• 제목/요약/키워드: SN Ratio

검색결과 474건 처리시간 0.038초

보통 및 저열시멘트를 이용한 고강도 콘크리트의 자기수축응력 및 건조수축응력 특성 (The Properties of Stress Induced by Autogenous Shrinkage and Dry Shrinkage for High Strength Concrete Using Type I and Type IV Cement)

  • 이웅종;엄태선;이종열
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(II)
    • /
    • pp.17-20
    • /
    • 2005
  • In this study, the properties of autogenous shrinkage stress and dry shrinkage stress for high strength concrete using Type I and Type IV cement were discussed. According to experimental results, autogenous shrinkage stress of SN30(the high strength concrete using type I cement) shows values higher than SL30(the high strength concrete using type IVcement). It is observed that the total shrinkage stress of SN30 is higher than that of SL30, because the ratio of autogenous shrinkage stress of the total shrinkage stress is relatively large. Therefore, SL30 is more effective to control or minimize the cracking of the high strength concrete, compared with SN30.

  • PDF

박막형 2차전지용 $SnO_2$음극 박막의 제작 및 특성 평가 (Fabrication and characterization of $SnO_2$ anode thin film for thin film secondary battery)

  • 이성준;신영화;윤영수;조원일
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 추계학술대회 논문집
    • /
    • pp.571-574
    • /
    • 2000
  • In this study, Tin oxide thin film for secondary battery was deposited on Pt/Ti/Si(100). It was fabricated by r.f. reactive sputtering with Tin metal target. At constant power (130W), pressure (Base 5$\times$10$^{-6}$ Torr, working 5$\times$10$^{-3}$ Torr) and at room temperature, it was fabricated by Ar/O2 gas ratio. After deposition, we got AFM & SEM to investigated surface of thin films and had XRD to find crystalline of thin films. Charge/discharge characteristics were carried out in 1M LiPF$_{6}$ , EC:DMC = 1:1 liquid electrolyte using lithium metal at room temperature.

  • PDF

화학기상증착 방법으로 성장된 $SnO_2$ 나노선의 특성 분석: 성장 온도와 산소유량에 따른 구조와 전기특성

  • 김윤철;하정숙
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2009년도 제38회 동계학술대회 초록집
    • /
    • pp.71-71
    • /
    • 2010
  • 최근 나노선의 우수한 전기적, 광학적 특성을 다양한 종류의 전자소자, 광소자, 그리고 센서에 응용하는 연구가 활발히 진행되고 있다. 그 중 $SnO_2$ 나노선은 n-type의 전기특성과 우수한 광 특성을 보이며, 전자소자, 광소자 뿐 아니라 다양한 종류의 가스 센서 제작에 널리 사용되고 있다. 본 연구에서는 화학기상증착법 (Chemical Vapor Deposition)으로 $SnO_2$ 나노선을 성장하여 전계방출효과 트랜지스터 (field effect transistor: FET)를 제작하여 전기적 특성을 측정하였다. 나노선의 성장 조건 (온도와 산소 유량) 에 따른 나노선의 구조, 화학조성, 전기적 특성을 체계적으로 조사하였다. 산소의 유량이 낮을 때는 온도에 따라 나노선의 크기와 전기 특성에 변화가 없었으나, 산소의 유량을 높이면 온도에 따라 나노선의 두께와 전기적 특성이 크게 변화하였다. 본 연구에서는 특히, FET 구조에서 on/off current ratio 가 $10^5$ 이상으로 매우 높은 나노선 제작이 가능하였다. 전기적 특성과 나노선의 결정구조, 화학적 조성을 함께 비교하여 성장 메커니즘을 이해하고자 한다.

  • PDF

저 전력용 CO가스 감지소자 (C Gas Sensors Operating at Relatively Low Temperature)

  • 이성필;이용현;이덕동;손병기
    • 대한전자공학회논문지
    • /
    • 제23권6호
    • /
    • pp.766-772
    • /
    • 1986
  • SnO2/Pt CO gas sensors operating at relatively low temperature were fabricated, and their performance characteristics were measured. When the mixing weight ratio of SnO2/Pt was 99.5/0.5, a good sensitivity to CO gas was obtained. And the experimental results were in consistent with the gas sensing model. The optimum operating, temperature range of the fabricated devices was 50-80\ulcorner and the response time was 15 sec. at 80\ulcorner in 1000 ppm CO ambient. The humidity dependence of sensitibity to CO gas could be reduced by adding hydrophokbic silica to the mixture of SnO2 and Pt. For the practical application of the fabricated devices, a CO gas alarming system has been developed.

