• Title/Summary/Keyword: SEAWATER FISH

Search Result 270, Processing Time 0.023 seconds

Evaporating heat transfer characteristics of Aluminum-brass tube for seawater cooling system using R-134a (해수냉각시스템용 Aluminium Brass Tube의 R-134a 증발열전달 특성)

  • Kang, In-Ho;Seol, Sung-Hoon;Yoon, Jung-In;Son, Chang-Hyo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.41 no.3
    • /
    • pp.197-201
    • /
    • 2017
  • Most fishing vessels use an ice cooling system to manage and store captured fish. However, it is difficult to maintain an adequate temperature and salt concentration as well as operating time limitations in ice cooling systems. The purpose of this study is to investigate the heat transfer characteristics of flooded-type evaporators for a seawater cooling system to maintain proper seawater temperature in a fish tank. Experiments were conducted to investigate the heat transfer characteristics by changing the seawater temperature, flow rate, and saturation temperature of the refrigerant. It was confirmed that the heat transfer coefficient of an aluminum-brass tube was approximately 10% higher than that of a copper-nickel tube at the same heat flux. Furthermore, it was confirmed that applying the aluminum-brass tube to the heat transfer tube of a seawater heat exchanger was effective in terms of heat transfer. A comparison of the overall heat transfer coefficient of a single-tube heat exchanger and the flooded-type multi-tube heat exchanger for an 18-kW cooling system showed that the heat transfer coefficient of the single-tube heat exchanger was 25% higher under the same conditions. These results are considered to be important data for designing a flooded-type multi-tube heat exchanger.

Statistical Analysis of Water Quality in a Land-based Fish Farm (육상 수조식 양식장 수질 환경의 통계적 분석)

  • Kim, Hae-Ran;Ceong, Hee-Taek
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.5 no.6
    • /
    • pp.637-644
    • /
    • 2010
  • The purpose of this study is to analyze characteristics of water quality factor scientifically and develop the multiple regression model predicting dissolved oxygen to save periodic replacement costs for dissolved oxygen sensor. Correlation analysis using the environmental data obtained from 2 different land-based fish farms of the Geogeum-do, Geheung-gun coastal area during the periods from November 2008 to January 2009 shows that water temperature was negatively correlated with dissolved oxygen and pH butpH was positively correlated with salinity and dissolved oxygen. The information of Keumho fish farm in 2009 is presented by the tables which are monthly statistics of water quality factors and seasonable difference by the Duncan's post-test. Also we developed multiple regression model predicting dissolved oxygen, the usefulness of which was verified by the comparison graph between estimates and actual observations. The developed regression model shows that seawater temperature and salinity give negative affect to dissolved oxygen while pH gives positive affect to it. Lastly the seawater temperature has much higher explanatory power than pH factor.

Preliminary Study of the Effects of CO2 on the Survival and Gowth of Olive Flounder (Paralichthys olivaceus) Juveniles

  • Hwang, In-Joon;Park, Mun-Chang;Baek, Hea-Ja
    • Fisheries and Aquatic Sciences
    • /
    • v.12 no.4
    • /
    • pp.350-353
    • /
    • 2009
  • As a result of human industrial development, carbon dioxide ($CO_2$) is currently accumulating in the atmosphere and dissolving into the oceans. Sequestration into the deep sea has been proposed as a possible solution to this increasing atmospheric $CO_2$, although the impact of such a program on marine ecosystems is unknown. We examined the effects of increased $CO_2$ levels on the growth of the olive flounder, Paralichthys olivaceus. Juvenile olive flounder 40 days post hatching were exposed to two levels of $CO_2$ (3.60-7.55 and 4.05-11.46 kPa) in running seawater for 26 days. During the exposure period, the pH and $CO_2$ levels of the water were measured, and the numbers of dead individuals were counted in each aquarium. Following the exposure period, the total lengths (mm) and body weights (mg) of the juvenile fish were measured. Both $CO_2$ treatments significantly increased fish mortality compared to controls ($19.87\pm4.53%$ vs. 7.14% and $75.96\pm1.36%$ vs. 7.14% for high and low doses, respectively). After the high $CO_2$ treatment, total length ($14.98\pm6.58$ mm vs. $19.52\pm1.83$ mm) and body weight ($28.92\pm13.85$ mg vs. $67.35\pm18.32$ mg) of the exposed flounder were reduced compared to the control fish; however, no significant differences in these values were observed after the low $CO_2$ dose. These results suggested that $CO_2$ exposure inhibits growth in the juvenile stage and that $CO_2$-enriched seawater is toxic in the early life stages of olive flounder.

