• Title/Summary/Keyword: SNR offset

Search Result 66, Processing Time 0.018 seconds

Improved Timing Synchronization Using Phase Difference between Subcarriers in OFDMA Uplink Systems (OFDMA 상향 링크 시스템에서 부반송파간 위상 회전 정보를 이용한 개선된 시간 동기 추정 알고리즘)

  • Lee, Sung-Eun;Hong, Dae-Sik
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.46 no.2
    • /
    • pp.46-52
    • /
    • 2009
  • In this paper, the timing estimator based on the principle of the best linear unbiased estimator (BLUE) is proposed in OFDMA uplink systems. The proposed timing estimator exploits the phase information of the differential correlation between adjacent subcarriers. The differential correlation can extract the information about timing offset and mitigate the distortion of the signal caused by the frequency selectivity of channel. Compared with conventional methods, the proposed estimator shows more accurate capability in estimation. In addition, the estimator is hardly affected by the distortion caused by the frequency selectivity of channel. Simulation results confirm that the proposed estimator shows a small error mean and a relatively small error variance. In addition, the performance of the estimator is evaluated by means of SNR loss. It is shown by simulations that the SNR loss of the proposed estimator by estimation errors is less than 0.4 dB for the SNR values between 0 and 20 dB. This might indicate that the proposed estimator is suitable for the timing synchronization of multiple users in OFDMA uplink systems.

Speech Enhancement Based on Improved Minima Controlled Recursive Averaging Incorporating GSAP (전역 음성 부재 확률 기반의 향상된 최소값 제어 재귀평균기법을 이용한 음성 향상 기법)

  • Song, Ji-Hyun;Bang, Dong-Hyeouck;Lee, Sang-Min
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.49 no.1
    • /
    • pp.104-111
    • /
    • 2012
  • In this paper, we propose a novel method to improve the performance of the improved minima controlled recursive averaging (IMCRA). From an examination for various noise environment, it is shown that the IMCRA has a fundamental drawback for the noise power estimate at the offset region of continuity speech signals. Espectially, it is difficult to obtain the robust estimates of the noise power in non-stationary noisy environments that is rapidly changed the spectral characteristics such as babble noise. To overcome the drawback, we apply the global speech absence probability (GSAP) conditioned on both a priori SNR and a posteriori SNR to the speech detection algorithm of IMCRA. With the performance criteria of the ITU-T P.862 perceptual evaluation of speech quality (PESQ) and a composite measure test, we show that the proposed algorithm yields better results compared to the conventional IMCRA-based scheme under various noise environments. In particular, in the case of babble 5 dB, the proposed method produced a remarkable improvement compared to the IMCRA ( PESQ = 0.026, composite measure = 0.029 ).

An Efficient Receiver Structure Based on PN Performance in Underwater Acoustic Communications (수중음향통신에서 PN 성능 기반의 효율적인 수신 구조)

  • Baek, Chang-Uk;Jung, Ji-Won
    • Journal of Navigation and Port Research
    • /
    • v.41 no.4
    • /
    • pp.173-180
    • /
    • 2017
  • Underwater communications are degraded as a result of inter symbol interference in multipath channels. Therefore, a channel coding scheme is essential for underwater communications. Packets consist of a PN sequence and a data field, and the uncoded PN sequence is used to estimate the frequency and phase offset using a Doppler and phase estimation algorithm. The estimated frequency and phase offset are fed to a coded data field to compensate for the Doppler and phase offset. The PN sequence is generally utilized to acquire the synchronization information, and the bit error rate of an uncoded PN sequence predicts the performance of the coded data field. To ensure few errors, we resort to powerful BCJR decoding algorithms of convolutional codes with rates of 1/2, 2/3, and 3/4. We use this powerful channel coding algorithm to present an efficient receiver structure based on the relation between the bit error of the uncoded PN sequence and coded data field in computer simulations and lake experiments.

