• 제목/요약/키워드: SLICE

검색결과 981건 처리시간 0.026초

MR Technology to 4T

  • Vaughan, Thomas
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2003년도 제8차 학술대회 초록집
    • /
    • pp.103-105
    • /
    • 2003
  • After fifteen years of development, Magnetic Resonance (MR) technology for human imaging and spectroscopy is reaching a refined state with FDA approved 3T clinical products from Siemens, GE, and Philips. Broker has cleared CE approval with a 4T system. Varian supports a 4T system platform as well. Shielded magnets are standard at 3T from GE, Oxford, Magnex, and IGC. A shielded 4T whole body magnet is available from Oxford. Stronger switched gradients and dynamic shim coils, desired at any field, areespecially useful at higher static magnetic fields B0. In addition to the higher currents required for higher resolution slice or volume selection afforded by higher SNR, whole body gradient coils will be driven at increasing slew rates to meet the needs of new cardiac applications and other requirements. For example 3T and 4T systems are now being equipped with 2kV, 500A gradient coils and amplifiers capable of generating 4G/cm in 200msec, over a 67+/-cm bore diameter. High field EPI applications require oscillation rates at 1 kHz and higher. To achieve a benchmark 0.2 ppm shim over a 30cm sphere in a high field magnet, at least four stages of shimming need to be considered. 1) A good high field magnet will be built to a homogeneity spec. falling in the range of 100 to 150 ppm over this 30cm spherical "sweet spot" 2) Most modern high field magnets will also have superconducting shim coils capable of finding 1.5 ppm by their adjustment during system installation. 3) Passive ferro-magnetic shimming combined with 4) active, high order room temperature shim coils (as many as five orders are now being recommended) will accomplish 0.2 ppm over the 30cm sphere, and 0.1 ppm over a human brain in even the highest field magnets for human studies. Safety concerns for strong, fast gradients at any B0 field include acoustic noise and peripheral nerve stimulation. One or more of the mechanical decoupling methods may lead to quieter gradients. Patient positioning relative to asymmetric or short gradient coils may limit peripheral nerve stimulation at higher slew rates. Gradient designs combining a short coil for local speed and strength with a longer coil for coverage are being developed for 3T systems. Local gradients give another approach to maximizing performance over a limited region while keeping within the physiologically imposed dB0/dt performance limits.

  • PDF

Phantom-Validated Reference Values of Myocardial Mapping and Extracellular Volume at 3T in Healthy Koreans

  • Lee, Eunjin;Kim, Pan Ki;Choi, Byoung Wook;Jung, Jung Im
    • Investigative Magnetic Resonance Imaging
    • /
    • 제24권3호
    • /
    • pp.141-153
    • /
    • 2020
  • Purpose: Myocardial T1 and T2 relaxation times are affected by technical factors such as cardiovascular magnetic resonance platform/vendor. We aimed to validate T1 and T2 mapping sequences using a phantom; establish reference T1, T2, and extracellular volume (ECV) measurements using two sequences at 3T in normal Koreans; and compare the protocols and evaluate the differences from previously reported measurements. Materials and Methods: Eleven healthy subjects underwent cardiac magnetic resonance imaging (MRI) using 3T MRI equipment (Verio, Siemens, Erlangen, Germany). We did phantom validation before volunteer scanning: T1 mapping with modified look locker inversion recovery (MOLLI) with 5(3)3 and 4(1)3(1)2 sequences, and T2 mapping with gradient echo (GRE) and TrueFISP sequences. We did T1 and T2 mappings on the volunteers with the same sequences. ECV was also calculated with both sequences after gadolinium enhancement. Results: The phantom study showed no significant differences from the gold standard T1 and T2 values in either sequence. Pre-contrast T1 relaxation times of the 4(1)3(1)2 protocol was 1142.27 ± 36.64 ms and of the 5(3)3 was 1266.03 ± 32.86 ms on the volunteer study. T2 relaxation times of GRE were 40.09 ± 2.45 ms and T2 relaxation times of TrueFISP were 38.20 ± 1.64 ms in each. ECV calculation was 24.42% ± 2.41% and 26.11% ± 2.39% in the 4(1)3(1)2 and 5(3)3 protocols, respectively, and showed no differences at any segment or slice between the sequences. We also calculated ECV from the pre-enhancement T1 relaxation time of MOLLI 5(3)3 and the post-enhancement T1 relaxation time of MOLLI 4(1)3(1)2, with no significant differences between the combinations. Conclusion: Using phantom-validated sequences, we reported the normal myocardial T1, T2, and ECV reference values of healthy Koreans at 3T. There were no statistically significant differences between the sequences, although it has limited statistical value due to the small number of subjects studied. ECV showed no significant differences between calculations based on various pre- and post-mapping combinations.

