• 제목/요약/키워드: SCR system

검색결과 377건 처리시간 0.027초

SCR 시스템의 효율적인 운영을 위한 Soot Blowing 방법에 대한 해석적 연구 (Computational Study on the Soot Blowing Method for Enhancing the Performance of the SCR System)

  • 서문혁;장혁상
    • 한국입자에어로졸학회지
    • /
    • 제8권3호
    • /
    • pp.99-110
    • /
    • 2012
  • In the SCR (selective catalytic reduction) system which is used for controlling the NOx emission from the Diesel engines, the soot deposited on the catalysis causes degradation of the system performance. Numerical study was done to evaluate the performance of soot blower which is proposed as a method for removing the soot on the catalysis. The spray conditions and the effect of the compressed air from the AIG (air inlet gun) were analyzed numerically to evaluate the overall effective method of the soot blowing. The characteristics of the final velocity distribution and velocity waves across the inlet section of the catalysis were evaluated with respect to the geometries of the AIG outlets and pressure conditions. An experimental model was used to validate the results of the numerical calculation that is used for finding the effective removal blowing momentum transfer quantities of soot the inlet section of the catalysis, and it is proposed that the required minimum blowing momentum transfer quantities are over than 0.499 $kg/m{\bullet}t_{eff}$ in the current study.

ECU 커먼레일 디젤기관에 있어서 매연 및 NOX 배출물 동시 저감용 일체형 요소-SCR 촉매필터 시스템의 특성에 관한 연구 (A Study on Characteristics of an Integrated Urea-SCR Catalytic Filter System for Simultaneous Reduction of Soot and NOX Emissions in ECU Common-rail Diesel Engines)

  • 배명환
    • 한국자동차공학회논문집
    • /
    • 제22권4호
    • /
    • pp.111-120
    • /
    • 2014
  • The aim of this study is to develop an integrated urea-SCR catalytic filter system for reducing soot and $NO_X$ emissions simultaneously in diesel engines. In this study, the characteristics of exhaust emissions relative to reactive activation temperature under four kinds of engine loads are experimentally investigated by using a four-cycle, four-cylinder, direct injection type, water-cooled turbo intercooler ECU common-rail diesel engine with the integrated urea-SCR $MnO_2-V_2O_5-WO_3/TiO_2/SiC$ catalytic filter system operating at three kinds of engine speeds. The urea-SCR reactor is used to reduce $NO_X$ emissions, and the catalytic filter system is used to reduce soot emissions. The reactive activation temperature is very important for reacting a reducing agent with exhaust emissions. The reactive activation temperatures in this experiment is applied to 523, 573 and 623 K. The fuel is sprayed by the pilot and main injections at the variable injection timing between BTDC $15^{\circ}$ and ATDC $1^{\circ}$ according to experimental conditions. It is found that the $NO_X$ conversion rate is the highest as 83.9% at the reactive activation temperature of 523 K in all experimental conditions of engine speed and load, and the soot emissions shown by the average reduction rate of approximately 93.3% are almost decreased below 0.6% in all experimental conditions regardless of reactive activation temperatures. Also, the THC and CO emissions by oxidation reaction of Mn, V and Ti are shown in the average reduction rates of 70.3% and 38% regardless of all experimental conditions.

SCR 촉매와 AOC 촉매에서 환원제 분사에 따른 $NO_x$ 저감효율과 $NH_3$ 변환효율에 관한 실험적 연구 (An Experimental Study on $NO_x$ Reduction Efficiency and $NH_3$ Conversion Efficiency under Various Conditions of Reductant Injection on SCR and AOC)

  • 동윤희;최정황;조용석;이성욱;이승호;오상기;박현대
    • 한국자동차공학회논문집
    • /
    • 제18권5호
    • /
    • pp.85-90
    • /
    • 2010
  • As the environmental regulation of vehicle emission is strengthened, investigations for $NO_x$ and PM reduction strategies are popularly conducted. Two current available technologies for continuous $NO_x$ reduction onboard diesel vehicles are Selective Catalytic Reduction (SCR) using aqueous urea and lean $NO_x$ trap (LNT) catalysts. The experiments were conducted to investigate the $NO_x$ reduction performance of SCR system which can control the ratio of $NO/NO_2$, temperature and SV(space velocity), and the model gas was used which is similar to a diesel exhaust gas. The maximum reduction efficiency is indicated when the $NO:NO_2$ ratio is 1:1 and the SV is 30,000 $h^{-1}$ in $300^{\circ}C$. Generally, ammonia slip from SCR reactors are rooted to incomplete conversion of $NH_3$ over the SCR. In this research, slip was occurred in 6cases (except low SV and $NO:NO_2$ ratio is 1:1) after SCR. Among 6 case of slip occurrence, the maximum conversion efficiency is observed when SV is 60,000 $h^{-1}$ in $400^{\circ}C$.