Design of Digital PLL with Asymmetry Compensator in High Speed DVD Systems (고속 DVD 시스템에서 비대칭 신호 보정기와 결합한 Digital PLL 설계)

  • 김판수;고석준;최형진;이정현
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.26 no.12A
    • /
    • pp.2000-2011
    • /
    • 2001
  • In this Paper, we convert conventional low speed(1x, 6x) DVD systems designed by analog PLL(Phase Locked Loop) into digital PLL to operate at high speed systems flexibly, and present optimal DPLL model in high speed(20x) DVD systems. Especially, we focused on the design of DPLL that can overcome channel effects such as bulk delay, sampling clock frequency offset and asymmetry phenomenon in high speed DVD systems. First, the modified Early-Late timing error detector as digital timing recovery scheme is proposed. And the four-sampled compensation algorithm using zero crossing point as asymmetry compensator is designed to achieve high speed operation and strong reliability. We show that the proposed timing recovery algorithm provides enhanced performances in jitter valiance and SNR margin by 4 times and 3dB respectively. Also, the new four-sampled zero crossing asymmetry compensation algorithm provides 34% improvement of jitter performance, 50% reduction of compensation time and 2.0dB gain of SNR compared with other algorithms. Finally, the proposed systems combined with asymmetry compensator and DPLL are shown to provide improved performance of about 0.4dB, 2dB over the existing schemes by BER evaluation.

  • PDF

Performance of Magnitude Sum Correlation and Vector Sum Correlation Methods for Robust Frame Synchronization Under Low Signal-to-Noise Ratios (낮은 신호 대 잡음 비에서 강건한 프레임 동기를 위한 크기 합 상관 및 벡터 합 상관 방식의 성능 평가)

  • Lee, Dong-Uk;Kim, Sang-Tae;Sung, Won-Jin
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.45 no.7
    • /
    • pp.32-37
    • /
    • 2008
  • Satellite communication systems including the DVB-S2 (Digital Video Broadcasting - Satellite Version 2) system require operations under low signal-to-noise ratio (SNR) and large frequency offset values, and the initial frame synchronization process necessitates a robust correlation method. While a variety of conventional correlation structures exist for the initial synchronization, each method has different characteristics and performance in different channel environments. In this paper, we propose new correlation methods which exhibit enhanced performance in low SNR and large frequency offsets, and analyze their performance. The proposed methods use the magnitude sum and vector sum of extended differential correlation values, to maximize the correlation between the received signal and the synchronization sequence by using the spanned differential correlation result. The magnitude sum correlation method has better performance compared to conventional methods including the approximated ML (Maximum likelihood) method for SNR values below 4 dB with or without frequency offsets. The vector sum correlation method has improved performance over the magnitude sum method for channels with relatively small frequency offsets.

Single Antenna Radar Sensor with FMCW Radar Transceiver IC (FMCW 송수신 칩을 이용한 단일 안테나 레이다 센서)

  • Yoo, Kyung Ha;Yoo, Jun Young;Park, Myung Chul;Eo, Yun Seong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.8
    • /
    • pp.632-639
    • /
    • 2018
  • This paper presents a single antenna radar sensor with a Ku-band radar transceiver IC realized by 130 nm CMOS processes. In this radar receiver, sensitivity time control using a DC offset cancellation feedback loop is employed to achieve a constant SNR, irrespective of distance. In addition, the receiver RF block has gain control to adjust high dynamic range. The RF output power is 9 dBm and the full chain gain of the Rx is 82 dB. To reduce the direct-coupled Tx signal to the Rx in a single antenna radar, a stub-tuned hybrid coupler is adopted instead of a bulky circulator. The maximum measured distance between the horn antenna and a metal plate target is 6 m.

Acquisition Performance of Tiered Polyphase Code Based GNSS Signal (계층 다상 부호 기반 위성항법 시스템의 신호획득 성능 연구)

  • Kim, Jeong-Been;Ahn, Jae Min
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38A no.11
    • /
    • pp.970-972
    • /
    • 2013
  • Signal acquisition performance is evaluated for the tiered polyphase code (TPC) which is proposed as a ranging signal structure for global navigation satellite systems (GNSSs). Compared to the tiered code (TC) which is adopted in European Union's GALILEO system, the TPC shows robust performance to frequency offset in acquiring signal. Therefore the TPC should have SNR gain in signal acquisition and can reduce computational complexity in the receiver. In this paper, we compare the signal detection probability of the TC and TPC under the same receiver architecture and GALILEO E5a-I signal parameters.

A Low Noise Low Power Capacitive Instrument Amplifier for Bio-Potential Detection (생체 신호 측정용 저 잡음 저 전력 용량성 계측 증폭기)

  • Park, Chang-Bum;Jung, Jun-Mo;Lim, Shin-Il
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.5
    • /
    • pp.342-347
    • /
    • 2017
  • We present a precision instrument amplifier (IA) designed for bio-potential acquisition. The proposed IA employs a capacitively coupled instrument amplifier (CCIA) structure to achieve a rail-to-rail input common-mode range and low gain error. A positive feedback loop is applied to boost the input impedance. Also, DC servo loop (DSL) with pseudo resistors is adopted to suppress electrode offset for bio-potential sensing. The proposed amplifier was designed in a $0.18{\mu}m$ CMOS technology with 1.8V supply voltage. Simulation results show the integrated noise of $1.276{\mu}Vrms$ in a frequency range from 0.01 Hz to 1 KHz, 65dB SNR, 118dB CMRR, and $58M{\Omega}$ input impedance respectively. The total current of IA is $38{\mu}A$. It occupies $740{\mu}m$ by $1300{\mu}m$ including the passive on-chip low pass filter.

