• Title/Summary/Keyword: SDOF system

Search Result 143, Processing Time 0.025 seconds

Computing input energy response of MDOF systems to actual ground motions based on modal contributions

  • Ucar, Taner
    • Earthquakes and Structures
    • /
    • 제18권2호
    • /
    • pp.263-273
    • /
    • 2020
  • The use of energy concepts in seismic analysis and design of structures requires the understanding of the input energy response of multi-degree-of-freedom (MDOF) systems subjected to strong ground motions. For design purposes and non-time consuming analysis, however, it would be beneficial to associate the input energy response of MDOF systems with those of single-degree-of-freedom (SDOF) systems. In this paper, the theoretical formulation of energy input to MDOF systems is developed on the basis that only a particular portion of the total mass distributed among floor levels is effective in the nth-mode response. The input energy response histories of several reinforced concrete frames subjected to a set of eleven horizontal acceleration histories selected from actual recorded events and scaled in time domain are obtained. The contribution of the fundamental mode to the total input energy response of MDOF frames is demonstrated both graphically and numerically. The input energy of the fundamental mode is found to be a good indicator of the total energy input to two-dimensional regular MDOF structures. The numerical results computed by the proposed formulation are verified with relative input energy time histories directly computed from linear time history analysis. Finally, the elastic input energies are compared with those computed from time history analysis of nonlinear MDOF systems.

Evaluation of N2 method for damage estimation of MDOF systems

  • Yaghmaei-Sabegh, Saman;Zafarvand, Sadaf;Makaremi, Sahar
    • Earthquakes and Structures
    • /
    • 제14권2호
    • /
    • pp.155-165
    • /
    • 2018
  • Methods based on nonlinear static analysis as simple tools could be used for the seismic analysis and assessment of structures. In the present study, capability of the N2 method as a well-known nonlinear analysis procedure examines for the estimation of the damage index of multi-storey reinforced concrete frames. In the implemented framework, equivalent single-degree-of-freedom (SDOF) models are utilized for the global damage estimation of multi-degree-of-freedom (MDOF) systems. This method does not require high computational analysis and subsequently decreases the required time of seismic design and assessment process. To develop the methodology, RC frames with period range from 0.4 to 2.0 s under 40 records are studied. The effectiveness of proposed technique is evaluated through numerical study under near- and far-field earthquake ground motions. Finally, the results of developed models are compared with two other simplified schemes along with nonlinear time history analysis results of multi-storey frames. To improve the accuracy of damage estimation, a modified relation is presented based on the N2 method results for near- and far-field earthquakes.

비보강 조적조의 비선형 동적 거동의 전개 (An Evolution of Nonlinear Dynamic Response of an Unreinforced Masonry Structure)

  • 김남희
    • 한국지진공학회논문집
    • /
    • 제10권3호
    • /
    • pp.77-84
    • /
    • 2006
  • 비보강 조적조는 비균일 재료로 이루어진 합성재료에 가까우므로 그 거동이 하중종류와 구조물의 손상 정도에 따라서 매우 달라지게 된다. 본 연구에서는 여러 차례의 모의 지진을 받는 구조물의 손상거동이 어떻게 전개되어 가는지 살펴보는 간단한 방법을 제시한다. 특히, 시간영역 자료를 여러 구간으로 나누어서 주파수가 어떻게 변화해 가는지 살펴보는 부분 FFT방법을 이용하였다. 또한, 주파수와 강도와의 관계식을 이용하여 단자유도계의 이선형모델도 유도하였다. 본 연구에서 제시하는 이러한 방법들을 이용하여 비보강 조적조의 비탄성 성질들을 합리적으로 구할 수 있었다.

A new study in designing MTMDs in SDOF and MDOF systems based on the spectral analysis method

  • Baigoly, Morteza;Shargh, Farzan H.;Rofooei, Fayaz R.
    • Earthquakes and Structures
    • /
    • 제19권4호
    • /
    • pp.243-259
    • /
    • 2020
  • This study aims to optimize, design, and predict the MTMDs performance in SDOF systems using spectral analysis, and then apply their results to MDOF structures. Given the importance of spectral analysis in the design of new engineering structures, achieving a method for designing TMDs based on this theory can be of great importance for structural designers. In this study, several convenient combinations of MTMDs in an SDOF system are first considered to minimize the maximum displacement. For calculating the frequency ratios of dampers, an innovative technique is adopted in which the values of different modal responses obtained from the spectral analysis are approached together. This procedure is done using a harmony search (HS) algorithm. Also, using the random vibration theory, the damping ratio of the dampers is obtained. Then, an equation is presented for predicting the performance of MTMDs. For evaluating this equation, three structures with different stories are designed. Some of the presented combinations of dampers are added to them. The time history analyses are employed to analyze the structures under 30 different accelerograms. The findings indicated that the proposed equation could efficiently predict the performance of the MTMDs. Furthermore, four different patterns of damper distribution along the height of the structures are defined. The effect of them on the maximum deformation of the structures in time history analyses is discussed, and an equation is presented to estimate this effect. The results indicated that the average and maximum error percentages of the proposed equations are about three and seven percent, respectively, compared to the time history analyses results, which are negligible values.

