• Title/Summary/Keyword: SHE-PWM technique

Search Result 7, Processing Time 0.024 seconds

Reconfigurable Selective Harmonic Elimination Technique for Wide Range Operations in Asymmetric Cascaded Multilevel Inverter

  • Kavitha, R;Rani, Thottungal
    • Journal of Power Electronics
    • /
    • v.18 no.4
    • /
    • pp.1037-1050
    • /
    • 2018
  • This paper presents a novel reconfigurable selective harmonic elimination technique to control harmonics over a wide range of Modulation Indexes (MI) in Multi-Level Inverter (MLI). In the proposed method, the region of the MI is divided into various sectors and expressions are formulated with different switching patterns for each of the sectors. A memetic BBO-MAS (Biogeography Based Optimization - Mesh Adaptive direct Search) optimization algorithm is proposed for solving the Selective Harmonic Elimination - Pulse Width Modulation (SHE-PWM) technique. An experimental prototype is developed using a Field Programmable Gate Array (FPGA) and their FFT spectrums are analyzed over a wide range of MI using a fluke power logger. Simulation and experimental results have validated the performance of the proposed optimization algorithms and the reconfigurable SHE-PWM technique. Further, the sensitivity of the harmonics has been analyzed considering non-integer variations in the magnitude of the input DC sources.

A Study on the PWM Strategy and Gear Changing Techniques of an Inverter for Variable Speed Drives on Traction Motors (견인전동기 가변속 운전을 위한 인버터의 PWM 방법 및 패턴 절환기법에 관한 연구)

  • Seo, Yeong-Min;Park, Yeong-Jin;Hong, Sun-Chan
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.11
    • /
    • pp.646-654
    • /
    • 1999
  • This paper deals with PWM patterns for harmonic reduction in inverter fed traction motors and the gear changing techniques for the variable speed drive of traction motor. GTOs are used as switching device of inverter because traction motor is a large load. To derive PWM rattern which can minimize the harmonics with the limited switching frequency, the output current and torque characteristic of SPWM and SHE PWM was analyzed. GTO inverter used for traction motor drive includes harmonics in the output current and torque by the limitation of switching frequency. However, the hybrid PWM method that adopt SPWM in the range of low frequency and SHE PWM in upper frequency range can achieve less harmonic characteristics in GTO inverters. If the traction motor is driven in variable speed by the proposed PWM pattern, 7 times of gear changing is needed. At the instant of the mode change, magnetic flux and torque may be altered and the large current flow. To reduce such an undesirable transient behavior, it is also presented the technique for the gear changing of inverter fed traction motor drive operated with the hybrid PWM. The results are verified by simulations and experiments.

  • PDF

Increasing the Range of Modulation Indices with the Polarities of Cells and Switching Constraint Reliefs for the Selective Harmonic Elimination Pulse Width Modulation Technique

  • Najjar, Mohammad;Iman-Eini, Hossein;Moeini, Amirhossein
    • Journal of Power Electronics
    • /
    • v.17 no.4
    • /
    • pp.933-941
    • /
    • 2017
  • In this paper an improved low frequency selective harmonic elimination-PWM (SHE-PWM) technique for Cascaded H-bridge (CHB) converters is proposed. The proposed method is able to eliminate low order harmonics from the output voltage of the converter for a wide range of modulation indices. To solve SHE-PWM equations, especially for low modulation indices, a modified method is used which employs either the positive or negative voltage polarities of H-bridge cells to increase the freedom degrees of each cell. Freedom degrees of the switching angles are also used to increase the range of available solutions for non-linear SHE equations. The proposed SHE methods can successfully eliminate up to $25^{th}$ harmonic from a 7-level output voltage by using just nine switching transitions or a 150 Hz switching frequency. To confirm the validity of the proposed method, simulation and experimental results have been presented.