Analysis of $^1H$ MR Spectroscopy of parietal white matter material Phantom (두정부 백질 물질을 이용한 수소 자기 공명 분광 분석)

  • Lee, Jae-Yeong;Lim, Cheong-Hwan;Kim, Myeong-Soo
    • Journal of radiological science and technology
    • /
    • v.26 no.2
    • /
    • pp.57-61
    • /
    • 2003
  • The purpose of this study is to compare both 1.5T and 4.7T in Praietal White matter material Phantom using the same methodology at both field strengths. Data at both field strengths are compared in terms of $T_2$ relaxation times, line widths and SNRs MR imaging and $^1H$ MR spectroscopy were performed on GE 1.5T SIGNA system and Broker Biospec 4.7T/30 MRI/MRS system. After phantom axial scan $^1H$ MRS was obtained from T2 weighted image by 3-dimensional localization technique(PRESS : Point RE solved spectroscopy Sequence) this phantom is composed of an aqueous solution 36.7 mmol/L of NAA, 25.0 mmol/L of Cr, 6.3 mmol/L of choline chloride, 30.0 mmol/L or Glu, and 22.5 mmol/L of MI(adjusted to a pH of 7,15 in a phosphate buffet). Data processed using software developed inhouse. At 1.5T, T2 relaxation times for Cho, Cr, and NAA were $0.41{\pm}0.07,\;0.26{\pm}0.04,\;0.46{\pm}0.07$ while at 4.7T they were $0.17{\pm}0.03,\;0.14{\pm}0.05,\;0.20{\pm}0.03$ respectively. At 1.5T, line widths for water, Cho, Cr and NAA were $2.9{\pm}0.7,\;1.6{\pm}0.7,\;1.7{\pm}0.8,\;2.2{\pm}0.02Hz$ while at 4.7T they were $5.2{\pm}1.1,\;4.6{\pm}1.9,\;4.01{\pm}1.8,\;4.8{\pm}1.9Hz$ respectively. It can be seen that $T_2$ relaxation times were significantly shorter at 4.7 compared to 1.5T and that the line widths were also broader. The average SNRs for NAA for subjects at short and long TEs were $23.5{\pm}11.3$ at TE=20 msec ; $15.4{\pm}7.7$ at TE=272 msec at 1.5T and $40{\pm}8.3$ and $17{\pm}3.5$ respectively at 4.7T higher field strength is superior because of improved sensitivity and chemical shift dispersion. However these improvements are partially offset by increased line widths and decrease $T_2$ relaxation times, which act to reduce both sensitivity and resolution. In our experiments with the equipment available to us, 4.7T proton spectra at short TEs exhibit moderately improved sensitivity compared to 1.5T.

  • PDF

Doppler Radar System for Long Range Detection of Respiration and Heart Rate (원거리에서 측정 가능한 호흡 및 심박 수 측정을 위한 도플러 레이더 시스템)

  • Lee, Jee-Hoon;Kim, Ki-Beom;Park, Seong-Ook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.4
    • /
    • pp.418-425
    • /
    • 2014
  • This paper presents a Ku-Band Doppler Radar System to measure respiration and heart rate. It was measured by using simultaneous radar and ECG(Electrocardiogram). Arctangent demodulation without dc offset compensation can be applied to transmitted I/Q(In-phase & Quadrature-phase) signal in order to improve the RMSE(Root Mean Square Error) about 50 %. The power leaked to receiving antenna from the transmitting antenna is always generated because of continuously opening the transceiver of CW(Continuous Wave) Doppler radar. As the output power increase, leakage power has an effect on the SNR(Signal-to-Noise Ratio) of the system. Therefore, in this paper, leakage cancellation technique that adds the signal having the opposite phase of the leakage power to the leakage power was implemented in order to minimize the decline of receiver sensitivity. By applying the leakage cancellation techniques described above, it is possible to measure the heart rate and respiration of the human at a distance of up to 35 m. the heart rate of the measured data at a distance of 35 m accords with the heart rate extracted from the ECG data.