• 제목/요약/키워드: SECM

검색결과 13건 처리시간 0.017초

Frequency-Distance Responses in SECM-EQCM: A Novel Method for Calibration of the Tip-Sample Distance$\S$

  • 신명선;전일철
    • Bulletin of the Korean Chemical Society
    • /
    • 제19권11호
    • /
    • pp.1227-1232
    • /
    • 1998
  • The frequency response on the tip-sample distance in scanning electrochemical microscopy (SECM) that is combined with an electrochemical quartz crystal microbalance (EQCM) is described. The oscillation frequency of the EQCM increases rapidly when the SECM tip is very close to the substrate electrode surface. This frequency increase is reproducible regardless of the current feedback in SECM, which is attributed to the stress caused by the tip pressing the quartz crystal. It is useful to calibrate the tip-sample distance with respect to the frequency change when a combined system of SECM and EQCM (SECM-EQCM) is used. This method could be applied to several cases such as rigid metal electrode and non-conducting or partially conducting polymer coating prepared on the quartz crystal regardless of the feedback current.

Applications of Scanning Electrochemical Microscopy (SECM) Coupled to Atomic Force Microscopy with Sub-Micrometer Spatial Resolution to the Development and Discovery of Electrocatalysts

  • Park, Hyun S.;Jang, Jong Hyun
    • Journal of Electrochemical Science and Technology
    • /
    • 제7권4호
    • /
    • pp.316-326
    • /
    • 2016
  • Development and discovery of efficient, cost-effective, and robust electrocatalysts are imperative for practical and widespread implementation of water electrolysis and fuel cell techniques in the anticipated hydrogen economy. The electrochemical reactions involved in water electrolysis, i.e., hydrogen and oxygen evolution reactions, are complex inner-sphere reactions with slow multi-electron transfer kinetics. To develop active electrocatalysts for water electrolysis, the physicochemical properties of the electrode surfaces in electrolyte solutions should be investigated and understood in detail. When electrocatalysis is conducted using nanoparticles with large surface areas and active surface states, analytical techniques with sub-nanometer resolution are required, along with material development. Scanning electrochemical microscopy (SECM) is an electrochemical technique for studying the surface reactions and properties of various types of electrodes using a very small tip electrode. Recently, the morphological and chemical characteristics of single nanoparticles and bio-enzymes for catalytic reactions were studied with nanometer resolution by combining SECM with atomic force microscopy (AFM). Herein, SECM techniques are briefly reviewed, including the AFM-SECM technique, to facilitate further development and discovery of highly active, cost-effective, and robust electrode materials for efficient electrolysis and photolysis.

Use of Local Electrochemical Methods (SECM, EC-STM) and AFM to Differentiate Microstructural Effects (EBSD) on Very Pure Copper

  • Martinez-Lombardia, Esther;Lapeire, Linsey;Maurice, Vincent;De Graeve, Iris;Klein, Lorena;Marcus, Philippe;Verbeken, Kim;Kestens, Leo;Gonzalez-Garcia, Yaiza;Mol, Arjan;Terryn, Herman
    • Corrosion Science and Technology
    • /
    • 제16권1호
    • /
    • pp.1-7
    • /
    • 2017
  • When aiming for an increased and more sustainable use of metals a thorough knowledge of the corrosion phenomenon as function of the local metal microstructure is of crucial importance. In this work, we summarize the information presented in our previous publications[1-3] and present an overview of the different local (electrochemical) techniques that have been proven to be effective in studying the relation between different microstructural variables and their different electrochemical behavior. Atomic force microscopy (AFM)[1], scanning electrochemical microscopy (SECM)[2], and electrochemical scanning tunneling microscopy (EC-STM)[3] were used in combination with electron backscatter diffraction (EBSD). Consequently, correlations could be identified between the grain orientation and grain boundary characteristics, on the one hand, and the electrochemical behavior on the other hand. The grain orientation itself has an influence on the corrosion, and the orientation of the neighboring grains also seems to play a decisive role in the dissolution rate. With respect to intergranular corrosion, only coherent twin boundaries seem to be resistant.

Applications of Scanning Electrochemical Microscopy

  • Bard, Allen J.;Fan, Fu-Ren F.
    • 분석과학
    • /
    • 제8권4호
    • /
    • pp.1069-1074
    • /
    • 1995
  • The application of scanning electrochemical microscopy to the imaging of surfaces in water and air and to the study of the electrochemistry of single molecules is discussed.

