• Title/Summary/Keyword: SNAP

Search Result 409, Processing Time 0.042 seconds

Nitric oxide(NO) mediating non-adrenergic non-cholinergic(NANC) relaxation in the boar retractor penis muscle II. Comparison of the relaxant properties induced by nonadrenergic, noncholinergic nerve stimulation and S-nitrosothiols in the porcine retractor penis muscle (Nitric oxide에 의한 수퇘지 음경후인근의 비아드레날린 비콜린 동작성 이완 II. 비아드레날린 비콜린성 신경의 전장자극과 S-nitrosothiols에 의한 돼지 음경후인근의 이완 효과 비교)

  • Mun, Kyu-whan;Kim, Tae-wan;Kang, Tong-mook;Lee, Wan;Yang, Il-suk
    • Korean Journal of Veterinary Research
    • /
    • v.35 no.3
    • /
    • pp.459-469
    • /
    • 1995
  • As S-nitrosothiols were proposed as nitrergic carriers in vascular and nonvascular smooth muscle, we have investigated the relaxant properties of several S-nitrosothiols in the porcine retractor penis(PRP) muscle and compared them with the effects of exogenously added NO, electrical field stimulation(EFS) of NANC nerves and sodium nitroprusside(SNP). Also the influences of oxyhemoglobin and hydroquinone on the relaxant responses were investigated. In addition, effects of NO on membrane potentials and its involvement in the generation of inhibitory junction potential(IJP) were investigated with conventional intracellular microelectrode technique. The results were summerized as follows. 1. Frequency-dependent relaxations of PRP muscle were induced by EFS to NANC nerve. Tetrodotoxin($1{\times}10^{-6}M$) abolished the relaxations of PRP muscle induced by EFS, and L-NAME(($2{\times}10^{-5}M$) and methylene blue($4{\times}10^{-5}M$) inhibited the relaxations. L-NAME-induced inhibition of the relaxations was reversed by L-arginine($1{\times}10^{-3}M$), but not by D-arginine. 2. Exogenous NO($1{\times}10^{-5}-1{\times}10^{-4}M$), sodium nitroprusside(($1{\times}10^{-7}-1{\times}10^{-4}M$) induced dose-dependent relaxations of PRP muscle. All S-nitrosothiols($1{\times}10^{-7}-1{\times}10^{-4}M$) tested relaxed the PRP muscle in dose-dependent manner and the potency order was SNAP>GSNO>CysNO>SNAC. 3. Oxyhemoglobin($5{\times}10^{-5}M$) blocked the relaxation induced by exogenous NO and inhibited EFS-, S-nitrosothiols-, and SNP-induced relaxation. 4. Hydroquinone($1{\times}10^{-4}M$) also abolished the relaxations induced by exogenous NO, and reduced the relaxations induced by S-nitrosothiols, but did not affect EFS- and SNP-induced relaxations. 5. SNP($2{\times}10^{-6}-5{\times}10^{-6}M$) relaxed muscle strips but the membrane potentials were not affected. 6. EFS with several pulses(1ms, 2Hz, 80V) produced an inhibitory junction potential(IJP) with muscle relaxation. They were abolished by TTX($2{\times}10^{-6}M$). $N^G$-nitro-$_{\small{L}}$-arginine(L-NNA, $2{\times}10^{-5}M$) abolished the muscle relaxation, but had no effect on IJP.

  • PDF

A New Pod Edible Kidney Bean Variety "Hwanghyeob 2" with Yellow Pod Color (협채용 강낭콩 신품종 "황협2호")

  • Shin, Doo-Chull;Kang, Sung-Taek;Han, Won-Young;Baek, In-Youl;Choung, Myoung-Gun;Park, Keum-Yong;Ha, Tae-Jung;Hwang, Young-Hyun;Ko, Jong-Min;Suh, Duck-Yong;Kim, Ho-Yeong
    • Korean Journal of Breeding Science
    • /
    • v.40 no.4
    • /
    • pp.470-473
    • /
    • 2008
  • A new kidney bean cultivar, "Hwanghyeob 2" was developed for edible pod kidney bean adaptable to Korean cultivation at the National Institute of Crop Science in 2005. "Hwanghyeob 2" was selected from a cross between KLG50073 and KLG50072. It has determinate growth habit, white flower, yellow pod color, oval shape of crossed section of pod at the harvesting time for edible pod. It has white seed coat and middle seed size (20.4 grams per 100 seeds). The average yield of edible pod of "Hwanghyeob 2" was 22.43 M/T per hectare in the yield trials which was carried out at the green house in spring and autumn in 2005. This yield level was 11 percent higher than that of the check cultivar "Kangnangkong 1".