On-line Techniques of SHE-PWN for Current Source GTO Converter (전류형 GTO 컨버터의 SHE-PWM 실시간제어기법)

  • 최재호;팽성일;채경훈
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.6
    • /
    • pp.523-530
    • /
    • 1999
  • This paper presents the on -line techniques of SHE-PvVI\I for GTO current source converter. The look-up t table is linearized with this proposed method so that the tum-on/off periods of the GTO switches can be c computed in real-time for any modulation index. This allows the rapid and continuous regulation of the DC O output current while producing the sinusoidal AC input current waveform and unity power factor. The l linearized S}lE-PW~I technique and the high power factor control scheme are Prolxlsed and their‘ performance i is tested analytically. The validity of this proposed technique is well verified through the simulation and e experimental results.

  • PDF

A Study on the SHE PWM Inverter Using the Linearized Characteristics of Switching Angle for Carrier Wave (선형화한 스위칭각 특성파형을 반송파로 사용한 SHE PWM인버터에 관한 연구)

  • Kim, Kwon-Ho;Yoong, Kwan-Cheol;Song, Joong-Ho;Kim, Kwang-Bae;Lyou, Kyoung;Park, Gwi-Tae
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.39 no.7
    • /
    • pp.668-679
    • /
    • 1990
  • The fully digitalized inveter has some difficulties in implementation because of the limitation of available memory capacity and computation time. This paper describes a new PWM(Pulse Width Modulation) Inverter technique which linearizes switching angle characteristics of SHEPWM(Selected Harmonic Eliminatin Pulse Width Modulation) Inverter. Also the detailed description of the scheme along with the realization is presented. The simulation and experimental results show that the proposed schemes have the advantates such as good voltage waveforms and memory-saving.

  • PDF

A Harmonic Elimination Method of PWM Inverter Using Walsh-Fourier Transform (Walsh-Fourier 변환을 사용한 PWM 인버어터의 고조파 제거 방법)

  • Ahn, Doo-Soo;Won, Chung-Yuen;Lee, Hae-Ki;Kim, Tae-Hoon;Kim, Hack-Seong
    • Proceedings of the KIEE Conference
    • /
    • 1989.11a
    • /
    • pp.296-300
    • /
    • 1989
  • The paper proposes a method to eliminate harmonics of PWM inverter fed induction motor system using Walsh series. In other words, this paper presents technique of the selective harmonics elimination(SHE) by W-FT series in three phase PWM inverter output waveform. A microprocessor(8086 CPU) - controlled three phase induction motor system in order to verify this algorithm is present. It is designed for a three output voltage in the 1$\sim$60 Hz inverter with the 5th and 7th harmonics, 5th, 7th, 11th, and 13th, harmonics eliminated, and with the fundamental wave amplitude proportional to the output frequency. In the PWM inverter, dead time circuit is inserted in the switching si gnats to prevent the de link shortage. This paper is deals with quantative prediction of dead-time effect and its compensation in PWM inverters. The performance of the compensation circuits is confirmed by the experiment.

  • PDF

Real time Implementation of SHE PWM in Single Phase Matrix Converter using Linearization Method

  • Karuvelam, P. Subha;Rajaram, M.
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.4
    • /
    • pp.1682-1691
    • /
    • 2015
  • In this paper, a real time implementation of selective harmonic elimination pulse width modulation (SHEPWM) using Real Coded Genetic Algorithm (RGA), Particle Swarm Optimization technique (PSO) and a new technique known as Linearization Method (LM) for Single Phase Matrix Converter (SPMC) is designed and discussed. In the proposed technique, the switching frequency is fixed and the optimum switching angles are obtained using simple mathematical calculations. A MATLAB simulation was carried out, and FFT analysis of the simulated output voltage waveform confirms the effectiveness of the proposed method. An experimental setup was also developed, and the switching angles and firing pulses are generated using Field Programmable Gate Array (FPGA) processor. The proposed method proves that it is much applicable in the industrial applications by virtue of its suitability in real time applications.