• Title/Summary/Keyword: SN Ratio

Search Result 474, Processing Time 0.022 seconds

Compensation of female adults with openbite tendency (개방교합 경향을 갖는 성인 여성 환자들의 보상양상에 관한 연구)

  • Kim, Dong-Un;Yoo, Eem-Hak
    • The korean journal of orthodontics
    • /
    • v.32 no.1 s.90
    • /
    • pp.1-7
    • /
    • 2002
  • The purposes of this study were to observe the compensation pattern of human female adults with openbite tendency and to provide the decision criteria of the diagnosis and treatment planning for those patients. Fifty patients with anterior openbite and fifty-five Patients without anterior openbite patients were selected as a control and a test group. ODI of the all patients was below 66. Mean ages of the control and the test group were 23.88 ${\pm}$ 4.53 and 24.7 ${\pm}$ 6.20 years, respectively. Lateral cephalograms were taken and forty-one variables were measured. To identify the morphological differences between the groups, statistical analyses were performed. Statistically significant differences were found in the measured variables of lower face height, N-Me, ANS-Me, ANS-Me/N-Me ratio, Mx1-SN, Mx1-FH, Mx1-NA(mm), Mx1-APo, PP to Mx6, Mn1-NB(degree), Mn1-NB(mm). The test group showed decreased lower face height, N-Me, ANS-Me, ANS-Me/N-Me ratio, more uprighted and retruded maxillo-mandibular incisors. Overeruption of the maxillary first molar was found in the control group.

Survey of the Preferred Vertical Lip-Chin Ratio (상순과 턱의 수직 비율(vertical lip-chin ratio)에 대한 선호도 조사)

  • Kwon, Seong-Jun;Choi, Gab-Lim;Lim, Sung-Hoon;Kim, Kwang-Won
    • The korean journal of orthodontics
    • /
    • v.34 no.5 s.106
    • /
    • pp.408-416
    • /
    • 2004
  • The purpose of this study was to investigate the preference of Vertical Lip-Chin Ratio (=Sn-Stm/Stm-Me', hereafter VLCR) in Koreans. The assessors consisted of 44 dentists (male 22, female 22) and 430 lay persons (male 303, female 127). The survey was performed using a questionnaire asking the order of preference. The profiles presented in the questionnaire were based on the profiles of two males and two females, each morphed according to the VLCRs of 1/1.8, 1/1.9, 1/2.0. 1/2.1, 1/2.2. The results were as follows: The difference between males and females. and the difference betwwen dentists and lay persons in the preference of VLCR were not statistically apparent. The most Preferred VLCR was 1/1.9, and the least preferred VLCR was 1/2.2, These results Indicate that the preferred VLCR is smaller than the previously reported VLCR ratios based on the cephalometric evaluation of samples with favorable facial esthetics.

Comparative Validation of the Mixed and Permanent Dentition at Web-Based Artificial Intelligence Cephalometric Analysis (혼합치열과 영구치열 환자를 대상으로 한 웹 기반 인공지능 두부 계측 분석에서의 비교 검증)

  • Shin, Sunhahn;Kim, Donghyun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.49 no.1
    • /
    • pp.85-94
    • /
    • 2022
  • This retrospective study aimed to evaluate the difference in measurement between conventional orthodontic analysis and artificial intelligence orthodontic analysis in pediatric and adolescent patients aged 7 - 15 with the mixed and permanent dentition. A total of 60 pediatric and adolescent patients (30 mixed dentition, 30 permanent dentition) who underwent lateral cephalometric radiograph for orthodontic diagnosis were randomly selected. Seventeen cephalometric landmarks were identified, and 22 measurements were calculated by 1 examiner, using both conventional analysis method and deep learning-based analysis method. Errors due to repeated measurements were assessed by Pearson's correlation coefficient. For the mixed dentition group and the permanent dentition group, respectively, a paired t-test was used to evaluate the difference between the 2 methods. The difference between the 2 methods for 8 measurements were statistically significant in mixed dentition group: APDI, SNA, SNB, Mandibular plane angle, LAFH (p < 0.001), Facial ratio (p = 0.001), U1 to SN (p = 0.012), and U1 to A-Pg (p = 0.021). In the permanent dentition group, 4 measurements showed a statistically significant difference between the 2 methods: ODI (p = 0.020), Wits appraisal (p = 0.025), Facial ratio (p = 0.026), and U1 to A-Pg (p = 0.001). Compared with the time-consuming conventional orthodontic analysis, the deep learning-based cephalometric system can be clinically acceptable in terms of reliability and validity. However, it is essential to understand the limitations of the deep learning-based programs for orthodontic analysis of pediatric and adolescent patients and use these programs with the proper assessment.