3차원 두부영상의 기준좌표계 설정을 위한 연구: 1부 CT영상에서 3차원 계측점의 재현성 (Formulation of a reference coordinate system of three-dimensional (3D) head & neck images: Part I. Reproducibility of 3D cephalometric landmarks)

  • Park, Jae-Woo;Kim, Nam-Kug;Chang, Young-Il
    • 대한치과교정학회지
    • /
    • 제35권5호
    • /
    • pp.388-397
    • /
    • 2005
  • 이 연구는 기존의 두부방사선사진에서 사용되었던 계측점들을 3차원으로 재구성한 CT자료에서 다시 정의하고, 그 점들의 재현도를 조사함으로써. 재현성이 높고 해부학적 특징을 잘 표현하는 점들을 제안하고자 시행하였다. 3차원 영상에서 상대적 좌표 값을 구하기 위해 어느 4점도 같은 평면에 존재하지 않는 7개의 고정점을 선정하여 기준 좌표계를 설정하였다. V works 4.0 (Cybermed inc., Seoul. Korea)을 이용하여 고정점과 1점 설정을 위한 volume model (voxel size=4*4*2, threshold value-639)을 형성한 후 계측점을 선택하였으며. 나머지 점들은 모두 volume mode의 MPR 창을 이용하여 선정하였다 이렇게 선정한 계측점을 V 녁ㅎㄷ교 (Cybermed Inc.. Seoul, Korsa)로 이출하여 각 점의 상대적 공간 좌표 값을 구하였다 모든 자료는 2주 간격으로 2번 측정한 후 재현도를 계산하였다 각 계측점의 재현도는 x축 $0.13\~1.24mm$, y축 $0.23\~1.53mm$, z축 $0.15\~1.81mm$로 유사한 범위를 보였다 재현도가 우수한 것은 고정점을 이용한 1점이며 봉합에 의해 정의되는 J점의 재현도가 비교적 낮게 나타났다.

Accuracy of linear measurement using cone-beam computed tomography at different reconstruction angles

  • Nikneshan, Sima;Aval, Shadi Hamidi;Bakhshalian, Neema;Shahab, Shahriyar;Mohammadpour, Mahdis;Sarikhani, Soodeh
    • Imaging Science in Dentistry
    • /
    • 제44권4호
    • /
    • pp.257-262
    • /
    • 2014
  • Purpose: This study was performed to evaluate the effect of changing the orientation of a reconstructed image on the accuracy of linear measurements using cone-beam computed tomography (CBCT). Materials and Methods: Forty-two titanium pins were inserted in seven dry sheep mandibles. The length of these pins was measured using a digital caliper with readability of 0.01 mm. Mandibles were radiographed using a CBCT device. When the CBCT images were reconstructed, the orientation of slices was adjusted to parallel (i.e., $0^{\circ}$), $+10^{\circ}$, $+12^{\circ}$, $-12^{\circ}$, and $-10^{\circ}$ with respect to the occlusal plane. The length of the pins was measured by three radiologists, and the accuracy of these measurements was reported using descriptive statistics and one-way analysis of variance (ANOVA); p<0.05 was considered statistically significant. Results: The differences in radiographic measurements ranged from -0.64 to +0.06 at the orientation of $-12^{\circ}$, -0.66 to -0.11 at $-10^{\circ}$, -0.51 to +0.19 at $0^{\circ}$, -0.64 to +0.08 at $+10^{\circ}$, and -0.64 to +0.1 at $+12^{\circ}$. The mean absolute values of the errors were greater at negative orientations than at the parallel position or at positive orientations. The observers underestimated most of the variables by 0.5-0.1 mm (83.6%). In the second set of observations, the reproducibility at all orientations was greater than 0.9. Conclusion: Changing the slice orientation in the range of $-12^{\circ}$ to $+12^{\circ}$ reduced the accuracy of linear measurements obtained using CBCT. However, the error value was smaller than 0.5 mm and was, therefore, clinically acceptable.