  • PDF

$TiO_2$첨가에 의한 ZnO와 $SnO_2$의 일산화탄소 감응특성 변화 (The Changes of CO Gas Sensing Properties of ZnO and $SnO_2$ with Addition $TiO_2$)

  • 김태원;최우성;전선택
    • 한국재료학회지
    • /
    • 제8권4호
    • /
    • pp.312-316
    • /
    • 1998
  • ZnO와 $SnO_2$$ TiO_2$를 첨가시킨 $ZnO-TiO_2$$SnO_2$-$TiO_2$세라믹 복합체를 제작하여 1000ppm 일산화탄소에 대한 감응특성을 조사하였다. 상분석을 위해서 X-선 회절 분석을 하였고, 전자 주사 현미경을 이용해서 시편 파단면의 미세구조를 관찰했다. 일산화탄소 감도는 건조공기 분위기에서 측정한 저항($R_{dry air}$ )과 1000ppm 일산화탄소 분위기에서의 저항($R_{co}$ )을 측정하여 각각의 저항값의 비로 정의하였다. $TiO_{2}$첨가에 의한 ZnO의 일산화탄소 감도의 변화는 ZT5의 경우 최대 감도가 약 1.7배 감소하였고, $TiO _{2}$첨가에 의한 $SnO_{2}$의 일산화탄소 최대 감도는 약 2.5배 증가함으로써 비교적 $ZnO-TiO_2$배 증가함으로써 비교적 $ZnO-TiO_2$배 증가함으로써 비교적 $ZnO-TiO_2$복합체 보다는 $SnO_2$- $TiO_2$복합체의 일산화탄소 감응특성이 우수했다.

  • PDF

나노 가스 감지 소자의 특성에 미치는 촉매 구조의 영향 (Elect of Catalytic Configuration on Sensing Properties of Nano Gas Sensor)

  • 홍성제;;한정인
    • 한국전기전자재료학회논문지
    • /
    • 제18권10호
    • /
    • pp.917-923
    • /
    • 2005
  • In this paper, effect of catalytic configuration on the sensing properties of $SnO_2$ nanoparticle gas sensitive thick film was investigated. Two types of catalytic configuration, mono and binary, were made on the $SnO_2$ nanoparticle. In case of mono catalytic system, $3 wt\%$ Pd or Pt catalyst was doped onto the $SnO_2$ nanoparticle, respectively. In case of binary catalytic system, Pd and Pt was doped simultaneously with concentration ratio of 1:2 to 2:1 onto the $SnO_2$ nanoparticle. After doping, gas sensitive thick film was printed on alumina substrate and heat-treated at 450 to $600^{\circ}C$. Gas sensing properties was evaluated using 500 to 10,000 ppm $CH_4$ gas. As a result, gas sensitive thick film with binary catalytic system showed unstable phenomena that the gas sensitivity was changed according to aging time. In contrary, the mono catalytic system showed relatively stable phenomena despite of aging time. Especially, gas sensitive thick film doped with $3 wt\%$ Pt catalyst and heat-treated at $500^{\circ}C$ showed good sensing properties such as 0.57 of $R_{3500}/R_{1000}$ and very small variation within $3.5\%$ after aging for 5 hours, and response time was very short less than 20 seconds.