Electrical properties of 0.05pb($Sn_{0.5}Sb_{0.5}O_3-xPbTiO_3-yPbZrO_3$ PZT System With variation Of PT/PZ (0.05pb($Sn_{0.5}Sb_{0.5}O_3-xPbTiO_3-yPbZrO_3$계에서 PT/PZ비 변화에 따른 전기적 특성)

  • 황학인;박준식;오근호
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.7 no.4
    • /
    • pp.589-598
    • /
    • 1997
  • The effects of PT/PZ ratio variations in a modified PZT system on crystal structure and electrical properties were studied. $0.05Pb(Sn_{0.5}Sb_{0.5})O_3+xPbTiO_3+yPbZrO_3$+0.4Wt% $MnO_2$(=0.55PSS+0.11PT+0.84PZ+0.4wt%$MnO_2$ ; x+y=0.95) systems with variations of PT/PZ from 0.50/0.45 to 0.l1/0.84 were sintered at $1250^{\circ}C$ for 2 hr, and then sintering density, crystal structure, dielctric, piezoelectric, pyroelectic and voltage responsity to infrared were investigated. Sintering density was increased from 7.52g/$\textrm {cm}^3$ to 7.82g/$\textrm {cm}^3$ with increasing PZ content. Dielectric constants at 1 KHz were decreased from 1147 to 193 with variation of PT/PZ from 0.50/0.45 to 0.l1/0.84 after poling of $4 KV_{DC}$/mm at $140^{\circ}C$ for 20 minutes. All Dielectric losses at 1 KHz were less than 1 % in all specimens. $K_{p}$ was increased near to 1 of PT/PZ, and maximun value of 48.2 % was .at 0.45/0.50. Pyroelectric coefficient of PT/PZ with 0.l1/0.84 was maximun value, 0.0541 C/$\m^2$K, and voltage responsity to infrared was 1.5 V.

  • PDF

레이저 유도 형광법(Laser Induced Fluorescence)을 이용한 플라즈마 방전 표시기(Plasma Display Panel)내의 전계 측정에 관한 연구

