• Title/Summary/Keyword: SOx and NOx

Search Result 205, Processing Time 0.025 seconds

Study on Load Analysis of Propulsion System using SOM (자기조직화지도를 이용한 추진시스템의 전력부하분석 연구)

  • Jang, Jae-Hee;Oh, Jin-Seok
    • Journal of Ocean Engineering and Technology
    • /
    • v.33 no.5
    • /
    • pp.447-453
    • /
    • 2019
  • Recently, environmental regulations have been strengthened for SOX, NOX, and CO2, which are ship exhaust gases. In addition, according to the 4th Industrial Revolution, research on autonomous ship technology has become active and interest in electric propulsion systems is increasing. This paper analyzes the power load characteristics of an electric propulsion ship, which is the basic technology for an autonomous ship, in terms of energy management. For the load analysis, data were collected for a 6,800 TEU container ship with a mechanical propulsion system, and the propulsion load was converted to an electric power load and clustered according to the characteristics using a SOM (Self-Organizing Map). As a result of the load analysis, it was confirmed that the load characteristics of the ship could be explained by the operation mode of the ship.

Co-combustion of coal and RDF in the Fluidized Bed Boiler (유동층 석탄보일러에서 폐기물고형연료 혼소기술 개발)

  • Choi, Yeonseok;Choi, Hangseok;Kim, Seockjoon;Han, Soyoung;Park, Dohyun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.207.1-207.1
    • /
    • 2010
  • The emission difference of SOx, NOx, TSP and dioxine was investigated in commercial CFB boiler, when coal and three kinds of RDFs were co-combusted respectively. The each mixing ratio was 7.5% RPF, 7.5% RDF and 10% SDF with coal. Emitting dioxine concentration was proportioned to the chlorine content of RDF. No trouble was found on normal boiler operation during co-combustion. These RPF, SDF and RDF could be determined to be a good alternative fuel of general coal.

  • PDF

The Study on the Electrical Characteristics of the Pulse Generator adopted Cascading Technique

  • Joung, Jong-Han;Kim, Moon-Hwan
    • Journal of Power Electronics
    • /
    • v.4 no.2
    • /
    • pp.112-116
    • /
    • 2004
  • The pulsed power systems have been widely used many other countries and their new applications have been developed by many researchers, such as E/P(Electrostatic Precipitator) to remove the industrial dust, DeNOx/DeSOx power systems, ozone generators and power sources of the laser beam, etc. In this paper, we studied the cascading technique as a new technology consisted of two pulse transformers and obtained their experimental data and results. To obtain the high pulsed voltage adopted cascading technique, we designed our compact pulse generator and tested by adjusting the value of the load resistors to obtain high pulsed voltage with steep rising time and duration time. We explained their experimental results that obtained by adopting cascading technique. Also, we compared theoretical value with measured value obtained by using the cascading method.

The Study on Arc Suppression of Line-to-Line Electrodes in Air and Removal of the Metaloxide (선대 선 전극방식의 대기압 아크억제 대책 및 Metaloxide 제거에 관한 연구)

  • 정종한;김문환
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.5
    • /
    • pp.264-267
    • /
    • 2004
  • Recently the pulsed power systems have been widely used in many fields such as E/P(Electrostatic Precipitator), DeNOx/DeSOx power systems, ozone generators and power sources of the laser beam. In this paper, we studied various electrical characteristics for arc suppression of line-to-line electrodes in air and removal of the metaloxide using our pulsed power system. To obtain high efficiency of the pulsed power system, we repeatedly experimented and tested their characteristics. by adjusting electrode length of the load. As a result, when the value of the electrode length and pulse repetition rate were changed at the load, the value of the arc voltage changed at the electrode load. In conclusion, we controlled arc voltage of the load by ,changing electrode length and pulse repetition rate. Also. we stydied removal area of the metaloxide using area discharge according to pulse repetition rate.

Study on the Criteria of Raw Materials for RDF (폐기물 고형연료(RDF)의 원료 기준 연구)

  • Nho, Namsun;Shin, Daehyun;Bae, Dalhee;Kong, Seungdae;Cho, Seoyoung;Kim, Kwangho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.187.1-187.1
    • /
    • 2011
  • RDF(Refuse-Derived Fuel) is a fuel of pelletized form made of combustible solid wastes and can not only be used as alternative energy to fossil fuel but also solve troubles in thermal uses of incinerator. As the first stage for obtaining elementary data required to develop criteria of raw materials appropriate to RDF combustion facilities actively spread recently in Korea, preliminary experiments were conducted on CO, SOx, NOx and HCl production and reduction characteristics in combustion of RDF. RDF samples weighing 2~3 g per a sample were manufactured in a lab-scale way and combustion tests of RDF were carried out in electric furnace with quartz tube of 50 mm inside diameter.

