• Title/Summary/Keyword: SOCKET

Search Result 710, Processing Time 0.027 seconds

Design of Cooling System of Over-molding Mold for Socket Component of Automobile Wiper (자동차 와이퍼 소켓 부품 제작용 오버몰딩 금형의 냉각 시스템 설계)

  • Lee, Dong-Gi;Park, Min-Woo;Ahn, Dong-Gyu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.12
    • /
    • pp.1635-1640
    • /
    • 2011
  • The objective of this study is to design of a cooling system of the over-molding mold for a socket component of an automobile wiper by performing numerical analyses. Hot spots in which the temperature distributions are higher than those of other region, were estimated by an initial over-molding analysis for the initial design of the mold. On the basis of the initial over-molding analysis, two types of cooling system designs with a linear cooling channel and a volumetric heat sink, were considered to improve the cooling characteristics of hot spots. To obtain an appropriate cooling system design, the effects of the diameter and the position of the linear cooling channels on the cooling characteristics and the product qualities were quantitatively examined. In addition, the effects of the design of the volumetric heat sink on the cooling characteristics and deformation distributions in the molded product were investigated. The results of the over-molding analysis of the two types of cooling systems showed that the multi-sliced over-molding mold with a volumetric heat sink can improve both the product quality and the cooling characteristics of the mold.

Comparative, randomized, double-blind clinical study of alveolar ridge preservation using an extracellular matrix-based dental resorbable membrane in the extraction socket

  • Chang, Hyeyoon;Kim, Sulhee;Hwang, Jin wook;Kim, Sungtae;Koo, Ki-Tae;Kim, Tae-Il;Seol, Yang-Jo;Lee, Yong-Moo;Ku, Young;Lee, Jong-Ho;Rhyu, In-Chul
    • Journal of Periodontal and Implant Science
    • /
    • v.47 no.3
    • /
    • pp.165-173
    • /
    • 2017
  • Purpose: The aim of this study was to radiographically and clinically compare the effect of extracellular matrix (ECM) membranes on dimensional alterations following a ridge preservation procedure. Methods: One of 2 different ECM membranes was applied during a ridge preservation procedure. A widely used ECM membrane (WEM; Bio-Gide, Geistlich Biomaterials, Wolhusen, Switzerland) was applied in the treatment group and a newly developed ECM membrane (NEM; Lyso-Gide, Oscotec Inc., Seongnam, Korea) was applied in the control group. Cone-beam computed tomography (CBCT) scans and alginate impressions were obtained 1 week and 6 months after the ridge preservation procedure. Results were analyzed using the independent t-test and the nonparametric Mann-Whitney U test. Results: There were no significant differences between the ECM membranes in the changes in the dimension, width, and height of the extraction socket or the quantity of bone tissue. Conclusions: The NEM showed comparable clinical and radiographic results to the WEM following the ridge preservation procedure.

CPVC Valve Tightening Torque Impact Sockets on the Leaks (CPVC 밸브소켓 체결토크가 누수발생에 미치는 영향)

  • Lim, Chun-Ki;Baek, Eun-Sun
    • Fire Science and Engineering
    • /
    • v.30 no.4
    • /
    • pp.46-58
    • /
    • 2016
  • In this study, the stress applied to screw section, strain, displacement, von Mises stress, and the compression stress applied to the rubber packing for watertightness are estimated with computer simulation when the tightening torque of valve socket is in the range of $10{\sim}130N{\cdot}m$ in order to analyze the influence of valve socket screw section in accordance with the excessive tightening which is supposed to be the cause of water leakage from the synthetic resin piping for fire fighting application of sprinkler equipment, and for the sake of verifying this, adequate value of tightening torque and the value of the compression stress of rubber packing are investigated by examining the number of connected thread for each tightening torque, the deformation state of valve socket and rubber packing and conducting the water hammering test. The result of this test is expected to be utilized as the data required for revising the standard or technical criteria to prevent the water leakage of the synthetic resin piping for fire fighting application.