  • 김정훈;이준학;최영욱;양진호;황기웅
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.232-232
    • /
    • 1999
  • 교류형 플라즈마 방전 표시기(AC Plasma Display Panel, AC PDP)에 사용되는 플라즈마는 그 부피가 너무 작아서 플라즈마에 변화를 일으키지 않고 그 물성을 관측하기란 쉬운일이 아니다. 그래서 주로 PDP 내의 물성을 관측하는 데 시뮬레이션에 의존하게 된다. 그 물성중에 PDP내의 전계 분포에 대한 정보는 방전의 형성 및 소멸에 대한 많은 단서를 제공하고 있다. 특히 AC PDP의 경우, 유전체에 형성되는 벽적하(wall charge)가 방전의 형성 및 PDP 구동에 중요한 역할을 하는데, 이는 PDP 내의 전계 분포를 살펴봄으로써 대략 예측할 수 있다. 본 연구에서는 시뮬레이션에 의존하지 않고, 직접 레이저 유도 형광법을 이용하여 AC PDP 내의 전계를 측정하였다. 방전 가스인 헬륨(He)의 에너지 준위는 전계의 크기에 따라 에너지 준위가 변화하여, Rydberg(n$\geq$8) 준위가 여러 개의 준위로 나누어지는 현상이 일어나는데, 이를 Stack 효과라고 한다. 따라서 전계의 세기가 커짐에 따라서 각 준위와 준위 사이 값(splitting)이 커지는데, 이를 이용하면 전계를 측정할 수 있다. 즉, 헬륨 원자를 여기시키는 레이저 파장을 변화시키면서 관측되는 레이저 유도 형광 신호를 관측하면, 준위의 splitting을 관측할 수 있다. 본 연구에서는 PDP 내의 전계의 시간적 변화를 관측하였다. 50%, 40kHz의 구형파를 PDP의 두 전극에 가하였을 때, 플라즈마가 켜진 상태뿐만 아니라 플라즈마가 꺼진 후에도 전계에 의한 Splitting 신호가 관측이 되었는데, 전계로 환산하였을 때, 그 값은 대략 수 kV/cm의 값을 갖았는데, 이는 wall charge에 의한 값으로 사료된다.결과로 생각되어진다.플라즈마의 강도값을 입력하여 플라즈마의 radiation을 검출하고, 스퍼터링 공정중 실질적인 in-situ 정보로 이용하였다. PEM을 통하여 In/Sn의 플라즈마 강도변화를 조사하였다. 초기 In/Sn의 플라즈마 강도(intensity)는 강도를 100하여, 산소를 주입한 결과, plasma intensity가 35 줄어들었고, 이때 우수한 ITO 박막을 얻을 수 있었다. Pulsed DC power를 사용하여 아크 현상을 방지하였다. PET 상에 coating 된 ITO 박막의 표면저항과 광투과도는 4-point prove와 spectrophotometer를 이용하여 분석하였고, AES로 박막의 두께에 따른 성분비를 확인하였다. ITO 박막의 광투과도는 산소의 유량과 sputter 된 In/Sn ion의 plasma emission peak에 따라 72%-92%까지 변화하였으며, 저항은 37$\Omega$/$\square$ 이상을 나타내었다. 박막의 Sn/In atomic ratio는 0.12, O/In의 비율은 In2O3의 화학양론적 비율인 1.5보다 작은 1.3을 나타내었다.로 보인다.하면 수평축과 수직축의 분산 장벽의 비에 따라 cluster의 두께비가 달라지는 성장을 볼 수 있었고, 한 축 방향으로의 팔 넓이는 fcc(100) 표면의 경우 동일한 Ed+Ep값에 대응하는 팔 넓이와 거의 동일한 결과가 나타나는 것을 볼 수 있다. 따라서 이러한 비대칭적인 모양을 가지는 성장의 경우도 cluster 밀도, cluster 모양, cluster의 양 축 방향 길이 비, 양 축 방향의 평균 팔 넓이로부터 각 축 방향의 분산 장벽을 얻어낼 수 있을 것으로 보인다. 기대할 수 있는 여러

  • PDF

Synthesis and Characterization of Biodegradable MethoxyPoly(ethylene glycol)-Poly$(\varepsilon-caprolactone-co-L-lactide)$ Block Copolymers (메톡시폴리(에틸렌 글리콜)-폴리(카프로락톤-co-L-락타이드) 공중합체의 합성 및 특성 분석)

  • Hyun Hoon;Cho Young Ho;Jeong Sung Chan;Lee Bong;Kim Moon Suk;Khang Gilson;Lee Hai Bang
    • Polymer(Korea)
    • /
    • v.30 no.1
    • /
    • pp.28-34
    • /
    • 2006
  • A series of methoxypoly(ethylene glycol) $(MPEG)-poly(\varepsilon-co-L-lactide)$ (PCLA) diblock copolymers were synthesized by ring-opening polymerization of a mixture of $\varepsilon-caprolactone$ and L-lactide with different ratios in the presence of $Sn(Oct)_2$. The characterization of MPEG-PCLA diblock copolymers were examined by $^1H-NMR$, GPC, DSC, and XRD. Kinetic study on ring-opening polymerization of monomer mixtures was carried out in various conditions such as a variation with polymerization time, amount of catalyst, and temperature. The highest conversion obtained in 1.2 ratic of initiator venn catalyst at $110\;^{\circ}C$. The biodegradable characterization of MPEG-PCLA diblock copolymers in aqueous solution was carried out by using GPC for $1\~14$ weeks. The biodegradability of MPEG-PCLA diblock copolymers increased as the L-lactide content of diblock copolymers increased. In conclusion, we confirmed the dependence of polymerization rate according to various conditions. In addition, we can control the biodegradability of MPEC-PCLA diblock copolymers by changing the ratio of PCL and PLA block segment.

