• Title/Summary/Keyword: SOCKET

Search Result 710, Processing Time 0.027 seconds

A near control technology using high frequencies in audible frequency between smart devices

  • Chung, Myoungbeom
    • Journal of the Korea Society of Computer and Information
    • /
    • v.20 no.8
    • /
    • pp.61-67
    • /
    • 2015
  • The existing methods for control between smart devices in near used Bluetooth, WiFi-Direct, or socket communication using Wi-Fi. However, those have a problem that can not use when operating system of each smart devices is different or when socket server is not working. In this paper, we proposed a new near control technology using High frequencies in audible frequency between smart devices to supplement the problem of existing methods. High frequencies use micro-phone and speaker of smart device and are a control signals that is combined high frequencies within 18kHz ~ 22kHz among audible frequency range. The proposed technology using High frequencies do not need any extra communication modules or socket servers and can use the most smart devices without operating system of devices. To evaluate the performance of the proposed technology, we developed a music play and music control application applied the proposed technology and tested a control experiment using the developed applications. The control success rate was 97% and recognition rate of surrounding people about using high frequencies was under 5%. Therefore, the proposed technology will be the useful technology to control between smart devices in near.

Factors Affecting Primary Stability on Sites of Alveolar Ridge Preservation Using Porcine-derived Bone Minerals

  • Lee, Su-Yeon;Lee, Young;Choi, Seong-Ho;Lee, Dong-Woon
    • Journal of Korean Dental Science
    • /
    • v.14 no.1
    • /
    • pp.1-11
    • /
    • 2021
  • Purpose: The alveolar ridge preservation (ARP) is widely conducted for implant placement. However, experimental results using deproteinized porcine bone mineral (DPBM) have been scarce. This retrospective study evaluated factors affecting the primary stability of implants in an area where ARP was performed using DPBM. Materials and Methods: Thirty-eight patients were divided into two groups based on the primary stability, with torque value of 30 Ncm as borderline. To determine the factors that affect the primary stability of implants, we collected data from patients' medical records including age, sex, reentry time, socket location, remaining bone wall at the time of extraction, and type of collagen membrane, as well as from radiographs and histomorphometric analysis. Result: The results showed statistically significant difference for the remaining extraction socket wall (P=0.014), residual graft (P=0.029), and fibrovascular tissue (P=0.02) between the two groups. There was an insignificant tendency toward the time of reentry surgery (P=0.052) and location (P=0.077). All implants placed in sites using DPBM functioned well up to 3 years. Conclusion: Within the limitations of the present study, extraction socket wall, residual graft, and fibrovascular tissue can affect the primary stability at the time of implant placement on grafted sites using DPBM and collagen membranes. In addition, reentry time and locations can be considered. In future studies, comparative experiments in quantified models will be required to supporting the findings.

The influence of membrane exposure on post-extraction dimensional change following ridge preservation technique (차폐막 노출이 발치 후 치조제 보존술의 결과에 미치는 영향에 관한 임상적 연구)

  • Nam, Hyun-Wook;Park, Yoon-Jeong;Koo, Ki-Tae;Kim, Tae-Il;Seol, Yang-Jo;Lee, Yong-Moo;Gu, Young;Rhyu, In-Chul;Chung, Chong-Pyoung
    • Journal of Periodontal and Implant Science
    • /
    • v.39 no.3
    • /
    • pp.367-373
    • /
    • 2009
  • Purpose: Following tooth extraction caused by severe periodontitis, alveolar ridge dimension lose their original volume. To reduce the alveolar ridge dimension, the ridge preservation technique has been introduced and tested in many clinical studies with membrane alone or membrane plus graft, achieving reduced ridge loss compared to extraction only. The aim of the present clinical study was to compare the post-extraction dimensional changes in the membrane exposure group to non-exposure group during healing period following ridge preservation technique. Methods: Ridge preservation was performed in 44 extraction sites. After extraction, deproteinized bovine bone mineral coated with synthetic oligopeptide (Ossgen-$X15^{(R)}$) or deproteinized bovine bone mineral (Bio-$Oss^{(R)}$) was implanted into the socket. A collagen membrane (Bio-$Gide^{(R)}$) was trimmed to cover the socket completely and applied to the entrance of the socket. Four clinical parameters were compared between baseline and 6 months. Results: During healing period, membrane exposure was observed at 19 sites. At the re-entry, hard newly formed tissue were observed at the ridge preservation site. The grafted socket sites were well preserved in their volume dimension. In both groups, horizontal ridge width was reduced and vertical height was increased. There were not statistically significant differences in horizontal (-1.32 mm vs -1.00 mm) and vertical ridge change (2.24 mm vs 2.37 mm at buccal crest, 1.36 mm vs. 1.53 mm at lingual crest) between two groups. Conclusions: The ridge preservation approach after tooth extraction effectively prevented resorption of hard tissue ridge in spite of membrane exposure during healing period.