횡보강근이 없는 100 MPa 이하 콘크리트의 철근 압축이음 강도와 이음길이 (Capacity and Length of Compression Lap Splice in Unconfined Concrete of 100MPa and Less Compressive Strength)

  • 천성철;이성호;오보환
    • 콘크리트학회논문집
    • /
    • 제22권5호
    • /
    • pp.659-666
    • /
    • 2010
  • 현행 설계기준식에 따르면 초고강도 콘크리트에서는 철근 인장이음길이보다 압축이음길이가 더 길어지는 현상이 발생된다. 압축이음은 단부 지압이 존재하므로, 인장이음보다 길 필요는 없다. 초고강도 콘크리트의 경제적 실용화를 위해 합리적인 압축이음강도의 평가가 필요하다. 이를 위해 설계강도 80, 100 MPa 콘크리트를 이용하여 횡보강근이 없는 압축이음 실험을 수행하였다. 실험 결과 압축이음강도는 콘크리트 강도의 제곱근에 비례하는 것으로 평가되었다. 지압에 의해 발현되는 이음강도는 이음길이와 무관하며 콘크리트 강도의 제곱근에 비례하는 것으로 평가되었다. 58개 실험체의 평균은 $16.5\;\sqrt{f_{ck}}$이다. 부착에 의해 발현되는 강도를 ACI 408식으로 평가한 결과 [실험값]/[이론값]의 비는 평균 0.94로, 인장이음의 부착강도와 거의 유사하였다. 따라서 인장이음강도에 대비한 압축이음강도의 향상은 단부 지압효과로 설명될 수 있다. 실험결과에서 분석된 이음길이와 콘크리트 강도의 영향 특성을 고려하여 압축이음강도 평가식과 압축이음길이 설계식을 제안하였다. 제안된 설계식은 통계적 기법에 기반을 두어, 이음부가 철근 재료강도와 동일한 수준의 신뢰성을 확보할 수 있다.

방사성의약품 검사 시 진단(CT)영상에 미치는 영향 (The Effects of Diagnostic Radiology Image on Radiopharmaceutical Testing)

  • 이은혜;이예슬;김가중;최준구
    • 대한디지털의료영상학회논문지
    • /
    • 제12권2호
    • /
    • pp.113-117
    • /
    • 2010
  • This research attempts to qualitatively evaluate the intensity change by radiopharmaceuticals and obtain computed tomography using phantom injected with various nuclide. Cylindrical phantom is used for comparing and analysing the effect on diagnosis image during radiopharmaceuticals inspection. Inside of the phantom, water is injected and computed tomography image is scanned. During nuclear medicine invitro, frequently used radiopharmaceuticals, $^{99m}TcO_4$ 20 mCi and $^{18}F$ 14 mCi, is diluted in the water phantom and scanned in the same method. Traverse image obtained by CT scan is divided into six traverse image in the same slice of each scanned image. CT-number(HU) value of 10 measuring point is measured in 2 cm interval based on the center of the phantom. Measured HU value, based on the water phantom, is compared with the image after injecting $^{99m}TcO_4$ and $^{18}F$. Average scale of water is 2.8~1.6 HU, $^{99m}TcO_4$ is 3.0~1.6 HU and $^{18}F$ is 1.2~0 HU. Average of water is $2.3{\pm}0.17$ HU, $^{99m}TcO_4$ is $2.2{\pm}0.85$ HU and F-18 is $0.7{\pm}0.95$ HU. Based on water, reduced value of about 0.1 HU and about 0.5 HU is acquired from $^{99m}TcO_4$ and F-18. Radionuclide used in nuclear medicine inspection utilizes 100~200 KeV energy and obtains image through scintillation camera and PET-CT utilizes 511 KeV positron annihilation energy to obtain image. What we learned from this research is that gamma rays from these energies used in CT scan for diagnosis purpose or radioactive therapy plan can change the intensity of the image. The nuclear medicine inspection for reducing the effect of emitted gamma ray diagnosis image should be obtained after a period of time considering half-life which would be reduced distortion or changed in image.