Performance of a Lab-Scale Closed Seawater Recirculating System for Korean Rockfish Sebastes schlegeli Culture

  • Peng, Lei;Oh, Sung-Yong;Jo, Jae-Yoon
    • Ocean and Polar Research
    • /
    • v.25 no.4
    • /
    • pp.493-501
    • /
    • 2003
  • Performance of a laboratory scale closed seawater recirculating aquaculture system was evaluated. Twenty-kg of korean rockfish (130 fish) with an average body weight of 153.8g was stocked. Over a 107-day culture period, fish reached final density of $51.7kg/m^3$ (initial density, $33.3kg/m^3$) on the basis of the culture tank volume. On a daily basis, added water amounted to 3.4% of the total water volume in the system. Total ammonia nitrogen (TAN) concentrations were below 1mg/l and nitrite nitrogen $(NO_2-N)$ concentrations were within the range of 1-3mg/l on most sampling days. TAN was removed from bead and sand filters and it was removed or produced in the sedimentation basin. Basically, $NO_2-N$ was removed in the bead and sand filters, while it was either removed or produced in the sedimentation basin. Nitrate nitrogen $(NO_3-N)$ was produced in the bead filters and removed from the sand filter and sedimentation basin. The foam fractionator performed well in the recirculating system. The maximal daily removal values for total suspended solids (755) and protein were 10.9g and 1.4g, respectively. Whole water quality parameters were within the levels commonly recommended for fish culture on most of the sampling days. However, further studies are needed to evaluate the commercial feasibility of this system because of the smallscale system used in present experiment. At least, the present study still provides some basic information for further studies of this kind of system.

Variation in the Residual Oils in the Culture Grounds on the Taean Coast, Korea after the Hebei Spirit Oil Spill (Hebei Spirit호 유류유출 사고 이후 태안 양식어장에서 잔존유류의 농도 변화)

  • Kim, Hyung-Chul;Lee, Wan-Seok;Hwang, Un-Ki;Choi, Yong-Suk
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.43 no.6
    • /
    • pp.705-714
    • /
    • 2010
  • The residual oil concentrations in seawater and sediments were investigated along the Taean coast of Korea, following the Hebei Spirit oil spill, which occurred on 7 December 2007. The oil concentration in seawater ranged from 0.059 to $0.866\;{\mu}g/L$ for the tidal flat culture grounds and from 0.016 to $0.943\;{\mu}g/L$ in the fish cage areas in 2008. These were dominated by the seawater temperature relationship. Polycyclic aromatic hydrocarbons (PAHs) in sediments were also analyzed and the concentrations ranged from 3.4 to 509.7 ng/g dry weight. The average PAH level was higher in seawater from the Sinduri area than the Padori area, while the average PAH level in sediments was higher in Padori. The diagnostic ratio of PAHs was investigated to determine the origins of the PAHs. The PAHs in the Seongam area, which was not affected by the oil spill, are of pyrolytic origin, while the PAHs in Padori and Sinduri were of petrogenic origin. The residual oils in the areas affected by the oil spill tended to decrease over time, except in summer. The oils in pore water remained 6- to 16-fold higher, as compared to the seawater overlying the tidal flat, implying that residual oils will continue to influence the affected region for the foreseeable future.

Characterization of Edwardsiella tarda specific phage isolated from fish farms on west coast of Korea (서해안 양식장에서 분리한 Edwardsiella tarda의 특이 bacteriophage 특성)

  • Lee, Chan-Heun;Heo, Yong-Ju;Baek, Min-Suk;Lee, Jung-Uen;Kang, Ja-Young;Han, Mi-Jung;Kyoung, Se-Bong;Choi, Sang-Hoon
    • Journal of fish pathology
    • /
    • v.24 no.2
    • /
    • pp.85-93
    • /
    • 2011
  • Edwardsiella tarda is a broadly infectious agent against freshwater and seawater fishes. In the present study, E. tarda specific phage was isolated from fish farms on the west coast of Korea, and the effect of environmental factors such as pH and water temperature on the phage activity was investigated. As a fish model, Nile tilapia (Oreochromis niloticus) was used and the interaction between E. tarda and phage was investigated. The phage activity, in pH test, appeared even higher in seawater than freshwater and was evenly constant up to $50^{\circ}C$. The phage and E. tarda were inoculated in tilapia and the phage activity and E. tarda viability were checked on the time intervals. As a result, the number of E. tarda in the group of E. tarda plus phage was constantly reduced to 24 hr post-inoculation compared to the control group without phage, whereas the phage activity was slightly increased in the experiment group. The results suggest that it might be possible to use phage to control the fish disease caused by E. tarda.