Multibody Analysis of a Push-Push Type Mechanism for Micro SIM Card Socket (Micro SIM Card Socket에 사용된 Push-Push Type 기구의 다물체동역학 해석)

  • Choi, Chan Kyu;Kim, Ju Chul;Yun, Ju Young;Sim, Jung Kil;Yoo, Hong Hee
    • Transactions of the KSME C: Technology and Education
    • /
    • v.1 no.1
    • /
    • pp.1-6
    • /
    • 2013
  • A SIM card socket is used for a cell phone to fix an USIM card and a push-push mechanism is typically employed in the SIM card socket for a user convenience. A SIM card is inserted with locking when a user pushes the card once and a SIM card is removed with unlocking when a user pushes the card again. A push-push mechanism is operated by a heart-cam structure and a main spring. A cam slider and a cam stick consisting a push-push mechanism may be broken because of the main spring. So, dynamic stress at a cam slider and a cam stick which is generated by a main spring during operating should be analyzed and considered in the push-push mechanism design. In this paper, a flexible multibody model of a push-push mechanism was developed to analyze dynamic stress at a cam slider and a cam stick.

THE EFFECT OF RESIDUAL PERIODONTAL LIGAMENT ON ALVEOLAR BONE REMODELING OF EXTRACTION SOCKETS IN RATS (백서 치아 발거후 잔존 치주인대가 발치와의 치조골 재건에 미치는 영향)

  • Cho, Seong-Hoon;Herr, Yeek;Park, Joon-Bong;Lee, Man-Sup;Kwon, Young-Hyuk
    • Journal of Periodontal and Implant Science
    • /
    • v.25 no.3
    • /
    • pp.703-719
    • /
    • 1995
  • The purpose of this study was to observe the effects of the periodontal ligament on the healing and the formation of alveolar bone in the extraction socket, when this ligament had artificially remained in the socket during the tooth removal. Twenty rats aged 4 weeks were used and devided into the control groups (10) and the experimental groups (10) in this study. The maxillary right and left first molars were extracted in both groups. In the experimental groups the periodontal ligament was remained in the extraction sockets using 0.4% ${\beta}-aminopropionitrile$, and in the control the periodontal ligament was completely removed by curettage. At 1, 3, 5, 7 and 14 days after the tooth extraction, rats in both groups were serially sacrificed. And the specimens were prepared with Hematoxylin-Eosin stain for the light microscopic evaluation. The results of this study were as follows ; 1. On 1 day, the periodontal ligament was only found in the extraction socket walls of the experimental groups, and there was not the distinguishable difference between the control and the experimental groups. 2. On 3 days, there were more collagen fibers and the appearance of higher cellular density in the experimental groups than in the control. And the cells and collagen of the periodontal ligament were so actively proliferated and synthesized that invaded into the connective tissue of the extraction sockets in the experimental groups. 3. In the experimental groups, the trabecular bone was formed on the basal and lateral bone surface on 5 days. However, there was not the new bone forming appearance in the control groups at this time. 4. On 7 days, the trabecular bone was formed in the control groups. 5. On 14 days, the extraction sockets were almost entirely filled with the bony trabeculae in both groups. But, compared to the control group, the experimental groups showed the prominent differences in the amount & the density of the new bone formed. In conclusion, it was suggested that the residual periodontal ligament tissue in the extraction socket will play a major role as the important cell source in the healing and the new bone formation of the extraction socket.

  • PDF

EFFECT OF ELECTRICAL STIMULATION ON BONE FORMATION IN THE EXTRACTION SOCKET OF RAT (전기자극이 치조골 치유과정에 미치는 영향)

  • Yang, Seung-Han;Lee, Man-sup;Park, Joon-bong;Herr, Yeek
    • Journal of Periodontal and Implant Science
    • /
    • v.31 no.4
    • /
    • pp.669-687
    • /
    • 2001
  • On the basis of the evidence that electrical stimulation could promote healing and regeneration of bone, this study was performed to investigate the effects of electrical stimulation on rat extraction socket, and to evaluate the potential of clinical application of electrical stimulation. Forty rats were used and divided into control groups(l0)and the experimental groups(30) in this study. The maxillary 1st molar were extracted in both groups. In experimental group, electrical stimulation was given at the current intensity of lmA(Test-1), l0mA(Test-2), 25mA(Test-3) each day. At 1,3,5,7 days after the tooth extraction, rats in both groups were serially sacrificed. And the specimens were prepared with Hematoxylin-Eosin stain for the light microscopic evaluation. The results of this study were as follows; 1. At 1 day after the extraction, the periodontal ligament was found in the extraction socket wall. The formation of blood clot with dense infiltration of inflammatory cells in control group and there were less inflammatory cells in test group. 2. At 3 day after the extraction, the cells and collagen of the periodontal ligament were so actively proliferated and synthesized that invaded into the connective tissue of the extraction sockets in the control group. There were the formation of new bone in the basal & lateral portion of socket wall in test -2 and -3. 3. At 5 days after the extraction, there were no formation of new bone in control group. But the more electrical stimulation was applied, the more formation of new bone in test group. 4. At 7 days after the extraction, the extraction sockets were almost filled with trabecular bone in each group. Bone maturarity was remarkable in test-3. 5. The electrical stimulation at l0mA and 25mA was more effective in the bone formation at 5 and 7 days after the extraction. From the above results, electrical stimulation could promote the extraction socket wound healing, and be utilized in the clinical application of the residual ridge expansion.