  • PDF

RF magnetron 스파터링법으로 제작한 TiNx 박막의 면저항분석 (Sheet Reisistance Analysis of TiNx Thin Film by RF Magnetron Sputtering)

  • 박문찬;오정홍;김남영;황보창권
    • 한국안광학회지
    • /
    • 제4권1호
    • /
    • pp.21-25
    • /
    • 1999
  • RF(radio-frequency) magnetron 스퍼터링 장치에 질소가스와 아르곤가스를 동시에 주입하면서 Ti 타켓을 스퍼터링하여 TiN, 박막을 유리기판위에 제작하였다. 박막제작시 RF power supply 출력은 240W로, 증착기 내부의 온도는 $200^{\circ}C$를 유지하였다. TiN, 박막은 알곤 가스를 20sccm으로 고정시킨 상태에서 질소를 3sccm부터 9secm까지 변화시켜가며 증착시켰다. 이때 박막의 면저항과 화학적 조성과의 관계를 분석하기 위하여 XPS depth profiling과 4점 탐침법을 사용하였다.

  • PDF

Scanning Electrochemical Microscopy를 이용한 한우 체내 수정란의 호흡률 조사 (Respiration Rates of Individual Bovine In Vivo-Produced Embryos Measured with a Novel, Scanning Electrochemical Microscopy)

  • 김현;복난희;김성우;도윤정;김민규;조상래;성환후;김동훈;고응규
    • 한국수정란이식학회지
    • /
    • 제29권1호
    • /
    • pp.91-99
    • /
    • 2014
  • Oxygen consumption is a useful parameter for evaluating mammalian embryo quality, since individual bovine embryos was noninvasively quantified by scanning electrochemical microscopy (SECM). Recently, several approaches have been used to measure the oxygen consumption rates of individual embryos, but relationship between oxygen consumption and pregnancy rates of Hanwoo following embryo transfer has not yet been reported. In this study, we measured to investigate the correlation between oxygen consumption rate and pregnancy rates of Hanwoo embryo using a SECM. In addition to, the expression of pluripotent gene and anti-oxidant enzyme was determined using real-time PCR by extracting RNA according to the oxygen consumption of in vivo embryo. First, we found that the oxygen consumption significantly increased in blastocyst-stage embryos (blastocyst) compared to early blastocyst stage embryos, indicating that oxygen consumption reflects the embryo quality (Grade I). Oxygen consumption of blastocyst was measured using a SECM and total cell number of in vitro blastocyst was enumerated by counting cells stained by propidium iodide. The oxygen consumption or GI blastocysts were significantly higher than those of GII blastocysts ($10.2{\times}10^{15}/mols^{-1}$ versus $6.4{\times}10^{15}/mols^{-1}$, p<0.05). Total cell numbers of in vitro blastocysts were 74.8, 90.7 and 110.2 in the oxygen consumption of below 10.0, 10.0~12.0 and over $12.0{\sim}10^{15}/mols^{-1}$, respectively. Pregnant rate in recipient cow was 0, 60 and 80% in the transplantation of embryo with the oxygen consumption of below 10.0, 10.0~12.0 and over $12.0{\times}10^{15}/mols^{-1}$, respectively. GPX1 and SOD1 were significantly increased in over -10.0 group than below 10.0 groups but in catalase gene, there was no significant difference. On the other hand, In OCT-4 and Sox2, pluripotent gene, there was a significant difference (p<0.05) between the below-10.0 ($0.98{\pm}0.1$) and over 10.0 ($1.79{\pm}0.2$). In conclusion, these results suggest that measurement of oxygen consumption maybe help increase the pregnant rate of Hanwoo embryos.

Scanning Ion Conductivity Microscopy의 Approach Curve에 대한 측정 및 계산을 통한 Current Squeezing 효과의 고찰 (An Investigation of the Current Squeezing Effect through Measurement and Calculation of the Approach Curve in Scanning Ion Conductivity Microscopy)

  • 김영서;조영준;신한균;박현;김정한;이효종
    • 마이크로전자및패키징학회지
    • /
    • 제31권2호
    • /
    • pp.54-62
    • /
    • 2024
  • SICM (scanning ion conductivity microscopy)은 nanopipette이 시료에 접근하게 되면서 tip에 인가되는 전류값의 변화가 발생하는데, 이를 이용하여 시료의 표면 형상을 측정하는 분석기술이다. 본 연구는 SICM mapping의 기본이 되는 tip과 시료 간의 거리에 의한 전류 반응곡선인 approach curve에 대해 연구한 결과를 담고 있다. Approach curve에 대해 우선 시뮬레이션 해석을 진행하였으며, 이를 기반으로 실험을 병행하여 이 둘 사이의 반응 곡선 차이를 분석하였다. 시뮬레이션 해석을 통해 tip과 시료와의 거리가 tip 내경의 절반 이하로 가까워지면서 current squeezing 효과를 확인할 수 있었다. 하지만, 시뮬레이션에 반영된 단순 이온 통로 감소에 의한 전류밀도 감소는 실제 실험을 통해 측정된 current squeezing 효과에 비해 훨씬 작은 것으로 측정되었다. 이는 나노 스케일의 매우 좁은 통로에서 이온전도도는 확산계수에 의한 단순 Nernst-Einstein 관계를 따르는 것이 아니라, tip과 시료가 만들어 내는 벽면에서의 유체역학적 유동 저항성을 고려하는 것이 추가로 필요할 것으로 보인다. 향후 이러한 SICM 측정은 전기화학 표면 반응성을 분석하는 SECM (scanning electrochemical microscopy) 측정기술과 통합되어 SECM 측정 한계를 보완될 수 있을 것으로 기대된다. 그렇게 되면, 반도체 배선 공정 및 패키징 공정에 사용되고 있는 다양한 패턴 형상에서 무전해 도금의 촉매 반응과 전기도금에서 유기첨가제 작용의 국부적 차이를 직접적으로 측정하는 것이 가능하게 될 것으로 기대된다.