Effects of Process Variables on the Microstructure and Gas Sensing Characteristics of Magnetron Sputtered $\textrm{SnO}_2$Thin Films (마그네트론 스퍼터링 증착 조건에 따른 $\textrm{SnO}_2$ 박막의 미세구조와 가스검지특성 변화)

  • Kim, Jong-Min;Moon, Jong-Ha;Lee, Byung-Teak
    • Korean Journal of Materials Research
    • /
    • v.9 no.11
    • /
    • pp.1083-1087
    • /
    • 1999
  • Microstructures and the gas-sensing characteristics of the $\textrm{SnO}_2$ thin films were studied, which were deposited at various conditions (rf power, sample temperature, $\textrm{O}_2$/Ar ratio) by the rf magnetron sputtering. As a result, six typical microstructures were derived, such as amorphous(A), amorphous mixed with polycrystalline grains (A+P), polycrystalline with random crystalographic orientation (P), fine columnar (FC), coarse columnar (CC) and Zone T (T) with dense fiberous structure. Typically, A, A+ P, and P structures were formed when no $\textrm{O}_2$ was added to the sputter gas, whereas FC, CC, and T structures were obtained when $\textrm{O}_2$ was added. The A structure formed at low rf power and low temperature, the A+P at high rf power and low temperature, and the P at high rf power and high temperature. The FC structure was obtained at low rf power and low temperature. the CC at low rf power and high temperature, and the T at high rf power and low temperature. Results of the gas-sensing test of the sensor chips fabricated from the typical films indicated that the fine columnar microstructure shows the highest sensitivity both at $300^{\circ}C$ and $400^{\circ}C$. It was proposed that this is due to the high specific surface area of the micro-columns.

  • PDF

Effect of Ionic Molar Conductivity on Separation Characteristics of Heavy Metals by Nanofiltration Membranes in Waste Water (이온 몰 전도도가 나노여과막에 의한 폐수 중의 중금속 분리특성에 미치는 영향)

  • Oh, Jeong-Ik
    • Land and Housing Review
    • /
    • v.4 no.1
    • /
    • pp.119-124
    • /
    • 2013
  • Generally, the characteristic of nanofiltration membranes were catagorized into charged membrane, sieve effect, interaction between membarnes and target solutes. This study aims to investigate the effect item of heavy metal separation with view of charge nanofiltration membranes. The experiments of nanofiltration were conducted by nanofiltration set-up with operational pressure of 0.24 MPa at $25^{\circ}C$ by using synthetic wastewater containing 0.1mg/L of Cr, Fe, Cu, Zn, As, Sn, Pb. Nanofiltration membranes rejected heavy metals much better than chloride, sulfate and TOC, of which concentration in synthetic wastewater was higher than that of heavy metals. To consider rejection characteristics of various metals by nanofiltration membranes, separation coefficient, which is the molar conductivity ratio of the metal permeation rate to the chloride ion or TOC permeation rate, was introduced. In spite of different materials and different nominal salt rejection of nanofiltration membrane used, the separation coefficients of metals were nearly the same. These phenomena were observed in the relationship between the molar conductivity and the separation coefficient for heavy metals.

