• Title/Summary/Keyword: SIMULEX

Search Result 33, Processing Time 0.018 seconds

The Improvement of Evacuation Performance for Discount-Store in Underground (할인점 지하매장의 피난성능 개선에 관한 연구)

  • 김영일;윤명오;김종훈;김운형
    • Fire Science and Engineering
    • /
    • v.15 no.1
    • /
    • pp.93-99
    • /
    • 2001
  • This study aims to improve the Evacuation Performance o( the I)inc()unto-store in underground that is rapidly new shopping store in Korea. In this paper, The architectural properties of the floor plan and section was reviewed with egress focus, occupant load density of the Discount-store was surveyed and the procedure and method of performance based egress design for this occupancy was analysed with SIMULEX model and calculation method. As a result of modeling, more longer available safe egress time (ASET) is expected than required safe egress time (RSET)in underground discount-store. In order to improve the Evacuation Performance for this type occupancy, egress capacity including escape stair, aisle width, escape door is calculated with based on occupant load density and review of shopping cart's structure and size and maximum escape capacity of the cash counter.

  • PDF

A Study on the Evacuation Planning in the Multiplex Cinema (멀티플렉스 영화관의 피난계획에 관한 연구)

  • So Eun-Tark;Song Byung-Ha
    • Korean Institute of Interior Design Journal
    • /
    • v.14 no.3 s.50
    • /
    • pp.147-155
    • /
    • 2005
  • As multiplex theaters are increasing rapidly in number, concerns over the evacuation process in case of fire emergency are also increasing. The study investigates the users' awareness and recognition of evacuation route by the method of questionnaire, and analyzes the users' behavior in choosing the route by the simulation program called Simulex. Among others, findings indicate a vast majority of the users are unaware of the proper route in the emergency, yet anticipate to evacuate by it, instead of the entry/exit route that they are familiar with. This aspect, however, can be useful to provide the proper route of evacuation for the users, if an appropriate information is given that the entry/exit route is also used as an emergency egress. The simulation shows heavy congestion at the closer evacuation route from the exit, and distinctly less traffic at the farther means of egress. Based on this natural phenomenon, it is suggested that the emergency stair should be nearby and aligned with the exit from auditorium. Although the present building regulation only requires a minimum dimension at each route, there is a need to widen the passageway that is likely to be recognized easily and subsequently overcrowded in case of fire emergency.

A Study on Emergency Evacuation Route Planning and USN-Based Induction Activities of Correctional Facilities (교정시설의 비상시 피난경로계획 및 USN기반 대피유도활동에 관한 연구)

  • Park, Joo-Hyung;Park, Jong-Hyun
    • Fire Science and Engineering
    • /
    • v.25 no.2
    • /
    • pp.39-46
    • /
    • 2011
  • In correctional facilities with majority of occupants in custody, the safe evacuation guide without getaway accidents should be very important due to complexity in escape paths. Fire causes are various in correctional facilities, for example, arson fire is a major cause in mental treatment facilities, however, old facilities or carelessness of flammable materials consist of fire causes in jail facilities. Both types of correctional facilities are the same in terms of many casualties from the fire cases. The thesis focus on escape paths and evacuation guide plans on the basis of analysis on fire cases and structural vulnerability, and then an electronic unlocking system is concededly installed for safe evacuation of occupants in custody without getaway accidents. Especially, the effect of the electronic unlocking system is going to be analyzed on the basis of RSET (required safe egress time) in order to realize for the occupants to evacuate safely to the front yard in case of emergency. In conclusion, if electronic security allowed system with USN (Ubiquitous Sensor Networks) technology should be installed in multi-storey correctional buildings, it is proposed that the occupants in custody might be a guided safely without getaway trials.