• Title/Summary/Keyword: SEOK

Search Result 73,140, Processing Time 0.093 seconds

Characteristics of Particulate Carbon in the Ambient Air in the Korean Peninsula (한반도 권역별 대기 중 입자상 탄소 특성 연구)

  • Lee, Yeong-jae;Park, Mi-kyung;Jung, Sun-a;Kim, Sun-jung;Jo, Mi-ra;Song, In-ho;Lyu, Young-sook;Lim, Yong-jae;Kim, Jung-hoon;Jung, Hae-jin;Lee, Sang-uk;Choi, Won-Jun;Ahn, Joon-young;Lee, Min-hee;Kang, Hyun-jung;Park, Seung-myeong;Seo, Seok-jun;Jung, Dong-hee;Hyun, Joo-kyeong;Park, Jong-sung;Hwang, Tae-kyung;Hong, You-deog;Hong, Ji-hyung;Shin, Hye-jung
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.31 no.4
    • /
    • pp.330-344
    • /
    • 2015
  • Semi-continuous measurements of $PM_{2.5}$ mass, organic and elemental carbon were made for the period of January to October 2014, at six national air monitoring stations in Korea. OC and EC concentrations showed a clear seasonal variation with the highest in winter (January) and the lowest in summer (August). In winter, the high carbonaceous concentrations were likely influenced by increased fuel combustion from residential heating. OC and EC concentrations varied by monitoring stations with 5.9 and $1.7{\mu}g/m^3$ in Joongbu area, 4.2 and $1.2{\mu}g/m^3$ in Honam area, 4.0 and $1.3{\mu}g/m^3$ in Yeongnam area, 3.7 and $1.6{\mu}g/m^3$ in Seoul Metropolitan area, 3.0 and $0.8{\mu}g/m^3$ in Jeju Island, 2.9 and $0.7{\mu}g/m^3$ in Baengnyeong Island respectively. The concentrations of OC and EC comprised 9.6~ 15.5% and 2.4~ 4.7% of $PM_{2.5}$. Urban Joongbu area located adjacent to the intersection of several main roads showed the highest carbon concentration among six national air monitoring station. On the other hand, background Baengnyeong Island showed the lowest carbon concentration and the highest OC/EC ratio (4.5). During the haze episode, OC and EC were enhanced with increase in $PM_{2.5}$ about 1.3~ 3 and 1.3~ 4.0 times respectively. The concentrations of OC, EC in the Asian dust case are about 1~ 2.4 times greater than in the nondust case. The origins of air mass pathways arriving at Seoul, using the backward trajectory analysis, can be mostly classified into 6 groups (Sector I Northern Korea including the sea of Okhotsk, Sector II Northern China including Mongolia, Sector III Southern China, Sector IV South Pacific area, Sector V Japan, Sector VI Southern Korea area). When an air mass originating from northern China and Mongolia, the OC concentrations were the most elevated, with a higher OC/EC ratio (2.4~ 3.3), and accounting for 17% of $PM_{2.5}$ mass on average.

Plasma G-CSF and GM-CSF Concentrations and Expression of their Receptors on the Granulocyte in Children with Leukocytosis (백혈구 증가증 환아의 혈장내 G-CSF와 GM-CSF의 농도 및 과립구에서의 이들 수용체의 발현)

  • Choi, Won Seok;Ryu, Kyung Hwan;Kim, You Jeong;Kim, So Young;Kim, Hyun Hee;Lee, Wonbae
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.3
    • /
    • pp.271-276
    • /
    • 2003
  • Purpose : Granulocyte-colony stimulating factor(G-CSF) and granulocyte macrophage-colony stimulating factor(GM-CSF) are principal cytokines in granulopoiesis and their physiologic effects are mediated through binding to specific cell surface receptors. Although it is known that the level of serum G-CSF and GM-CSF, and presentation of the receptors are increased in infectious diseases, there have been no studies to find the correlation between the granulopoiesis and leukocytosis. This study was designed to measure G-CSF and GM-CSF in leukocytosis and in control and to demonstrate the possible pathogenesis of granulopoiesis in leukocytosis using quantitative analysis of G-CSF, GM-CSF and their CSFr. Methods : The plasma levels of G-CSF, GM-CSF of 13 children without leukocytosis and 14 children with leukocytosis were measured. Counts of cell surface G-CSFr and GM-CSFr were measured by combining anti G-CSFr and anti GM-CSFr monoclonal antibodies to their respective receptors by using quantitative flow cytometric assay. Results : There was no significant difference betweeen the plasma concentration of G-CSF and GM-CSF in acute leukocytosis and in the control group. However, levels of G-CSFr in acute leukocytosis decreased significantly compared to the control(P=0.012) and the levels of GM-CSFr in both groups revealed no significant difference. Conclusion : Increase in the number of leukocyte in leukocytosis was mediated by increasing the number of neutrophil, and increased plasma concentration of G-CSF may be the cause of neutrophilia. But GM-CSF did not have any influence on leukocytosis.