Effect of FS11052, an Inhibitor of Exocytosis, on Neurite Extension in Rat Hippocampal Neurons and PC12 Cells (신경전달물질 방출 저해제 FS11052가 신경세포와 PC12 세포의 돌기신장에 미치는 영향)

  • Lee Yun-Sik;Kim Dong-Seob
    • Journal of Life Science
    • /
    • v.16 no.2 s.75
    • /
    • pp.315-322
    • /
    • 2006
  • FS11052, a novel microbial metabolite from Streptomyces spp. was identified as a small molecular substance and shown inhibition activities for the release of neurotransmitter from rat hippocampal neuron and PC12 cells. FS11052 is an inhibitor of tritiated norepinephrine ($[^3H]-NE$) release in high $K^+$ buffer solution containing ionomycin, indicating that FS11052 inhibits neurotransmitter release after the influx of $Ca^{2+}$ ions. When examined the effect of FS11052 on glucuronidase release from guinea pig neutrophils, FS11052 inhibited glucuronidase release: when treated with $5{\mu}g/ml$ of FS11052, which was not induced cellular cytotoxicity. The fact that the glucuronidase release in neutrophil and norepinephrine release in neuron was inhibited suggests the similarity in the locations and the mechanisms of FS11052 action targets. When treated with $5{\mu}g/ml$ of FS11052, $[^3H]-NE$ release and neurite extension for both rat hippocampal neurons and PC12 cells were prevented. These observations of FS11052 functioning as an inhibitor of neurotransmitter release suggest that FS11052 has an important role in synaptic transmission in neuron.

The Kinematics Analysis of the Badminton High Clear Motion in Woman Middle School Student (여자중학생 배드민턴 하이클리어 동작의 운동학적 분석)

  • Kim, Chang-Bum;Ryu, Jae-Kwang
    • Korean Journal of Applied Biomechanics
    • /
    • v.12 no.2
    • /
    • pp.91-107
    • /
    • 2002
  • This research got the following conclusion as result that analyzed high clear action kinematically to 4 C girls' junior high school badminton players who are situated in Chungchong-bukdo. 1. Most of the subject didn't rotate their right shoulder and elbow joint at back swing and moved speedy to shuttle cock. And an cooperation action of joint decreases displaying only a good action on both subject`s specification joint part. 2. When the subject S1 and S2 swing slowly and largely the joint of shoulder and elbow and then the speed of right wrist and racket head is fast, the cooperation action of joint is better than other subject. 3. An angle change of right shoulder showed angle that all subjects are great being caused in softness of joint and angular velocity was exposed that load enough Impact force and increase the speed of racket head as angular velocity decreases rapidly in Impact except subject S3. 4. All subjects of right elbow angle change showed similar form and was exposed that subject S2 sees form of impact stage serious bends from back swing and do not use force effectively in angular velocity. 5. Angle of right wrist appeared that the speed of shuttle cock is decelerated because fast bends of wrist is not formed shortly after Impact because all subject do not accomplish big angle shortly after back swing. Angular velocity can assume that the subject S1 and S4 are using and move fast strong snap shot offering angular velocity value of Impact stage sound (-). 6. While size of Impact stage knee angle accomplishes angle that is big both subject, hip joint angles sees small angle and is playing swing that do on upper body and arm without using strong waist force that is composition action with knee and hip joint.