  • PDF

집성재 라미나용 낙엽송 재내 잔류 건조응력 변화 분석 (Analysis of residual drying stress in Larix Kaempferi wood used as glulam laminar)

  • 한연중;장윤성;박용건;정기영;홍정표;이전제;여환명
    • Journal of the Korean Wood Science and Technology
    • /
    • 제41권6호
    • /
    • pp.535-543
    • /
    • 2013
  • 본 연구에서 국산 낙엽송재의 공학목재로의 이용가능성, 특히 교호집성재 라미나로서의 이용가능성을 확인하기 위하여 열기건조 중과 건조 후 판재 내 잔류응력을 분석하였다. 연구결과를 통해 이쿼라이징 처리에 의한 함수율 동일화 효과가 증명되었고, 컨디셔닝 처리에 의한 잔류응력의 감소효과가 정량화되었다. 건조 중 목재 내 잔류응력 분석을 위하여 프롱법과 슬라이스법을 실시하였다. 프롱 제작 후 표면경화율을 측정하였고, 슬라이스의 절단 후 탄성변형량을 기준으로 표면으로부터 약 10 mm 깊이까지의 건조응력을 정량적으로 분석하였다. T10-C4와 T12-D5 열기건조 스케줄 적용 시 열기건조 중 판재 표면의 인장응력과 압축응력은 모두 2.2 MPa을 넘지 않음을 확인하였다. 낙엽송의 횡단방향 인장강도와 압축강도가 평균 2.65 MPa, 4.60 MPa인 점을 고려하면, 더욱 강한 건조스케줄 적용이 추천된다. 건조 후처리에 의해 폭굽음과 비틀림을 약 40% 줄일 수 있었다.

$^{99m}TC-HMPAO$ SPECT를 이용한 정상인 국소뇌혈류의 정량적 분석 (Normal Control Study of Cerebral Blood Flow by Tc-99m HM-PAO SPECT)

  • 문대혁;이범우;이경한;최윤호;정준기;이명철;고창순;윤병우;이남수;노재규;명호진;궁성수
    • 대한핵의학회지
    • /
    • 제23권2호
    • /
    • pp.155-163
    • /
    • 1989
  • Regional cerebral perfusion was evaluated in 15 normal controls by single photon emission computed tomography using $^{99m}Tc$ HM-PAO. For quantitative analysis, 13 pairs of homologous region of interest (ROI) were drawn on three transverse slices matching the vascular territories and cerebral cortices, and normal values of 3 semiqunatitative indices including 'Right to left ratio'(R/L ratio), 'Regional index'(RI), and 'Region to cerebellum ratio'(R/cbll ratio) were calculated. Mean values of R/L ratios of homotogous regions were ranged from 0.985 to 1.023, and mean ${\pm}2$ s.d. of all regions did not exceed 11% of mean. Significant difference of RIs (mean count per voxel of a ROI/mean count per voxel of total ROIs) between regions were found (p<0.001) with highest values in occipital cortex and cerebellum. After attenuation correction, RIs in deep gray, cranial portion of anterior cerebral artery and vascular territories in the 2nd slice increased significantly (p < 0.05-0.001), but vise versa in other ROIs. Region to cerebellum ratios also showed regional difference similar to RIs.

  • PDF

Characterization of Streptomyces Species Causing Potato Scab in Korea: Distribution, Taxonomy, and Pathogenicity