Factors Related to Waiting and Staying Time for Patient Care in Emergency Care Center (응급의료센터 내원환자 진료시 소요시간과 관련된 요인)

  • Han, Nam Sook;Park, Jae Yong;Lee, Sam Beom;Do, Byung Soo;Kim, Seok Beom
    • Quality Improvement in Health Care
    • /
    • v.7 no.2
    • /
    • pp.138-155
    • /
    • 2000
  • Background: Factors related to waiting and staying time for patient care in emergency care center (ECC) were examined during 1 month from Apr. 1 to Apr. 30, 1997 at an ECC of Yeungnam university hospital in Taegu metropolitan city, to obtain the baseline data on the strategy of effective management of emergency patients. Method: The study subjects consisted of the 1,742 patients who visited at ECC and the data were obtained from the medical records of ECC and direct surveys. Results: The mean interval between ECC admission time and initial care time by each ECC duty residents was 83.1 minutes for male patients and 84.9 minutes for female patients, and mean ECC staying time (time interval between admission and final disposition from ECC) was 718.0 minutes in men and 670.5 minutes in women. As the results, the mean staying time in ECC was higher in older age, and especially the both of initial care time and staying time were highest in patients of medical aid, and shortest in patients of worker's accident compensation insurance. The on admission or not, previously endotracheal-intubation state of patient. The ECC staying ti initial care time was much more delayed in patients of not having previous medical records and the ECC staying time was higher in referred patients from out-patient department, in transferred patients from the other hospitals and patients having previous records, and in patients partly used the order-communicating system. The factors associated with the initial care time were the numbers of ECC patients and the existence of any true emergent patients, being cardiopulmonary resuscitation (CPR) statusme was much more longer in patients of drug intoxication, in CPR patients, in medical department patients, in transfused patients and in patients related to 3 or more departments. And according to the numbers of duty internships, the ECC staying time for four internships was more longer than for five internships and after admission ordering was done, also-more longer in status being of no available beds. As above mentioned results, the factors for the ECC staying time were thought to be statistically significant (P<0.01) according to the patient's age and the laboratory orders and the X-ray films checked. And also the factor for the ECC staying time were thought to be statistically significant (P<0.01) according to the status being of no available beds, the laboratory orders and/or the special laboratory orders, the X-ray films checked, final disposing department, transferred to other hospital or not, home medication or not, admission or not, the grades of beds, the year grades of residents, the causes of ECC visit, the being CPR status on admission or not, the surgical operation or not, being known personells in our hospital. Conclution: Authors concluded that the relieving method of long-staying time in ECC was being establishing the legally proved apparatus which could differentiate the true emergency or non-emergency patients, and that the methods of shortening ECC staying time were doing definitely necessary laboratory orders and managing beds more flexibly to admit for ECC patients and finally this methods were thought to be a method of unloading for ECC personnels and improving the quality of care in emergency patients.

  • PDF

The study of thermal change by chemoport in radiofrequency hyperthermia (고주파 온열치료시 케모포트의 열적 변화 연구)