Analysis of prognostic factors of laparotomy for necrotizing enterocolitis in extremely low birth weight infants (괴사성 장염으로 수술한 초극소저체중출생아(<1,000 g)의 예후인자 분석)

  • Kim, Jin Kyu;Kim, Yi Sun;Yoo, Hye Soo;Ahn, So Yoon;Seo, Hyun Ju;Choi, Seo Heui;Park, Soo Kyung;Jung, Yu Jin;Kim, Myo Jing;Jeon, Ga Won;Koo, Soo Hyun;Lee, Kyung-Hoon;Chang, Yun Sil;Park, Won Soon
    • Clinical and Experimental Pediatrics
    • /
    • v.53 no.2
    • /
    • pp.167-172
    • /
    • 2010
  • Purpose : With improved survival of extremely low birth weight infants (ELBWI), there is an increase in the incidence of necrotizing enterocolitis (NEC) requiring laparotomy, and the risk of morbidity and mortality in these ELBWI is increased. Thus, we determined the prognostic factors in ELBWI who underwent laparotomy for NEC. Methods : We retrospectively reviewed the medical records of 35 ELBWI who underwent laparotomy for NEC from January 2001 to December 2008 at Samsung Medical Center. Results : Of 480 ELBWI, 35 required laparotomy for NEC; the mortality rate was 20% (Alive group n=28, Dead group n=7). The values of preoperative score for neonatal acute physiology-II (P =0.022) and fraction of inspired oxygen (P <0.001) were significantly higher in the dead group and values of base excess (P =0.004) were significantly lower in the dead group. Values of preoperative heart rate, respiration rate, mean blood pressure, pH, $CO_2$, and potassium ion were not significantly different between the study groups. Intraoperative fluid volume was significantly higher in the alive group than in the dead group (P =0.045). Postoperative infusion rate was significantly lower in the alive group than in the dead group (P =0.022). Conclusion : Good preoperative condition, more intraoperative fluid infusion, and stable postoperative hemodynamic condition were factors associated with favorable prognosis of laparotomy for NEC in ELBWI.

Effect of Moutan Cortex Radicis on gene expression profile of differentiated PC12 rat cells oxidative-stressed with hydrogen peroxide (모단피의 PC12 cell 산화억제 효과 및 neuronal 유전자 발현 profile 분석에 대한 연구)

  • Kim Hyun Hee;Rho Sam Woong;Na Youn Gin;Bae Hyun Su;Shin Min Kyu;Kim Chung Suk;Hong Moo Chang
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.17 no.2
    • /
    • pp.529-541
    • /
    • 2003
  • Yukmijihwang-tang has been widely used as an and-aging herbal medicine for hundred years in Asian countries. Numerous studies show that Yukmijihwangtang has anti-oxidative effect both in vivo and in vitro. It has been reported that Moutan Cortex Radicis extract (MCR) was the most effective herb in Yukmijihwang-tang on undifferentiated PC12 cells upon oxidative-stressed with hydrogen peroxide. The purpose of this study is to; 1) evaluate the recovery of neuronal damage by assessing the anti-oxidant effect of MCR on PC12 cells differentiated with nerve growth factor (NGF), 2) identify candidate genes responsible for anti-oxidative effect on differentiated PC12 cells by oligonucleotide chip microarray. PC12 cells, which were differentiated by treating with NGF, were treated without or with hydrogen peroxide in the presence or absence of various concentration of MCR. Cell survival was determined by using MTS assay. Measurement of intracellular reactive oxygen species (ROS) generation was determined using the H2DCFDA assay The viability of cells treated with MCR was significantly recovered from stressed PC12 cell. In addition, wide rage of concentrations of MCR shows dose-dependent inhibitory effect on ROS production in oxidative-stressed cells. Total RNAs of cells without treatment(Control group), only treated with H₂O₂ (stressed group) and treated with both H₂O₂ and of MCR (MCR group) were isolated, and cDNAs was synthesized using oligoT7(dT) primer. The fragmented cRNAs, synthesized from cDNAs, were applied to Affymetrix GeneChip Rat Neurobiology U34 Array. mRNA of Calcium/calmodulin-dependent protein kinase II delta subunit(CaMKII), neuron glucose transporter (GLUT3) and myelin/oligodendrocyte glycoprotein(MOG) were downregulated in Stressed group comparing to Control group. P2X2-5 receptor (P2X2R-5), P2X2-4 receptor (P2X2R-4), c-fos, 25 kDa synaptosomal attachment protein(SNAP-25a) and GLUT3 were downregulated, whereas A2 adenosine receptor (A2AR), cathechol-O-methyltransferase(COMT), glucose transporter 1 (GLUT1), EST223333, heme oxygenase (HO), VGF, UI-R-CO-ja-a-07-0-Ul.s1 and macrophage migration inhibitory factor (MIF) were upregulated in MCA group comparing to Control group. Expression of Putative potassium channel subunit protein (ACK4), P2X2A-5, P2X2A-4, Interferon-gamma inducing factor isoform alpha precursor (IL-18α), EST199031, P2XR, P2X2 purinoceptor isoform e (P2X2R-e), Precursor interleukin 18 (IL-18) were downregulated, whereas MOO, EST223333, GLUT-1, MIF, Neuronatin alpha, UI-R-C0-ja-a-07-0-Ul.s1, A2. adenosine receptor, COMT, neuron-specific enolase (NSE), HO, VGF, A rat novel protein which is expressed with nerve injury (E12625) were upregulated in MCR group comparing to Stressed group. The results suggest that decreased viability and AOS production of PC12 cell by H₂O₂ may be, at lease, mediated by impaired glucose transporter expression. It is implicated that the MCR treatment protect PC12 cell from oxidative stress via following mechanisms; improving glucose transport into the cell, enhancing expression of anti-oxidative genes and protecting from dopamine cytotoxicity by increment of COMT and MIF expression. The list of differentially expressed genes may implicate further insight on the action and mechanism behind the anti-oxidative effects of herbal extract Moutan Cortex Radicis.

