• Title/Summary/Keyword: SET K-cover

Search Result 214, Processing Time 0.031 seconds

A Multi-agent System to Assess Land-use and Cover Changes Caused by Forest Management Policy Scenarios (다행위자시스템을 이용한 산림정책별 토지이용 변화와 영향 분석)

  • Park, Soojin;An, Yoo Soon;Shin, Yujin;Lee, Sooyoun;Sim, Woojin;Moon, Jiyoon;Jeong, Gwan Young;Kim, Ilkwon;Shin, Hyesop;Huh, Dongsuk;Sung, Joo Han;Park, Chan Ryul
    • Journal of the Korean Geographical Society
    • /
    • v.50 no.3
    • /
    • pp.255-276
    • /
    • 2015
  • This paper presents a multi-agent system model of land-use and cover changes, which is developed and applied to the Gariwang-san and its vicinity, located in Pyeongchang and Jeongseon-gun, Gangwon province, Korea. The Land Use Dynamics Simulator (LUDAS) framework of this study is well suited for representing the spatial heterogeneity and dynamic interactions between human and natural environment, and capturing the impacts of forest-opening policy interventions to future socio-economic and natural environment changes. The model consists of four components: (1) a system of human population, (2) a system of landscape environment, (3) decision-making procedures integrating human(or household), environmental and policy information into forest land-use decisions, and (4) a set of policy scenarios that are related to the forest-opening. The results of model simulation by different combination of various forest management scenarios are assessed by the levels of household income, ecosystem service value and income inequality in the study region. As a result, the optimal scenario of forest-opening policies in the study region is to open the forest to local residential community for the purpose of recreation, considering the distinctive topographical feature. The model developed in this research is expected to contribute to a decision support system for sustainable forest management and various land-use policies in Korea.

  • PDF

The Development of a Real-Time Hand Gestures Recognition System Using Infrared Images (적외선 영상을 이용한 실시간 손동작 인식 장치 개발)

  • Ji, Seong Cheol;Kang, Sun Woo;Kim, Joon Seek;Joo, Hyonam
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.21 no.12
    • /
    • pp.1100-1108
    • /
    • 2015
  • A camera-based real-time hand posture and gesture recognition system is proposed for controlling various devices inside automobiles. It uses an imaging system composed of a camera with a proper filter and an infrared lighting device to acquire images of hand-motion sequences. Several steps of pre-processing algorithms are applied, followed by a background normalization process before segmenting the hand from the background. The hand posture is determined by first separating the fingers from the main body of the hand and then by finding the relative position of the fingers from the center of the hand. The beginning and ending of the hand motion from the sequence of the acquired images are detected using pre-defined motion rules to start the hand gesture recognition. A set of carefully designed features is computed and extracted from the raw sequence and is fed into a decision tree-like decision rule for determining the hand gesture. Many experiments are performed to verify the system. In this paper, we show the performance results from tests on the 550 sequences of hand motion images collected from five different individuals to cover the variations among many users of the system in a real-time environment. Among them, 539 sequences are correctly recognized, showing a recognition rate of 98%.

Bond Characteristics of Ultra High Performance Concrete (초고성능 콘크리트(UHPC)의 부착특성에 관한 연구)

  • Kook, Kyung-Hun;Shin, Hyun-Oh;Kwahk, Im-Jong;Yoon, Young-Soo
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.6
    • /
    • pp.753-760
    • /
    • 2010
  • Ultra high performance concrete (UHPC), is characterized by its high compressive strength and advanced tensile behavior that is much superior to those of conventional concrete. In order to apply this new material in practice, the bond characteristics of UHPC were evaluated in this study. Pull-out tests between UHPC and deformed steel rebar were carried out according to the modified RILEM test method, and were verified by finite element analysis. From the test results showed that UHPC presents 5 to 10 times higher bond strength compared to normal strength concrete, this study suggested remarkably reduced development length and concrete cover comparing to existing specifications. The test results of 700 MPa high strength steel rebar demonstrated the applicability of high strength steel to UHPC. In addition, the transfer length measurements of seven-wire strand in UHPC specimens indicated that the transfer length limit set by the current design code is very conservative for UHPC.

Reynolds and froude number effect on the flow past an interface-piercing circular cylinder

  • Koo, Bonguk;Yang, Jianming;Yeon, Seong Mo;Stern, Frederick
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.6 no.3
    • /
    • pp.529-561
    • /
    • 2014
  • The two-phase turbulent flow past an interface-piercing circular cylinder is studied using a high-fidelity orthogonal curvilinear grid solver with a Lagrangian dynamic subgrid-scale model for large-eddy simulation and a coupled level set and volume of fluid method for air-water interface tracking. The simulations cover the sub-critical and critical and post critical regimes of the Reynolds and sub and super-critical Froude numbers in order to investigate the effect of both dimensionless parameters on the flow. Significant changes in flow features near the air-water interface were observed as the Reynolds number was increased from the sub-critical to the critical regime. The interface makes the separation point near the interface much delayed for all Reynolds numbers. The separation region at intermediate depths is remarkably reduced for the critical Reynolds number regime. The deep flow resembles the single-phase turbulent flow past a circular cylinder, but includes the effect of the free-surface and the limited span length for sub-critical Reynolds numbers. At different Froude numbers, the air-water interface exhibits significantly changed structures, including breaking bow waves with splashes and bubbles at high Froude numbers. Instantaneous and mean flow features such as interface structures, vortex shedding, Reynolds stresses, and vorticity transport are also analyzed. The results are compared with reference experimental data available in the literature. The deep flow is also compared with the single-phase turbulent flow past a circular cylinder in the similar ranges of Reynolds numbers. Discussion is provided concerning the limitations of the current simulations and available experimental data along with future research.