한우 수정란의 발달 단계별 산소 소비량 변화 (Changes in Oxygen Consumption Rates of Embryos in Korean Cattle)

  • 최창용;조상래;손준규;최선호;조창연;김재범;김성재;강다원;손동수
    • 한국수정란이식학회지
    • /
    • 제24권3호
    • /
    • pp.231-235
    • /
    • 2009
  • Oxygen consumption has been regarded as a useful indicator for assessment of mammalian embryo quality. However, there was no standard criterion to measure the oxygen consumption of embryos. Here, we measured oxygen consumption of bovine embryos at various developmental stages was measured using a scanning electrochemical microscopy (SECM). We found that the oxygen consumption significantly increased in blastocyst-stage embryos compared to other stage embryos (from 2-cell-stage to morula-stage), indicating that oxygen consumption reflects the cell number ($5.2{\sim}7.6{\times}10^{14}/mol\;s^{-1}$ versus $1.2{\sim}2.4{\times}10^{14}/mol\;s^{-1}$, p<0.05). In the morula-stage embryos, the oxygen consumption of in vivo derived embryos was significantly higher than that of in vitro produced embryos ($4.0{\times}10^{14}/mol\;s^{-1}$ versus $2.4{\times}10^{14}/mol\;s^{-1}$, p<0.05). However, there was no significant difference in consumption of oxygen by in vivo and in vitro-derived bovine blastocyst-stage embryos (p>0.05). In the frozen-thawed blastocyst-stage embryos, live embryos showed significantly higher oxygen consumption than dead embryos ($4.7{\times}10^{14}/mol\;s^{-1}$ versus $1.0{\times}10^{14}/mol\;s^{-1}$, p<0.05). These results indicate that the measuring oxygen consumption by SECM can be used to evaluate bovine embryo quality.

인간 난자의 체외수정을 위한 정도관리로서 생쥐 착상전 배아의 배양에 관한 연구 (Mouse Embryo Culture as Quality Control for Human IVF:Culture Media and Supplements)

  • 이기숙;박종덕;이춘근;김종덕
    • Clinical and Experimental Reproductive Medicine
    • /
    • 제16권2호
    • /
    • pp.161-171
    • /
    • 1989
  • The development of 2-cell mouse embryos to the blastocyst stage in vitro has been used as quality control for the culture media and supplements employed for human in vitro fertilization and embryo transfer(IVF-ET). 2-cell mouse embryos were cultured to the blastocyst stage in SECM, Medium 199-Earle's, Ham's F-10 I , Ham's F-10 II , Hoppe & Pitts, MEM and $HT_6$. The protein supplements contained in media were bovine serum albumine, fetal bovine serum and human fetal cord serum. The results were as follows; 1. The successful development was 81.3% in Medium 199-Earle’s, 91.9% in Ham’s F-10 I and 97.1% in $HT_6$. 2. 2-cell mouse embryos developed properly in all supplements but the best development was particularly noted in $HT_6$ media when HFCS was supplied as protein supplement.

  • PDF

시스템엔지니어링을 적용한 철도안전프로젝트의 시스템엔지니어링 능력성숙도 평가 (An assessment of the Systems Engineering Capability Maturity of the Railway Safety Project applied the Systems Engineering)

  • 최요철;이재천
    • 시스템엔지니어링학술지
    • /
    • 제4권2호
    • /
    • pp.55-61
    • /
    • 2008
  • In this paper, there is the case study which assesses the systems engineering capability maturity of the safety organization that performs the Railway Safety project using systems engineering method. To In ore effective and efficient a research and development to railway safety domain, a new research and development method can be progressively needed such as systems engineering. To assess quantitatively research of systems engineering efforts in the railway safety project, SECM(EIA/IS 731) Standard is utilized in the paper. It is by questionnaire that the capability maturity assessment is executed wit h the safety organization and staffs who performs the systems engineering activities; requirement analysis and management, interface control management. product verification and validation, and so on. As a result, the systems engineering capability level of the safety organization rises from 0 level at the initial project to 2 level after two years and all staffs give an affirmative answer about the importance and effectiveness of the systems engineering approach.

  • PDF