선박용 디젤엔진 SCR 시스템에 NOx 환원제로 사용되는 암모늄 카바메이트의 물질 성분 분석 연구 (Analysis of Ammonium Carbamate Used as a NOx Reducing Agent for the SCR System of Marine Diesel Engines)

  • 김홍석;류영현
    • 해양환경안전학회지
    • /
    • 제26권6호
    • /
    • pp.751-758
    • /
    • 2020
  • 선박용 디젤엔진의 NOx 환원제로 액체 우레아를 사용하는 SCR 기술이 널리 사용되고 있다. 하지만 액체 우레아 대신에 고체상의 암모늄 카바메이트를 NOx 환원제로 사용하면 저온 NOx 저감율 및 암모니아 저장용량 측면 등에서 다양한 장점이 있다. 이에 따라 본 연구에서는 암모늄 카바메이트를 EA, FTIR, XRD 방법으로 분석하여 순도를 관리하는 방법을 제시하고자 하였으며, 다양한 온도와 압력 조건에 암모늄 카바메이트가 노출되었을 때의 물질 변화 특성을 고찰하고자 하였다. 본 연구를 통하여 암모늄 카바메이트의 순도를 EA 분석을 통해 효과적으로 관리 할 수 있음을 알 수 있었으며, 선박용 디젤엔진의 SCR 시스템에 적용될 것으로 예상되는 열분해 온도 조건에서 가열과 냉각을 반복한 암모늄 카바메이트에 대한 FTIR 분석결과, 물질 특성은 변화하지 않는 것을 확인하였다. 또한, 대기 중에 장기간 노출된 암모늄 카바메이트는 암모늄 카보네이트로 물질 변화함을 알 수 있었다.

SCR를 이용한 유도전동기의 속도제어에 관한 연구 (Speed Control of tne Induction Motor Using SCR (Trial Manufacturing of Solid-state Frequency Converter))

  • 원종수
    • 전기의세계
    • /
    • 제19권4호
    • /
    • pp.1-11
    • /
    • 1970
  • It is well known that solid-state devices like inverter and converter made by transistor and other semi-conductors are widely used for the purpose of motor speed control in industrial fields. This paper is devoted primarily to a study of Trial Manufacturing of Solid-state Frequency Converter by means of single-phase bridge-type SCR inverter. The principle of the trial product belongs to AC-DC-AC conversion system. The voltage to be impressed to the motor in case of speed control by frequency conversion method is necessary to be proportional to frequency. It also requires the frequency and voltage are independent to hte load variation. In order to meet above requests required to motor speed control., the trial product introduced the open loop system in the frequency setting and closed loop system in the voltage setting. The trial product showed the favorable performance characteristics in speed control of singlephase fractional horsepower motor from 45HZ through 80HZ.

  • PDF

3상 전류평형 제어기술 알고리즘 개발 (A Development of 3 Phase Current Balance Control Algorithm)

  • 천영식;성형수;원학재;한정훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.1091-1093
    • /
    • 2001
  • The power semiconductor is widely used in the power plant or industrial field because of genealization and enlargement. It has been controlled and operated according to its own control method. Especially in case of Power plant, it plays a major role in AVR(Automatic Voltage Regulator) or electro chlorination control circuits. Generally, they used in Analog control system at above field. But each SCR current value is different because of load unbalance or switching characteristic variations, it may cause power plant unit trip or system disorder according to SCR element burn out or bad operating condition. Therefore, in this paper a development of 3 phase current balance control algorithm is described. it gets over the past analog control system limit, controls SCR gate firing angle for 3 phase current balance.

