• Title/Summary/Keyword: SHA1

Search Result 206, Processing Time 0.028 seconds

Multidimensional Networking Application of Ship Black Box and Forensic Data Extraction (다차원 네트워킹을 적용한 선박 블랙박스에서 Forensic자료 생성)

  • Park, Dea-Woo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.10a
    • /
    • pp.387-390
    • /
    • 2009
  • Digital devices that apply Ubiquitous-IT Convergence in ship manufacture are used as ship automation device. Need sailing data recording of ship black box that equip integrity and consecutiveness as legal confesser fare that inquire responsibility whereabouts of disaster such as fire of ship. It is research that create Forensic data from ship black box using Multidimensional networking that use ZigBee radio short distance communications division Wireless LAN with short distance RFID sensor that is used in ship in this treatise, UWB communication, GPS and artificial satellite. Sailing recording of shipping that is recorded to black box is transmited, and stores doubly by real time on ship insurance company and ship administration recording membrane using SHA-1 hash function and secure consecutiveness and integrity as Forensic data through artificial satellite encoding by 3DES 1024bit.

  • PDF

Blocking and investigation of child pornography using child pornography profiling system of National Police Agency (경찰청 아동음란물프로파일링 시스템을 이용한 아동음란물 차단 및 수사 방안)

  • Lee, Sang Duk
    • Journal of Digital Forensics
    • /
    • v.12 no.3
    • /
    • pp.97-108
    • /
    • 2018
  • Computer technology and Internet advances enable easy massive file transfer by messenger, email, and web hard service users this means that a child pornography file owner who is illegally possessing itself can quickly transfer that to other users However there are currently no specific ways to prevent or block the distribution of child pornography between messenger, email, and web hard service users. in this paper, we propose a method to prevent the distribution of child pornography using the MD5, SHA-1 hash value stored in the 'police Child pornography Profiling system' and to identify the child pornography suspects using the subscriber information. the user extracts the hash value of the file before distributing the file, compared it with police system, and if it has the same value, blocks the transmission of the file and sends warning to the owner. the service provider sends the subscriber information to investigation agency child pornography owners can conduct a quick and accurate investigation.

Factors Affecting Intention to Use Smartphone Healthcare Applications (스마트폰 헬스케어 어플리케이션 수용의도에 영향을 미치는 요인)

  • Park, Mijeong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.4
    • /
    • pp.143-153
    • /
    • 2017
  • This was a descriptive survey to determine the intention of users to use smartphone healthcare applications (SHAs) and to clarify factors that may influence such intention. The data were collected during the month of April in 2015, using a structured self-report questionnaire that was distributed to 300 participants aged 20 to 70 years; 285 complete copies were used for the final analysis. The data were analyzed using descriptive statistics, independent t-test, one-way ANOVA, Pearson correlation coefficients, and hierarchical multiple regression. First, according to the results, the average intention to use SHAs was 3.28 out of 5, which varied according to age, final education, economy level, vacation, current disease, total period of smartphone use, and etc. Second, significant correlations were shown by exercise behavior, dietary management behavior, stress management, satisfaction with smartphone use, and satisfaction with using SHAs. Third, the explanatory power of the predictive model involving all general, health-related, smartphone use-related, and SHA use-related factors was 45.5%; and the economic level, interest, status, and awareness satisfaction of patients using SHA were identified to be the main influential factors. The results indicate that SHA developers need to put efforts into improving consumers' app recognition and to develop plans in provoking consumers' interests to increase the use of SHAs.

An Extensible Transaction Model for Real-Time Data Processing (실시간 데이타 처리를 위한 확장 가능한 트랜잭션 모델에 관한 연구)

  • 문승진
    • Journal of Internet Computing and Services
    • /
    • v.1 no.2
    • /
    • pp.11-18
    • /
    • 2000
  • In this paper we present a new extensible model based upon the concept of subtransactions in real-time transaction systems. The nested transaction model originally proposed by J. Moss is extended for real-time uniprocessor transaction systems by adding explicit timing constraints. Based upon the model, an integrated concurrency control and scheduling algorithm is developed, that not only guarantees timing constraints of a set of real-time transactions but also maintains consistency of the database. The algorithm is based on the priority ceiling protocol of Sha et al. We prove that the Real-Time Nested Priority Ceiling Protocol prevents unbounded blocking and deadlock, and maintains the serializability of a set of real-time transactions. We use the upper bound on the duration that a transaction can be blocked to show that it is possible to analyze the schedulability of a transaction set using rate-monotonic priority assignment. This work is viewed as a step toward multiprocessor and distributed real-time nested transaction systems. Also, it is possible to be extended to include the real-time multimedia transactions in the emerging web-based database application areas.