  • Lee, seung hoon;Lee, sun young;Gim, yang soo;Kwak, Keun tak;Yang, myung sik;Cha, seok yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.97-106
    • /
    • 2015
  • Purpose : This study evaluate the thermal changes caused by use of the chemoport for drug administration and blood sampling during radiofrequency hyperthermia. Materials and Methods : 20cm size of the electrode radio frequency hyperthermia (EHY-2000, Oncotherm KFT, Hungary) was used. The materials of the chemoport in our hospital from currently being used therapy are plastics, metal-containing epoxy and titanium that were made of the diameter 20 cm, height 20 cm insertion of the self-made cylindrical Agar phantom to measure the temperature. Thermoscope(TM-100, Oncotherm Kft, Hungary) and Sim4Life (Ver2.0, Zurich, Switzerland) was compared to the actual measured temperature. Each of the electrode measurement position is the central axis and the central axis side 1.5 cm, 0 cm(surface), 0.5 cm, 1.8 cm, 2.8 cm in depth was respectively measured. The measured temperature is $24.5{\sim}25.5^{\circ}C$, humidity is 30% ~ 32%. In five-minute intervals to measure the output power of 100W, 60 min. Results : In the electrode central axis 2.8 cm depth, the maximum temperature of the case with the unused of the chemoport, plastic, epoxy and titanium were respectively $39.51^{\circ}C$, $39.11^{\circ}C$, $38.81^{\circ}C$, $40.64^{\circ}C$, simulated experimental data were $42.20^{\circ}C$, $41.50^{\circ}C$, $40.70^{\circ}C$, $42.50^{\circ}C$. And in the central axis electrode side 1.5 cm depth 2.8 cm, mesured data were $39.37^{\circ}C$, $39.32^{\circ}C$, $39.20^{\circ}C$, $39.46^{\circ}C$, the simulated experimental data were $42.00^{\circ}C$, $41.80^{\circ}C$, $41.20^{\circ}C$, $42.30^{\circ}C$. Conclusion : The thermal variations were caused by radiofrequency electromagnetic field surrounding the chemoport showed lower than in the case of unused in non-conductive plastic material and epoxy material, the titanum chemoport that made of conductor materials showed a slight differences. This is due to the metal contents in the chemoport and the geometry of the chemoport. And because it uses a low radio frequency bandwidth of the used equipment. That is, although use of the chemoport in this study do not significantly affect the surrounding tissue. That is, because the thermal change is insignificant, it is suggested that the hazard of the chemoport used in this study doesn't need to be considered.

  • PDF

Evaluating efficiency of Split VMAT plan for prostate cancer radiotherapy involving pelvic lymph nodes (골반 림프선을 포함한 전립선암 치료 시 Split VMAT plan의 유용성 평가)

  • Mun, Jun Ki;Son, Sang Jun;Kim, Dae Ho;Seo, Seok Jin
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.145-156
    • /
    • 2015
  • Purpose : The purpose of this study is to evaluate the efficiency of Split VMAT planning(Contouring rectum divided into an upper and a lower for reduce rectum dose) compare to Conventional VMAT planning(Contouring whole rectum) for prostate cancer radiotherapy involving pelvic lymph nodes. Materials and Methods : A total of 9 cases were enrolled. Each case received radiotherapy with Split VMAT planning to the prostate involving pelvic lymph nodes. Treatment was delivered using TrueBeam STX(Varian Medical Systems, USA) and planned on Eclipse(Ver. 10.0.42, Varian, USA), PRO3(Progressive Resolution Optimizer 10.0.28), AAA(Anisotropic Analytic Algorithm Ver. 10.0.28). Lower rectum contour was defined as starting 1cm superior and ending 1cm inferior to the prostate PTV, upper rectum is a part, except lower rectum from the whole rectum. Split VMAT plan parameters consisted of 10MV coplanar $360^{\circ}$ arcs. Each arc had $30^{\circ}$ and $30^{\circ}$ collimator angle, respectively. An SIB(Simultaneous Integrated Boost) treatment prescription was employed delivering 50.4Gy to pelvic lymph nodes and 63~70Gy to the prostate in 28 fractions. $D_{mean}$ of whole rectum on Split VMAT plan was applied for DVC(Dose Volume Constraint) of the whole rectum for Conventional VMAT plan. In addition, all parameters were set to be the same of existing treatment plans. To minimize the dose difference that shows up randomly on optimizing, all plans were optimized and calculated twice respectively using a 0.2cm grid. All plans were normalized to the prostate $PTV_{100%}$ = 90% or 95%. A comparison of $D_{mean}$ of whole rectum, upperr ectum, lower rectum, and bladder, $V_{50%}$ of upper rectum, total MU and H.I.(Homogeneity Index) and C.I.(Conformity Index) of the PTV was used for technique evaluation. All Split VMAT plans were verified by gamma test with portal dosimetry using EPID. Results : Using DVH analysis, a difference between the Conventional and the Split VMAT plans was demonstrated. The Split VMAT plan demonstrated better in the $D_{mean}$ of whole rectum, Up to 134.4 cGy, at least 43.5 cGy, the average difference was 75.6 cGy and in the $D_{mean}$ of upper rectum, Up to 1113.5 cGy, at least 87.2 cGy, the average difference was 550.5 cGy and in the $D_{mean}$ of lower rectum, Up to 100.5 cGy, at least -34.6 cGy, the average difference was 34.3 cGy and in the $D_{mean}$ of bladder, Up to 271 cGy, at least -55.5 cGy, the average difference was 117.8 cGy and in $V_{50%}$ of upper rectum, Up to 63.4%, at least 3.2%, the average difference was 23.2%. There was no significant difference on H.I., and C.I. of the PTV among two plans. The Split VMAT plan is average 77 MU more than another. All IMRT verification gamma test results for the Split VMAT plan passed over 90.0% at 2 mm / 2%. Conclusion : As a result, the Split VMAT plan appeared to be more favorable in most cases than the Conventional VMAT plan for prostate cancer radiotherapy involving pelvic lymph nodes. By using the split VMAT planning technique it was possible to reduce the upper rectum dose, thus reducing whole rectal dose when compared to conventional VMAT planning. Also using the split VMAT planning technique increase the treatment efficiency.