Clinical study of guided bone regeneration of extracted socket with PLA/PGA membrane and silk fibroin membrane (PLA/PGA 차폐막과 실크 피브로인 차폐막을 이용한 발치와의 골유도재생술의 비교연구)

  • Hwang, Woo-Jin;Jeong, Seong-Nyum;Kim, Yun-Sang;Pi, Sung-Hee;You, Hyung-Keun;Chung, Chong-Pyoung;Shin, Hyung-Shik
    • Journal of Periodontal and Implant Science
    • /
    • v.39 no.2
    • /
    • pp.129-138
    • /
    • 2009
  • Purpose: This study was designed to compare the bond regeneratiom effects of treatment using silk fibroin membrane ( Nanogide-S$^{(R)}$ ) resorbable barrier with control group treated by polyactic acid / polylacticglycolic acid membrane(Biomesh$^{(R)}$ ) Methods: 44 severe bone loss on extraction socket from 44 patients were used in this study. In experimental group 22 sites of them were treated by silk fibrin membrane as and the other 22 sites were treated by polyactic acid/ polylacticglycolic acid membrane as a control group. Clinical parameters including recovered bone width, length and radiographic parameter of vertical length were evlauated at base line and 3 months after surgery. Results: 1) Severe bone width, length was significantlly decreased in two group. 2) Bone width, length was significantlly decreased in two group. 3) Decreased bone width, length and radiographic examination differences between group. Conclusions: On the basis of these results, silk fibrin resorbable membrane has similar bone regeneration ability to polyactic acid / polylacticglycolic acid membrane in guided bone regeneration for severe bone loss defect on extraction socket.

Prediction of the Shaft Resistance of Pile Sockets (암에 근입된 말뚝의 주면저항력 예측)

  • Seidel, J.P.;Cho, Chun-Whan
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.5
    • /
    • pp.281-293
    • /
    • 2002
  • Empiricism has characterized the traditional methods of pile design; in essence, pile design recommendations are based on the accumulated knowledge of pile behaviour based on the construction and subsequent load testing of piles in soil and rock. In this paper, the traditional approaches to design of piles in rock will be briefly reviewed. It will be shown that the unrelated empirical relationships developed fur rock lead to considerable uncertainty in the design of piles. A new method for predicting the shaft resistance of piles socketed into rock, and based on fundamental principles is outlined. It is shown that the shaft resistance predictions of this method agree well with the field test data for rock and hard soil. It is demonstrated by way of a limited parametric study that shaft roughness and socket diameter are critical factors in the performance of piles constructed in these materials. The application of the method to piles socketed into the granites and gneisses of Korea is discussed by way of a case study and by reference to recent direct shear tests on these rocks.

An Improvement of Hospital Reception System using Web Socket (웹소켓을 이용한 병원 접수시스템 개선에 관한 연구)

  • Son, Man-Geun;Park, Ki-Seong;Kong, Yong-Hae
    • Journal of the Korea Society of Computer and Information
    • /
    • v.20 no.1
    • /
    • pp.185-195
    • /
    • 2015
  • During hospital peak times of outpatients, an effective mechanism that informs the newly receipted patient information to corresponding medical departments is lacking in current hospital reception systems. Since every department repeatedly searches entire patient reception database in sequential manner to acquire its reception information, this is a significant performance degradation factor in hospital information system. To improve hospital reception system efficiency, we developed two web socket based systems, a primary key transmitting batch system and a reception information transmitting real time system. The former reduced database access time compared to sequential search system as well as kept search time low regardless of receipted patient number. The latter effectively reduced waiting list updating time in request/response patient reception system by eliminating database access.

A Study on DDS (Data Distribution Service) Application for Real-time Monitoring and Control in Operation Console of the Railway Safety Control Platform (철도 안전관제 통합콘솔에서의 실시간 감시 및 통제를 위한 DDS 적용방안 연구)

  • So, Jaegeol;Shin, Kwang-Ho;Ahn, Jin
    • Journal of The Korean Society For Urban Railway
    • /
    • v.6 no.4
    • /
    • pp.279-286
    • /
    • 2018
  • Recently, a safety control platform to monitor the safety of train operation in real time and prevent accidents and risks through control is under study. In the initial design, DDS communication method supporting distributed network is adopted for real-time processing of large amount of data according to the integration of existing distributed safety data. However, communication between server and console inside the safety control platform is applied to existing TCP socket communication. In the case of TCP socket communication, it is possible to process data for a small system of a safety control test bed by one-to-one communication. However, if the data is expanded all over the country in the future, it becomes difficult to cope with a case where communication traffic occurs due to vast amount of data. In this paper, we propose DDS communication method to support distributed network between server and console of security control platform, and demonstrate TCP socket and DDS method, and compare throughput and speed. As a result, we have found that the scalability and flexibility are improved in case of applying DDS communication to future systems.