  • PDF

Meta-analysis of Outcomes Compared between Robotic and Laparoscopic Gastrectomy for Gastric Cancer

  • Liao, Gui-Xiang;Xie, Guo-Zhu;Li, Rong;Zhao, Zhi-Hong;Sun, Quan-Quan;Du, Sha-Sha;Ren, Chen;Li, Guo-Xing;Deng, Hai-Jun;Yuan, Ya-Wei
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.8
    • /
    • pp.4871-4875
    • /
    • 2013
  • This meta-analysis was performed to evaluate and compare the outcomes of robotic gastrectomy (RG) and laparoscopic gastrectomy (LG) for treating gastric cancer. A systematic literature search was carried out using the PubMed database, Web of Knowledge, and the Cochrane Library database to obtain comparative studies assessing the safety and efficiency between RG and LG in May, 2013. Data of interest were analyzed by using of Review Manager version 5.2 software (Cochrane Collaboration). A fixed effects model or random effects model was applied according to heterogeneity. Seven papers reporting results that compared robotic gastrectomy with laparoscopic gastrectomy for gastric cancer were selected for this meta-analysis. Our metaanalysis included 2,235 patients with gastric cancer, of which 1,473 had undergone laparoscopic gastrectomy, and 762 had received robotic gastrectomy. Compared with laparoscopic gastrectomy, robotic gastrectomy was associated with longer operative time but less blood loss. There were no significant difference in terms of hospital stay, total postoperative complication rate, proximal margin, distal margin, numbers of harvested lymph nodes and mortality rate between robotic gastrectomy and laparoscopic gastrectomy. Our meta-analysis showed that robotic gastrectomy is a safe technique for treating gastric cancer that compares favorably with laparoscopic gastrectomy in short term outcomes. However, the long term outcomes between the two techniques need to be further examined.

The expanded LE Morgenstern-Price method for slope stability analysis based on a force-displacement coupled mode

  • Deng, Dong-ping;Lu, Kuan;Wen, Sha-sha;Li, Liang
    • Geomechanics and Engineering
    • /
    • v.23 no.4
    • /
    • pp.313-325
    • /
    • 2020
  • Slope displacement and factor of safety (FOS) of a slope are two aspects that reflect the stability of a slope. However, the traditional limit equilibrium (LE) methods only give the result of the slope FOS and cannot be used to solve for the slope displacement. Therefore, developing a LE method to obtain the results of the slope FOS and slope displacement has significance for engineering applications. Based on a force-displacement coupled mode, this work expands the LE Morgenstern-Price (M-P) method. Except for the mechanical equilibrium conditions of a sliding body adopted in the traditional M-P method, the present method introduces a nonlinear model of the shear stress and shear displacement. Moreover, the energy equation satisfied by a sliding body under a small slope displacement is also applied. Therefore, the double solutions of the slope FOS and horizontal slope displacement are established. Furthermore, the flow chart for the expanded LE M-P method is given. By comparisons and analyses of slope examples, the present method has close results with previous research and numerical simulation methods, thus verifying the feasibility of the present method. Thereafter, from the parametric analysis, the following conclusions are obtained: (1) the shear displacement parameters of the soil affect the horizontal slope displacement but have little effect on the slope FOS; and (2) the curves of the horizontal slope displacement vs. the minimum slope FOS could be fitted by a hyperbolic model, which would be beneficial to obtain the horizontal slope displacement for the slope in the critical state.