Doses of Coronary Study in 64 Channel Multi-Detector Computed Tomography : Reduced Radiation Dose According to Varity of Examnination Protocols (64 채널 Multi-Detector Computed Tomography를 이용한 관상동맥검사의 선량 : 검사 프로토콜 다변화에 따른 환자선량 감소)

  • Kim, Moon-Chan
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.299-306
    • /
    • 2009
  • Purpose : To compare radiation dose for coronary CT angiography (CTA) obtained with 6 examination protocols such as a retrospectively ECG gated helical scan, a prospectively ECG gated sequential scan, low kVp technique, and cardiac dose modulation technique. Materials and Methods : Coronary CTA was performed by using 6 current clinical protocols to evaluate effective dose and organ dose in primary beam area with anthropomorphic female phantom and glass dosimetric system in 64 channel multi-detector CT. After acquiring topograms of frontal and lateral projection with 80 kVp and 10 mA, main coronary scan was done with 0.35 sec tube rotation time, 40 mm collimation ($0.625\;mm{\times}64\;ea$), small scan field of view (32 cm diameter), 105 mm scan length. Heart beat rate of phantom was maintained 60 bpm in ECG gating. In constant mAs technique 120 kVp, 600 mA was used, and 100 kVp for low kVp technique. In a retrospectively ECG gated helical CT technique 0.22 pitch was used, peak mA (600 mA) was adopted in range of $40{\sim}80%$ of R-R interval and 120mA(80% reduction) in others with cardiac dose modulation. And 210 mAs was used without cardiac dose modulation. In a prospectively ECG gated sequential CT technique data were acquired at 75% R-R interval (middle diastolic phase in cardiac cycle), and 120 msec additional padding of the tube-on time was used. For effective dose calculation region specific conversion factor of dose length product in thorax was used, which was recommended by EUR 16262. Results : The mean effective dose for conventional coronary CTA without cardiac dose modulation in a retrospectively ECG gated helical scan was 17.8 mSv, and mean organ dose of heart was 103.8 mGy. With low kVp and cardiac dose modulation the mean effective dose showed 54.5% reduction, and heart dose showed 52.3% reduction, compared with that of conventional coronary CTA. And at the sequential scan(SnapShot pulse mode) under prospective ECG gating the mean effective dose was 4.9 mSv, this represents an 72.5% reduction compared with that of conventional coronary CTA. And heart dose was 33.8 mGy, this represents 67.4% reduction. In the sequential scan technique under prospective ECG gating with low kVp the mean effective dose was 3.0 mSv, this represents an 83.2% reduction compared with that of conventional coronary CTA. And heart dose was 17.7 mGy, this represents an 82.9% reduction. Conclusion : In coronary CTA at retrospectively ECG gated helical scan, cardiac dose modulation technique using low kVp reduced dose to 50% above compared with the conventional helical scan. And the prospectively ECG gated sequential scan offers substantially reduced dose compared with the traditional retrospectively ECG gated helical scan.

