• Title/Summary/Keyword: SOx and NOx

Search Result 205, Processing Time 0.027 seconds

An Ozone-based Advanced Oxidation Process for an Integrated Air Pollution Control System (복합대기오염 저감 시스템을 위한 오존 고속산화 기반 고도산화공정)

  • Uhm, Sunghyun;Hong, Gi Hoon;Hwang, Sangyeon
    • Applied Chemistry for Engineering
    • /
    • v.32 no.3
    • /
    • pp.237-242
    • /
    • 2021
  • Simultaneous removal technologies of multi-pollutants such as particulate matters (PMs), NOx, SOx, VOCs and ammonia have received consistent attention due to the enhancement of pollutant abatement efficiency in addition to the stringent environmental regulation and emission standard. Pretreatment of insoluble NO by an ozone oxidation can be considered to be more effective route for saving space occupation as well as operation cost in comparison with that of traditional selective catalytic reduction (SCR) process. Moreover the primary advantage of ozone oxidation process is that the simultaneous removal with acidic gas including SOx is also available. Herein, we highlight recent studies of multi-pollutant abatement via ozone oxidation process and the promising research topics for better application in industrial sectors.

Beneficiation of Low Grade Anthracites (저품위 무연탄의 처리에 관한 연구)

  • 이재장;전호석;최우진
    • Resources Recycling
    • /
    • v.5 no.2
    • /
    • pp.45-51
    • /
    • 1996
  • Domestic coal contains approximnlely 03 to 7 percentage of sulfur. When the suliur in coal is burned, exhaust gas , nay be thc causc of air pollution problcms as well as acid rain. Thc government dccideil lo strengthen the environmcnlal protection policy a1 the 270 ppm of SO, for the coal-Ered plants and to stari in Ian. 1, 1999. This study was carried out lo rcmove the stlfur and mineral mancrs in the samplw using wet msg~xiic separatol ant1 oil agglomeration apparatus. The rcsults for the wet magnetic separalion showed that the total sulfur removal from Kangnung coal sample was 60.8% with 82.6% combustible recovery. For the results of oil agglomeration testa, combustible recavety, ash nod sulfur rcmovcl horn Maro coal sample were 98.0, 70.9 and 95.7 percent, respectively.

  • PDF

Vitrification of Simulated Combustible Dry Active Wastes in a Pilot Facility

  • Yang, Kyung-Hwa;Park, Seung-Chul;Lee, Kyung-Ho;Hwang, Tae-Won;Maeng, Sung-Jun;Shin, Sang-Woon
    • Nuclear Engineering and Technology
    • /
    • v.33 no.4
    • /
    • pp.355-364
    • /
    • 2001
  • In order to evaluate and finally optimize the vitrification condition for combustible dry active waste (DAW), dust and gas generation characteristics were investigated for PE, cellulose, and mixed waste Tests were conducted by varying the operation variables such as melter configuration, excess oxygen amount, and waste feeding rate. Results showed that dust generation characteristics were affected by the operation parameters and the melter's configuration is the dominant one. For all tested DAWs, dust generation was reduced by increasing the waste feeding rate and the excessive oxygen amount in the melter. Among waste types, dust amount was decreased by the order of mixed wastes, PE, and cellulose. Other parameters such as temperature variation and operation time have also affected the dust generation. The optimum condition for the DAW vitrification was determined as the melter's configuration equipped for minimizing the waste dispersion with 20 kg/h of waste feeding rate and 100% of excessive oxygen supply. CO gas concentration in the off-gas was immediately influenced by the combustion state in the melter, but showed similar trend as the dust generation. For the NOx production during the vitrification process, thermal NOx, which is generated from the Post Combustion Chamber (PCC), rather than fuel NOx was assumed to be dominant. The gas cleaning of efficiencies of the PCC, wet scrubber, and Selective Catalytic Reduction system (SCR) were found to be high enough to keep the concentration of pollutants (CO, NOx, SOx, HCI) in the stack below their relevant emission limits.

  • PDF

Analysis of Combustion Air Flow in Incinerator (소각로의 연소 공기 유동 해석)

  • Lee, Dong-Hyuk
    • Design & Manufacturing
    • /
    • v.16 no.2
    • /
    • pp.26-32
    • /
    • 2022
  • It is known that the fluidized bed incinerator, which is the subject of analysis, shows excellent performance in heat and mass transfer due to excellent mixing and contact performance between fluidized sand and fuel, and also shows relatively good combustion characteristics thanks to good mixing and long residence time for low-grade fuels. have. In this study, air flow analysis is performed to understand the characteristics of co-firing of sludge, waste oil and solid waste in the fluidized bed incinerator, flow characteristics of flue gas, and discharge characteristics of pollutants.The fluidized bed incinerator subject to analysis is a facility that incinerates factory waste and general household waste together with sludge, with a processing capacity of 32 tons/day. to be. In addition, the operation method was designed for continuous operation for 24 hours. As a result, it can be seen that the lower combustion air and the introduced secondary air are changed to a strong turbulence and swirl flow form and exit through the outlet while rotating inside the freeboard layer. The homogeneous one-way flow form before reaching the secondary air nozzle has very high diffusivity with the high-speed jet flow of the nozzle.