Scale and Structure of Pharmaceutical Expenditure for the year 2006 in Korea (우리나라 2006년 약제비의 규모 및 구성)

  • Jeong, Hyoung-Sun;Lee, Jun-Hyup
    • Health Policy and Management
    • /
    • v.18 no.3
    • /
    • pp.110-127
    • /
    • 2008
  • Expenditures on pharmaceuticals of different concepts were estimated and their functional, financing and providers' breakdowns were examined in line with the OECD's System of Health Accounts (SHA) manual. This study also shows the way such estimates are made. The results are then analyzed particularly from the international perspective. Data from both Household Survey by the National Statistical Office and the National Health and Nutritional Survey by the Ministry of Health and Welfare of Korea were used to estimate pharmaceutical expenditures that. are financed by out-of-pocket payments of the household, while national health insurance data etc. were used for estimation of pharmaceutical expenditures that are financed by public funding sources. The 'per capita expenditure on pharmaceutical/medical non-durables' in Korea stood at 380 US$ PPPs, less than the OECD average of 443 US$ PPPs in 2006, but its share of the per capita health expenditure of 25.9% noticeably outnumbered the OECD average of 17.1%, due partly to low per capita health expenditure as a denominator of the ratio. This indicates that Koreans tend to spend less on health care than an OECD average, while tending to spend more on pharmaceuticals than on other health care services, much like the pattern found in relatively low income countries. An international pharmaceuticals pricing mechanism is most likely responsible for such a tendency. In addition, it is to be noted that the percentage comes down to 21.0%, when expenditures on both medical non-durables and herbal medicine, which is locally quite popular among the elderly, have been excluded.

Improvement of an hydroxyapatite bead adherence assay for streptococcus sanguis (Streptococcus sanguis의 구형 Hydroxyapatite 비드에의 부착 Assay 방법의 개량)

  • 최선진;이시영;송요한
    • Korean Journal of Microbiology
    • /
    • v.27 no.1
    • /
    • pp.48-55
    • /
    • 1989
  • The purpose of the present investigation was to improve several procedures being used in the adherence assay of Streptococcus sanguis cells to hydroxyapatite (HA) beads and to study the effect of the beads on the counting of radioactivity. The standard adhere assay involved the adherence of radiolabeled bacteria to 40mg of HA beads. The beads were mixed with ['H]thymidine-labeled bacterial cells and incubated for 60 minutes at room temperature. Unadsorbed cells were removed, the beads with adsorbed cells were dried, and the radioactivity was monitered in a scintillation spectrometer. The 30 seconds sonication of cells in a form of long chains appeared to be adequate for obtaining mostly singlet or doublet cells. Unlike the counting of S. sanguis cell suspension, bacterial cells adhered to HA or saliva-coated HA(SHA) required smaller volume (2.5ml) of scintillaton fluid for better counting. Eighteen percent quenching of counts could be attributed to the beads. Among 3 procedures commonly used to equilibrate the beads for adherence assay, no differences were found in their effectiveness. The HA beads on which the bacteria remained attached in scintillant during the counting were found to be the source of sample self-absorption representing 34.5% of the total radioactivity counts resulting from the beads dissolved in HCl solution.

  • PDF

A Digitally Controlled Three-Phase Cycloconverter Type High Frequency AC Link Inverter Using Space Vector Modulation

  • Sha, Deshang;Qin, Zian;Wu, Dan;Liao, Xiaozhong
    • Journal of Power Electronics
    • /
    • v.11 no.1
    • /
    • pp.28-36
    • /
    • 2011
  • In this paper, a three phase cycloconverter type high frequency AC link inverter is discussed. The configuration consists of a high frequency full-bridge inverter and a high frequency transformer followed by a three phase cycloconverter whose switch is composed of anti-series connected MOSFETs with a common source. A simple digital control strategy based on space vector modulation (SVM) and repetitive control for the cycloconverter is proposed although its input voltage is a high frequency AC pulse. The operation principle of the proposed control strategy is analyzed and the equivalent working modes during one interval are also presented. The effectiveness of the proposed control strategy is verified through Matlab/Simulink simulations and experiments on a 1.45kW prototype.

Writable Cholesteric Liquid Crystal Display and the algorithm used to detect its image

  • Lee, Da-Wei;Shiu, Jyh-Wen;Sha, Yi-An;Chang, Yu-Pei
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.356-359
    • /
    • 2007
  • Writable Cholesteric Liquid Crystal Display and the algorithm used to detect its image were developed. We could use any hard tip, ex: the tip of a forefinger, to directly write an image on the surface of Cholesteric Liquid Crystal Display (CHLCD). By measuring the capacitance of one pixel of test cell (12mm x 15mm/1x1), F-state or P-state could be detected. By measuring the capacitance of one pixel of 4.1" CHLCD (241um x 241um/ 320x320), F-state or Pstate could not be detected, due to the effect of parasitic capacitance. Therefore, high frequency measurement and the algorithm were developed to detect the image on CHLCD.

  • PDF