of indium, KL-6, and SP-D. The outcomes of this study can be used as essential bases for establishing biological monitoring measures for workers handling indium compounds, and for developing health-care guidelines and special medical surveillance in Korea.

An Implementation of Wireless Monitoring System for Health Care (헬스 케어를 위한 무선 모니터링 시스템 구현)

  • Eom, Sang-Hee;Nam, Jae-Hyun;Chang, Yong-Hoon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.10a
    • /
    • pp.67-71
    • /
    • 2007
  • Recently, a health care need according to the increase of an advanced age population is increasing. The requirement about a health care monitoring is increasing rapidly from general people as well as patient. The requisition about a medical treatment technique and a medical treatment information service is the trend to be expanding. That can be possible minimizing the inconvenience of the patient to take a medical service and continuously monitoring the status of the patient to take a health care service. This paper discusses an implementation of wireless physiological signal monitoring system for health care. The system are composed of the sensor node and monitoring program. The sensor node has the physiological signal measurement part and the wireless communication part. The remote monitoring system has a monitoring program that are communicating the sensor node using bluetooth. The sensor node measured the ECG, pulse wave, blood pressure, Sp02, and heart rate.

  • PDF

An Implementation of Wireless Monitoring System for Health Care (헬스 케어를 위한 무선 모니터링 시스템 구현)

  • Eom, Sang-Hee;Chang, Yong-Hoon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.8
    • /
    • pp.1401-1407
    • /
    • 2008
  • Recently, a health care need according to the increase of an advanced age population is increasing. The requirement about a health care monitoring is increasing rapidly from general people as well as patient. The requisition about a medical treatment technique and a medical treatment information service is the trend to be expanding. That can be possible minimizing the inconvenience of the patient to take a medical service and continuously monitoring the status of the patient to take a health care service. This paper discusses an implementation of wireless physiological signal monitoring system for health care. The system are composed of the sensor node and monitoring program. The sensor node has the physiological signal measurement part and the wireless communication part. The remote monitoring system has a monitoring program that are communicating the sensor node using bluetooth. The sensor node measured the ECG, pulse wave, blood pressure, SpO2, and heart rate.

Development of a Ring-type Wearable Healthcare Device (반지 형태의 웨어러블 헬스케어 디바이스 개발)

  • Baek, Hyun Jae;Cho, Jaegeol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.7
    • /
    • pp.892-897
    • /
    • 2018
  • Due to population aging, an increase in the number of patients with chronic illnesses, and an increase in the number of single-person households, monitoring of health status in everyday life without the need for a hospital has become very important. For this reason, researches on various health care devices have been attempted, among which wearable devices are attracting much attention. In this paper, we propose a new ring-type wearable device for next generation healthcare. On the inner side of the ring, a metal electrodes for GSR measurement and an optical sensor for measurement of pulse wave signals of two wavelengths of red and near-infrared light were mounted. In addition, it was equipped with an acceleration sensor, and information about the degree of motion could be obtained. In this paper, it is shown that a health monitoring device can be implemented in the form of a ring, and the measured signals can be used to calculate heart rate, oxygen saturation, sleep time and sleep efficiency. Through the advanced algorithm, it is expected that we can extract various health information, especially sleep related health information by using the ring device, and it is also expected that it can contribute to the implementation of wearable healthcare effectively.

Zigbee based 1-ch ECG device with activity monitoring function (지그비를 기반으로 한 운동감시 기능을 가진 1채널 ECG장치 개발)

  • Hong, Joo-Hyun;Kim, Nam-Jin;Cha, Eun-Jong;Lee, Tae-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.41-43
    • /
    • 2005
  • PDA-based monitoring is used to acquire continuously the patient's vital signs, including electrocardiography, activity, heart rate and $SpO_2$. In this paper, A biomedical signal acquisition device was designed using 3-axial MEMS accelerometer and 1-ch ECG amplifier, to have the function of monitoring activity and electrocardiography. The proposed system is composed of transmitter and receiver. Through the Zigbee communication, subject's biosignals can be transmitted in real-time to receiver, and transmitted data confirmed using PDA. The packet size used in this device was set not to exceed a maximum payload size of 116 byte. One packet consists of two segments. The transmission speed was 21 packet per second, 420 ECG samples per second, and 42 acceleration samples per second. The proposed method can be used to develop Activities of Daily Living(ADL} monitoring devices for the elderly or movement impaired people and enables patients to be monitored without any constraints. Also, this method will reduce medical costs in the aged society.

  • PDF