  • PDF

Color Stability of Self-Cured Temporary Crown Resin according to Different Surface Treatments (자가중합 임시치관용 레진의 표면 처리에 따른 색 안정성)

  • Park, Ji-Won;Bae, Sung-Suk
    • Journal of dental hygiene science
    • /
    • v.16 no.2
    • /
    • pp.150-156
    • /
    • 2016
  • In this study, the surface treatment of a self-cured temporary crown was polished using a denture bur, silicone bur, or pumice. The color stability of the temporary crown resin specimen was evaluated by immersing it in coffee, and cola, wine, beer, red pepper paste, or soybean paste. Two-hundred eighty-five identical resin specimens with six types of staining solution and three types of surface treatment were placed in a shaking incubator at $37^{\circ}C$. The degree of discoloration was observed using a time-lapse recording of days 1, 5, and 7. $L^*$, $a^*$, and $b^*$ were measured using a spectrophotometer, which shows the quantitative value of discoloration, and statistically processed after calculating ${\Delta}E^*$. The results show that as time passed, all the specimens showed a color change (p<0.001). The amount of color change was the greatest in in crowns with denture bur polishing on the day 1, 5, and 7. As the precipitation time increased, the ${\Delta}E^*$ value was also increased. Of the specimens immersed on day 1, the greatest color change in crowns polished with denture bur was observed in those immersed in red pepper paste, while the smallest color change was observed in those immersed in cola. On days 5 and 7, the greatest color change in crowns polished with denture bur was observed in those immersed in red wine. Crowns polished with silicone bur and immersed in soybean paste exhibited the smallest color change. Based on the results, compared to pumice polishing, silicone bur polishing results in better color stability, saves time and money, and is recommended for patients with temporary crowns.

The Design and Application of Vibrator Type(AM) Combination Apparatus for Improving Police Equipment for Fugitive Prevention (도주방지용 경찰장구의 기능개선을 위한 진동자 방식(AM) 결속장치 설계 및 응용)

  • Choi, Ki-Nam;Lee, Seon-Jeh
    • Convergence Security Journal
    • /
    • v.11 no.2
    • /
    • pp.13-24
    • /
    • 2011
  • Policemen judge the situations rationally and use their equipment such as handcuffs and rope within the purview, finding them needed to arrest criminals in the act who commit crimes which conforms to death penalty, life imprisonment or long imprisonment for over 3 years in accordance with Clause 10-2, Article 1 of the Police Mandate Law and prevent fleeing from them, defend their and others' lives and bodies, or if there are probable causes to be recognized that using equipment is necessary to restrain the interference with government officials in the execution of their duties. However, as the cases which the criminals run away in handcuffs or with both hands tied occur, it results in the waste of police force, distrust and enormous trouble in the pursuit of their duties. Therefore, if the way to perceive fleeing of criminals who have already worn the police equipment by some simple assistive devices without developing other new equipment, it will be very effective for police duties. This study is about the combination apparatus for fugitive prevention attached to the existing handcuffs and rope whose alert sounds let the staffs working inside the office perceive the fleeing of wanted criminals and examined suspects who wear the handcuffs or are tied up with rope, providing that they go through the exit where a transmitter and a receiver were set. The combination apparatus for fugitive prevention which the study introduces contains the connecting parts which connect a flexible tube(cognition tags inside of the tube) of connector equipped with the police equipment with the ends of the tube and the part where these two meet and which connect them inside of the tube. The connecting parts are easy to be attached to the police equipment such as handcuffs and rope, but hard to be dismantled by the people tied up with the equipment. It enables watchers to perceive the fleeing of wanted criminals and examined suspects who wear the handcuffs or are tied up with rope, providing that they go through the exit where a transmitter and a receiver were set. Plus, if it is combined together with the portable receiver, it can be installed on the patrol cars and easily adopted to supervise illegally accessing of evidences. It is also avaliable to be adjunctively utilized for the handcuffs provided and the cost is so reasonable. Owing to its snap-on way to the cuffs, it can clear up any invasion of privacy and it can not be used as a self-injury tool because of the soft tube. Using AM Tag minimizes the lack of malfunction.