Monthly Heating Energy Needs Analysis According to ISO 13790 and ISO 52016 (ISO 13790과 ISO 52016에 의한 월별 난방에너지 소요량 분석)

  • Zo, Chung-Hoon;Yun, Geun-Young
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.5
    • /
    • pp.11-28
    • /
    • 2019
  • Governments are increasing energy efficiency in buildings through various policies to reduce building energy consumption. In 2002, the European Union adopted a building energy performance guideline to set minimum efficiency standards for residential and commercial buildings. Starting in 2020, all EU member states should ensure that all buildings are Near-Zero Energy Buildings (NZEB). In Korea, the government issued a zero-energy certification system. Since 2020, public buildings are required to cover energy consumption with the energy produced in buildings. As the demand for building energy simulation has increased to increase the energy efficiency of these buildings, the International Standard Organization (ISO) has created a standard for calculating building energy requirements called ISO 13790. This standard was revised to ISO 52016 in 2017. In this research, ISO 13790, which calculates the energy needs of existing buildings, and ISO 52016, which replaces them, are compared and analyzed, and applied to the calculation of heating energy needs of buildings. For models without thermal zoning(Case A), the difference in annual heating energy needs calculated from each criterion is $1.08kWh/m^2$, which is about 2% higher in ISO 52016. In the case of the thermal zoning model(Case B), the difference in annual heating energy needs calculated by each standard was $0.97kWh/m^2$, which was about 2% higher than ISO 52016. The heating energy needs model without thermal zoning has a higher energy needs than the heating energy needs model with thermal zoning. It is about 16% energy at $8.58kWh/m^2$ for ISO 13790 and $8.69kWh/m^2$ for ISO 52016.

Relationship between Environment Factors and Distribution of Pinus densiflora after Fire in Goseong, Gangwon Province, Korea (산불 후 입지에 따른 소나무 분포와 환경 요인 - 강원도 고성군을 중심으로 -)

  • Shin, Moon-Hyun;Lim, Joo-Hoon;Kong, Woo-Suk
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.17 no.2
    • /
    • pp.49-60
    • /
    • 2014
  • This study was conducted to evaluate the effect of forest fire on natural distribution and regeneration of Pinus densiflora Sieb. & Zucc. in Goseong, Gangwon province, Korea. After 13 years of the last forest fire in 2000, five investigation plots ($10m{\times}10m$) in each of rocky land and ridge, the well-known location as a favorite site for natural distribution of P. densiflora, were set to investigate stand characteristic and soil environment including physico-chemical properties and moisture contents of soil. Also, five investigation plots in slope area were set and investigated as well. The concentration of organic matter, total nitrogen, and exchangeable nutrients ($K^+$, $Ca^{2+}$, $Mg^{2+}$) were highest in the slope while the soil in the rocky land showed the lowest concentration of organic matter, total nitrogen, available $P_2O_5$, and exchangeable nutrients ($K^+$, $Na^+$, $Ca^{2+}$, $Mg^{2+}$). The soil in the slope only showed higher concentration of total nitrogen, $K^+$ and $Ca^{2+}$ than the unburned area in Goseong. Mean soil moisture contents in the rocky land (5.77%) were lowest while the slope (15.78%) and the ridge (15.27%) showed almost three times as much than the rocky land. P. densiflora was dominant in the rocky land and Quercus spp. were dominant in the ridge and slope. The average proportion of P. densiflora was highest in rocky land (58.4%, 14.6 trees per plot) followed by the ridge (25.2%, 7.8 trees per plot) and the slope (11.3%, 3.4 trees per plot) while the average height of P. densiflora was highest in slope (277cm) followed by the ridge and the rocky land. The height and crown width of Quercus spp. were higher than P. densiflora in the every plot. The results suggest that P. densiflora may be able to naturally regenerate and survive in the rocky land after the fire while P. densiflora in the ridge and the slope are suppressed by Quercus spp.