  • PDF

A Study on the Removal of SOx/NOx by a Pulsed Corona Discharge in the Wire-Plate Reactor (Wire-Plate 반응기에서 펄스 코로나 방전을 이용한 탈황 탈질에 관한 연구)

  • Shin, Wan-Ho;Song, Yong-Hoon;Kim, Han-Seok;Choi, Yeon-Seok;Kim, Seok-Joon
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1910-1912
    • /
    • 1996
  • This paper presents the results of laboratory experimentals to remove $SO_2$ and $NO_x$ by a pulsed corona discharge in the wire-plate reactor. A rotating spark gap switch was used to generate the pulse by chewing the dc high voltage. Repetition frequency of the pulse was 60Hz and rising time of 50ns. The photo pictures of positive streamer corona taken by ICCD camera, pulse voltage and current were measured using a digital oscilloscope. Simultaneous effects of $C_{2}H_{4}$ injection and heterogeneous chemical reactions on nonthermal plasma process to remove $SO_2$ and $NO_x$ from flue gas were investigated in the present study

  • PDF

Study of the Environment Priority Facility Operation Concept of 500MW Standard Coal Thermal Power Plant (500MW 표준석탄화력발전소의 환경안전우선 설비운영개념 도입방안 고찰)

  • Lee, Kab-Ju;Chung, Jin-Do;Kim, San
    • Journal of the Korea Safety Management & Science
    • /
    • v.24 no.2
    • /
    • pp.1-9
    • /
    • 2022
  • In korea, 500MW standard coal fired power plants were designed and operated for the initial base load, so facility stability was prioritized from facility problem to treatment, but now we needed to research for minimizing greehouse gas emissions at the operation of coal fired power plants. research on various facilities and technologies was actively conducted to reduce environment pollutants was drastically reduced, but research and attempts on coping measures in the event of a reduction facility problem were in sufficient. this study considered investigated ways to minimized pollutants by quickly responding to logic development and application of the load runback concept in case of serious problems with environmental pollutant reduction facilities such as NOx reduction selective catalytic reduction facilities, SOx reduction wet flue gas desulpherisation facilities, and TSP(Total Suspended Particles) collection low temperature electric precipitator.

Preparation of Novel Sorbents for Gas-phase Mercury Removal

  • Lee, Si-Hyun;Rhim, Young-Jun;Park, Young-Ok
    • Carbon letters
    • /
    • v.3 no.4
    • /
    • pp.187-191
    • /
    • 2002
  • In the present research, we prepared the activated carbon (AC) sorbents to remove gas-phase mercury. The mercury adsorption of virgin AC, chemically treated AC and fly ash was performed. Sulfur impregnated and sulfuric acid impregnated ACs were used as the chemically treated ACs. A simulated flue gas was made of SOx, NOx and mercury vapor in nitrogen balance. A reduced mercury adsorption capacity was obtained with the simulated gas as compared with that containing only mercury vapor in nitrogen. With the simulated gas, the sulfuric acid treated AC showed the highest performance, but it might have the problem of corrosion due to the emission of sulfuric acid. It was also found that the high sulfur impregnated AC also released a portion of sulfur at $140^{\circ}C$. Thus, it was concluded that the low sulfur impregnated AC was suitable for the treatment of flue gas in terms of stability and efficiency.

  • PDF

A Study on the Pulse Peak Voltage and Cascading Ratio of Compact Pulse Generator using Cascading Method (Cascading 방식을 적용한 펄스발생기의 펄스전압 변성 및 Cascading 비율 특성)

  • Joung, Jong-Han;Kim, Hee-Je
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.7
    • /
    • pp.329-333
    • /
    • 2001
  • The pulsed poser system has been widely used to many applications, such as E/P(Electrostatic Precipitator), DeNox/DeSOx power system, ozon generator, etc. A pulse energy efficiency for load depends on the rising time, peak value, pulse duration and impedance matching, etc. The pulse generator generally required for short pusle duration and high peak value was forced to consider its volume and economy. In this study, developing a compact pulse generator that applied for cascading method to be made of two pulse transformers, we compared cascading voltage with non cascading one by applying the pulse energy to load. Adopting cascading technique to pulse transformer, we found that average cascading voltage was about 60[%] of theoretical value. Maximum cascading ratio was calculated at 60 times compared with non cascading voltage.

  • PDF

$CO_2$ absorption of alkaline salt in the pre-combustion condition (연소전 조건에서 알칼리염계 흡수제의 $CO_2$ 흡수특성)

  • Oh, Myoung-Seok;Back, Guen-Ho;Cha, Wang-Seog
    • Proceedings of the KAIS Fall Conference
    • /
    • 2008.11a
    • /
    • pp.394-396
    • /
    • 2008
  • 주요 온실가스인 이산화탄소를 회수 및 저장(Carbon Capture and Storage)하는 기술은 주로 적은 $CO_2$농도를 가지는 연소후 포집공정이 개발 및 적용되었으나, 최근에는 보다 적극적으로 이산화탄소를 분리하기 위하여 연소전 석탄가스화복합발전(IGCC)과 같은 공정에 적용하여 반응공정 중에 생성되는 높은 농도의 $CO_2$를 분리하는 공정이 선진국을 중심으로 활발히 연구가 진행되고 있다. 본 연구에서는 고압의 연소전 조건에서 아민계보다 흡수속도는 느리나 생성가스에 유입되는 $O_2$, SOx, NOx에 의한 부반응 현상, 휘발에 의한 손실, 열적 열화현상이 나타나지 않는 알칼리염계 흡수제의 $CO_2$ 흡수특성에 대하여 연구하였다.

  • PDF