Combustion Characteristics of Coal and Wood Biomass Co-Firing on the Pulverized Coal Combustion Furnace (목질계 바이오매스와 유연탄의 혼합 연소특성에 관한 연구)

  • Kim, Sung-Chul;Lee, Hyun-Dong;Kim, Jae-Gwan
    • 한국연소학회:학술대회논문집
    • /
    • 2006.10a
    • /
    • pp.293-298
    • /
    • 2006
  • There are many researches in progress on co-firing of coal and biomass to reduce carbon dioxide produced from the coal consumption. This study carried out 200 Kg/h combustion test furnace by mixing coal with timber. Coal was mixed with domestic and imported-wood around 10% to 20% based on input energy. For the mixed fuel, combustion temperature, unburned carbon and the composition of flue gas were analyzed. In addition, the tendency of slagging and fouling was examined using a probe. According to the result of the experiment, combustion temperature was depended on the kind of wood and mixing ratio. The unburned carbon loss was higher with increase of wood biomass mixing ratio, as a result, the total heat loss of furnace was slightly increased. The emission of NOx and SOx were decreased by $3{\sim}20%$ and $21{\sim}60%$ respectively. There are no difference of slagging and fouling tendency between biomass co-firing and coal burning only.

  • PDF

The Status of DME Development and Utilization as a Fuel (DME 연료 생산 및 이용기기의 개발현황)

  • Baek, Young-Soon;Cho, Won-Jun;Oh, Young-Sam
    • Journal of Energy Engineering
    • /
    • v.16 no.2
    • /
    • pp.73-82
    • /
    • 2007
  • World energy demand has been dramatically increasing because of using much energy of developing countries in Asia. The other side, conventional fossil fuels supply has been gradually decreasing due to the limitation of fossil fuel reserves and changing to the use of environmental-friendly energy for prevention the emission of carbon dioxide, NOx and SOx. Based on these times and status, we get the n necessity of the conversion of environmental-friendly energy and the high effective utilization of conventional and unconventional energy. Recently, promised DME fuel as environmental-friendly and substituted oils will be introduced the status of technology and market in domestic and foreign.

Optimization of wastewater electrolysis using life cycle assessment and simulated annealing

  • Chun Hae Pyo;Chon Hyo-Taek;Kim Young Seok
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2003.11a
    • /
    • pp.518-521
    • /
    • 2003
  • LCA (Life Cycle Assessment), that unifies the scale of various environmental impacts, and simulated annealing are applied to optimizing electrolysis of wastewater from PCB (Printed Circuit Board) production. The changes of environmental impact can be quantified with LCA and the total changes of environmental impacts can be expressed as a function of power consumed, Cu recycled, $Cl_2$, NOx and SOx discharged through restriction of feasible reactions. In a single-variate condition, the environmental optimum can be easily obtained through plotting and comparing each environmental impact value. In 8V potentiostatic electrolysis, the lowest environmental impact can be achieved after 90min. To optimize a multi-variate conditional system, simulated annealing can be applied and this can give the quick and near optimum in complex systems, where many input and output materials are involved, through experimentally measured values without a theoretical modeling.

  • PDF

Study on Optimization of Bioheavy Oil Combustion and Conversion Control System in a Heavy Generation Power Plant (B.C유 전소발전소에서 바이오중유 혼소·전소시 제어시스템 최적화 방안 고찰)

  • Lee, Kabju;Chung, Jindo
    • The Journal of Korea Robotics Society
    • /
    • v.17 no.1
    • /
    • pp.93-101
    • /
    • 2022
  • Bioheavy oil, which is expanding its range of use as an alternative fuel to reduce environmental pollutant emissions, has a lot of difficulty in combustion due to its low emission of pollutants such as nitrogen oxide (NOx) and sulfur oxide (SOx), while its low dissipation and high oxygen content in fuel. many studies have been conducted on change in characteristics by mixing rate combustion characteristics and combustion reactions, but there have been no specific and effective studies on the composition of control system, optimization of control, development of logic for mixing and burning, minimizing environmental pollutantants discharge. In this study, we intend to consider systemmatic and empirical considerations on the composition, logic development, solve the problem of manual switching of bioler master due to excessive oxygen content and tuning of the control system for optimal combustion of bioheavy oil.

Circulting Fluidized Bed Combustion of Refuse Derived Fuel and Steam Production (폐기물 고형연료(RDF)의 순환유동층 연소 및 증기생산)

  • Shun, Do-Won;Bae, Dal-Hee;Cho, Sung-Ho;Lee, Seung-Yong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.613-616
    • /
    • 2007
  • A pilot scale circulating fluidized bed for refuse derived fuel is developed and constructed in order to demonstrate efficient and safe utilization of waste fuel. The capacity of the facility is 8 steam tons per hour with the steam quality of $450^{\circ}C$ and 38atm. The quantity and the quality of the produced steam is sufficient to produce 1MWe power capacity. The test operation proved the high combustion efficiency of 99% and up. The emissions of NOx, SOx in flue gas are below 100, 60ppm respectively with out any emission control. HCl emissions were above 400ppm at the combustor exit but reduced below 10ppm after scrubber.

  • PDF

The EMTP Analysis and Characteristics of Load Impedance on Various Electrode length, Pulse Repetition in Pulse Corona Discharging (펄스코로나 방전의 전극길이, 펄스반복율에 따른 부하 임피던스 변화 특성 및 EMTP 해석)

  • Jeong, Jong-Han;Song, U-Jeong;Jeon, Jin-An;Jeong, Hyeon-Ju;Hong, Jeong-Hwan;Kim, Hui-Je
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.4
    • /
    • pp.158-163
    • /
    • 2002
  • The pulsed Power system has been widely used to many applications, such as E/P(Electrostatic Precipitator), DeNOx/DeSOx power system, often generator, etc. In this paper, we study EMTP analysis and characteristics of critical voltage and load in impedance on various electrode length of pulse corona. To obtain a stable pulse voltage, we designed a compact pulse generator switched MOSFET and tested their characteristics by adjusting electrode length and pulse repetition. As a re sult, critical voltage of pulse corona and load impedance on increasing electrode length were decreased. These results indicate we can control critical voltage of pulse corona and suppress arc discharging between two electrodes.