  • PDF

실차 실험을 통한 승용 디젤엔진의 Urea-SCR을 위한 암모니아 흡장률 피드백 제어 분사전략 검증 (Experimental Verification of Adsorption Rate Feedback Control Strategy for Automotive Urea-SCR DeNOX System)

  • 신병욱;박주영;이성욱;강연식
    • 대한기계학회논문집B
    • /
    • 제41권6호
    • /
    • pp.397-407
    • /
    • 2017
  • 본 논문에서는 연비손실 없이 높은 $NO_X$ 저감성능을 보이는 승용 디젤 엔진의 SCR 시스템을 위한 요소수의 분사전략을 제시하였다. 배출되는 $NO_X$량 대비 요소수가 화학량론적 1:1인 피드포워드 분사 전략과 함께 모델기반의 촉매 내 $NH_3$ 흡장률 추정 기법을 통하여 피드백 분사 제어전략을 함께 사용함으로써 과도상태에서 $NO_X$ 저감성능과 $NH_3$ 슬립 성능을 모두 만족시키고자 하였다. 제안된 분사전략을 적용하여 디젤산화촉매기와, 미립자필터가 장착된 2.2L 디젤 엔진을 갖춘 실제 차량에서의 실험을 통하여 제어기의 높은 $NO_X$ 저감률과 낮은 $NH_3$ 슬립 성능을 검증하였다.

템플릿에 기반한 NuSCR 정형 명세의 소프트웨어 고장 수목 생성 방법 (A Synthesis Method of Software Fault Tree from NuSCR Formal Specification using Templates)

  • 김태호;유준범;차성덕
    • 한국정보과학회논문지:소프트웨어및응용
    • /
    • 제32권12호
    • /
    • pp.1178-1191
    • /
    • 2005
  • 본 논문은 NuSCR 정형 명세 언어로 작성된 소프트웨어 요구 명세로부터 소프트웨어 고장 수목을 생성하는 방법에 대하여 제안하였다 본 연구에서 제안하는 소프트웨어 고장 수목은 소프트웨어의 구조와 동작에 대한 요구 사항을 반영하는 통합된 형태의 고장 수목으로, 안전성에 대한 복합적인 분석이 가능하다. 이러한 소프트웨어 고장 수목을 생성하기 위하여 NuSCR 정형 명세언어의 구성 요소 각각에 대한 템플릿을 정의하고, 이들 템플릿을 사용하여 소프트웨어 고장 수목을 생성하는 방법을 제안하였다. 그리고, 제안된 방법의 유용성을 평가하기 위해 현재 국내 원전계측제어시스템 개발사업단에서 개발 중인 차세대 원자력 시스템 APR1400에 사용될 원자로 보호 시스템의 핵심 트립 논리에 대하여 고장 수목을 생성하고 분석 하였다.

Mixer design for improving the injection uniformity of the reduction agent in SCR system

  • Hwang, Woohyeon;Lee, Kyungok
    • 한국컴퓨터정보학회논문지
    • /
    • 제22권1호
    • /
    • pp.63-69
    • /
    • 2017
  • In this paper, we propose a method to optimize the geometry and installation position of the mixer in the selective catalytic reduction (SCR) system by computational fluid dynamic(CFD). Using the commercial CFD software of CFD-ACE+, the flow dynamics of the flue gas was numerically analyzed for improving the injection uniformity of the reduction agent. Numerical analysis of the mixed gas heat flow into the upstream side of the primary SCR catalyst layer was performed when the denitrification facility was operated. The characteristics such as the flow rate, temperature, pressure loss and ammonia concentration of the mixed gas consisting of the flue gas and the ammonia reducing gas were examined at the upstream of the catalyst layer of SCR. The temperature difference on the surface of the catalyst layer is very small compared to the flow rate of the exhaust gas, and the temperature difference caused by the reducing gas hardly occurs because the flow rate of the reducing gas is very small. When the mixed gas is introduced into the SCR reactor, there is a slight tendency toward one wall. When the gas passes through the catalyst layer having a large pressure loss, the flow angle of the exhaust gas changes because the direction of the exhaust gas changes toward a smaller flow. Based on the uniformity of the flow rate of the mixed gas calculated at the SCR, it is judged that the position of the test port reflected in the design is proper.