  • PDF

A study of usefulness for the plan based on only MRI using ViewRay MRIdian system (ViewRay MRIdian System을 이용한 MRI only based plan의 유용성 고찰)

  • Jeon, Chang Woo;Lee, Ho Jin;An, Beom Seok;Kim, Chan young;Lee, Je hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.131-143
    • /
    • 2015
  • Purpose : By comparing a CT fusion plan based on MRI with a plan based on only MRI without CT, we intended to study usefulness of a plan based on only MRI. And furthermore, we intended to realize a realtime MR-IGRT by MRI image without CT scan during the course of simulation, treatment planning, and radiation treatment. Materials and Methods : BBB CT (Brilliance Big Bore CT, 16slice, Philips), Viewray MRIdian system (Viewray, USA) were used for CT & MR simulation and Treatment plan of 11 patients (1 Head and Neck, 5 Breast, 1 Lung, 3 Liver, 1 Prostate). When scanning for treatment, Free Breathing was enacted for Head&Neck, Breast, Prostate and Inhalation Breathing Holding for Lung and Liver. Considering the difference of size between CT and Viewray, the patient's position and devices were in the same condition. Using Viewray MRIdian system, two treatment plans were established. The one was CT fusion treatment plan based on MR image. Another was MR treatment plan including electron density that [ICRU 46] recommend for Lung, Air and Bone. For Head&Neck, Breast and Prostate, IMRT was established and for Lung and Liver, Gating treatment plan was established. PTV's Homogeneity Index(HI) and Conformity Index(CI) were use to estimate the treatment plan. And DVH and dose difference of each PTV and OAR were compared to estimate the treatment plan. Results : Between the two treatment plan, each difference of PTV's HI value is 0.089% (Head&Neck), 0.26% (Breast), 0.67% (Lung), 0.2% (Liver), 0.4% (Prostate) and in case of CI, 0.043% (Head&Neck), 0.84% (Breast), 0.68% (Lung), 0.46% (Liver), 0.3% (Prostate). As showed above, it is on Head&Neck that HI and CI's difference value is smallest. Each difference of average dose on PTV is 0.07 Gy (Head&Neck), 0.29 Gy (Breast), 0.18 Gy (Lung), 0.3 Gy (Liver), 0.18 Gy (Prostate). And by percentage, it is 0.06% (Head&Neck), 0.7% (Breast), 0.29% (Lung), 0.69% (Liver), 0.44% (Prostate). Likewise, All is under 1%. In Head&Neck, average dose difference of each OAR is 0.01~0.12 Gy, 0.04~0.06 Gy in Breast, 0.01~0.21 Gy in Lung, 0.06~0.27 Gy in Liver and 0.02~0.23 Gy in Prostate. Conclusion : PTV's HI, CI dose difference on the Treatment plan using MR image is under 1% and OAR's dose difference is maximum 0.89 Gy as heterogeneous tissue increases when comparing with that fused CT image. Besides, It characterizes excellent contrast in soft tissue. So, radiation therapy using only MR image without CT scan is useful in the part like Head&Neck, partial breast and prostate cancer which has a little difference of heterogeneity.