Investigation of Microbial Contamination the Level in Fish Farms of Jeju East Coast. (제주 동부 연안 넙치 양식장의 미생물학적 오염도 조사)

  • Kim, Yun-Beom;Moon, Young-Gun;Ha, Jin-Hwan;Kang, Chang-Hee;Kam, Sang-Kyu;Song, Chun-Bok;Oh, Myung-Cheol;Heo, Moon-Soo
    • Journal of Life Science
    • /
    • v.18 no.3
    • /
    • pp.395-402
    • /
    • 2008
  • Level of microbial contamination was examined in four fish farms of Jeju east coast for sanitary indication of bacterial contamination such as heterotrophic bacteria, Escherichia coli O157:H7, Salmonella spp., Vibrio parahaemolyticus, Staphylococcus aureus, Bacillus cereus and total coliforms. The samples were collected and investigated from June to October in 2007. Bacterial species of S. aureus, B. cereus and Salmonella spp. were frequently detected from the seawater of above fish farms. Salmonella spp., S. aureus, B. cereus were detected in the range of $0{\sim}4.3{\times}l0^3,\;0{\sim}2.7{\times}l0^4,\;0{\sim}7.6{\times}l0^3$ CFU/ml, respectively, from the fish feed used in all four selected farms. Additionally, Salmonella spp., S. aureus, B. cereus were detected in oliver flounder (Paralichthys olivaceus) of these farms, however total coliforms and E. coli O157:H7 were not detected during our experimental period. For the production of microbiologically safe and healthy oliver flounder, proper quality control of feed, sanitation programs, and continuous monitoring of microorganism are essential practices, which required to include in the farm management system.

Measurement of Waste Generation in Seawater Aquaria by Common Conger (Astroconger myriaster) arld Olive Flounder (Paralichyhus olivaceus) (해수활어수조에서 붕장어 (Astroconger myriaster)와 넙치 (Puralichyhus olivaceus)에 의한 오염물 발생량 산정)

  • SUH Kuen-Hack;SHIN Jeong-Sik;JO Jae-Yoon
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.37 no.6
    • /
    • pp.492-497
    • /
    • 2004
  • Waste concentration and waste generation rate in seawater aquaria by common conger (Astrocongey myriaster) and olive flounder (Paralichyhus olivaceus) were investigated. The initial fish density of common conger and olive flounder were $3{\%}\;and \;2.8{\%}$ of total weight of aquarium water, respectively Wastes in the seawater aquaria, such as protein, total suspended solid (TSS), ammonia, turbidity and chemical oxygen demand (COD) increased with days after stocking. Protein generation rate of common conger increased until 1 day after stocking while that of olive flounder increased until 3 days. The average protein generation rates of common conger and olive flounder were $0.28g/kg{\cdot}day\;and\;0.21g/kg{\cdot}day$, respectively. The trends of other waste generation rate were similar to protein generation rate.

Optimum Conditions for Denitrification and Fish Growth in a Seawater Recirculating System (해수 탈질시스템에서 적정 탈질조건과 어류의 사육효과)

  • SON Maeng Hyun;JEON Im Gi
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.36 no.5
    • /
    • pp.458-462
    • /
    • 2003
  • This study was to survey proper condition of nitrate removal by hydraulic retention time (HRT) and measured growth of black rockfish (Sebastes schlegeli) and giant croaker (Nibea japonica) in the seawater recirculating culture system designed for nitrate removal. Nitrate conversion to nitrogen at 8 hr-HRT was higher than 16 hr-HRT, amounting to $32.2\;g/m^3/day$ in the seawater recirculating culture system. The removal efficiency of nitrate improved when dissolved oxygen was situated less than 0.5 mg/L. Daily growth rate (DGR) and feed efficiency (FE) of S. schlegeli with mean body weight of 108 g in 8 hr-HRT were significantly higher values than those in 4 hr-HRT (P<0.05). The DGR and FE of N. japonica with mean body weight of 12 g in added carbon system showed not differing in the values from N. japonica in control system (P>0.05).

Analysis of energy-saving effects of recirculation aquaculture system using seawater source heat pumps and solar power generation (해수 열원 히트펌프와 태양광 발전을 이용한 순환여과식 양식장의 에너지 절감 효과 분석)

  • Jong-Hyeok RYU;Hyeon-Suk JEONG;Seok-Kwon JEONG
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.60 no.2
    • /
    • pp.194-206
    • /
    • 2024
  • This study focuses on analyzing the energy-saving effects of the recirculation aquaculture system using seawater source heat pumps and solar power generation. Based on the thermal load analysis conducted using the transient system simulation tool, the annual energy consumption of the recirculation aquaculture system was analyzed and the energy-saving effects of utilizing the photovoltaic system was evaluated. When analyzing the heat load, the sea areas where the fish farms are located, the type of breeding tank, and the circulation rate of breeding water were taken into consideration. In addition, a method for determining the appropriate capacity for each operation time was examined when applying the energy storage system instead of the existing diesel generator as an emergency power, which is required to maintain the water temperature of breeding water during power outage. The results suggest that, among the four seas considered, Jeju should be estimated to achieve the highest energy-saving performance using the solar power generation, with approximately 45% energy savings.