  • Lim, Chun-Keun;Park, Duck-Hwan;Kim, Jeom-Soon;Cho, Jun-Mo;Kwon, Soon-Wo;Hur, Jang-Hyun
    • The Plant Pathology Journal
    • /
    • 제19권1호
    • /
    • pp.13-18
    • /
    • 2003
  • From 1996 to 1999, potato-growing areas in Korea were surveyed for identification and distribution of potato scab pathogens. Potato scab was widely distributed in the mass cultivation areas, especially in Jriu island, southern areas of Chonnam and Gyounggi provinces, and the alpine area of Gangwon province. Jeju island was the most affected area by this disease. A total of 55 Streptomyces strains were isolated from potato scab lesions, among which 40 strains were pathogenic on progeny tubers. Among the pathogenic strain, 21 strains were identified as previously described S. scabies, 7 Strains as S. turgidiscabies, and 5 Strains as S. acidiscabies, while 7 strains were observed as having distinct phenotypic properties. These strains were classified into six distinct clusters based on phenotypic characteristics and selected representative strains for each cluster. S. scabies (S33) had grey spores in a spiral chain. Mean-while, S. turgidiscabies (S27) had grey spores, S. acidiscabies (S71) had white spores, S. luridiscabiei (S63) had yellow-white spores, S. puniciscabiei (S77) had purple-red spores, and S. niveiscabiei (S78) had thin and compact white spores, all in a rectiflexuous chain. Pathogenicity was determined by the production of thaxtomin A and homologs of necl and ORFtnp genes. In TLC, representative strains S27, S71, S63, S77, and S78 produced a yellow band that co-migrated with the authentic thaxtomin A. However, thaxtomin A was not detected in chloroform extracts from oatmeal broth culture and Slice tuber tissue of S. luridiscabiei (S63) and S. puniciscabiei (S77) by HPLC analysis. In addition, no homologs of necl and ORFtnp genes in S. acidiscabies (S71), S. luridiscabiei (S63), S. puniciscabiei (S77), and S. niveiscabiei (S78) were detected by PCR and Southern hybridization analysis.

대황(大黃)의 항산화와 신경세포손상 보호효능에 대한 연구 (Anti-Oxidative and Neuroprotective Effects of Rhei Rhizoma on BV-2 Microglia Cells and Hippocampal Neurons)

  • 명성하;김연섭
    • 동의생리병리학회지
    • /
    • 제19권3호
    • /
    • pp.647-655
    • /
    • 2005
  • This study demonstrated anti-oxidative and neuroprotective effects of Rhei Rhizoma. Anti-oxidative effects were studied on BV-2 microglia cells damaged by $H_2O_2$ and nitric oxide. Neuroprotective effects were studied by using oxygen/glucose deprivation of the organotypic hippocampal slice cultures. The results obtained are as follows; The groups treated with 0.5 and 5 mg/ml of Puerariae Radix revealed significant decreases of neuronal cell death area and cell death area percentages in CA1 region of ischemic damaged hippocampus cultures during whole 48 hours of the experiment. The group treated with 50 mg/ml of Puerariae Radix demonstrated decreases of neuronal cell death area and cell death area percentages in CA1 region, but these were not significant statistically. The groups treated with 0.5 and 5 mg/ml of Puerariae Radix revealed significant decreases of neuronal cell death area and cell death area percentages in dentate gyrus of ischemic damaged hippocampus cultures during whole 48 hours of the experiment. The group treated with 50 mg/ml of Puerariae Radix demonstrated decreases of neuronal cell death area and cell death area percentages in dentate gyrus, but these were not significant statistically. The groups treated with 0.5 and 5 mg/ml of Puerariae Radix revealed significant decreases of TUNEL-positive cells in both CA1 region and dentate gyrus of ischemic damaged hippocampus cultures. The group treated with 50 mg/ml of Puerariae Radix demonstrated significant decrease of TUNEL-positive cells in CA1 region, but not in dentate gyrus of ischemic damaged hippocampus. The groups treated with 0.5 and 5 mg/ml of Puerariae Radix revealed significant decreases of LDH concentrations in culture media of ischemic damaged hippocampus cultures. The group treated with 50 mg/ml of Puerariae Radix demonstrated decrease of LDH concentrations in culture media, but it was not significant statistically. The groups treated with 0.5 and 5 mg/ml of Puerariae Radix revealed significant increases of cell viabilities of BV-2 microglia cells damaged by $H_2O_2$. The group treated with 50 mg/ml of Puerariae Radix demonstrated increase of cell viability of BV-2 microglia cells, but it was not significant statistically. The group treated with 0.5 mg/ml of Puerariae Radix revealed significant increase of cell viability of BV-2 microglia cells damaged by nitric oxide. The groups treated with 5 and 50 mg/ml of Puerariae Radix demonstrated increases of cell viabilities of BV-2 microglia cells, but these were not significant statistically. These results suggested that Puerariae Radix revealed neuroprotective effects through the control effect of apoptosis and oxidative damages.