  • PDF

Quality of Life and Its Related Factors of Radiation Therapy Cancer Patients (방사선 치료를 받은 암환자의 삶의 질과 관련요인)

  • Shin, Ryung-Mi;Jung, Won-Seok;Oh, Byeong-Cheon;Jo, Jun-Young;Kim, Gi-Chul;Choi, Tae-Gyu;Lee, Sok-Goo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.1
    • /
    • pp.21-29
    • /
    • 2011
  • Purpose: The purpose of this master's thesis is to utilize basic data in order to improve the quality of life of cancer patients who received radiation therapy after analysing related factors that influence patient's quality of life and obtaining information about physical, mental problems of patients. Materials and Methods: By using a structured questionnaire about various characteristics and forms of support, I carried out a survey targeting 107 patients that experienced radiation therapy at a university hospital in the Daejeon metropolitan area from July 15 to August 15, 2010 and analysed the factors influencing quality of life. Results: In case of pain due to disease, 65.15 and painless 81.87 showed a high grade quality of life. As body weight decreases, the quality of life become lower. When the grade of quality of life according to economic characteristics was compared, all items except treatment period showed a difference (P=0.000). When the score of social support, family support, medical support and self-esteem was low, the mark of quality of life showed respectively 61.71, 68.77, 71.31, and 69.39 on the basis of 128 points. When the score of support form was high, the mark of quality of life showed 90.47, 83.29, 90.40, and 90.36 (P<0.05). When analyzing the correlation between social support, family support, medical support and self-esteem and the degree of quality of life, social support was 0.768, family support 0.596, medical support 0.434, self-esteem 0.516. They indicated the correlation of meaningful quantity statistically (P<0.01). The factors that improved the quality of life were married state, having a job and painless status. As monthly income increases, the quality of life was also much improved (P<0.05). Among the factors related to quality of life, social support and medical support and higher self-esteem scores of the quality of life score increased 0.979 point, 0.508 points and 1.667 point, respectively. Conclusion: In conclusion, the quality of life of cancer patients that received radiation treatment is related to social support, medical support and self esteem. Self-esteem is an important factor that influenced quality of life, so if government offers works that doesn't affect patient's health, they are a useful method that maximize self-esteem and lessen their financial burden at the same time. Along with these policies, the developments of the attention of medical and the program for cancer patient's family are needed for the purpose of improving quality of life of cancer patients. Lastly, medical team, patients and family have to cooperate in harmony to overcome difficulties of cancer patients.

  • PDF

Studios on Lipids in Fresh-Water Fishes 5. Distribution of Lipid Components in Various Tissues of Carp, Cyprynus carpio (담수어의 지질에 관한 연구 5. 잉어(Cyprynus carpio)의 부위별 지질성분의 분포)