다양한 기초 형식에 따른 단자유도 구조물 지진하중 평가를 위한 동적 원심모형실험 (Dynamic Centrifuge Tests for Evaluating the Earthquake Load of the Structure on Various Foundation Types)

  • 하정곤;조성배;박헌준;김동관;김동수
    • 한국지진공학회논문집
    • /
    • 제20권5호
    • /
    • pp.285-293
    • /
    • 2016
  • Soil-foundation-structure interaction (SFSI) is one of the important issues in the seismic design for evaluating the exact behavior of the system. A seismic design of a structure can be more precise and economical, provided that the effect of SFSI is properly taken into account. In this study, a series of the dynamic centrifuge tests were performed to compare the seismic response of the single degree of freedom(SDOF) structure on the various types of the foundation. The shallow and pile foundations were made up of diverse mass and different conjunctive condition, respectively. The test specimen consisted of dry sand deposit, foundation, and SDOF structure in a centrifuge box. Several types of earthquake motions were sequentially applied to the test specimen from weak to strong intensity of them, which is known as a stage test. Results from the centrifuge tests showed that the seismic responses of the SDOF structure on the shallow foundation and disconnected pile foundation decreased by the foundation rocking. On the other hand, those on the connected pile foundation gradually increased with intensity of input motion. The allowable displacement of the foundation under the strong earthquake, the shallow and the disconnected pile foundation, have an advantage in dissipating the earthquake energy for the seismic design.

Accuracy of combination rules and individual effect correlation: MDOF vs SDOF systems

  • Reyes-Salazar, Alfredo;Valenzuela-Beltran, Federico;de, Leon-Escobedo, David;Bojorquez, Eden;Lopez-Barraza, Arturo
    • Steel and Composite Structures
    • /
    • 제12권4호
    • /
    • pp.353-379
    • /
    • 2012
  • The accuracy of the 30% and SRSS rules, commonly used to estimate the combined response of structures, and some related issues, are studied. For complex systems and earthquake loading, the principal components give the maximum seismic response. Both rules underestimate the axial load by about 10% and the COV of the underestimation is about 20%. Both rules overestimate the base shear by about 10%. The uncertainty in the estimation is much larger for axial load than for base shear, and, for axial load, it is much larger for inelastic than for elastic behavior. The effect of individual components may be highly correlated, not only for normal components, but also for totally uncorrelated components. The rules are not always inaccurate for large values of correlation coefficients of the individual effects, and small values of such coefficients are not always related to an accurate estimation of the response. Only for perfectly uncorrelated harmonic excitations and elastic analysis of SDOF systems, the individual effects of the components are uncorrelated and the rules accurately estimate the combined response. In the general case, the level of underestimation or overestimation depends on the degree of correlation of the components, the type of structural system, the response parameter, the location of the structural member and the level of structural deformation. The codes should be more specific regarding the application of these rules. If the percentage rule is used for MDOF systems and earthquake loading, at least a value of 45% should be used for the combination factor.

지진하중을 받는 단자유도 구조물의 신속한 동적 신뢰성 추정 방법 (Fast Dynamic Reliability Estimation Approach of Seismically Excited SDOF Structure)

  • 이도근;옥승용
    • 한국안전학회지
    • /
    • 제35권5호
    • /
    • pp.39-48
    • /
    • 2020
  • This study proposes a fast estimation method of dynamic reliability indices or failure probability for SDOF structure subjected to earthquake excitations. The proposed estimation method attempts to derive coefficient function for correcting dynamic effects from static reliability analysis in order to estimate the dynamic reliability analysis results. For this purpose, a total of 60 cases of structures with various characteristics of natural frequency and damping ratio under various allowable limits were taken into account, and various types of approximation coefficient functions were considered as potential candidate models for dynamic effect correction. Each reliability index was computed by directly performing static and dynamic reliability analyses for the given 60 cases, and nonlinear curve fittings for potential candidate models were performed from the computed reliability index data. Then, the optimal estimation model was determined by evaluating the accuracy of the dynamic reliability analysis results estimated from each candidate model. Additional static and dynamic reliability analyses were performed for new models with different characteristics of natural frequency, damping ratio and allowable limit. From these results, the accuracy and numerical efficiency of the optimal estimation model were compared with the dynamic reliability analysis results. As a result, it was confirmed that the proposed model can be a very efficient tool of the dynamic reliability estimation for seismically excited SDOF structure since it can provide very fast and accurate reliability analysis results.