  • PDF

Socket preservation using deproteinized horse-derived bone mineral

  • Park, Jang-Yeol;Koo, Ki-Tae;Kim, Tae-Il;Seol, Yang-Jo;Lee, Yong-Moo;Ku, Young;Rhyu, In-Chul;Chung, Chong-Pyoung
    • Journal of Periodontal and Implant Science
    • /
    • v.40 no.5
    • /
    • pp.227-231
    • /
    • 2010
  • Purpose: The healing process following tooth extraction apparently results in a pronounced resorption of the alveolar ridge. As a result, the width of alveolar ridge is reduced and severe alveolar bone resorption occurs. The purpose of this experiment is to clinically and histologically evaluate the results of using horse-derived bone mineral for socket preservation. Methods: The study comprised 4 patients who were scheduled for extraction as a consequence of severe chronic periodontitis or apical lesion. The extraction was followed by socket preservation using horse-derived bone minerals. Clinical parameters included buccal-palatal width, mid-buccal crest height, and mid-palatal crest height. A histologic examination was conducted. Results: The surgical sites healed uneventfully. The mean ridge width was $7.75{\pm}2.75\;mm$ at baseline and $7.00{\pm}2.45\;mm$ at 6 months. The ridge width exhibited no significant difference between baseline and 6 months. The mean buccal crest height at baseline was $7.5{\pm}5.20\;mm$, and at 6 months, $3.50{\pm}0.58\;mm$. The mean palatal crest height at baseline was $7.75{\pm}3.10\;mm$, and at 6 months, $5.00{\pm}0.82\;mm$. There were no significant differences between baseline and 6 months regarding buccal and palatal crest heights. The amount of newly formed bone was $9.88{\pm}2.90%$, the amount of graft particles was $42.62{\pm}6.57%$, and the amount of soft tissue was $47.50{\pm}9.28%$. Conclusions: Socket preservation using horse-derived bone mineral can effectively maintain ridge dimensions following tooth extraction and can promote new bone formation through osteoconductive activities.

Structural Stability Analysis of One-Touch Insertion Type Pipe Joint for Refrigerant (냉매용 원터치 삽입식 파이프 조인트의 안전성 구조해석)

  • Kim, Eun-young;Park, Dong-sam
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.3
    • /
    • pp.542-549
    • /
    • 2022
  • Purpose: Pipes are widely used as applied devices in many industrial fields such as machinery, electronics, electricity, and plants, and are also widely used in safety-related fields such as firefighting and chemistry. With the diversification of products, the importance of technology in the piping field is also increasing. In particular, when changing the existing copper pipe to stainless steel, it is necessary to evaluate safety and flow characteristics through structural analysis or flow analysis. Method: This study investigated the structural stability of the 6.35 and 15.88 socket models, which are integrated insert type connectors developed by a company, using FEM. For structural analysis, HyperMesh as pre-processor, HYPER VIEW as post-processor, and LS-DYNA as solver were used. Result: In the case of 6.35 socket, the maximum stresses at hook, holder and hinge were 95.02MPa, 19.59MPa and 44.01MPa, respectively, and in case of 15.88 socket, it was 127.7 MPa, 40.09MPa and 45.23MPa, respectively. Conclusion: Comparing the stress distribution of the two socket models, the stress in the 15.88 socket, which has a relatively large outer diameter, appears to be large overall, but it is significantly lower than the yield stress of each material, indicating that there is no problem in structural safety in both models.

Evaluation of Shear Performance for CSB (Confined Socket Bolt) Shear Connector (CSB (Confined Socket Bolt) 전단연결재의 전단 성능 평가 )

  • Seung-Hyeon Hwang;Ju-Hyun Mun;Jong-Kook Hong;Jong-Cheol Jeon;Jae-Il Sim
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.2
    • /
    • pp.8-16
    • /
    • 2023
  • This study evaluated a shear capacity of confined socket-bolt (CSB) shear connector developed for utilizing cast in placed pile (CIP) as a permanent underground wall. The push-out tests were performed in the specimens with different CIP types, CSB shear connector types, L/d, and concrete compressive strengths of concrete pile, and with or without waterproofing at interfaces between CIP and underground wall. Test results showed that the specimens with a H-shaped pile were fractured in the CSB shear connector, while the fracture concentrated in the concrete part of the specimens with a reinforced concrete pile was alleviated as the compressive strength of the concrete pile increased, resulting in the severe fracture of CSB shear connector. The maximum shear capacities of the specimens with high strength bolts and reinforcing bars used as CSB shear connector were approximately 1.22 and 1.20 times higher than those of the specimens with a H-shaped pile, respectively, and 1.10 and 1.16 times higher than those of the specimens with a reinforced concrete pile, respectively. Meanwhile, the maximum shear capacity was not significantly affected by the embedding length of the CSB shear connector and overlapping length of reinforcing bar. The predicted shear capacities calculated from the KDS standards were lower than the measured values of all specimens tested in this study.