교류형 플라즈마 방전 표시기 방전유지 전압의 전압 상승 시간의 변화에 따른 방전 현상의 변화

  • 김중균;양진호;윤차근;황기웅
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.229-229
    • /
    • 1999
  • 교류형 플라즈마 방전 표시기(AC Plasma Display Panel, AC PDP)의 구동에서의 방전 현상은 기입방전, 유지방전, 소거 방전이 있다. 이중 유지 방전은 표시장치로서의 휘도와 계조의 표현을 위한 방전으로 표시기로서의 효율을 결정하게 된다. 본 연구에서는 유지 방전 전압의 상승 시간의 변화에 따른 방전현상과 휘도, 효율의 변화를 살펴 보았다. 방전 현상에서의 가장 큰 변화는 교류형 플라즈마 방전 표시기의 방전 개시 전압과 방전 유지 전압의 변화이다. 유지 전압의 상승시간이 증가할수록 방전 개시 전압과 방전 유지 전압의 변화이다. 유지 전압의 상승 시간이 증가할수록 방전 개시 전압과 방전 유지 전압의 차(sustain margin)는 감소하여 상승 시간이 1$\mu$s/100V 이상의 영역에서는 방전 개시 전압과 방전 유지 전압이 차이가 없어지게 된다. 이는 방전 유지 전극 위의 유전체에 쌓이게 되는 벽전하(wall charge) 양의 감소에 의한 방전 약화의 영향을 보여질 수 있다. 그러나 방전 유지 전압의 형태와 전류의 시간적인 변화를 살펴보면 이러한 약한 방전은 벽전하의 감소에 의한 방전 시의 전계 감소보다는 방전 전류의 발생 시간이 방전 전압이 증가하여 최고점에 이르지 못한 시간에 위치하여 방전이 형성될 때의 전계가 강하지 못하기 때문인 것을 알 수 있다. 방전 전류를 측정한 결과에 의하면 방전 전류의 시작은 변위 전류가 흐르고 난 후부터 시작되며 그 결과 방전 전류가 최고점에 도달하는 시간은 방전 전압 상승 시간이 길어질수록 낮은 전압에서 형성되게 된다. 또한 방전 유지 전압의 상승 시간이 길어질수록 플라즈마 방전표시기의 휘도와 효율은 낮아지고 이 결과 또한 약한 전계에서의 방전에 의한 결과로 생각되어진다.플라즈마의 강도값을 입력하여 플라즈마의 radiation을 검출하고, 스퍼터링 공정중 실질적인 in-situ 정보로 이용하였다. PEM을 통하여 In/Sn의 플라즈마 강도변화를 조사하였다. 초기 In/Sn의 플라즈마 강도(intensity)는 강도를 100하여, 산소를 주입한 결과, plasma intensity가 35 줄어들었고, 이때 우수한 ITO 박막을 얻을 수 있었다. Pulsed DC power를 사용하여 아크 현상을 방지하였다. PET 상에 coating 된 ITO 박막의 표면저항과 광투과도는 4-point prove와 spectrophotometer를 이용하여 분석하였고, AES로 박막의 두께에 따른 성분비를 확인하였다. ITO 박막의 광투과도는 산소의 유량과 sputter 된 In/Sn ion의 plasma emission peak에 따라 72%-92%까지 변화하였으며, 저항은 37$\Omega$/$\square$ 이상을 나타내었다. 박막의 Sn/In atomic ratio는 0.12, O/In의 비율은 In2O3의 화학양론적 비율인 1.5보다 작은 1.3을 나타내었다.로 보인다.하면 수평축과 수직축의 분산 장벽의 비에 따라 cluster의 두께비가 달라지는 성장을 볼 수 있었고, 한 축 방향으로의 팔 넓이는 fcc(100) 표면의 경우 동일한 Ed+Ep값에 대응하는 팔 넓이와 거의 동일한 결과가 나타나는 것을 볼 수 있다. 따라서 이러한 비대칭적인 모양을 가지는 성장의 경우도 cluster 밀도, cluster 모양, cluster의 양 축 방향 길이 비, 양 축 방향의 평균 팔 넓이로부터 각 축 방향의 분산 장벽을 얻어낼 수 있을 것으로 보인다. 기대할 수 있는 여러 장점들을 보고하고자 한다.성이 우수한 시

  • PDF

Modification of Palm Mid Fraction with Stearic Acid by Enzymatic Acidolysis Reaction (효소적 Acidolysis를 이용한 Stearic Acid 함유 팜중부유의 개질)

  • Jeon, Mi-Sun;Lee, Yun-Jeung;Kang, Ji-Hyun;Lee, Jeung-Hee;Lee, Ki-Teak
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.38 no.4
    • /
    • pp.479-485
    • /
    • 2009
  • The acidolysis was performed to produce structured lipid with palm mid fraction (PMF) and stearic acid for 7, 24, and 36 hr at $70^{\circ}C$. The reaction was catalyzed by lipozyme TLIM (immobilized lipase from Thermonyces lanuginosa, amount of 10% and 20% by weight of total substrates) in the shaking water bath. The reaction conditions for maximum incorporation of stearic acid on the structured lipid were obtained when molar ratio of PMF and stearic acid was 1:2; concentration of lipozyme TLIM was 20wt%; reaction temperature was $70^{\circ}C$; and reaction time was 36 hr. After reaction under this condition, incorporation of stearic acid in the structured lipid was obtained up to 36.3% while the major components of triacylglycerol were 1,2-dipalmitoyl-3-stearoylglycerol (PPS, 28.19 area%), 1-palmitoyl-2-oleoyl-3-stearoylglycerol (POS/PSO, 20.70 area%) and 1-palmitoyl-2,3-distearoylglycerol (PSS, 18.13 area%). However, the fatty acid composition at the sn-2 position suggested that the positional specificity of lipozyme TLIM was not observed due to the acyl migration.