  • CHOI Jin-Ho;RO Jae-Il;BYUN Dae-Seok;PYEUN Jae-Hyeung
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.18 no.2
    • /
    • pp.149-156
    • /
    • 1985
  • Distribution of lipid components in the tissue of meat, skin and viscera from carp(Cyprynus carpio) was analyzed using the techniques of column chromatography, thin layer chromatography and gas liquid chromatography according to the previous report(Choi, et al., 1984). Lipid content was varied by the portion such as $3.88\%$ in meat (free lipid, $2.47\%$ ; bound lipid, $1.41\%$), $8.02\%$ in skin(free lipid, $5.65\%$ ; bound lipid, $2.37\%$) and $6.18\%$ in viscera (free lipid, $3.54\%$ ; bound lipid, $2.64\%$). In the all portions of the body, free lipid was composed of $68\%\;to\;92\%$ in neutral lipid, $3\%\;to\;6\%$ in glycolipid and $4\%\;to\;18\%$ in phospholipid whereas bound lipid was composed of $8\%\;to\;20\%$ in neutral lipid, $2\%\;to\;7\%$ in glycolipid and $47\%\;to\;62\%$ in phospholipid. The free lipids of the tissues on the each portion were mostly represented by triglycerides and some diglycerides, but free lipids in viscera contained considerable amounts of free fatty acids. The bound lipids, on the other hand, commonly comprised appreciable amounts of esterified sterol and hydrocarbon, and triglycerides. The phospholipid was mainly consisted of phosphatidyl choline, phosphatidyl ethanolamine and phosphatidyl serine in the both free and bound lipids, and much more phosphatidyl choline in the bound lipid. The predominant fatty acids of free and bound lipids were $C_{16:0},\;C_{18:0},\;C_{20:4},\;C_{22:6}\;and\;C_{18:2}$ acids in polar lipids, and $C_{16:0},\;C_{16:1},\;C_{18:0},\;C_{18:1}\;and\;C_{18:2}$ acids in non-polar lipids, whereas those of neutral lipids were $C_{14:0}(2.54{\sim}6.98\%),\;C_{16:0}(11.20{\sim}21.13\%)$ and $C_{18:0}(1.58{\sim}12.76\%)$ of saturated acids, $C_{16:1}(7.06{\sim}20.70\%),\;C_{18:1}(21.68{\sim}30.50\%)$ and $C_{20:1}(1.76{\sim}6.27\%)$ of monoenoic acids, and $C_{18:2}(4.50{\sim}6.89\%),\;C_{20:4}(1.52{\sim}4.29\%)$ and $C_{22:6}(0.73{\sim}6.62\%)$, respectively. In conclusion, the fatty acid compositions revealed apparent differences between the free lipid and bound lipids in the tissues of body.

  • PDF

The Gradient Variation of Thermal Environments on the Park Woodland Edge in Summer - A Study of Hadongsongrim and Hamyangsangrim - (여름철 공원 수림지 가장자리의 온열환경 기울기 변화 - 하동송림과 함양상림을 대상으로 -)

  • Ryu, Nam-Hyong;Lee, Chun-Seok
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.43 no.6
    • /
    • pp.73-85
    • /
    • 2015
  • This study investigated the extent and magnitude of the woodland edge effects on users' thermal environments according to distance from woodland border. A series of experiments to measure air temperature, relative humidity, wind velocity, MRT and UTCI were conducted over six days between July 31 and August 5, 2015, which corresponded with extremely hot weather, at the south-facing edge of Hadongsongrim(pure Pinus densiflora stands, tree age: $100{\pm}33yr$, tree height: $12.8{\pm}2.7m$, canopy closure: 75%, N $35^{\circ}03^{\prime}34.7^{{\prime}{\prime}}$, E $127^{\circ}44^{\prime}43.3^{{\prime}{\prime}}$, elevation 7~10m) and east-facing edge of Hamyangsangrim (Quercus serrata-Carpinus tschonoskii community, tree age: 102~125yr/58~123yr, tree height: tree layer $18.6{\pm}2.3m/subtree$ layer $5.9{\pm}3.2m/shrub$ layer $0.5{\pm}0.5m$, herbaceous layer coverage ratio 60%, canopy closure: 96%, N $35^{\circ}31^{\prime}28.1^{{\prime}{\prime}}$, E $127^{\circ}43^{\prime}09.8^{{\prime}{\prime}}$, elevation 170~180m) in rural villages of Hadong and Hamyang, Korea. The minus result value of depth means woodland's outside. The depth of edge influence(DEI) on the maximum air temperature, minimum relative humidity and wind speed at maximum air temperature time during the daytime(10:00~17:00) were detected to be $12.7{\pm}4.9$, $15.8{\pm}9.8$ and $23.8{\pm}26.2m$, respectively, in the mature evergreen conifer woodland of Hadongsongrim. These were detected to be $3.7{\pm}2.2$, $4.9{\pm}4.4$ and $2.6{\pm}7.8m$, respectively, in the deciduous broadleaf woodland of Hamyansangrim. The DEI on the maximum 10 minutes average MRT, UTCI from the three-dimensional environment absorbed by the human-biometeorological reference person during the daytime(10:00~17:00) were detected to be $7.1{\pm}1.7$ and $4.3{\pm}4.6m$, respectively, in the relatively sparse woodland of Hadongsongrim. These were detected to be $5.8{\pm}4.9$ and $3.5{\pm}4.1m$, respectively, in the dense and closed woodland of Hadongsongrim. Edge effects on the thermal environments of air temperature, relative humidity, wind speed, MRT and UTCI in the sparse woodland of Hadongsongrim were less pronounced than those recorded in densed and closed woodland of Hamyansangrim. The gradient variation was less steep for maximum 10 minutes average UTCI with at least $4.3{\pm}4.6m$(Hadongsongrim) and $3.5{\pm}4.1m$(Hamyansangrim) being required to stabilize the UTCI at mature woodlands. Therefore it is suggested that the woodlands buffer widths based on the UTCI values should be 3.5~7.6 m(Hamyansangrim) and 4.3~8.9(Hadongsongrim) m on each side of mature woodlands for users' thermal comfort environments. The woodland edge structure should be multi-layered canopies and closed edge for the buffer effect of woodland edge on woodland users' thermal comfort.