Design of Color Matching Filters and Error Analysis in Colorimetric Measurement of LCD Flat Panel Display Using the Filters (등색함수 필터의 설계와 이를 이용한 LCD 평판 디스플레이의 색채 측정에 대한 오차 분석)

  • Jeon, Ji-Ho;Jo, Jae-Heung;Park, Seung-Nam;Park, Chul-Woung;Lee, Dong-Hoon;Jung, Ki-Lyong
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.1
    • /
    • pp.1-7
    • /
    • 2007
  • Filter colorimeters have a set of spectral bands for which spectral responsivity is the same as the color matching function defined by CIE (Commission Internationale de I'Eclairage). We have designed a set of color matching function filters denoted by $\bar{x}-filter,\;\bar{y}-filter,\;and\;\bar{z}-filter$. Because the $\bar{x}-function$ has two transmission bands, two $\bar{x}-filters$ are designed to cover the $\bar{x}-function$. To design the filters, we developed a nonlinear least square fit program which determines the thickness of the color glasses by minimizing its spectral mismatch value ($f{_1}'$) to below 3 %. The design has been validated by fabrication of the $\bar{y}-bar$ filter, of which $f{_1}'$ was measured to be 2.8 %. Considering a LCD flat panel display as a device under test, we have calculated the systematic error of the colorimetric measurement using the designed filters.

Analysis on the Risk-Based Screening Levels Determined by Various Risk Assessment Tools (II): Derivation of Particulate Emission Factor at Former Janghang Smelter Site (다양한 위해성평가 방법에 따라 도출한 토양오염 판정기준의 차이에 관한 연구 (II): (구)장항제련소부지의 기상 및 부지 특성을 반영한 비산계수 결정)

  • Jung, Jae-Woong;Yang, Kyung;Lee, Gwang-Hun;Ryu, Hye-Rim;Nam, Kyoung-Phile
    • Journal of Soil and Groundwater Environment
    • /
    • v.17 no.3
    • /
    • pp.21-31
    • /
    • 2012
  • This paper presents the short-term and long-term measures to determine the fugitive dust concentration in a contaminated site, which is a crucial step for the determination of particulate emission factor (PEF) for risk assessment. As a long-term measure, USEPA method employing Q/C value (inverse of the ratio of the geometric mean air concentration to the emission flux at center of a 0.5-acre square source) seems to be suitable as it reflects regional-specific meteorological conditions. However, it requires nation-wide database collection and interpretation. Use of ASTM method is an alternative as a short-term measure. The method is readily field-applicable as PEF calculation equation is simple and input parameters can be easily derived at the site of interest as well without the nation-wide efforts. Using ASTM method, PEF at the Former Janghang Smelter Site was determined. According to various mode of aggregate size distribution and fractions of vegetative cover, which are the most important factors in PEF calculation, PEF values at the Former Janghang Smelter Site varied greatly. When the mode of aggregate size distribution was set at 0.25 mm, PEF values at the Former Janghang Smelter Site was 5~20 times higher than the default PEF value (i.e., 35 ${\mu}g/m^3$) shown in the current Korean Soil Contamination Risk Assessment Guidance. On contrast, when the mode was set at 2 mm, PEF values at the Former Janghang Smelter Site was 160~640 times lower than the default PEF value in the Korean Guidance.

The Impact of Power Plants on the Environment and Region - Focus on Incheon Area according to the 3rd Electric Support Action Plan - (발전소 증설이 환경, 지역사회 및 경제에 미치는 영향 - 제 3차 전력 수급계획에 의한 인천 지역의 화력발전소 증설을 중심으로 -)

  • Jung, Chang Hoon;Pokarel, Rajib;Lee, Hee Kwan
    • Journal of Environmental Impact Assessment
    • /
    • v.18 no.4
    • /
    • pp.195-208
    • /
    • 2009
  • The power plant is well known to influence air pollution as well as emission of green house gas. Because of increasing demand on electricity, the government set up the electric support action plan every 2 years. In this research, the impacts of power plants on the environment and region was studied. The study was focused on the establishment of power plant in Incheon area based on the 3rd electric support action plan. According to the 3rd electric support action plan, almost 80% of power plant in metropolitan area is planned to be built in Incheon area. The main influences of establishment of power plant are emissions of $SO_x$, $NO_x$ and PM and exceed the allocated local industry emissions, which means the emission allocation of other industry is difficult. In additions, the power plant exhaust $CO_2$ much more than other types of fuel such as waterpower generation, atomic power station. Although several supports are given in local government, these cannot cover the whole cost due to establishment of power plant. Subsequently, this study suggest the additional policy based on local consideration is needed and the current electricity distribution system should be reconsidered fundamentally in the lang term.

A Study on Stereo Matching Algorithm using Disparity Space Image (시차공간영상을 이용한 스테레오 영상 정합에 관한 연구)

  • Lee, Jong-Min;Kim, Dae-Hyun;Choi, Jong-Soo
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.41 no.6
    • /
    • pp.9-18
    • /
    • 2004
  • This paper proposes a new and simple stereo matching algorithm using the disparity space image (DSI) technique. First of all, we detect some salient feature points on each scan-line of the image pair and set the matching area using those points and define a simple cost matrix. And we take advantage of matching by pixel-by-pixel instead of using the matching window. While the pixel-by-pixel method boost up the speed of matching, because of no using neighbor information, the correctness of the matching may not be better. To cover this point, we expand the matching path using character of disparity-space-image for using neighbor information. In addition, we devise the compensated matching module using the volume of the disparity space image in order to improve the accuracy of the match. Consequently, we can reduce mismatches at the disparity discontinuities and can obtain the more detailed and correct disparity map.