기초체계의 운동학적 상호작용을 고려한 고층건물의 응답스펙트럼에 미치는 고차모드의 영향 (Effects of Higher Modes on the Response Spectra of High-rise Buildings considering the Kinematic Interaction of a Foundation System)

  • 김용석
    • 한국지진공학회논문집
    • /
    • 제19권3호
    • /
    • pp.85-92
    • /
    • 2015
  • Response spectra of a building are made with a SDOF system taking into account a first mode shape, even though higher modes may affect on the dynamic responses of a high-rise building. A soft soil layer under a building also affects on the responses of a building. In this study, seismic responses of a MDOF system were investigated to examine the effects of higher modes on the response of a tall building by comparing them with those of a SDOF system including the kinematic interaction effect. Study was performed using a pseudo 3D finite element program with seven bedrock earthquake records downloaded from the PEER database. Effects of higher modes on the seismic responses of a tall building were investigated for base shear force and base moment of a MDOF system including story shear forces and story moments. Study results show that higher modes of a MDOF system contribute to a reduction of base shear force up to 1/4-1/5 of KBC and base moment. The effect of higher modes is more significant on the base shear force than on the base moment. Maximum story shear force and moment occurred at the top part of a building rather than at a base in the cases of tall buildings differently from short buildings, and higher modes of a tall building affected on the base forces making them almost constant at the base. A soft soil layer also affects some on the base shear force of a high-rise building independently on the soft soil type, but a soft soil effect is prominent on the base moment.

배율조정 및 스펙트럼 맞춤 입력지반운동 모델에 대한 비선형 단자유도 시스템의 파손확률 (Failure Probability of Nonlinear SDOF System Subject to Scaled and Spectrum Matched Input Ground Motion Models)

  • 김동석;고현무;최창열;박원석
    • 한국지진공학회논문집
    • /
    • 제12권1호
    • /
    • pp.11-20
    • /
    • 2008
  • 비선형 구조계의 확률론적 지진해석 방법 중 대표적인 것은 지진 재해도 수준에 해당하는 입력지반운동 모델을 사용한 시간이력을 수행하여 그 응답의 확률분포를 예측하는 것이다. 이 연구에서는 널리 사용되고 있는 두 가지 입력지반운동 모델에 따른 구조계 응답의 분포특성 및 파손확률의 차이와 그 원인을 분석한다 입력지반운동 모델로는 실제 지진기록을 배율 조정하여 사용하는 배율조정 입력지반운동과 설계 응답스펙트럼에 상응하는 인공 지진기록을 사용하는 스펙트럼 맞춤 입력지반운동 두 가지를 고려한다. 동일한 지진재해도 수준을 고려한 해석결과 설계 응답스펙트럼에 상응하는 인공 지진기록을 사용한 입력지반운동 모델은 실제 지진기록을 배율 조정한 입력지반운동 모델보다 평균적으로 응답을 크게 평가하였고 이로 인해 파손확률 또한 더 큰 것으로 나타났다 이러한 경향은 연약한 지반에서 더욱 현저한 것으로 나타났다. 이러한 입력지반운동 모델에 따른 파손확률의 차이는 스펙트럼 맞춤 입력지반운동의 목표로 사용된 도로교 설계기준의 설계 응답스펙트럼이 실제 지진기록의 응답스펙트럼보다 장주기로 갈수록 응답을 크게 평가하도록 보수적으로 만들어졌기 때문인 것으로 나타났다.

Ductility demand of partially self-centering structures under seismic loading: SDOF systems

  • Hu, Xiaobin;Zhang, Yunfeng
    • Earthquakes and Structures
    • /
    • 제4권4호
    • /
    • pp.365-381
    • /
    • 2013
  • In this paper, a numerical simulation study was conducted on the seismic behavior and ductility demand of single-degree-of-freedom (SDOF) systems with partially self-centering hysteresis. Unlike fully self-centering systems, partially self-centering systems display noticeable residual displacement after unloading is completed. Such partially self-centering behavior has been observed in a number of recently researched self-centering structural systems with energy dissipation devices. It is thus of interest to examine the seismic performance such as ductility demand of partially self-centering systems. In this study, a modified flag-shaped hysteresis model with residual displacement is proposed to represent the hysteretic behavior of partially self-centering structural systems. A parametric study considering the effect of variations in post-yield stiffness ratio, energy dissipation coefficient, and residual displacement ratio on the displacement ductility demand of partially self-centering systems was conducted using a suite of 192 scaled ground motions. The results of this parametric study reveal that increasing the post-yield stiffness, energy dissipation coefficient or residual displacement ratio of the partially self-centering systems generally leads to reduced ductility demand, especially for systems with lower yield strength.