The Influence of Ventilation and Shade on the Mean Radiant Temperature of Summer Outdoor (통풍과 차양이 하절기 옥외공간의 평균복사온도에 미치는 영향)

  • Lee, Chun-Seok;Ryu, Nam-Hyung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.5
    • /
    • pp.100-108
    • /
    • 2012
  • The purpose of the study was to evaluate the influence of shading and ventilation on Mean Radiant Temperature(MRT) of the outdoor space at a summer outdoor. The Wind Speed(WS), Air Temperature(AT) and Globe Temperature(GT) were recorded every minute from $1^{st}$ of May to the $30^{th}$ of September 2011 at a height of 1.2m above in four experimental plots with different shading and ventilating conditions, with a measuring system consisting of a vane type anemometer(Barini Design's BDTH), Resistance Temperature Detector(RTD, Pt-100), standard black globe(${\O}$ 150mm) and data acquisition systems(National Instrument's Labview and Compfile Techs' Moacon). To implement four different ventilating and shading conditions, three hexahedral steel frames, and one natural plot were established in the open grass field. Two of the steel frames had a dimension of $3m(W){\times}3m(L){\times}1.5m(H)$ and every vertical side covered with transparent polyethylene film to prevent lateral ventilation(Ventilation Blocking Plot: VP), and an additional shading curtain was applied on the top side of a frame(Shading and Ventilation Blocking Plot: SVP). The third was $1.5m(W){\times}1.5m(L){\times}1.5m(H)$, only the top side of which was covered by the shading curtain without the lateral film(Shading Plot: SP). The last plot was natural condition without any kind of shading and wind blocking material(Natural Open Plot: NP). Based on the 13,262 records of 44 sunny days, the time serial difference of AT and GT for 24 hour were analyzed and compared, and statistical analysis was done based on the 7,172 records of daytime period from 7 A.M. to 8 P.M., while the relation between the MRT and solar radiation and wind speed was analyzed based on the records of the hottest period from 11 A.M. to 4 P.M.. The major findings were as follows: 1. The peak AT was $40.8^{\circ}C$ at VP and $35.6^{\circ}C$ at SP showing the difference about $5^{\circ}C$, but the difference of average AT was very small within${\pm}1^{\circ}C$. 2. The difference of the peak GT was $12^{\circ}C$ showing $52.5^{\circ}C$ at VP and $40.6^{\circ}C$ at SP, while the gap of average GT between the two plots was $6^{\circ}C$. Comparing all four plots including NP and SVP, it can be said that the shading decrease $6^{\circ}C$ GT while the wind blocking increase $3^{\circ}C$ GT. 3. According to the calculated MRT, the shading has a cooling effect in reducing a maximum of $13^{\circ}C$ and average $9^{\circ}C$ MRT, while the wind blocking has heating effect of increasing average $3^{\circ}C$ MRT. In other words, the MRT of the shaded area with natural ventilation could be cooler than the wind blocking the sunny site to about $16^{\circ}C$ MRT maximum. 4. The regression and correlation tests showed that the shading is more important than the ventilation in reducing the MRT, while both of them do an important role in improving the outdoor thermal comfort. In summary, the results of this study showed that the shade is the first and the ventilation is the second important factor in terms of improving outdoor thermal comfort in summer daylight hours. Therefore, it can be apparently said that the more shade by the forest, shading trees etc., the more effective in conditioning the microclimate of an outdoor space reducing the useless or even harmful heat energy for human activities. Furthermore, the delicately designed wind corridor or outdoor ventilation system can improve even the thermal environment of urban area.