Post-extraction pain in the adjacent tooth after surgical extraction of the mandibular third molar

  • Park, Won-Jong;Park, Il Kyung;Shin, Kyung Su;Choi, Eun Joo
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.19 no.4
    • /
    • pp.201-208
    • /
    • 2019
  • Background: After tooth extraction, pain due to dry socket and pain in the adjacent tooth are common. The aim of this study was to retrospectively analyze pain in the adjacent tooth after surgical extraction of the mandibular third molar. Methods: Postoperative pain due to dry socket, pain in the adjacent tooth, and pain from other causes were present. Group A included patents with dry socket alone; group B included patients with pain in the adjacent tooth alone; and group C included patients with both. The duration of symptoms was recorded. In addition, the prognosis of pain was divided into the complete improvement, improvement, maintenance, deterioration, and complete deterioration groups. Results: A total of 312 mandibular third molars were extracted from 13, 60, and 10 patients in groups A, B, and C, respectively. The mean duration of symptoms was 5 days in group A and B and 15.2 days in group C. There were statistically significant differences in the duration of symptoms between groups A and C and groups B and C. Conclusion: Pain in the adjacent tooth after third molar extraction can be caused by inflammatory reactions and pressure on this tooth. The pain caused by pressure on the periodontal ligament and alveolar bone results from the cytokines released by osteoclasts, which are responsible for bone destruction. However, pain from periodontal ligament damage caused by excessive pressure may be misunderstood as pulpal pain. Unconscious parafunctional habits, such as clenching and bruxism, could also be associated with post-extraction pain.

Is treatment with platelet-rich fibrin better than zinc oxide eugenol in cases of established dry socket for controlling pain, reducing inflammation, and improving wound healing?

  • Paul, Sam;Choudhury, Rupshikha;Kumari, Nandini;Rastogi, Sanjay;Sharma, Ashish;Singh, Vikas;Laskar, Shyamalendu;Dubey, Tushar
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.45 no.2
    • /
    • pp.76-82
    • /
    • 2019
  • Objectives: To appraise the effectiveness of platelet-rich fibrin (PRF) in the management of established dry socket in terms of pain, inflammation, and wound healing. Materials and Methods: Two hundred patients with established alveolar osteitis were studied to determine the efficacy of PRF and zinc oxide eugenol (ZOE) for pain control, inflammation reduction, and wound healing. Patients were randomly allocated to Group A (PRF) or Group B (ZOE). Patients were examined on the 1st, 3rd, 7th, and 14th postoperative day and evaluated for pain using visual analogue scale scores, inflammation with a gingival index score, and wound healing through a determination of the number of bony walls exposed. Results: Group A showed better results in terms of pain remission, control of inflammation, and wound healing compared to Group B. Results between groups were statistically significant (P<0.05). Conclusion: PRF is a better alternative than ZOE for the effective management of alveolar osteitis.

A Study on Ring Buffer for Efficiency of Mass Data Transmission in Unstable Network Environment (불안정한 네트워크 환경에서 대용량 데이터의 전송 효율화를 위한 링 버퍼에 관한 연구)

  • Song, Min-Gyu;Kim, Hyo-Ryoung
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.6
    • /
    • pp.1045-1054
    • /
    • 2020
  • In this paper, we designed a TCP/IP based ring buffer system that can stably transfer bulk data streams in the unstable network environments. In the scheme we proposed, The observation data stream generated and output by each radio observatory's backend system as a UDP frame is stored as a UDP packet in a large capacity ring buffer via a socket buffer in the client system. Thereafter, for stable transmission to the remote destination, the packets are processed in TCP and transmitted to the socket buffer of server system in the correlation center, which packets are stored in a large capacity ring buffer if there is no problem with the packets. In case of errors such as loss, duplication, and out of order delivery, the packets are retransmitted through TCP flow control, and we guaranteed that the reliability of data arriving at the correlation center. When congestion avoidance occurs due to network performance instability, we also suggest that performance degradation can be minimized by applying parallel streams.