NiO-ZnO-$Fe_2O_3$-$TiO_2$-$SnO_2$ 계 Spinel 고용체의 생성과 발색에 관한 연구 (Formation and Color of the Spinel Solid Solution in NiO-ZnO-$Fe_2O_3$-$TiO_2$-$SnO_2$ System)

  • 이응상;이진성
    • 한국세라믹학회지
    • /
    • 제28권4호
    • /
    • pp.305-314
    • /
    • 1991
  • This study was conducted to research the formation and the color development of NiO-ZnO-Fe2O3-TiO2-SnO2 system for the purpose of synthesizing the spinel pigments which are stable at high temperature. After preparing ZnO-Fe2O3 as a basic composition, {{{{ chi }}NiO.(l-{{{{ chi }})ZnO.Fe2O3 system, {{{{ chi }}NiO.(l-{{{{ chi }})ZnO.TiO2 system, and {{{{ chi }}NiO.(l-{{{{ chi }})ZnO.SnO2 system were prepared with {{{{ chi }}=0, 0.2, 0.5, 0.7, 1 mole ratio respectively. The manufacturing was carried out at 128$0^{\circ}C$ for 30 minutes. The reflectance measurement and the X-ray analysis of these specimens were carried out and the results were summarized as follows. 1. In the specimens which included NiO, it was difficult for the spinel structure to be formed. 2. As increasing the contents of NiO and Fe2O3, all the groups which were yellow or green colored changed to brown. 3. NiO-ZnO-Fe2O3 system and NiO-ZnO-TiO2 system formed the spinel structure and the illmenite structure appeared in NiO-TiO2 system.

  • PDF

Investigation of long-term stability of pentacene thin-film transistors encapsulated with transparent $SnO_2$

  • Kim, Woo-Jin;Koo, Won-Hoe;Jo, Sung-Jin;Kim, Chang-Su;Baik, Hong-Koo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2005년도 International Meeting on Information Displayvol.II
    • /
    • pp.1276-1279
    • /
    • 2005
  • The long-term stability of pentacene thin-film transistors (TFTs) encapsulated with a transparent $SnO_2$ thin-film prepared by ion beam assisted deposition (IBAD) was investigated. With a buffer layer of thermally evaporated 100 nm $SnO_2$ film deposited prior to IBAD process, our encapsulated OTFTs sustained its initial field-effect mobility up to one month and then gradually degraded showing only 37% reduction compared to 90% reduction of non-encapsulated OTFTs after 100 days in air ambient. The encapsulated OTFTs also exhibited superior on/off current ratio of over $10^5$ to that of the unprotected devices $({\sim}10^4)$ which was reduced from ${\sim}10^6$ before aging. Therefore, the enhanced long-term stability of our encapsulated OTFTs should be attributed to well protection of permeation of $H_2O$ and $O_2$ into the devices by the IBAD $SnO_2$ thin-film which could be used as an effective inorganic gas barrier for transparent organic electronic devices.

  • PDF

III급 부정교합자의 연조직 측모 감별에 관한 연구 (DIFFERENTIAL DIAGNOSIS OF CLASS III PROFILE)

  • 황병남;이승훈;이정근;이재봉
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제22권2호
    • /
    • pp.174-183
    • /
    • 2000
  • This study was performed to investigate the characteristics of soft tissue profile of the class III malocclusion and to test the yardstick far differential diagnosis between surgical and orthodontic patients. Initial lateral cephalograms of orthodontic group(30 patients) that have acceptable occlusion and profile by orthodontic treatment alone and surgical group(30 patients) that have favorable occlusion and profile by combined surgical-orthodontic treatment were selected in Ajou university hospital. Powell and Burstone II analysis were made on the tracing. Descriptive, comparative, factor, cluster, and discriminant analysis were carried out with computer program. The results were as followings : 1. Patients who received surgery had a more concave profile and a longer lower facial height than patients who received orthodontic treatment alone. 2. Nasolabial angle, ratio of vertical height, and mentolabial sulcus were significantly different at the 5% level. And facial protuberance, upper lip protuberance, mentocervical angle, nasofrontal angle, nasomental angle, mandibular vertical height, angle between cervix and lower face, ratio of mandibular vertical height divided by cervical depth, ratio of vertical height between upper and lower lip, and maxillary protuberance were significantly different at the 1% level. 3. 8 factors were extracted and factor 2, 3, and 8 showed significant differences by factor analysis. 4. Orthodontic group (25) and surgical group (35) were classified by cluster analysis. 5. Discriminant function was D = 0.079Nasomental angle + 0.081Sn-Gn + 3.343Sn-Gn/C-Gn + 1.734Sn-St/St-Me' -26.460, and cutting score was 0, so we can discriminate that orthodontic group has the score above 0, and surgery group below 0. And 91.7% of original grouped cases were correctly classified.

  • PDF